Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover Upon completion of this module, you should be able to: Data Mover Failover Test.

Slides:



Advertisements
Similar presentations
Copyright © 2014 EMC Corporation. All Rights Reserved. Basic Network Configuration for File Upon completion of this module, you should be able to: Configure.
Advertisements

Copyright © 2014 EMC Corporation. All Rights Reserved. Linux Host Installation and Integration for Block Upon completion of this module, you should be.
Copyright © 2014 EMC Corporation. All Rights Reserved. VNX Snapshot Upon completion of this module, you should be able to: Describe VNX Snapshot operations.
PowerEdge M-Series CMC Management
Copyright © 2014 EMC Corporation. All Rights Reserved. ESXi Host Installation and Integration for Block Upon completion of this module, you should be able.
Chapter 3 Presented by: Anupam Mittal.  Data protection: Concept of RAID and its Components Data Protection: RAID - 2.
© 2006 EMC Corporation. All rights reserved. Network Attached Storage (NAS) Module 3.2.
Copyright © 2014 EMC Corporation. All Rights Reserved. Virtual Data Movers Upon completion of this module, you should be able to: Describe Virtual Data.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 8: Implementing and Managing Printers.
Lesson 1: Configuring Network Load Balancing
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 8: Implementing and Managing Printers.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 8: Implementing and Managing Printers.
Module – 7 network-attached storage (NAS)
Configuring Print Services Lesson 7. Skills Matrix Technology SkillObjective DomainObjective # Deploying a Print ServerConfigure and monitor print services.
Implementing Failover Clustering with Hyper-V
Copyright © 2014 EMC Corporation. All Rights Reserved. Exporting NFS File Systems to UNIX/ESXi Upon completion of this module, you should be able to: Export.
Copyright © 2014 EMC Corporation. All Rights Reserved. Unisphere Security and Basic Management Upon completion of this module, you should be able to: List.
Virtual Machine Management
Event Viewer Was of getting to event viewer Go to –Start –Control Panel, –Administrative Tools –Event Viewer Go to –Start.
Networking Features Upon completion of this module, you should be able to: Discuss and configure VNX networking features This module continues the discussion.
Chapter 5 Roles and features. objectives Performing management tasks using the Server Manager console Understanding the Windows Server 2008 roles Understanding.
11 REVIEWING MICROSOFT ACTIVE DIRECTORY CONCEPTS Chapter 1.
Configuring CIFS Upon completion of this module, you should be able to: Configure the Data Mover for a Windows environment Create and Join a CIFS Server.
Achieving Qualities 1 Võ Đình Hiếu. Contents Architecture tactics Availability tactics Security tactics Modifiability tactics 2.
Data Center Infrastructure
© 2006 Cisco Systems, Inc. All rights reserved. Network Security 2 Module 8 – PIX Security Appliance Contexts, Failover, and Management.
Introduction to VMware Virtualization
INSTALLING MICROSOFT EXCHANGE SERVER 2003 CLUSTERS AND FRONT-END AND BACK ‑ END SERVERS Chapter 4.
Copyright © 2014 EMC Corporation. All Rights Reserved. Block Storage Provisioning and Management Upon completion of this module, you should be able to:
Chapter 8 Implementing Disaster Recovery and High Availability Hands-On Virtual Computing.
Copyright © 2011 EMC Corporation. All Rights Reserved. MODULE – 6 VIRTUALIZED DATA CENTER – DESKTOP AND APPLICATION 1.
Example STP runs on bridges and switches that are 802.1D-compliant. There are different flavors of STP, but 802.1D is the most popular and widely implemented.
Copyright © 2014 EMC Corporation. All Rights Reserved. VNX SnapSure Upon completion of this module, you should be able to: Describe VNX SnapSure theory.
DB-2: OpenEdge® Replication: How to get Home in Time … Brian Bowman Sr. Solutions Engineer Sandy Caiado Sr. Solutions Engineer.
Copyright © 2014 EMC Corporation. All Rights Reserved. SnapView Snapshot Upon completion of this module, you should be able to: Describe SnapView Snapshot.
Copyright © 2014 EMC Corporation. All Rights Reserved. Windows Host Installation and Integration for Block Upon completion of this module, you should be.
Module 15 Managing Windows Server® 2008 Backup and Restore.
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 1: Introduction to Scaling Networks Scaling Networks.
Module 13: Designing Print Services in Windows Server 2008.
Copyright © 2014 EMC Corporation. All Rights Reserved. Managing Host Access to Storage Upon completion of this module, you should be able to: Explain Access.
1 © 2005 Cisco Systems, Inc. All rights reserved. 111 © 2004, Cisco Systems, Inc. All rights reserved. CNIT 221 Security 2 ver.2 Module 8 City College.
Core 3: Communication Systems. Network software includes the Network Operating Software (NOS) and also network based applications such as those running.
© 2006 Cisco Systems, Inc. All rights reserved.Cisco PublicITE I Chapter 6 1 VLANs LAN Switching and Wireless – Chapter 3.
Chapter 13: LAN Maintenance. Documentation Document your LAN so that you have a record of equipment location and configuration. Documentation should include.
SnapView Clones Upon completion of this module, you should be able to:
1 Chapter Overview Managing Object and Container Permissions Locating and Moving Active Directory Objects Delegating Control Troubleshooting Active Directory.
High Availability in DB2 Nishant Sinha
Peter Mattei HP Storage Consultant 16. May 2013
© 2006 EMC Corporation. All rights reserved. The Host Environment Module 2.1.
1 VLANs Relates to Lab 6. Short module on basics of VLAN switching.
Configuring, Managing and Maintaining Windows Server® 2008 Servers Course 6419A.
2 Copyright © 2007, Oracle. All rights reserved. Configuring for Recoverability.
2 Copyright © 2006, Oracle. All rights reserved. Configuring Recovery Manager.
DPM - IPMI Product Support Engineering VMware Confidential.
29 Copyright © 2009, Oracle. All rights reserved. Administering the Oracle Business Intelligence Presentation Catalog.
© 2002, Cisco Systems, Inc. All rights reserved..
Eric Liu – Remote Proactive
How to setup DSS V6 iSCSI Failover with XenServer using Multipath Software Version: DSS ver up55 Presentation updated: February 2011.
13 Copyright © 2007, Oracle. All rights reserved. Using the Data Recovery Advisor.
Configuring Print Services Lesson 7. Print Sharing Print device sharing is another one of the most basic applications for which local area networks were.
Redundant Bricks Configuration Example Lucent Security Products Configuration Example Series.
© 2002, Cisco Systems, Inc. All rights reserved..
Operating Cisco IOS Software
© 2002, Cisco Systems, Inc. All rights reserved.
Network Attached Storage Overview
Vmware 2V0-642 VMware Certified Professional 6 - Network Virtualization (NSX v6.2) VCE Question Answers.
Global Catalog and Flexible Single Master Operations (FSMO) Roles
Dumps PDF Vendor: Microsoft Exam Code:
NTC 324 RANK Lessons in Excellence-- ntc324rank.com.
Global Catalog and Flexible Single Master Operations (FSMO) Roles
Presentation transcript:

Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover Upon completion of this module, you should be able to: Data Mover Failover Test Data Mover Failover and Failback Data Mover Failover1

Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover Lesson 1: Data Mover Failover Data Mover Failover2 During this lesson the following topics are covered: The failover process and policies Standby Data Movers Planning and Configuring Data Mover failover

Copyright © 2014 EMC Corporation. All Rights Reserved. Failover Process Primary Data Mover (DM) fails Designated Standby Data Mover is activated as a spare  Requires identical network configuration Data Mover Failover 3

Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover failure detection Failover occurs under any of these conditions  Data Mover panic: A hardware or software faults  Data Mover hang: A condition that leads to both internal down  Failover failure: Failure during a failover operation.  Spontaneous Data Mover reset Failover does not occur under these conditions  Manually restarting a Data Mover  Removing a Data Mover its slot  Network Failure Data Mover Failover 4

Copyright © 2014 EMC Corporation. All Rights Reserved. How Data Mover Failover Works Normal operations  Control Station constantly monitors all Data Movers (DM) When Primary DM fails  Control Station instructs Standby to take over  Standby resumes entire identity and all production services  Original Primary goes into failed state After problem is resolved  Administrator manually initiates restoration of original Primary Data Mover Failover 5 FAILEDPrimary Data Mover Control Station “Go!” Primary Data MoverStandby Data Mover Control Station Monitor Primary Data MoverStandby Data Mover Control Station Monitor Restore

Copyright © 2014 EMC Corporation. All Rights Reserved. Standby Data Mover Hot-spare for Primary Data Movers Can act as a spare for up to 7 primaries (depending on model)  Recommended ratio is at least one Standby for three primaries For the highest availability, use 1:1 ratio On a two Data Mover VNX, server_3 is pre-configured as a Standby for server_2 VNX OE software is the same for all hardware platforms Data Mover Failover6

Copyright © 2014 EMC Corporation. All Rights Reserved. Failover Policies Pre-determined action Invoked by the Control Station when it detects a failover condition Policy types  Auto  Retry  Manual Data Mover Failover7

Copyright © 2014 EMC Corporation. All Rights Reserved. Planning for Data Mover Failover Determine Primary and Standby Data Movers  Ensure Primaries and Standbys have the same network hardware components  Standbys are free of any configurations Switch ports of the Standby Data Movers are assigned to the same VLANs as the Primary Ethernet Jumbo frame configuration related to Primary Data Mover ports are in place for the Standby Data Mover Network configuration must be identical  Speed/Duplex  LACP / Link aggregation  Fail Safe Networking (FSN) Data Mover Failover8

Copyright © 2014 EMC Corporation. All Rights Reserved. Failover Configuration Data Mover Failover 9 To configure server_3 as the Standby for server_2: 1. Select System > Hardware > Data Movers 2. Select the Data Mover, and click Properties. 3. Set Standby Movers to server_3 4. Failover Policy, auto 5. Click Apply Server role Failover policy Standby DM

Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover During this lesson the following topics were covered: The failover process and policies Standby Data Movers Planning and Configuring Data Mover failover Lesson 1: Summary Data Mover Failover10

Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover During this lesson the following topics are covered: Testing Data Mover failover Restoring a Data Mover Deleting a Data Mover failover relationship Lesson 2: Testing Data Mover Failover and Failback Data Mover Failover11

Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover Testing Considerations Test Data Mover failover periodically/regularly (e.g. Quarterly) Perform test at low/no impact times When testing, validate the following  Standby assumes the identity of Primary  VLAN membership and LACP configuration  User access to:  File systems  Shares  Home directories Data Mover Failover12

Copyright © 2014 EMC Corporation. All Rights Reserved. Testing Data Mover Failover Run the following CLI Command to manually activate the Standby Data Mover server_standby –activate mover Data Mover Failover13

Copyright © 2014 EMC Corporation. All Rights Reserved. Restoring a Data Mover After Failover System > Hardware > Data Movers Select Data Mover to restore and click Restore Data Mover Failover14

Copyright © 2014 EMC Corporation. All Rights Reserved. Deleting a Failover Relationship To delete Standby relationship: Hardware → Data Movers > Server_x → uncheck field Standby Movers Data Mover Failover 15 To change Data Mover from Standby to Primary: Hardware → Data Movers → server_x → select Role: Primary

Copyright © 2014 EMC Corporation. All Rights Reserved. Data Mover Failover During this lesson the following topics were covered: Testing Data Mover failover Restoring a Data Mover Deleting a Data Mover failover relationship Lesson 2: Summary Data Mover Failover16

Copyright © 2014 EMC Corporation. All Rights Reserved. Summary Key points covered in this module: Successful Data Mover failover requires careful planning of network switch and port configurations Test plans should include validating access to VNX resources:  File systems  Shares  Home directories Data Mover Failover17

Copyright © 2014 EMC Corporation. All Rights Reserved. Course Summary Key points covered in this course: Configuration of Unisphere Security and Features Configuration and management of VNX block access for open systems hosts (Linux, Windows and VMware ESXi) Configuration and management of VNX file access for Windows and Linux user/application environments via NFS and CIFS environments Configuration of VNX local replication in block and file environments 18Data Mover Failover

Copyright © 2014 EMC Corporation. All Rights Reserved. Thank You!

Copyright © 2014 EMC Corporation. All Rights Reserved. This slide is intentionally left blank. Data Mover Failover20