Fig. 5 Fig. 6 Fig. 8a a b c d ~1 mm Fig. 7 Fig. 8b ~1 mm Figure 5a) Available keepers implanted directly into the mastoid bone. 5b) Single inner-thread.

Slides:



Advertisements
Similar presentations
DESIGN FOR XXX Design Strategies. Design for X Design Strategies 6/1/ Part shape strategies: adhere to specific process design guidelines if part.
Advertisements

Manufacturing Processes lab I Running a lathe machine
ISE 311 Sheet Metal Forming Lab Cup Drawing in conjunction with Section 20.3 in the text book “Fundamentals of Modern Manufacturing” Third Edition Mikell.
Manufacturing Products
Vacuum Vessel Production Readiness Review
Screws, Fasteners, and the Design of Nonpermanent Joints
CE7005 Prestressed Concrete
General Design Guidelines
Design Group: Wei-Yuan Chu Adrian Conrad Thomas Hylton Scott Jean Nicholas Metzger IUPUI Faculty Advisor: Dr. Jie Chen Rolls-Royce Advisor: Timothy Fuesting.
New Mexico FFA Agricultural Mechanics Career Development Event Engine Power.
INTRODUCTION The ultimate goal of a manufacturing engineer is to produce steel/metal components with required geometrical shape and structurally optimized.
Physics of bone By Mashael Saud. Bone consists of two quite different materials plus water: 1. Collagen, the major organic fraction, which is about 40%
Design Partition, Project Plan, Task Assignments and Conceptual Designs September 13, 2006 Team Moondogs Chris Culver Rahul Kirtikar Elias Krauklis Christopher.
Abstract Intramedullary nails (IN) present one method of repairing long bone fractures. Upon insertion into the intramedullary space the nail is fastened.
Chapter 7 Fatigue Failure Resulting from Variable Loading
9 Torsion.
Chapter 15: Fundamentals of Metal Forming
STRUCTURES Outcome 3 Gary Plimer 2008 MUSSELBURGH GRAMMAR SCHOOL.
Metallic Materials.  Types of metallic Materials * Aluminum * Brass * Bronze * Stainless Steel * Carbon Steel * Copper.
Universal College Of Engineering & Technology
Problem Statement Project Proposal Design a device that will reduce the time of a medial malleolus fracture repair surgery Design a device that simplifies.
Authors Joel Rotroff Ben Moga Tom Pearce Hani Bou-Reslan BME 402 April 30th, 2004.
MECHANICS OF MATERIALS Fourth Edition Ferdinand P. Beer E. Russell Johnston, Jr. John T. DeWolf Lecture Notes: J. Walt Oler Texas Tech University CHAPTER.
Stress and Strain – Axial Loading
Engineering Mechanics: Statics
Brookhaven - fermilab - berkeley US LHC ACCELERATOR PROJECT LHC IRQ Inner Triplet Review Q1, Q2, and Q3 Mechanics T. Nicol April 24-25, 2007.
3 Torsion.
Machine Design I (MCE-C 203) Mechatronics Dept., Faculty of Engineering, Fayoum University Dr. Ahmed Salah Abou Taleb Lecturer, Mechanical Engineering.
3 Torsion.
Mechanical Properties of Materials
ENGR 107 – Introduction to Engineering Static Equilibrium, and Stress and Strain (Lecture #8)
Abstract There is a high amount of necessity in third world countries for many concepts in mechanical engineering to inspire learning and choosing engineering.
Instron ® – A World Leader in Materials Testing An overview of recent changes and challenges facing rebar manufacturers, suppliers, and consumers Challenges.
Teaching Innovation - Entrepreneurial - Global
ENGINEERING MATERIALS Haseeb Ullah Khan Jatoi Department of Chemical Engineering UET Lahore.
MACHINING OPERATIONS AND MACHINE TOOLS 1.Turning and Related Operations ©2007 John Wiley & Sons, Inc. M P Groover, Fundamentals of Modern Manufacturing.
Factors Affecting Tool Life In Machining Processes
STRUCTURES Young’s Modulus. Tests There are 4 tests that you can do to a material There are 4 tests that you can do to a material 1 tensile This is where.
4.4 Size of a Horizontal Boring Machine:  Conventionally, the size of a horizontal boring machine is specified by the spindle diameter in mm.  The spindle.
ENM208 INTRODUCTION to MACHINING ANADOLU UNİVERSITY Industrial Engineering Department.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
Manufacturing Engineering Technology in SI Units, 6 th Edition Chapter 23: Machining Processes: Hole Making – Part A (Lathe Operations, Boring, Reaming,
Microtia affects 1:10,000 births a Improve quality of life for patients b Develop better outcomes than reconstruction b 6% patients unhappy with stability.
24 September 2012 Immanuel Gfall (HEPHY Vienna) SVD Status of Mechanics PXD-SVD Meeting Göttingen.
Bulk deformation Processes II
Prosthetic Ear Fixation March 9, Design Team Team Members Cullen Rotroff Evan Rogers Joe Hippensteel Steve Noel Ashley Phillips Advisor Prof. Willis.
Solid-State Welding Processes
Shafts and Shaft Components
Right Angle Screwdriver
Implant-Retained Finger Prosthesis
MAGM 262 Hydraulic Seals Mr. Conrado.
Sheet Metal Forming Lab Cup Drawing in conjunction with “Fundamentals of Modern Manufacturing” Third Edition Mikell P. Groover.
MACH 118: Lathe & Mill 1 Lathe Workholding.
Steerable Needle for Core Biopsy
Stress and Strain – Axial Loading
Solid-State Welding Processes
Automotive Engines Theory and Servicing
3 Torsion.
Engineering Mechanics: Statics
BDA30303 Solid Mechanics II.
Contents Introduction Identification of the knowledge gap
3 Torsion.
ACL INTERFERENCE SCREW
3 Torsion.
Applied Technology High School (ATHS)
Lab8: Fatigue Testing Machine
Lab8: Fatigue Testing Machine
Introduction to Presses
Automotive Engines Theory and Servicing
Design Strategies Design for XXX.
Presentation transcript:

Fig. 5 Fig. 6 Fig. 8a a b c d ~1 mm Fig. 7 Fig. 8b ~1 mm Figure 5a) Available keepers implanted directly into the mastoid bone. 5b) Single inner-thread female post. 5c) Single turn screw cap replacing one magnetic cap. 5d) Two magnetic posts included to supplement new post design. 6) Fixation mechanism with ear detached. 7) Fixation mechanism with ear attached. Center post allows for axial translation. 8) Detailed view of novel fixation components. Introduction limits for the magnetic attachment system (Fig 4b). This test failed to provide reliable results because the recording software begins after the bending arm applies a minimum force; the prosthesis would detach consistently before the initiating five N load was supplied. Qualitative testing was done by the client to determine the bond strength with stainless steel in the prosthetic ear. Testing was done with a primer from Nusil Technologies. Bond strength was compared to steel placed in silica with and without the primer. Once the steel was placed in the silica, the samples were heated for one hour and allowed to cool. The bond was found to be of sufficient strength, showing failure in the bulk silica and not at the bond interface. These initial designs falter with their inclusion of moving parts. Figure 3 displays various designs which use a clipping mechanism to attach the prosthesis. Figures 3b and 3c show a flexible, clipping post, which latches around a disk descending from the prosthesis. The small scale of these moving parts provoked significant concerns with fragility. After considering the excessive wear resulting from day to day use, a system with static parts became a major design requirement. The current attachment systems fasten three titanium keepers directly into the mastoid bone. A post is screwed into each of the keepers (Fig. 1a). Figure 1a uses three magnetic posts to fasten the prosthetic ear. For a clipping attachment, a bar is placed over three posts that align with clips in the prosthesis (Fig. 1b). Prosthetic Ear Fixation Mechanism Joseph Hippensteel, Steve Noel, Ashley Phillips, Evan Rogers, and Cullen Rotroff Department of Biomedical Engineering, University of Wisconsin Client: Greg G. Gion, BA, BS, MMS, CCA Advisor: Willis Tompkins, Ph.D, Dept. of Biomedical Engineering Future Work Any mechanism that can endure more than 5 N of normal or shear force without detachment is an improvement; however, product life and user safety require further consideration and long term testing. The addition of the threaded safety lock introduces new, small parts. It will be vital to determine the life span of the abutment's inner thread. To determine this, various simulations of unexpected normal and shear forces on the prosthesis will be conducted in addition to continuous attachment and removal simulations. The device should operate properly for a minimum of ~1,000 attachment cycles without destructive wear. By increasing the amount of force the prosthesis can endure without detaching, the device effectively increases force transferred to the user's mastoid. With the fixture anchored in the mastoid, it is imperative that a minimum injury force is identified. If the prosthesis withstands and transfers the force from subsequent impacts to the patient in such a way that causes injury, the design must be modified to include a breakaway force. The breakaway force would be a prosthesis detachment mechanism that engages well before a damaging force could be transferred to the mastoid bone. Abstract There are currently two mechanisms in use to attach prosthetic ears. A magnetic mechanism provides an easy, yet precarious, attachment. A clipping mechanism affords a stable attachment but requires excessive force, inducing eventual wear on the prosthesis. A new fixation mechanism was desired that provides secure fixation with minimal attachment force. A new method was developed that combined two magnetic place holders with a threaded locking-post. Figure 1a) Illustration of keeper and post. 1b) Clipping mechanism Fig. 1a Fig. 1b Problem Statement A new prosthetic ear attachment system is desired. It should prevent accidental detachment, while limiting the force required for attachment and removal; the improved attachment method should minimize abrasion to the coating of the ear. The system should be indiscrete and accessible for cleaning and maintenance when the prosthesis is detached. The posts must be retrofitted to fit the current keeper design. Lastly, the system should be easily manufactured, facilitating a manageable incorporation into mass-production. Figure 2) Patient with a prosthetic ear. Figure 3a) This initial design attached the prosthesis to the post with a spring loaded clip. 3b) Normal force opening clip mechanism. 3c) Clip in locked position. Preliminary Designs The magnetic system minimizes prosthesis abrasion with a nominal attachment force, but its fixation is unstable. Conversely, the clipping mechanism provides a secure fixation but requires a large attachment and detachment force, causing prosthesis wear and discoloration. Most patients needing a prosthetic ear have suffered from trauma or were born with microtia, a congenital deformity of the outer ear. An improved quality of life can be obtained with the use of a prosthetic ear made to mirror the contralateral ear (Fig. 2). Fronczak, Frank. Personal interview. 1 Mar Gion, Greg G. "Facial and Somato Prosthetics." 3 Mar Vistafix Product Catalog. Colorado: Cochlear Americas. References/Acknowledgements Testing A strain gauge was used to determine the shear and normal force limits of the magnetic attachment (Fig 4a). Results in the shear and normal direction ranged from one to two pounds. The strain gage only measured one significant figure, yielding inaccurate results. Consequently, a three point bending machine was used to verify shear Final Design Our final design utilizes a modest alteration to the current magnetic attachment system; the two outer posts shown in figure 5d will remain unchanged magnetic attachments. The center post, however, is notably altered in design and function, now serving as a secondary lock; this post provides little force in normal use but prevents unintended removal of the prosthesis when exposed to normal or shear forces. Center Post Design The Center Post was retrofitted to fit with current keeper design. The design uses an interlocking thread to secure the prosthesis to the patient. The center post has relatively larger outer diameter protruding from the mastoid of the subject (Fig 5b). The protrusion is a hollowed cylinder, with 1 mm thick walls. The distal face the cylinder wall has a slightly narrower inner diameter. This inner diameter of the distal face contains a single thread to permit screw cap entry and exit into the post (Fig 8a). Screw Cap Design The screw cap design is to attach solely with the center post. The screw cap is a solid cylinder emerging from the inner face of the prosthetic ear (Fig. 5c). The cap is tapered at the bottom two mm of the cylinder. Just above the taper origin, the cylinder has a single revolution of threading (Fig. 8b). The thread is positioned such that the screw cap may slide up and down within the post cylinder once medial to its thread (Fig. 7). To attach the prosthesis, the user must insert the screw cap into the center post and then rotate the entire prosthesis one revolution (Fig 9). The subject can then adjust the prosthesis’ orientation to align and attach the two outer magnetic caps with their respective magnetic posts. The outer caps adhere the prosthesis to the subject’s skin surface, while the inner cap blocks prosthesis detachment. To remove the prosthesis, the user must simultaneously apply a tensile normal force in conjunction with a rotational force to bypass the threading. Fig. 9 Figure 9: Attachment and removal of the prosthetic ear is achieved through a 360º rotation. The ear is manipulated such that the magnets maintain tight fixation. Fabrication Process The process used to fabricate the prototype may serve as an ideal method for mass production of the new post and screw cap designs. The keeper will go unchanged in the new system and requires no production considerations. The threaded post, however, creates the difficult manufacturing problem of placing a functional inner thread in a two mm diameter cylinder. To accomplish this, the outer diameter of the post is cut and its outer threads are formed. After the cylinder’s 2.5 mm inner diameter is bored from the distal surface, the outermost edge of the distal surface is rolled inward. The elastic modulus of standard steel allows its thin walls to be curled inward, producing a narrower diameter at the surface. Finally, the single thread is cut into the narrowed of the inner cylinder. Definitions Keeper : Initial attachment piece that is permanently screwed into the patient’s mastoid bone. Post : Protruding intermediate piece between the keeper and screw/cap. Screw/Magnetic cap : Any piece that descends from the prosthesis and attaches to the post. Figure 4a) Prosthetic ears and strain gage Figure 4b) Three point bending machine Fig. 3b Fig. 3c Fig. 3a Fig. 4b Fig. 4a