W e m a k e i d e a s c o m e a l i v e 001IHP050501 For internal use only Not only a peripheral stent available in Renal sizes...

Slides:



Advertisements
Similar presentations
W e m a k e i d e a s c o m e a l i v e 001SCB For internal use only Peripheral Co-Cr Stent System OTW On the cutting edge of flexibility and strength.
Advertisements

W e m a k e i d e a s c o m e a l i v e 001IMP For internal use only Flexibility and Precision in Peripheral Arteries 0.035” OTW Self- Expanding.
PCI Unmet Clinical Needs
Balloons and Wires Adam B. Greenbaum, MD Associate Director, Cardiac Cath Lab Henry Ford Heart and Vascular Institute No relationships to disclose in relation.
Subtitle Text Here Zylon Medical Devices Smaller Is Better Supported by NIH SBIR PHASE II Grant # 5 R44 H
Medtronic Engager™ Transcatheter Aortic Valve Implantation System Procedure Quick Review And Tips August 2013 Innovating for life. UC a EE Engager.
Pitfalls & Practical Tips
W e m a k e i d e a s c o m e a l i v e For internal use only Covering all your needs for Fem-Pop Interventions.
AVE Micro Stent KFSH & RC Experience with 6 months Angiographic Follow Up Layth A. Mimish, M. Bakhshi, F. Al-Nozha, A. Kinsara, O. Amoudi, J. Buraiki,
Self-Expanding Stents VS Balloon-Expanding Stents
Θεματική ενότητα: Stenting
CATCH : Mechanical Thrombus Retriever
2 Introduction Drug-eluting stents have defined a new era in the successful treatment of coronary artery disease However, like any therapy, DES results.
C. Graidis, D. Dimitriadis, A. Ntatsios, V. Karasavvides
1 *Report IIB(R) 27/ The CoStar Stent (Conor) was also tested but is not shown in this report as it only presents the commercially available stents.
Confidential: Internal Use only 1 Click to edit Master title style Click to edit Master text styles – Second level Third level – Fourth level » Fifth level.
Featuring CTO Complex-PCI by Trans-radial Approach CTO Case review 5 French TRI CTO of right coronary artery -5 F Launcher guiding Catheter (right Judkins.
INTRODUCTION TO NEUROFORM ATLAS
Range & Specifications CASE #1: 80% stenosis of the left renal artery located at the ostium of the vessel. HELIOS 6x13.
4.4.1 Unblocking the Vessel.
New strategies and perfusion/aspiration devices for primary PCI Sandra Garcia Cruset, PhD. Cordynamic B.U. Marketing Manager.
The First Affiliated Hospital of Harbin Medical University
Renal Intervention by the Radial Approach Josef Ludwig, Erlangen Angiosoft.NET.
Featuring Bifurcation Trans-Radial Approach Technical Issues Martial Hamon Caen, France Provisionnal T stenting With the Frontier stent Main Branch Balloon.
ClearWay™ RX Therapeutic Perfusion Catheter. ClearWay™ RX In Action Potential Advantages of ClearWay TM: Delivers drug at high concentration to site of.
Presents the new 3-Dimensional Open Loop Designed AndraSnare& AndraSnare Micro.
经桡肾动脉支架术 Transradial Approach in Renal Stenting Jianfang Luo 罗建方 Guangdong General Hospital.
Date of download: 6/2/2016 Copyright © The American College of Cardiology. All rights reserved. From: Retrograde Techniques and the Impact of Operator.
Overcoming difficult access in intracranial interventions: A to Z
Double lumen remodeling balloon: New technique for treatment of MCA bifurcation aneurysm Kadziolka K, Leautaud A., Estrade L., W. Mustafa, Pierot L. CHU.
COVIDIEN FOR ADVANCED TECHNOLOGIES
The Endocross Enabler-P: First in-Human Results
Valvuloplasty Scoring Balloon for the Treatment of Critical Aortic Valve Stenosis - Design of a FIM Study - Gary Gershony, MD, FACC, FSCAI, FAHA, FRCPC.
Ospedale San Raffaele, Milan, Italy
Takashi Ashikaga,MD,PhD
Product Specifications
Bifurcation Balloon & Stent Delivery System
Renal Artery Angioplasty and Stenting with Embolic Protection
Abbott Vascular Bifurcation Program
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Understanding Stent Deformation
ClearWay™ RX Therapeutic Perfusion Catheter
CAS –Strategy, Pitfalls, and Safety Issues
Clinical Presentation
A Novel “Stent-On-A-Wire”Ultra Low Profile Stent Delivery System
CARDIAC CATHETERIZATION
CRT Washington, D.C. February 23, 2010 Tim A. Fischell, M.D. FACC
Meruzhan Saghatelyan, MD, Interventional cardiologist
Ravi K. Ghanta, MD, John A. Kern, MD 
A Fixed Guidewire Stent Delivery System
How to do endovascular mechanical thrombaspiration
From: Improved Ease of Use Designs for Rapid Heart Cooling
James P. Zidar, M.D., F.A.C.C., F.S.C.A.I
Venous System Interventions for Device Implantation
Ravi K. Ghanta, MD, John A. Kern, MD 
Endovascular Treatment of Acute Descending Thoracic Aortic Dissections
Toshifumi Kudo, MD, PhD, Kenneth K. Kao, BA, Scott D
Transradial Intravascular Ultrasound Guided Culotte Stenting with Zotarolimus Eluting Coronary Stents in Renal Artery Bifurcation Stenosis  Z. Ruzsa,
Failure modes of thoracic endografts: Prevention and management
NEW GENERATION STENT COBALT-CHROMIUM SIROLIMUS ELUTING STENT.
Techniques in occluding the aorta during endovascular repair of ruptured abdominal aortic aneurysms  Mark Edward O’Donnell, DSEM, MRCS, Stephen A. Badger,
Technical aspects of repair of juxtarenal abdominal aortic aneurysms using the Zenith fenestrated endovascular stent graft  Gustavo S. Oderich, MD, Mateus.
Strategy based on Thrombus-Grade for Management of the STEMI Lesion
Intra-Aortic Balloon Pumps
Should patients with challenging anatomy be offered endovascular aneurysm repair?  Roy K Greenberg, MD, Daniel Clair, MD, Sunita Srivastava, MD, Guru Bhandari,
Θεματική ενότητα: Stenting
EVAR Overview and stent-graft implantation in complex iliac anatomy
Drug-eluting coronary stent market overview
Presentation transcript:

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Not only a peripheral stent available in Renal sizes...

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Specification SDS Catheter design Guide wire compatibility Usable shaft length Length of RX section Balloon material Prox./distal Shaft diameter Crossing profile Introducer compatibility Guiding Catheter comp. Nominal pressure RBP Rapid Exchange with NiTi-wire reinforced RX-section, hypotube shaft 0.014“ 80, 145 cm 15 cm FLEXITEC™ LP 2,3F / 3,5F < 0.065” 5F6F 8 bar 14/15 bar

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Specification Stent Stent design Range of diameter Maximum expansion Range of length Stent material Strut thickness Strut width Metal to Artery Ratio Closed cell, slotted tube Ø 4.0, 5.0, 5.5, 6.0, 6.5, 7.0 mm 7.5 mm 10, 15, 20, 24 mm Stainless steel 165 µm 110 µm Ø 6 mm

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Hippocampus in Detail

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only How does it work? 1/6  Insert 0.014” guidewire through a guiding catheter or long introducer sheath into the renal artery.

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only How does it work? 2/6  Advance slowly the Hippocampus stent system through GC or IS into the renal ostium.  Since the system shows a progressive flexibility, coming from the long tip, followed by the long balloon-cone, the guidewire will not be straightened and possibly flipped out of the ostium! Non-Flip-Tip

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only How does it work? 3/6  Advance slowly the Hippocampus stent system through GC/IS into the renal ostium.  As soon as the balloon segment with the crimped stent is advanced through the curve of the GC/IS, the long tip is already inserted in the ostium so the position cannot be lost again. Progressive Flexibility Superior Vessel Accessibility

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only How does it work? 4/6  Position the stent inside the lesion, so that the proximal 1-2 mm of the stent will overlap into the Aorta. Since it will not shorten, this position can be easily maintained during inflation. Zero Stent-Shortening for Precise Positioning

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only How does it work? 5/6  Inflate the stent carefully, with slow increasing pressure until a proper dilation of the lesion is achieved. High Pressure Balloon for Optimal Results

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only How does it work? 6/6  Flaring the proximal stent section into the ostium is optional, because this might facilitate any following re- intervention of this renal artery. Ostial Scaffolding Capability Facilitating Re-interventions

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Non-Flip-Tip Non-Flip-Tip  Long Non-Flip-Tip with progressive flexibility and minimal entry profile  Tip length 7mm  6 folded high pressure balloon  Tight FIX  secure crimping

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Progressive Flexibility  Progressive Flexibility on distal balloon segment starting from the long Non-Flip-Tip followed by the Long Cones provides a superior vessel accessibility. NO balloon overhang! It is the long small angle cone that looks like a balloon overhang! 30°

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Stent System Dimensions in Detail Tip length 7 mm Rapid Exchange section 15 cm Stent length 10, 15, 20, 24 mm Distal shaft Ø 3,5F Stent I.D. Ø

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Crossing Profiles  Ø 4.0, 5.5, 6.0 mm  mm ( – ”) ”  Ø 5.0, 6.5, 7.0 mm  mm ( – ”) ”

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Zero Stent-Shortening  Zero Stent-Shortening and precise alignment of the Stent with the proximal marker band enables the operator to precisely position the stent inside the ostium. Proximal Stent Edge/ Balloon Marker

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Enhanced Pushability  For the normal RX- sections, there will be an increased friction, when passing through the curve of GC  The Ni-Ti wire is straightening the RX- section in order to transfer the maximum of push through the curve. Push Loss Tapered NiTi-wire inside the 15 cm long rapid exchange section reinforces the distal catheter section and clearly enhances the pushability.

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Ostial Scaffolding Capability Ostial sectionDistal section  Flaring the proximal stent section into the ostium is optional, because this might facilitate any following re- intervention of this renal artery.

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Everything is Possible  Shaft length of 80 and 145 cm enable you to perform radial approaches, which have significant benefits for the patient.

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only SDS Compliance  Controlled compliance of the FLEXITEC™ HS with high strength balloon material, which ensures a proper Stent deployment including a large working range at high pressures of bar.

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Size Mix Stent Ø - L    7.0 Usable shaft length: 80 and 145 cm

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Frequently Asked Questions  Why such a long balloon overhang?  It’s no balloon overhang, it is a long cones with a small opening angle for a progressive flexibility from the long Non-Flip-Tip over the Long Cones till the crimped stent segment.  In the common ostial stenting procedures it is NOT acceptable to engage the GC in the ostium, or even advance it through the ostium. NO – TOUCH - PROCEDURE The GC has to remain in front of the renal artery inside the aorta.  Why is the rapid exchange section only 15 cm long?  The SDS is dedicated to renal application, where you only have to reach the renal ostia. That shorter the RX-section is, that higher is the pushability.  What for a NiTi-wire inside the RX-section?  To reduce the friction inside the GC/IS and consequentially improve the pushability.

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Frequently Asked Questions (cont.)  Are there any clinical data available?  Not yet for the Hippocampus. But we are about to start a multicenter (4) registry “PRECISION” (Renal artery angioplasty in Patients with hypertension and renal insufficiency using Hippocapmus renal stent) with the PI Dr. Thomas Zeller from Germany enrolling 50 patients.  The ostial scaffolding capability is not needed!  Maybe that this operator does not care about any potential re- intervention. But without flaring the ostial section of the stent, the engagement of the ostium with a guidewire can become a very tricky procedure.  Why is the guiding catheter compatibility 6F and the introducer sheath comp. 5F?  A guiding catheter has always the outer diameter indicated. In case a long introducer sheath will be used instead of a GC, the inner diameter of the IS is sufficient with 5F.

W e m a k e i d e a s c o m e a l i v e 001IHP For internal use only Positioning  The Hippocampus is a Renal Stent System of the latest generation.  The design and architecture of the stent AND the delivery system is absolutely dedicated to the renal artery approach or similar anatomies (e.g. mesenteric artery).  It is NOT a normal peripheral stent, with a size mix suitable for renal arteries!  Due to the ease of insertion of the stent system into the renal artery, the product has the potential to  reduce the procedural risks  decrease the duration of the procedure  improve the technical success  Hippocampus should be sold on premium price!

Select Properly Where to Go, and Seize the Best Opportunity!