Implementing TI Billet Phased Array on the Shop Floor By Mark Pompe, West Penn Testing Group Jeff Umbach, Pratt & Whitney Experience at West Penn Testing.

Slides:



Advertisements
Similar presentations
EPOCH 1000 Series Software Feature AWS D1.1/1.5
Advertisements

Softricity LLC Advance slides with arrow keys. Without PDMLynx Informal processes based upon excel, access, paper files No consistency across organization.
Chapter3 Pulse-Echo Ultrasound Instrumentation
EPOCH 1000 Series Software Update New Features - March 2010.
D-Scan 701 & D-Scan 705.
ICS Test Environment Alexander Söderqvist Dec 9, 2014.
The Ideal Angle Beam Probes for DGS Evaluation Wolf Kleinert, York Oberdoerfer, Gerhard Splitt, GE Sensing & Inspection Technologies GmbH, Huerth, Germany.
EPOCH 1000 Series Procedure Multi-Angle Feature. Feature Overview and Activation.
Data Acquisition Risanuri Hidayat.
Update of EXT Stripline BPM Electronics with LCLS-style Digital BPM Processors Glen White, with slides by Steve Smith 15 December 2009 ATF2.
EPOCH 1000 Series Procedure Phased Array DGS/AVG
MEG Experiments Stimulation and Recording Setup Educational Seminar Institute for Biomagnetism and Biosignalanalysis February 8th, 2005.
Integrating a Short Range Laser Probe with a 6-DOF Vertical Robot Arm and a Rotary Table Theodor Borangiu Anamaria Dogar
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
“ULTRASONIC SYSTEM OF DISTANT DETERMINATION COORDINATES”
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
Calibration and Status of MOBY Dennis Clark, NOAA/NESDIS Carol Johnson, NIST Steve Brown, NIST Mark Yarbrough, MLML Stephanie Flora, MLML Mike Feinholz,
Detection of Weld Defects in Rails by Ultrasonic Software Statistical and algorithmic ultrasonic software techniques are used in the analysis of ultrasonic.
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
Chapter 25 Nonsinusoidal Waveforms. 2 Waveforms Used in electronics except for sinusoidal Any periodic waveform may be expressed as –Sum of a series of.
For 3-G Systems Tara Larzelere EE 497A Semester Project.
ATF2 Q-BPM System 19 Dec Fifth ATF2 Project Meeting J. May, D. McCormick, T. Smith (SLAC) S. Boogert (RH) B. Meller (Cornell) Y. Honda (KEK)
EPOCH 1000 Series Software Update New Feature Overview July 2012.
Configuration Management, Logistics, and Universal CM Issues Larry Bauer Boeing Commercial Airplanes NDIA Conference Miami March 4-5, 2005
Group Meeting – Pepco Holdings, Inc. July 17, 2014.
EMBRACE Local Oscillator distributor EMBRACE (Electronic Multi-Beam Radio Astronomy ConcEpt) has been planned as about 300 square meters aperture array.
EPOCH 1000i Feature Overview Encoded and Timed C-scan
FAA/NASA Joint University Program for Air Transportation Research Jeff Dickman Chris Bartone June 20, 2003 A New Anechoic Chamber for Nearfield Antenna.
Quality Cost Quality Cost- those cost associate with the non achievement of product or service quality. Types Prevention Cost –Planning, Document, Control,
Implementing Baan PDM BWU – Orlando, FL October 17, 2001 Session 6 Chris Jamison RedKlay Web Solutions, Inc. PDM = Product Data Management.
EPOCH 1000 Series Procedure Linear Scan and C-scan.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
TelCal Phasing Engine description Draft Robert Lucas
Software Engineering Introduction and Overview Takes customer-defined goals and constraints and derives a representation of function, performance, interfaces,
FLAO system test plan in solar tower S. Esposito, G. Brusa, L. Busoni FLAO system external review, Florence, 30/31 March 2009.
Teaching and Learning with Technology to edit Master title style  Allyn and Bacon 2002 Teaching and Learning with Technology lick to edit Master title.
EPOCH 1000i Feature Overview Weld Overlay. Weld Overlay Display Feature.
Abstract The purpose of this project is to create a fully functional 8.5 meter radio telescope which can receive signals at a frequency of 1.42 GHz. The.
EPOCH 1000 Series Procedure Phased Array Angle Beam Calibration
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
July 19, 2006VLCW-06 Vancouver1 Scint/MAPMT Muon Prototype Operation Robert Abrams Indiana University.
IP BPM Shift Report FONT Meeting: 22 December 2014 Talitha Bromwich.
Fast Fault Finder A Machine Protection Component.
Speed Sensor Calibration
MDO4000C Series vs. Regular Scope FFTs Competitive Fact Sheet Benefits: ~20dB better dynamic range than a scope FFT RF support.
1/22 R. Long 1, P. Cawley 1, J. Russell 1,2 1. UK Research Centre in NDE, Imperial College 2. Rolls-Royce Marine, Derby.
Latest ROTOSCAN system development
Insert date here Presentation to 4 th PANI 3 Management Committee PANI 3 Results – Ultrasonic Results.
1 ATF 2 Nanobpm (Q BPM) Electronics. Mark Slater: Cambridge Yury Kolomensky, Toyoko Orimoto: UCB Stewart Boogert, Steve Malton, Alexi Liapine: UCL Mike.
19-Feb-16 “"Dana Confidential Information - Those having access to this work may not copy it, use it or disclose the information contained within this.
EPOCH 1000 Series Procedure Phased Array DAC/TVG.
Seismic Resolution of Zero-Phase Wavelets Designing Optimum Zero-Phase Wavelets R. S. Kallweit and L. C. Wood Amoco Houston Division DGTS January 12, 1977.
CAD CAM. 2 and 3 Dimensional CAD: Using 2-dimensional CAD software, designers can create accurate, scaled drawings of parts and assemblies for designs.
If you have a transaction processing system, John Meisenbacher
SPM Users Basic Training August 2010 Lecture VIII – AC Imaging Modes: ACAFM and MAC Imaging methods using oscillating cantilevers.
Roller Coaster Speed Sensor Calibration. Lab Safety  Do not stand on chairs, or sit or stand on the tables  Know the location of the first-aid kit 
FUNCTION GENERATOR.
Electronic Devices Ninth Edition Floyd Chapter 15.
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
DNP Initiative ENG-003 Standard Design Process Overview Configuration Management Benchmarking Group June 12, 2017.
MECH 373 Instrumentation and Measurements
INTRODUCTION TO Immersion Ultrasonics
MECH 373 Instrumentation and Measurements
Speed Sensor Calibration
How to Select a PNA IFBW with Performance Comparable to an 8510
What Is Spectral Imaging? An Introduction
Chapter 9 Design via Root Locus <<<4.1>>>
The performance requirements for DSP applications continue to grow and the traditional solutions do not adequately address this new challenge Paradigm.
Chapter 5: Active Filters
Update of BINDT FMC User Group
Presentation transcript:

Implementing TI Billet Phased Array on the Shop Floor By Mark Pompe, West Penn Testing Group Jeff Umbach, Pratt & Whitney Experience at West Penn Testing

Overview History of WPTG involvement with Ti Billet Inspection Comparison to Existing Multizone Inspection Implementation Of Phased Array at WP Lessons Learned Q & A

MultiZone Ti Billet at WP Sioux City Accident

MultiZone Ti Billet at West Penn Operated GE MultiZone system 1995 through 2004 First Production System installed after Initial RMI test bed Over 22 million lbs of rotor grade Ti billet were inspected Testing has transitioned to billet producers

MultiZone Ti Billet at WP 3 Separate Systems –Motion –Acquisition –Analysis

MultiZone Ti Billet at West Penn Billet followers held 4 to 7 MultiZone transducers

WPTG Phased Array Involvement Operating Phased array systems since 2000 on wrought product and Composites Volunteered to be a test bed for Ti Billet Phased Array Project in 2008

Modifications for PA trial at WP Modified Follower to hold 5” diameter Phased Array Transducer Re-configured MZ prototype gimbal, commercial gimbals too fragile, test can be violent with bent billets. Added auxiliary encoders for X axis and rotational position – Passive System

Modifications for PA trial at WP Follower/transducer configuration shown for start of billet scan The lead rollers are on the billet and the back rollers, not visible in the photographs, are not yet on the surface. Phased Array transducer

Why Consider Phased Array? Phased Array 5 min setup –One Transducer 6” to 10” Evaluation 2 C-scan images No over scan for rack of transducers Multi Zone 2 to 4 Hour Setup –3 sets of 4 to 6 transducers Evaluate 4 to 6 C- scan images 12” to 24” overscan

Alignment For Multizone Probes is on Billet Back Surface Reflection or FBHs Internal Ti Billet structure steers the beam off axis, normal to back wall is not normal to FBHs Can add hours to setup for 4 to 6 transducers

Alignment for Phased Array is performed on the billet front surface 9 elements of the transducer used to align the transducer on the surface of the sample Alignment completed in ~5 min time

Alignment is performed on the billet surface Mis-alignment in the circumferential direction is noted because on pair of elements is closer to the surface than the other pair.

Multizone Calibration Each Transducer is calibrated on a FBH at the start and end of the zone The two FBHs are equalized by Water Path Adjustment to within 3 dB. Complicated by difficulty in normalizing

Phased Array Calibration A DAC (TCG) is used in each zone with typical FBH standards The setup for 6” diameter inspection is shown Channel gain = 1 dB Sum gain = 42 dB Filter = 5 MHz band pass Channel gain = 2 dB Sum gain = 42 dB Filter = 5 MHz band pass

An acquisition file is made utilizing 7 sweeps to help guarantee that the backwall is sampled with the beam as normal as possible Gate on the backwall signal 7 sweep angles with the beams focused at the backwall Attenuation correction

49.2% is used for the attenuation comparison to the billet More Accurate Attenuation Comparison

PA Data Analysis Software automatically evaluates the C-scans for Amplitude and Signal to Noise Ratio Defects Similar to MZ

The automated software applies the criteria for both zones and displays the rejectable and reportable signals The table is also written to an Excel file with scan information to be used for a report

Excel file contains results from the automated analysis peaked values recorded by the operator

Lessons Learned P/A set up at WP on several occasions in 2010 on two systems, 6” and 10” Billet Encoder vs position Follower Stability –1/16 th to ±1/4 typical spec for Water Path –Best Possible for PA < 1/16”, you can see it in the data. Operator Training – prior c-scan experience – 2 operators were quick studies. Tomoview Software designed for engineers Procedures can be worked out for operators PW generating focal laws initially, need a source for this. Single Probe, Alignment and DAC dramatically reduces setup New Standards needed, can use simpler design

To Accomplish Implementation FAA approval (Beginning 4/2011) P&W specification RR, Honeywell Specifications AMS Specification for Generic Use Equivalency to AMS-2631

Cost Comparison MZ vs PA Instrumentation – MZ built and maintained by one source with 1990s components. P/A should have multiple sources (Olympus, Peak, others possible) Transducers – Phased Array is 1/3 rd of cost for 6” to 10”, –One Phased Array Probe vs 3 sets of 4 to 6 MZ probes. –Spares are needed for either. –Both single source (Same source), more expense to develop another source. Integration – Possible through inspectionware with peak instrument, Separate motion control and data collection/Analysis with Olympus. Followers – readily modify off the shelf units (Tac Tic for ours) vs complex custom builds Phased Array requires new calibration standards with additional FBHs Evaluation PC integrated with data collection pc, simplifies maintaining PCs, PCs are off the shelf running modern operating systems. Phased Array purchase price is lower, maintenance is significantly lower.

Q & A