Surge Protective Devices Chris Martin Sales Manager Surge Protection Devices.

Slides:



Advertisements
Similar presentations
Control Circuit Protection Supplementary Protectors vs
Advertisements

POWER QUALITY BACKGROUND & ELEC-SAVER TVSS
04/ Benefits of Using a Power Analyzer: Easily Identify Power Quality Issues Generate Detailed Reports Outlining Power Problems Utilize Smart Power.
CL100D series DSP controlled Uninterruptible power supplies.
BACKGROUND: We are finding an increase in instances where the available fault current at underground (UG) 1-phase residential service entrance equipment.
UNIT 31 HOME ELECTRICAL SYSTEM
LPC LPC LIGHTNING PROTECTION CRANES, LLC.
Static Transfer Switch
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
PRESENTED TO THE IEEE LONG ISLAND CONSULTANT’S NETWORK
2014 NEC Code Changes Ted “Smitty” Smith E Light Electric.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Emergency Lighting Code Review Presented by Iota Engineering LLC.
Startup Training – TPS3 15. Siemens TPS3 Startup Training 2 Topics Covered  Visual Inspections  Verify environmental requirements are met  TPS3 15.
Surge Protection: Technical Background & Basics. 2 Surge Protection – Agenda Introduction AC Power Basics Power Quality Scope Voltage Transients & Disturbances.
SPD’s Surge Suppression Devices GE Digital Energy.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
Electrical Power Systems
© 2011 Ericson Manufacturing, Willoughby, Ohio
Chapter 8 Output Modules.
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
Electrical Principles and Wiring Materials
Surge Protective Devices
White Papers – publication: IEEE PES Transactions – note these papers are not overly technical, may not be appropriate placement. T&D World – good audience.
Overvoltage protection (surge arrester)
Electrical Principles and Wiring Materials
Team Members: Advisor: Cruz, Jaime e. Dr. Paris Wiley
Generating and Using Electricity
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
Electrical Principles and Wiring Materials Unit #31.
Electrical Principles and Wiring Materials Unit #31.
Peter Brackett- Canadian Pacific Railway Robert MacMillan- CSX Railroad Earl Chapman – Railway Consultant, (previously CN) Keeping Signals Working What.
Smart Surge Protector Team Members Jason Long & Billy Gates, Jr. Professor Stephen E. Saddow, Advisor.
3-Phase Submersible Motor Control
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
Power Quality at the Plug Power Quality At the Plug
Utility Engineers, PC.  Generation  Transmission  Distribution.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
1 of 25 © 2007 Ideal Industries Power Quality At the Plug IDEAL INDUSTRIES Author: Patrick Elliott Application Guide to Power Quality.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
ELECTRICAL SAFETY FOR INSTRUMENTS SECTION. Electrical measurement safety Understanding hidden hazards and new safety standards.
Cat Electric Power Compact Diesel – Next Generation Product Launch
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Residential Wiring Unit 3 – Installation and Planning.
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
Introduction to Global AC Power
SPD II 1 for LV Power (AC/DC)
v1/2011 Strikesorb Protection Solutions
Introduction to Global AC Power
Introduction to Global AC Power
Mersen’s Fused Coordination Panelboard
Smitty’s Two Minute Drill Mixed Content -05
Agricultural Systems Technology II
Chapter Six Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and.
EET 323 – Electrical System Design Lecture 9: Grounding
MAIDA DEVELOPMENT COMPANY Recommended Products for the Lighting Industry (757)
Presentation transcript:

Surge Protective Devices Chris Martin Sales Manager Surge Protection Devices

80% - Internal Disturbances Load switching Variable frequency drives Lighting and air handlers 20% - External Disturbances –Utility load switching Smart grid –Lighting strikes Cloud to cloud Cloud to ground Cloud to man-made object Where surges originate

Isokeraunic Map

1.Cause disruptions in computer signals and processors 2.Degrade component junctions causing “random” delayed failure 3.Cause instant damage to electrical components Surge damage

How SPDs work Cross Section of a MOV Clamped Voltage (depends on surge level) Turn on Voltage (always the same) Source Load SPD Turn on Voltage Clamped Voltage 150v 1,500v 20,000v Eliminated Voltage

UL nd Edition nd Edition 2005 Revision (effective 2/9/2007) Expanded OVERVOLTAGE Testing (2 x nominal voltage) Added 7 hour intermediate fault current levels 10 amps 100 amps 500 amps 1000 amps SPD manufacturers pass this new requirement by either adding fusing per MOV, thermal sensing technology, or requiring an external OCPD for the safe removal of the SPD

Surge Current Impulse Duration (Microseconds) Indef. 20 microseconds5000 microseconds 20 mm MOV Surge Current Rating Curve At 20 micro-seconds the MOV can protect up to 6500Amps (1 time) at 5000 micro-seconds that same MOV can only protect up to 30Amps

UL rd Edition Creates SPD types (Type1, Type2, Type3, Type4) –Surge Arrestor, Lightning Arrestor, TVSS New Nominal Discharge Surge Current test, I n Thermal “stress” test Tested MCOV per mode. No longer a claimed value SVR 6kV, 500A replaced with VPR 6kV, 3kA Surge Arrestor incorporated into UL1449 as Type 1 device

SPD Types - UL rd Ed. Type 1 SPD (LINE SIDE) Permanently Connected SPD – Installation between the secondary of the service transformer and the LINE side of the service disconnect over current device, as well as the LOAD side, including watt-hour meter socket enclosures. (Not exceeding 1000V) Secondary Surge Arrestor Competitors Surge Arrestor Needs a breaker to pass UL testing

SPD Types (Continued) Type 2 SPD (LOAD SIDE) Permanently Connected SPD intended for installation on the LOAD side of the service disconnect over current device, including SPDs located at the branch panel.

SPD Types (Continued) Type 3 SPD Point of utilization SPDs, installed a minimum of 10 meters (30 feet) from the electrical service panel, for example cord connected, direct plug-in (DPI), receptacle type and SPDs installed at the utilization equipment being protected.

SPD Types (Continued) Type 4 SPD Component SPDs, including discrete components as well as component assemblies. (Note: as proposed the 3rd Edition will allow Type 4 SPDs to be tested and applied where Types 1 and 2 are allowed)

Measured Limiting Voltage (MLV) All SPD Types are to be tested to 6kV/3kA - 3 pulses per mode with applied voltage. VPR is determined by averaging results. (Per 34.9 and Table 34.1) SVR 6kV/500A Good reading 400v or 500v VPR 6kV/3kA Good reading 700v, 800v, 900v, or as high as 1000v Higher surge current results in higher clamping voltages

Type 1:Choose 10kA or 20kA/Mode Type 2:Choose 3kA, 5kA, 10kA, or 20kA Surge unit at chosen surge value Apply chosen over voltage to unit within 1s for 1min Nominal Discharge Current Test (I n )

2008 NEC COPS - Critical Operations Power Systems –NEC guideline to increase protection and reliability of the power infrastructure for critical facilities What are Critical Facilities? –Government agency (Federal, state, municipal) –Facility engineering –Facilities that if destroyed may disrupt: National security, the economy, public health, or safety To include –HVAC, fire alarm, security, communications, and signaling

2008 NEC NEC Section (D) Surge Protective Devices must be used to comply SPDs must be used for each voltage at the facility –Service Entrance –Distribution panels

Improving SPD Installed Performance How does lead length affect the installed performance of a surge protective device? Does an internally mounted SPD outperform an externally mounted SPD? Impact of upstream OCPDs

How are SPDs Tested? 6 inches outside of the enclosure The surge is injected here Clamping characteristics are recorded by an Oscilloscope Phase length + Neutral length affect the performance of the SPD

The surge must travel through the phase through the SPD and through Neutral Phase length + Neutral length = SPD clamping voltage Internally Mounted Lead Length

Lead Length Lead length affects the installed performance of a SPD 10’ sections of cable (commonly used sizes) –14 AWG –10 AWG – 6 AWG Apply IEEE defined 20kV/10kA surge Measure the voltage drop

Wire size Voltage drop across 10 foot cable when exposed to a 20kV/10kA surge – 14 AWG 2,650v – 10 AWG 2,400v – 6 AWG 2,350v What does this do to the installed performance of the SPD?

Lead Length Impact

The Low Impedance Cable

HPI Voltage Drop Voltage drop across 10 foot cable when exposed to a 20kV/10kA surge –10 AWG 560v – 6 AWG 560v

Lead Length Impact 83% improvement

Breaker Impact Does a breaker upstream of an SPD limit the effectiveness of the SPD? Breakers have surge trip and surge failure values: The SCCR value is based on 60Hz current, not surge current! Type 2 SPDs must be installed behind a breaker! These values are based on testing performed by Current Technology’s Surge generator on commercially available off the shelf breakers.

The ISM Integrated Suppression Module

ISM Design Utilizes TPMOV technology Bus Bar construction N-G filter (removable) Improved L-N Filter 100% surge rated Reduced weight Individually monitored MOVs Advanced monitoring 300kA Model

The TPMOV Thermal spring Barrier 50mm MOV DRC switch DRC contacts Barrier spring

Select3 (SL3) Listed by UL to UL rd Edition as a Type 1 SPD 50kA, 100kA, 150kA, 200kA, 250kA, 300kA per mode TPMOV/Selenium Hybrid –Option for enhanced selenium Test reports for single and repetitive surge testing Surge rated disconnect with line side barrier DTS-2 internal test port option 6 levels of monitoring 20 year warranty THE SERVICE ENTRANCE SURGE PROTECTOR OF CHOICE

TransGuard3 (TG3) Listed by UL to UL rd Edition as a Type 1 SPD 50kA, 100kA, 150kA, 200kA, 250kA, 300kA per mode TPMOV Technology RoHS compliant Test reports for single and repetitive surge testing Surge rated disconnect with line side barrier DTS-2 internal test port option 6 levels of monitoring 15 year warranty

Panel Extension (PX3) Listed by UL to UL rd Edition as a Type 1 SPD 50kA, 100kA, 150kA, 200kA per mode 9 inch height for 50kA-100kA units TPMOV Technology RoHS compliant Test reports for single and repetitive surge testing DTS-2 internal test port option 6 levels of monitoring 15 year warranty

DTS-2 Tester The ONLY proactive test kit for SPDs on the market Updated test card for both MOV and TPMOV based products with or without selenium Validates “health” of surge components Compares installed clamping performance to original factory values Detects and provides early warning for stressed components Can be used to evaluation competitive products performance Part of any startup or commissioning Validates integrity of upstream Xo bond

M1 Standard Monitoring LED indication per phase Audible alarm Alarm silence switch 2 sets of dry relay contacts Tri-colored LED that reports on % protection –Green = 75% or greater –Orange = 75% - 40% –Red = 40% or less –Extinguished = Loss of protection

M2 Monitoring Option All M1 monitoring options Surge counter

M3 Option New Mastermind Includes all M1 monitoring features Time/Date stamp Duration and Magnitude User settable thresholds Tracks –Sags, swells surges, dropouts, outages, THD, frequency, Volts RMS, % protection Local character display ModBus remote communications M4E Option New Mastermind Includes all M1 monitoring features Time/Date stamp Duration and Magnitude User settable thresholds Tracks –Sags, swells surges, dropouts, outages, THD, frequency, Volts RMS, % protection Local character display ModBus and Ethernet remote communications Web based interface

M5 Option Adds Large Graphics Display Includes all M1 monitoring features Time/Date stamp Duration and Magnitude User settable thresholds Tracks –Sags, swells surges, dropouts, outages, THD, frequency, Volts RMS, % protection Local character display ModBus remote communications M6E Option Adds Large Graphics Display Includes all M1 monitoring features Time/Date stamp Duration and Magnitude User settable thresholds Tracks –Sags, swells surges, dropouts, outages, THD, frequency, Volts RMS, % protection Local character display ModBus and Ethernet remote communications Web based interface

Review Specs need to be Updated to include new requirements outlined in UL rd Edition Externally mounted SPDs offer a safer installed alternative without affecting performance External OCPDs can have an affect on the installed performance of the SPD Ask for documentation. Single surge, repetitive surge, and tested MCOV value Questions?