STANDARD ON WATER SUPPLIES FOR SUBURBAN AND RURAL FIRE FIGHTING

Slides:



Advertisements
Similar presentations
Classification of Building Construction Types
Advertisements

Determining the Occupant Load
Basics of Fire Sprinkler Design
Qualified Live Fire Instructor Review.
Advanced FF Strategy Semester Review FIP 221 Fall 2011.
Arkansas Fire Academy Structure Fires IV. Arkansas Fire Academy Structure Fires IV Introduction of Instructors.
Portland Fire Train Derailment Planning and Training.
Section IV Foam Application and Operations
NFPA 1142 Pre-burn Plans - House Layout - Fireground Layout - Hazard Mitigation - Permits Minimum Total Gals Required Minimum GPM For Flow Minimum Total.
Chapter 3.1 Storm Drainage Sizing. Building Drain & Sewer  Building Drain —That part of the lowest piping of a drainage system that receives the discharge.
IRC 2009 Habitable Attics.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
Pumping Apparatus Driver/Operator
NFPA Chapter 6 Chapter 6 is used to classify the occupancy and the hazard contents Proper classification is used to guide the implementation of.
Total Flooding Systems
Presented by: Blaine W. Rabe’ Division Manager for the Property Insurance Association of Louisiana.
Chapter 3.1 Storm Drainage Sizing. Building Drain & Sewer  Building Drain —That part of the lowest piping of a drainage system that receives the discharge.
1 Math Questions. 2 Length x Width x Water Depth = cubic feet.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Intermediate Math WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Foam Application Rates for E85 and E-95. Application Rates Described in Terms of the Amount in Gallons of Foam Solution Reaching the Total Square Footage.
1 Module 5: Fire Fighting Foam Principles and Ethanol-Blended Fuel.
3-1 NFIRS 3 Structure Fire Module. 3-2 ObjectivesObjectives The participants will be able to: –describe when the Structure Fire Module is to be used.
Standard for the Organization and Deployment of Fire Suppression Operations, Emergency Medical Operations, and Special Operations to the Public by.
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
Purpose of Standpipe and Hose Systems
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Residential Fire Sprinkler Systems. Goal Provide entry level firefighters with an understanding of residential fire sprinkler system Provide entry level.
Types of Fire Apparatus
Fire vs. Water Flow. What’s the best size for an “attack line?”  Maximum flow  Maximum mobility  Speed-How fast and how much  Ease of deployment and.
NFPA 13: Installation of Sprinkler Systems
PREINCIDNET PREPARATION. OBJECTIVES Properly calculate required fire flow for structures using the National Fire Academy Fire Flow Formula. FIRE FLOW.
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
OBC 2009 CHAPTER FIVE GENERAL BUILDING HEIGHTS AND AREAS.
Fire and Emergency Services Company Officer — Lesson 17 Fire and Emergency Services Company Officer, 4 th Edition Chapter 17 — Preincident Planning.
Occupancy Classification Under NFPA 13 Examine the proposed facility and make recommendation on the Occupancy Classification Used to classify fuel loads.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Tindale-Oliver & Associates, Inc. National Impact Fee Roundtable Public Safety Impact Fees and Alternatives – Fire Flow Methodology Robert P. Wallace,
NFPA 1710 Standard for the Organization and Deployment of Fire Suppression Operations, Emergency Medical Operations and Special Operations to the Public.
Fire Service Pump Operator ch 02 Types of Fire Apparatus
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Needs Analysis Full-Time Staffing Levels Michael A. Walker, Fire Chief.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Identify the unique construction factors of single-family dwellings. Recognize the basic problems.
Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural.
Objective Calculate the amount of materials needed for a construction project.
SIZE-UP The systematic process consisting of the rapid, yet deliberate, consideration of all critical fire ground factors that leads to the development.
Exit Routes and Fire Protection
Volume of Solids(2) Today’s lesson will cover… finding volume of cylinders and cones finding volume of cylinders and cones using formulas to solve problems.
Sprinkler Loads on Trusses
FIRE COMMAND 1A Incident Command Project. SYNOPSIS: While operating at a residential structure fire, three firefighters experienced a catastrophic floor.
Types of Fire Apparatus Equipped with a Fire Pump Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
This training meets the WAC Annual Training Requirements. This training does not qualify for NWCG Annual Wildland Refresher, such training must.
Washington Surveying & Rating Bureau  Who Are We?  What Do We Do?  How Does Insurance Rating Promote Sprinkler System Installations and What Obstacles.
Sprinkler Design FSE 221 – Fire Protection Systems
Water Shuttle Operations
Medium- and High-expansion Foam System Design
First To Arrive Duties Training Union County SOG 3.12.
Carbon Dioxide System Design
Review-Definitions 4.5 Division – (“Division Supervisor” shall be the title utilized to describe this appointment) Established to divide an incident into.
2013Q1.
NFPA 5000 Occupancy Classifications
Direction water flow Notes: Occupancy type is PUBLIC The WCs (toilets) are public flush valve.
Harry R. Carter, Ph.D., MIFireE Municipal Fire Protection Consultant
NOVA MANUAL TRAINING TOWNHOUSE June 2009
Find: y1 Q=400 [gpm] 44 Sand y2 y1 r1 r2 unconfined Q
NFPA 101 Occupancy Specific Requirements
Ambulatory Health Care vs. Business Occupancy
NFIRS 3 Structure Fire Module
Presentation transcript:

STANDARD ON WATER SUPPLIES FOR SUBURBAN AND RURAL FIRE FIGHTING

WATER SUPPLY DETERMINING FACTORS EXTENT OF EVOLUTIONS SIZE OF and TYPE OF STRUCTURE CONTENTS METHOD OF ATTACK EXPOSURES RESERVES

NFPA 1403: 4.2 Structures and Facilities 4.2.23 The lead instructor shall determine the rate and duration of water flow necessary ..., including the water necessary for control and extinguishment of the training fire, the supply necessary for backup lines to protect personnel, and any water needed to protect exposures.

NFPA 1403: 4.2 Structures and Facilities 4.2.23.1 The minimum water supply and delivery for the live fire training evolutions shall meet the criteria identified in NFPA 1142, Standard on Water Supplies for Suburban and Rural Fire Fighting.

Definition: 4.1.5 (1) Exposure Hazard STRUCTURE WITHIN 50 FEET and 100 SQUARE FEET OR LARGER. (2) If class 3 or 4 OH, within 50 ft of another building, it is considered an exposure hazard regardless of size. What is an exposure really? (Anything that we don’t want to damage)

CLASSIFICATION OF OCCUPANCY HAZARD Chapter 5 CLASSIFICATION OF OCCUPANCY HAZARD WHAT OCCUPANCY TYPE IS THE MOST LIKELY TO BE USED IN LIVE FIRE TRAINING?

Occupancy Hazard Classification 7 5.2.5.1 Light hazard occupancy NFPA 1142 5.2.5 Occupancy Hazard Classification 7 5.2.5.1 Light hazard occupancy Dwellings

Classification Of Construction 6.2 .... structures shall be classified by type of construction and shall be assigned a construction classification number.

Dwellings Classification Of Construction 6.2.1 Type V (Wood Frame) Construction Classification Number 1.5 Dwellings

FOR ALL EXPOSURE HAZARDS MULTIPLY TOTAL BY: Chapter 4 Minimum Water Supply = (TOTAL CUBIC FT) x (CONST CLASS OCCUP 1.5) x ( Exp. Factor 1.5) (CLASS # 7) PER 1142 - FOR ALL EXPOSURE HAZARDS MULTIPLY TOTAL BY: 1.5

NFPA 1142 4.2 SINGLE STRUCTURES WITHOUT EXPOSURE HAZARDS (2000 gal. minimum) 4.3 SINGLE STRUCTURES WITH EXPOSURE HAZARDS (3000 gal. minimum)

NFPA 1403 50% Reserve SINGLE STRUCTURES WITHOUT EXPOSURE HAZARDS (3000 gal. minimum) SINGLE STRUCTURES WITH EXPOSURE HAZARDS (4500 gal. minimum)

Determining Minimum Water Supplies 4.6 The fire department shall develop the capability to deliver the amount of water determined in accordance with Sections 4.2 through 4.5 to the incident scene at the rate shown in Table 4.6.1

Total Water Required: Rate Capability: Table 4.6.1 Total Water Required: Rate Capability: < 2,500 2,500 - 9,999 10,000 - 19,999 > 20,000 250 500 750 1,000 Table put back in the 2007 edition Was an exception in 2002 (old 1231)

What if the exposure is larger than the structure being burned? Calculate water supply based on the larger structure

Multiple Exposures? NCFRC Exception Add .5 for each Exposure Example: 2 Exposures 1.5 1st Exposure + .5 2nd Exposure 2.0 Exposure Factor

3 Exposures = 1.5 + .5 + .5 = 2.5 (1) (2) (3) 4 Exposures = 1.5 + .5 + .5 + .5 = 3.0 (1) (2) (3) (4)

Determining Minimum Water Supplies Go back to NFPA 1403: 4.2.23.2 A minimum reserve of additional water in the amount of 50 percent of the fire flow demand in 4.2.23.1 shall be available to handle exposure protection or unforeseen situations.

Practice Time! See if your calculations are the same! (Remember – calculate gable roofs as ½ the height from the attic floor to the ridge pole)

50% additional reserve per NFPA 1403: 11,573 Total Gallons Exposure 50’ 50 x 24, 2 stories with gable roof, 8’ from attic floor to ridgepole 2 story w/gable roof 8’ ceilings 8’ to ridgepole 24’ 50 X 24 = 1,200 square ft. Height = 8 + 8 + 4* = 20’ 1,200 x 20 = 24,000 cubic ft. (Dwelling) Exp. OCCUP HAZ CLASS = 7 (divide by 7) 3429 GAL. CONST CLASS = 1.5 (multiply by 1.5) 5144 GAL. Go to Table 4.6.1 Table 4.6.1 shows: 500 GPM Must be capable of flowing 500 GPM for about 15 minutes. (7715 gal / 500GPM) 50% additional reserve per NFPA 1403: 11,573 Total Gallons 1 EXPOSURE HAZARD (multiply by 1.5) 7715 GAL. Exposure

65’ 1 story w/gable roof 8’ ceilings 8’ to ridgepole 30’ Dwelling Exp. 65’ x 30’ = 1,950 square ft Height = 8’ + 4* = 12 ft. 1,950 x 12’ = 23,400 cubic ft 1 story w/gable roof 8’ ceilings 8’ to ridgepole 30’ OCCUP HAZ CLASS = 7 (divide by 7) 3343 GAL. CONST CLASS = 1.5 (multiply by 1.5) 5014 GAL. Exp. Go to Table 4.6.1 750 GPM Flow for about 14 minutes (10,029 gal / 750 GPM) Dwelling 2 EXPOSURE HAZARDS (multiply 1 + .5 + .5) 10,029 Gallons 50% additional per NFPA 1403: 15,044 Total Gallons Exposures

52’ 44’ 2 story w/ mansard roof 10’ ceilings Dwelling 36,772 Gallons 52’ x 44’ = 2,288 square ft Height = 10’ + 10’ + 10* = 30’ 2,288 x 30’ = 68,640 cubic ft Exp. 52’ 44’ 2 story w/ mansard roof 10’ ceilings OCCUP HAZ CLASS = 7 (divide by 7) 9806 GAL. CONST CLASS = 1.5 (multiply by 1.5) 14,708 GAL. Exp. Exp. Dwelling Go to Table 4.6.1 1000 GPM Flow for about 37 minutes (36,772 gal / 1000 GPM) 3 EXPOSURE HAZARDS (1.5 + .5 + .5 = 2.5) 36,772 Gallons Exposures 50% additional per NFPA 1403: 55,158 Total Gallons

Remember! Calculate Square Footage Calculate Cubic Footage Occupancy Hazard Class Construction Class Exposure factor Required GPM Minutes Flow Sustained 1403 Reserve