Full-scale Reflective Cracking Test Update Presented to: FAA Airport Pavement Working Group Meeting By: Hao Yin, Ph.D., P.E. Gemini Technologies, Inc. Date: April 24, 2012
Acknowledgement FAA Dr. Satish Agrawal Dr. Gordon Hayhoe Donald Babargallo Ryan Rutter Frank Petch Murphy Flynn SRA Chuck Teubert Jerry Connelly Renaldo Aponte Jeff Stein Gupta Durgesh David Traverzo Pochtar Daniel Bing Xiao Henry Fermin RMD Roy McQueen Christopher Deker
Generate information from full-scale tests (NAPTF) to assist in the improvement of current design procedures for AC overlay on rigid airport pavements. Objective
Evaluate the initiation and propagation of bottom-up reflection cracks due to temperature effect acting alone (thermally induced fatigue), assuming intact PCC slabs. Scope Nunn, M., 1 st RILEM 1989
1. Pavement Temperature: T=32 o F, T=17 o F Key Parameters
2. Horizontal Displacement at Joint: 15 mils Key Parameters
3. Loading Rate ? 4. AC-PCC Interface Bond ? Key Parameters
Progress Since 2011 Laboratory tests Construction, instrumentation, and data collection Temperature Effect Simulation System (TESS) tune-up and enhancements Trial test
Texas Overlay Tester Temp: 32 o F Max Hori Dip: 15 mils Loading Rate: 0.25, 0.50, 1.0 mil/sec Determination of Loading Rate
Overlay Tester Results 0.05
Interface Bond Experiment steel rakeheavy broom Straight Asphalt Emulsion
Bond Strength Test Temp: 32 o F Loading Rate: 0.05 mil/sec
Bond Strength Test
PG Straight Asphalt and Heavy Broom Bond Strength Test
Temperature Unit Re-design
P-401 (PG 64-22) Subgrade P-209 (Dense Graded Aggregate) P-501 5” 12” P-501 8” 6” Pavement Construction
Instrumentation Layout ASG/CSG T 1.5’ TTT T T T 12.0’ L L L L L L North South Surface SG
Data Collection
Mishap Before Overlay South North
N S E W Force, 92,000 lb Force -85,000 lb Mishap After Overlay -46 mil 56 mil Ten Com
N S E W Ten Com Mishap After Overlay
Crack Arrester
Trial Test Feb 27 – March 15 AC/PCC interface temperature: 32 o F Max Hori Dis: in 600 sec per cycle 144 cycles per day Total of 2641 cycles
Hydraulic Control
Hydraulic Control – Cont.
Hori Dis Along Joint NorthSouth
Pavement Temperature
Crack Development 36 Cycles
Crack Development 180 Cycles
Crack initiation
Dynamic Modulus 430,000
Temperature: 14 o F Loading Rate: 8 mil/sec (0.5 in/min) Tensile Strength Lab = 500 psi Buttlar et al Tensile Strength Field = 200 psi Tensile Strength: Field vs. Lab
Crack Development 280 Cycles
Actuator Force
Crack Development 2641 Cycles 17” 37.5”
Surface SG Response
Embedded SG Response
Future Activities Experiment instrumentation Mill existing AC and overlay Full-scale test Laboratory tests Fracture energy of AC Creep compliance of AC Tensile strength of AC Thermal Coefficient of PCC
Image Recording - North
Image Recording - South