Hexagon Metrology By: JHorwell Sr. Metrologist July 2013

Slides:



Advertisements
Similar presentations
Verification of specifications and aptitude for short-range applications of the Kinect v2 depth sensor Cecilia Chen, Cornell University Lewis’ Educational.
Advertisements

Laser Speckle Extensometer ME 53
New Non-Contact, Laser-Based Gauge for Measuring Length and Speed of Gypsum Board Stuart Manser Beta LaserMike.
Purpose of this Minilab
Introduction Radiostereometry (RSA) is well established research method for assessing movement of orthopaedic implants, bone fractures, and.
CHAPTER 7 ANGLE MEASUREMENT
Reflection in Plane Mirrors Reflection in Plane Mirrors Objectives: Investigate reflection in plane mirrors Verify the “1st Law of Reflection” Compare.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
CE 260 SURVEYING CHAPTER 5.
LHC Collimator Survey Train Concept / Development / Status Patrick Bestmann CERN BE/ABP/SU IWAA /09/2010 Remote Controlled Measurements in the LHC.
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
Introduction to Precision Metrology
 The reliability of analytical data generated from chemical and physical analyses is critically dependent on three factors: 1. Validity of the analytical.
Reconfigurable Inspection Machine (RIM). NFS Engineering Research Center for Reconfigurable Manufacturing Systems College of engineering, University of.
Prepared by Mahmoud F. Elbatta Ahmad Alyazgi Amjad Alaskary Akram abo Twahina Roshdi tambora.
DELTA Quadrant Tuning Y. Levashov, E. Reese. 2 Tolerances for prototype quadrant tuning Magnet center deviations from a nominal center line < ± 50  m.
Manufacturing Engineering Department Lecture 9 – Automated Inspection
Visual Angle How large an object appears, and how much detail we can see on it, depends on the size of the image it makes on the retina. This, in turns,
LINEAR MEASUREMENT.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
AUTOMATED INSPECTION (Part 2).
LASER AND ADVANCES IN METROLOGY
Integral University EC-024 Digital Image Processing.
EBD existing crane details and future bridge crane upgrade Alev Ibrahimov June
H. MAINAUD DURAND PACMAN WP1 OUTLINE Tasks & role of associated partner Plans for training.
1 ELEC 3105 Basic EM and Power Engineering Start Solutions to Poisson’s and/or Laplace’s.
Precision Layout Unit 21.
Modern Optics Lab Lab 6 Part 2: Interference Experiments  Observe interference by plane-parallel plates: Measure the thickness of the plates based on.
Eusoballoon optics test Baptiste Mot, Gilles Roudil, Camille Catalano, Peter von Ballmoos Test configuration Calibration of the light beam Exploration.
Magnification Calibration Interlaboratory SEM Study: Part 1.
Freiburg 7/07/20001 laser beam lens CCD (long arm) screen + grid CCD (short arm) glass plates at  45° STAMP : Saclay Telescope for the Alignment of Many.
How to startpage 1. How to start How to specify the task How to get a good image.
: Chapter 11: Three Dimensional Image Processing 1 Montri Karnjanadecha ac.th/~montri Image.
Study Lesson 5 Pictorial sketching.
Laser-Based Finger Tracking System Suitable for MOEMS Integration Stéphane Perrin, Alvaro Cassinelli and Masatoshi Ishikawa Ishikawa Hashimoto Laboratory.
The HESSI Imaging Process. How HESSI Images HESSI will make observations of the X-rays and gamma-rays emitted by solar flares in such a way that pictures.
Straightness measurement
Measuring Instruments
Perspective Drawings Linear perspective is a geometric method of representing the apparent diminishing of scale as the distance from object to viewer increases.
1 of 175 Focus 3D X 130 and X 330 Laser Scanners SCENE 5.3 September 2014.
Train Body The next series of slides will guide you through the construction of the train body. Start a new drawing and save it as Train Body.
1 Point Perspective Students will tape down a piece of paper and go through the steps As we go through the presentation.
Mathematical Vocabulary
Company LOGO Technology and Application of Laser Tracker in Large Space Measurement Yang Fan, Li Guangyun, Fan Baixing IWAA2014 in Beijing, China Zhengzhou.
Silicon Bulk Micromachined Hybrid Dimensional Artifact Characterization Meghan Shilling Sandia National Laboratories NCSLI 2009 July.
1 Setting Laser Power and PMT Gain Begin with laser power at 20% Set PMT gain to 6.00.
Midterm Review 28-29/05/2015 Progress on wire-based accelerating structure alignment Natalia Galindo Munoz RF-structure development meeting 13/04/2016.
NCSLI 2007 In House Capability of an Optical CMM Calibration for any Company Shawn Mason Boston Scientific.
TE-MSC. 07/04/2016 Jose Ferradas TE-MSC-MDT Alejandro Carlon TE-MSC-MDT Juan Carlos Perez TE-MSC-MDT On behalf to MSC-MDT section and Coil working group.
H. MAINAUD DURAND on behalf of the CLIC active pre-alignment team oWPS versus cWPS OUTLINE Introduction oWPS cWPS Results of inter-comparison tests
CSIR National Metrology Laboratory Your measurement technology partner for global competitiveness.
Light as a ray Reflection. No light, no sight In darkened room, eyes to observe, brain to decipher, objects appear black Light reflects off of objects.
Digital Light Sources First introduced in 2001.
UNIT-I SLOTTING MACHINES
Recent developments on micro-triangulation
ELEC 3105 Basic EM and Power Engineering
Stages for the SSW translation system for PACMAN
Speed Sensor Calibration
MultiView 400™ Product Presentation Nanonics MultiView 400™
THEODOLITE TRAVERSING BY S N Nanaware
S. Ghosh, M. Muste, M. Marquardt, F. Stern
Name: Ansari Kaushar Ali
MEASUREMENT AND INSPECTION
T. J. Okamoto (NAOJ/Kyoto Univ.)
Christopher Deufel, Michelle D. Wang  Biophysical Journal 
Microscopy.
Purpose of this Minilab
MIRRORS Chrome text with reflection (Advanced)
Volume 105, Issue 10, Pages (November 2013)
Presentation transcript:

Hexagon Metrology By: JHorwell Sr. Metrologist July 2013 Alternate Method to Certify Grid Plates and Line Scales using a CMM with Chromatic Confocal Sensor verses Traditional Methods Hexagon Metrology By: JHorwell Sr. Metrologist July 2013

What may I Learn or Why Listen? Alternate method for certifying Line Scales How to apply a white light confocal sensor for edge detection Difference between displacement and intensity Density of the data Selection Criteria 2013 NCSLI International Workshop and Symposium

01 Brief History 02 03 04 05 06 Overview of Requirements Test Piece AGENDA Overview of Requirements 01 Brief History 02 Test Piece 03 Results 04 05 Error Budget 06 Lessons Learned 2013 NCSLI International Workshop and Symposium

Test the ability of a confocal chromatic sensor to find edges Overview Test the ability of a confocal chromatic sensor to find edges Review existing Hexagon Hardware and firmware to accomplish this task Compare distance measurements against certified artifact Determine the feasibility to certify grid plates and glass line scales on a high accuracy CMM with confocal chromatic sensor 2013 NCSLI International Workshop and Symposium

Some have combinations of manual and automatic systems History Currently most line scales are measured on special purpose hardware consisting of an XY stage, Laser Interferometer feed back for position and an optical measuring device Others use comparative techniques from a certified master scale to the scale under test Some have combinations of manual and automatic systems In the past some used high accuracy CMM with an image analysis system to certify grid plates 2013 NCSLI International Workshop and Symposium

200mm Glass Scale with Chrome Lines Task is to be able to find the edges with a standard deviation less than 0.09um Calculate the distances and compare these to a certified value. 2013 NCSLI International Workshop and Symposium

Equipment Selection Criteria Small Measurement Uncertainty ≤ 0.3 + L/1000 Non Contact Sensor Availability Stability over time Hardware, Software and Firmware available and capable for finding edges 2013 NCSLI International Workshop and Symposium

LSP –S4 Probe head with integrated optional Precitec LR Sensor Leitz PMM C 12107 Infinity Measuring Error MPE in [µm] according to ISO 10360-2 (2010-6) E0 ≤ 0.3 + L/1000 E150 ≤ 0.5 + L/1000 R0 ≤ 0.3 Scale Resolution 4nm LSP –S4 Probe head with integrated optional Precitec LR Sensor 2013 NCSLI International Workshop and Symposium

Precitec LR Sensor Fully Integrated into Leitz PMM C Infinity Numeric aperture 0.66 Measuring procedure chromatic confocal Measurement angle relative to surface 90° ±40° Measuring distance 6.5 mm Diameter of measuring spot 1.4 µm 2013 NCSLI International Workshop and Symposium

90 degree Sensor We are continually developing sensors and adaptors for our systems The sensor to the right is similar to the sensor we used but can measure the line scales in the vertical direction verses horizontal The sensor can be manually rotated and our controller can handle more than one sensor on a single system 2013 NCSLI International Workshop and Symposium

Overview Glass Line Scales Find the edges of a Chrome Lines on Glass Line Scales using the Precitec LR Chromatic Confocal Sensor on the Leitz infinity 12107 in RI Build a reference system on the Glass Scale using tactile probing Build an alignment system using the Precitec LR Sensor Measure each reference line via 3-pts and constructing an axis Intersect each reference line with the alignment axis Calculate the distance from each line to the zero line and compare with certificate of certification Test 2-methods for finding the edge Test alignment stability Run repeat test to determine standard deviations 2013 NCSLI International Workshop and Symposium

Test Part – Glass Line Scale Certificate of Calibration No 115-01538 by CIPM MRA Uncertainty of Measurement: U = 0.10µm + L/2000 The distances between the graduations were measured with a photo mask measuring system consisting of a precision x-y bearing table, a two-axis differential plane mirror interferometer and a microscope. The table moves the graduations to the focus of microscope while the interferometer measures its position. The relative position of a graduation within the field of view the microscope is determined by digital image analysis. The scale was cleaned, supported at the Bessel-points (distance 121mm) and measured with the graduation on top using episcopic white light illumination. For each graduation the position of the trailing edge was measured at the height of the collinear alignment marks 2013 NCSLI International Workshop and Symposium

What was missing from the hardware configuration While we could find the edge of the lines using traditional analysis by automatically finding extreme points with a standard deviation between 112nm and 250nm using a 30 repeat test. We determined that these values were not as good as we believe our equipment was capable up. Our Firmware Development Group made a flag within our firmware that allowed us to receive the intensity out verses displacement from the Precitec LR Sensor This was the break thru that we needed to accomplish our task 2013 NCSLI International Workshop and Symposium

Alignment & Fixture Procedure For Glass Scale The Glass Scale was place on 3-spherical pins which were near the airy points with 2 at one level and a single pin at the other airy point. 2-posts were used to align the scale along its axis and a single pin for the stop on the zero end plane of the Glass Scale Tactile alignment Using the LSP-S4 probe head and ruby sphere probe we measured a plane on the top and long side and a single point on the end face. This provided us with the rough alignment before we picked the Precitec LR Sensor from our Probe Change Rack Optical Alignment Scanned two lines on the top surface of the Glass Scale, constructed a plane and defined the Z-axis spatial vector and alignment from that. We measured 3-points on the line between the 0 and 10mm lines and constructed axis Measure same on the last line between the 190 and 200mm marks Constructed an axis from these two points which define the rotational portion of our Coordinate system Measured 3-points and constructed an axis on the back side of the zero line at ±0.5mm from the axis just created Intersected this zero line axis with the line the defined the rotational portion of our Reference System and this became the X-zero of our Glass Scale 2013 NCSLI International Workshop and Symposium

Alignment of Glass Scale using Precitec LR Sensor 10 190 200 Found 3-edge points at ±0.5mm from zero alignment axis on the 0-position vertical line and built an axis and the intersection of that axis and the zero alignment line created the XY origin Found 3-edge points at 0.5mm spacing on each of the 2-horizontal lines and constructed an axis between then which defined the axial alignment 2013 NCSLI International Workshop and Symposium

Measurement Sequence We started our measuring sequence by measuring the Zero Line using 3-points; constructing an axis and intersecting the newly measured axis with the directional axis of our reference system and got a single point for each line measured. We basically stepped and repeated this process until all lines were measured We then calculated the distance in X-direction between each line measured and the Zero Line. We repeated this process 10 times 2013 NCSLI International Workshop and Symposium

Finding the edge What are some of the issues with finding the real edge and then correlating this to traditional methods. Edge is not perpendicular to the reference plane Edge is not straight Does back lighting verses top lighting give two different edges Can we find the same edge as traditional optical systems and measuring microscopes 2013 NCSLI International Workshop and Symposium

Finding extreme points on the edge Edge Detail 2013 NCSLI International Workshop and Symposium

Summary of Results 2013 NCSLI International Workshop and Symposium

Current procedure The 3 slides following this show the results from finding the edge of a single chrome line using ScanOnLine with the following point spacing: 0.0001 = 10,000pts/mm 0.00005 = 20,000pts/mm 0.000025 = 40,000pts/mm I am hoping to have even lower standard deviations that I originally obtain using the Precitec LR sensor on Infinity Currently I am finding the edge by selecting points based on light intensity of 0.26 to 0.35 When I am on the chrome surface I get saturation which is near a value of 1 2013 NCSLI International Workshop and Symposium

Finding the Edge Alignment Line Top picture illustrates the edge as seen by the CMM system in red The blue line is the change in intensity as the system crosses the edge The small red points on top of the blue line are the points used to define the edge based on intensity value. Lower picture shows the measured edge from the CMM in Red The line in black shows the intensity curve from the Crocodile box. The change in intensity is from glass surface to the silver plated surface 2013 NCSLI International Workshop and Symposium

Intensity Points Selected Density at 10,000pts/mm Chrome Surface Glass Surface Measured Curve Intensity Points Selected Scan Direction 2013 NCSLI International Workshop and Symposium

Results The red line represents average value from 10 repeats – the certified value. I did not apply temperature compensation at the moment but could and most likely will. The Blue dots represent the results from the 25 runs 2013 NCSLI International Workshop and Symposium

Results - numerical 2013 NCSLI International Workshop and Symposium

Noise reduction algorithm affects the edge detection! Still not Satisfied! Noise reduction algorithm affects the edge detection! 2013 NCSLI International Workshop and Symposium

Raw Data From CMM with out Noise Reduction 2013 NCSLI International Workshop and Symposium

Selection based on Intensity Data Shown has NO Noise Reduction The points inside this window represents selected data based on intensity: Blue = 0.5 to 0.6 Intensity Blue + Red = 0.5 to 0.71 Intensity The points inside this window represents original selection for intensity: Green = 0.5 to 0.6 Intensity 0.26 to 0.35 1µm Intensity range Location (mm) 0.5-0.6 79.999732 0.5-0.71 79.999760 0.26-0,35 80.000352 2013 NCSLI International Workshop and Symposium

Selection based on Intensity Data Shown has NO Noise Reduction The original testing presented in this paper used the 0.26 to 0.35 intensity selection criteria and noise reduced data from the CMM We wanted to test raw data with no noise reduction and a steeper point on the intensity curve. Selected 0.5 to 0.6 Intensity Selected 0.5 to 0.71 Intensity Results are taken weeks apart with completely new setups and the standard deviations for this newest procedure has a maximum σ of 0.55µm 2013 NCSLI International Workshop and Symposium

Intensity Selection Comparison Effect of Intensity Selection Distance Sigma (mm) Δ Cert (um) (mm) 0.5-0.6 0.5-0.7 0.26-0.35 10.0 0.000024 0.000014 0.000025 -0.15 -0.14 -0.11 20.0 0.000036 0.000039 0.000053 -0.06 -0.05 -0.03 30.0 0.000047 0.000042 0.000046 -0.22 -0.21 -0.20 40.0 0.000043 0.000040 0.000049 -0.26 -0.25 50.0 0.000038 0.000051 0.000061 60.0 0.000044 0.000041 0.000056 -0.08 70.0 0.04 0.05 0.02 80.0 0.000066 2013 NCSLI International Workshop and Symposium

Straightness Plot of the Scan (YZ plane) 2013 NCSLI International Workshop and Symposium

Verification results are equal in the + and – Scan Direction 2013 NCSLI International Workshop and Symposium

Verification results are equal in the + and – Scan Direction 2013 NCSLI International Workshop and Symposium

Optiv Performance 2z443 Standard Scale Resolution Measuring Error MPE in [µm] according to ISO 10360-7 EX , EY ≤ 2.2 + L/125 Standard Scale Resolution 0.5µm Optional Scale Resolution 0.1µm 2013 NCSLI International Workshop and Symposium

OPTIV Results [2.2 + L/125]µm 2013 NCSLI International Workshop and Symposium

Error Budget Environment 20°C±0.1°C 10%CTE of 8.3*10-6/°C = 0.016µm Reproducibility – actual 25 repeats plus realignment = 0.083µm CMM Accuracy Parallel to X extrapolated from physical measurements [0.2 + L/1500]µm Other considerations Quality of edge Squareness of measured lines to center axis UC = [0.3 + L/1000]µm with coverage factor of 2 2013 NCSLI International Workshop and Symposium

Summary We wanted to show that one could calibrate a Glass Line Scale and or a grid plate via a non traditional method such as presented within this paper. We hope that the community will consider this alternate method and hope to engage in some round robin testing to verify that a high accuracy CMM with chromatic confocal sensor could be used and that is process could allow users to verify their working standards without the need for special purpose systems. It also adds validity for owning instruments of this caliber. We are not claiming that this method is faster than a tradition non-contact CMM, but we do feel that we can reduce the measurement uncertainty for calibrating longer artifacts with a significant lower measurement uncertainty and without the need for a dedicated single purpose system. 2013 NCSLI International Workshop and Symposium

Quality of the edge has a significant impact to our standard deviation Lessons Learned It is possible to find an edge using a chromatic confocal sensor using only displacement Light intensity changes are a better method to find the edges than using displacement values only Quality of the edge has a significant impact to our standard deviation Use of noise reduction algorithms has some impact on the standard deviation, but changing the selection criteria had very little impact Correlation to alternate calibration methods are easy to reach with the Leitz Infinity with integrated Precitec LR chromatic confocal sensor 2013 NCSLI International Workshop and Symposium

The End Thank you! 2013 NCSLI International Workshop and Symposium