Proper Pump Installation Practices

Slides:



Advertisements
Similar presentations
Unit Seven: Pumps and Compressors
Advertisements

BeginningNext SlideBack End Program AVADAL 1 of 18 SK-16 Main Pumps 4 Pumps Per Strand – Normally 2 running and 2 on standby as back-up. Motor is 60 HP.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Unit Eight Check Valves, Cylinders, and Motors
References Which were useful? Sources Fluid Power with Applications; Anthony Esposito Basics of Hydraulic Systems Qin Zhang Hydraulic and Pneumatics.
Fluid Power Symbols.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Hydraulic Valve, Pump, Motors
Simple Pressure Control Valves
Unit Nine Flow Control Valves
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
Turbine Protection and Control System
Basics of Pump Vigyan Ashram, Pabal.
COMPRESSOR BASICS.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Reciprocating pump Pumps are used to increase the energy level of water by virtue of which it can be raised to a higher level. Reciprocating pumps are.
Hydraulics For The Long Term
Muhajir Ab. Rahim School of Mechatronic Engineering
1 Fuel Pumps. 2 Pumps 1.All oil burners for residential heating have pumps A. They are connected to a motor through a coupling 2.Description A. An oil.
Oilgear Pump Controls PVWJ, PVG, and PVV.
Components of Centrifugal pumps
Water piping design.
HVAC523 Circulator Pumps.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
To prevent cavitation:
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Hydraulic Symbols. Piping and Tubing Symbols Normal working line Flexible working line Pilot line Drain line Enclosure outline Direction of flow.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
HYDRAULICS & PNEUMATICS
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Introduction to Energy Management
Introduction to Oilgear Pumps
OILGEAR PVV PUMPS PVV 200 Performance Curves.
PVWC Hydrostatic Pumps. PVWC Hydrostatic Pump Features Control Selection –Mechanical Pintle w/o neutral by-pass (M-N)
PVG PUMPS. PVG Pumps Currently 5 Displacements – 048 ml/rev (2.93 in ³) – 065 ml/rev (3.94 in³) – 075 ml/rev (4.60 in ³ ) – 100 ml/rev (6.00 in ³ ) –
PVK Pumps. PVK Pump Features Controls are Easily Field Convertible. –By using pilot control modules (PCM’s) for various control functions.
PVWC Hydrostatic Pumps. PVWC Hydrostatic Pump Features Control Selection –Mechanical Pintle w/o neutral by-pass (M-N)
PVWH Pump Presentation. PVWH Pumps n 10 Displacements –. 66 in³/rev –.86 in³/rev –1.35 in³/rev –1.55 in³/rev –2.06 in³/rev –2,83 in³/rev –3,88 in³/rev.
Kaeser Rotary Screw Vacuum Packages
Submitted by Pradeep pataskar Roll no.11031M02034.
GUJARAT TECHNOLOGICAL UNIVERSITY (GTU) Mahatma Gandhi Institute Of Technical Education and Research Center, Navsari Affiliated with GTU Presentation on.
Chapter 3 – Hydraulic Pumps
Hydraulic Pressure Control
Air Compressors Capacity Horsepower Pressure Duty Cycle.
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,
Unit Twelve Pilot Operated Pressure Control Valves At first glance the diagram would appear to show three different valves but the box surrounding the.
HYDRAULIC OVERSPEED CONTROL
CENTIFUGAL PUMP OPERATION
Introduction Danfoss hydraulic motors convert hydraulic energy (pressure and oil flow) into mechanical energy (torque and speed). Danfoss hydraulic motors.
Components Pumps.
HYDRAULIC & PNEUMATIC CIRCUITS
COMPRESSOR BASICS.
14 Refrigerant Recovery, Recycling, and Recharging.
Troubleshooting Hydraulic Pumps
Cylinder Cushioning mechanism
OBJECTIVES Describe the operation of a pressure-differential switch and a brake fluid level sensor switch. Describe the operation of a residual check valve.
Basic principles of hydraulic symbols
Oilgear Specific Controls Training
SB Packing Automatic Downpuller Power Unit
Trouble Shooting Hydraulic System Failure
FAILURE ANALYSIS A Guide to Analyzing Axial Piston Pump Failures
Hydraulic Pressure Control
Pumps and Lift Stations
Game Tutorial, How it works
Game Tutorial, How it works
COMPRESSOR BASICS.
Hydraulic Flow Control • Metering Fluid Flow
Presentation transcript:

Proper Pump Installation Practices

There is a Reason Every Unit Comes With This Bright Orange Tag !

Proper Alignment and Coupling Installation Do Not Drive Coupling Onto Shaft Pump Alignment Must be .005” TIR Make Sure Coupling Halves are Not Touching *Can Induce Thrust load and Misalignment Use Keyed Shaft for Industrial Applications *Oilgear Standard Splines are Designed to be Loose *Do Not Use Split Spline Couplings

Coupling Installation Do Not Drive Coupling Onto Shaft!

Bearings are Designed to Carry Side Loads Not Thrust Loads Driving on a coupling or coupling halves touching -Creates a thrust load, damaging balls and race’s of front bearing. Thrust Load Side Load

Pump Alignment: TIR Means Total Indicator Reading Perpendicularity Concentricity

Effect of Misalignment Cylinder Not Parallel with Valve Plate Side Load

Split Couplings Can Cause Misalignment Splines are Free to Self Align Splines are Not Allowed to Self Align

Case Drain Lines Lines Must be Full Size Lines Must be Unrestricted Lines May Not be Connected to Other Return Lines Lines May Not be Connected to Filters, Coolers Lines Must be Plumbed so that Case Remains Full at All Times Lines Must be Terminated Below Oil Level

Case Slip Increases When Unit Strokes PVG “C” Frame Stroke = .750” On Stroke Response = 40 ms Off Stroke Response = 50 ms Amount of Flow Being Drained to Case On Stroke = 15.16 GPM Off Stroke = 20.18 GPM Add in Pump Leakage Full Stroke Leakage, On Stroke = 4 GPM Compensated Leakage, Off Stroke = 7 GPM Total amount of flow that must be accelerated through case drain line. On Stroke = 19 GPM Off Stroke = 9.018 GPM Note: Calculations on this slide are for visual illustration purpose’s only. On Stroke Area .518 in 2 OP-6 Off Stroke Area 3.14 in 2

Case Slip Increases When Unit Strokes Continued Flow across OP-6 must be added in when going off stroke. When oil is ported to off stroke side of piston it also bleeds to tank through this orifice. The pressure on that side of the piston will go to whatever it needs to in order to move the piston. System pressure could be seen for a short period of time. Let’s use 3750 psi - 3750 psi across .081” dia orifice = About 11 GPM. This flow is not added in when going on stroke as that side of the piston is open to tank. New Totals On Stroke = 19 GPM Off Stoke = 20.018 20 GPM Has to be Accelerated Through Case Drain Line When Pump Shifts Note: Calculations on this slide are for visual illustration purpose’s only. On Stroke Area .518 InSq OP-6 Off Stroke Area 3.14 InSq

Case Spike While Pump Comes Off Stroke 101 PSI Spike PVG -065 with 5/8” case drain - 20 feet long 42 PSI While Compensated Pressure Comp Set @ 3300 PSI 1500 PSI Pump Fully Compensated @3300 PSI Pump Starts to Compensate @ 3200 PSI

Effects of Case Pressure Shaft Seal Failure *Standard Seal Rated to 25 PSI Gasket Failures Piston Shoe Swashblock Failure *Shoe Lift

Shoe Lift Case pressure is an added force acting on shoe faces wanting to separate shoes from swashblock. Force acting on piston wants to separate shoe from swashblock on suction side, force varies with rpm, stroke and inlet condition. Shoe lift occurs when combined forces overcome fulcrum ball spring.

Shoe Lift Occurs Due to Case to Inlet Differential Limits

Flow Meter in Case Drain Line Not Recommended, But if You Must Put a full size ball valve in parallel with the meter. Ball valve should be open during Normal Operation. Close the valve to check case slip when needed. This does 2 things: 1) It Protects the Pump From Case Spikes. 2) It Saves Wear and Tear on the Meter When the Pump is Cycling

Cooler in Case Drain Line Not Recommended, But if You Must 3 PSI Put a 3 PSI check valve in parallel with cooler to protect pump from case spikes.

*Away From Return Lines Inlet Conditions Inlet Lines Should be Full Size Inlet Lines Should be Unrestricted and as Short as Possible Inlet Lines Should Have a Minimum of Fittings and Elbows Inlet Location *Away From Return Lines *Proper Reservoir Baffling Suction Strainers are Not Recommended *If Required Size for 3 Times Pump Volume

Inlet Sizing on Variable Displacement Pumps is Critical PRESSURE REQUIRED @ PVG-130 INLET STEADY STATE MIN. INLET REQUIRMENT 1800 RPM = 11 PSIA LOSS THROUGH 2.5” PIPE WITH ONE ELBOW = APPROXIMATIVELY .3 PSI PRESSURE @ THE INLET @ SEA LEVEL 14.4 PSIA PRESSURE REQUIRED WHILE COMING ON STROKE @ 50 MS SAME LOSS DUE TO PRESSURE DROP = .3 PSIA ADDED LOSS DUE TO ACCELERATING THE COLUMN OF FLUID IN 50 MS = 2.46 PSIA PRESSURE @ THE INLET WHILE PUMP COMES ON STROKE IN 50 MS @ SEA LEVEL = 11.9 PSIA The above is under best of circumstances on oil. Even with that we are approaching the cavitation point of the pump. Many things contribute to inlet requirement, such as Fluid Type, Line Length, Any Inlet Restrictions, RPM, Elevation.

Inlet Sizing on Variable Displacement Pumps is Critical IF THE HIGH RESPONSE TIME IS NOT REQUIRED YOU CAN MAKE THIS CONDITION BETTER PVG-130 WITH RESPONSE SLOWED TO 200 MS SAME LOSS DUE TO PRESSURE DROP = .3 PSIA ADDED LOSS DUE TO ACCELERATING THE COLUMN OF FLUID IN 200 MS = .7 PSIA PRESSURE @ INLET WHEN PUMP COMES ON STROKE IN 200 MS @ SEA LEVEL = 13.7 PSIA This condition allows a little more room for other added losses such has Heavier Fluids, Longer Line Lengths, Higher RPM, Elevation.

Proper Reservoir Design

Be Aware of Pump Inlet Characteristics

Fast Acting Relief Fast Acting Relief Always Recommended Pressure Compensators Not Meant to Act as System Relief *Flow is Still Being Delivered to the System While Pump is Coming Off Stroke Relief Should be Set 300 PSI Above Compensator Setting

Spike Generation No Relief 5300 PSI Spike Pressure Comp. Set @ 3300 PSI 2000 PSI 30 ms Pump Still Generating Flow While Coming Off Stroke. Without a Fast Acting Relief That Flow Creates a Spike.

Spike Generation With Relief Pressure Comp. Set @ 3300 PSI 3600 PSI Spike 2100 PSI 30 ms Fast Acting Relief Dumps Excess Flow Which Clips Off Spike

Filtration Use Minimum 10 Micron Filters Use By-Pass Filters With Indicators Off Line Filtration Preferred Keep Fluid to Recommended ISO Level

Start Up Make Sure Tank is Full of Fluid Make Sure All Shut off Valves are Open Fill Case Completely Before Operating Check for Proper Rotation *Rotation is Referenced Looking at Pump Shaft Provide a Means of Purging Air From Discharge Line Back Out Pressure Compensator and System Relief Jog Motor if Possible

Following the proper installation procedure directly relates to the success of the application and the life of the pump. Thank-You