FIPTMV Medium Voltage Technology

Slides:



Advertisements
Similar presentations
Medium-Voltage Switchgear - Then and Now -
Advertisements

Industrial Controls: Surion
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
Inspection & Preventive maintenance of breakers
We thought it was a GOOD IDEA, so we did it! We were the first to have quick make-quick break operators on bolted pressure contact switches.
Co-ordination of LV Protection Devices
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Premset : A New generation of MV Switchgear
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
OHB Outdoor sulphur Hexafluoride circuit-Breaker
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
October, 2009 VM1: innovation in power technology Vacuum circuit-breaker with magnetic actuator Product presentation 1VCP – Rev. C, en – Presentation.
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
24 kV GIS Switchgear for Secondary Distribution
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
MV SF6 circuit-breakers for secondary distribution
EE4503 Electrical Systems Design
Multi-function apparatus for secondary distribution
Medium Voltage Switchgear
WFR-12~24 Product presentation
Medium Voltage Fuses. 2 Why do we need Medium Voltage Fuses? Medium Voltage fuses are used the protection for voltage transformers and medium voltage.
The Northern California Section of the Instrumentation, Systems, and Automation Society Smart Positioners – Features n Mario Francisco – CFM Inc The TZID-C200.
EPIC© - Extended Performance Impervious Ceramic Metal to Ceramic Weld Superior to Gasket or O-Ring Seal More Durable than Epoxy Seal (EV200) Hermetic Seal.
Pole Mounted Switch Disconnector NPS
MNS Sprint - A Market Driven Solution
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
All rights reserved Gas-insulated Switchgear (GIS)
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
A low - cost high performance MV RMU with circuit breakers for use in remote controlled MV / LV substations Fabio GIAMMANCO Luca GIANSANTE 1 1.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Medium Voltage Outdoor Apparatus Portfolio
SF6 load break fault make switches for overhead networks
PowerIT Air Insulated Cubicle Uniswitch
Disconnector Switches and Earth Switches
Switchgear for Primary Distribution
HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ
How selected hoist overload limiter. How should hoist overload limiter Selection Electric hoist is a motor, reducer and rope reel (or chain) as one of.
Gas-insulated switchgear type ZX0
SEMINAR PRESENTATIon ON C IRCUIT B REAKER DEPT. OF ELECTRICAL ENGG. JALPAIGURI GOVT. ENGG. COLLEGE PRESENTED BY Madhusudan Mahato Malay Ghosh.
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Sectos NXB and NXBD.
© Copyright, HQT-SV Control System
Sensor presentation.
Name, department/event, date
Overview of PowerCube Units and ANSI frames
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
SION Vacuum Circuit-Breaker For Standard Applications
Oil-tight MV fuse CEF-OT with TPC bushings
ELECTRICAL POWER-II Electrical engineering sixth semester
Incompatibility between MV Switchgear conforming TO the international standards and their use in DNO’s substations M. Arens – Y Tits – Belgium – Session.
All rights reserved Gas-insulated Switchgear (GIS)
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
ALTERNATIVE CURRENT & VOLTAGE SENSORS
Secondary Gas Insulated Switchgear
Presentation transcript:

FIPTMV Medium Voltage Technology SFG Top Unit

Main applications of the SFG The SFG is a standard component in the Uniswitch MV switchgear worldwide ...up to 24kV ...up to 1250A ...up to 25kA

Uniswitch construction 1) Busbar compartment 2) The SFG switch disconnector 3) Cable compartment 4) Operating device, interlocking device and low voltage compartment

The SFG TopUnit 3-position indoor switch disconnector Extremely durable operating device with optional tripping and motor operation Epoxy resin enclosure with inspection windows

The SFG TopUnit at a glance A compact SF6 -gas insulated indoor switch disconnector Rated voltage 12-24 kV Rated current 630-800 A SFG TopUnit dimensions: Length: 835 mm Width: 375 and 500 mm Weight: about 40 kg 3 positions: closed - open - earth

SFG Construction Gas compartment is sealed for life (EN 50187) 3 positions: closed - open - earth 2 windows for visual position inspection Earthing switch with full making capacity Magnetic blow type arc eliminator Integrated capacitive divider for voltage indication

SFG TOP UNIT - features Safety: Made to highest IEC standards, non corrosive leak proof enclosure, inspection windows, integrated voltage indicator, interlocking device, gas gauge, etc. Economy: A life span of minimum 30 years, sealed for life, low maintenance costs Reliability: Stringent testing of each unit, extremely durable and reliable actuator, worldwide use, etc. Smart integration: Modular construction, compact size, easy installation, one switch - many applications

SFG TopUnit - Inspection windows Provides the possibility to visually check the switch position

SFG TopUnit - Single spring mechanism Compact, economical and durable construction Minimum number of parts Sealed for life Stainless steel and aluminium Three positions in one device 1 operation shaft as standard, 2 shafts as an option Optional motor operating device Patented position indicator Easy to install

SFG TopUnit - Double spring mechanism Fuse tripping function. Trip coil and emergency pushbutton as option Compact, economical and durable construction Three positions in one device 1 operation shaft as standard, 2 shafts as an option Motor operating device as a build-on option Patented position indicator Easy to install

SFG TopUnit - Accessories Operating mechanism: 1-spring or 2-spring manual or motorized operation 1 or 2 operating shafts Remote control Key interlocking device Gas pressure gauge Fuse base and tripping Mechanical position indication Etc.

SFG TopUnit - Ratings Rated voltage (kV) 12 17,5 24 Rated lightning impulse withstand voltage, BIL common value (kV) 75 95 125 across the isolating distance (kV) 85 110 145 Rated short-duration power-frequency withstand voltage common value (kV) 28 38 50 across the isolating distance (kV) 32 45 50 Rated current (A) 800 800 630 Mainly active load breaking current 100 CO operations (A) 800 800 630 Making capacity (3-times) (kA) 62,5 50 50 Short circuit current, 3s (kA) 25 20 20 Breaking capacity, IEC 60265-1 (A) 1530 1260 920 Max fuse (A) 125 100 80 Mechanical endurance of switch (c/o) 5000 5000 5000 Mechanical endurance of earthing (c/o) 1000 1000 1000 Rated filling pressure (gauge) (bar) 0.4 0.4 0.4