Introduction to FLUID COPLING.

Slides:



Advertisements
Similar presentations
Training Presentation
Advertisements

Engine Cooling And Lubrication
3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
ADX 150 – Engine Repair ADX 170 – Climate Controls
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Unit Eight Check Valves, Cylinders, and Motors
Cooling Tower Maintenance Training.
How Differential works
Propulsion Train & Shaft Line Components
Compressors CM4120 Julie King.
Section 4: Electric Motors
"AIR COOLER" Heat Exchanger
COMMERCIAL REFRIGERATION
HVACR 317 – Refrigeration Core
Function, Construction and Operation
Boone County ATC Diesel Technology DIT150: Powertrain Mr. Hillenbrand Spring 2015 Torque Converters.
Couplings Nizwa College of Technology.
Senior Design: Validation of Design December 15, 2008.
Goulds ISO Series ISO End Suction Centrifugal Pump
Fluid Coupling Torque Multiplication
Hydronic Mechanical Controls
© 2015 Cengage Learning. All Rights Reserved. May not be scanned, copied, duplicated, or posted to a publicly accessible website, in whole or in part.
New Mexico FFA Agricultural Mechanics Career Development Event Engine Power.
Components of Centrifugal pumps
HVAC523 Circulator Pumps.
Dr. subhash technical campus
UNIT 18: APPLICATIONS OF MOTORS
Sci 701 Unit 6 As learned in Unit 5: Speed, Power, Torque, and DC Motors, a motor can generate a set amount of power. Introduction to Gears Since there.
Connecting and Using Implements with the Tractor Set 5 Marissa Morton SAAIP.
C.R.ENGINEERING COLLEGE
Flat Saw Training. Flat Saw Sizes –Low Horsepower Blade diameters range from 8” (200mm) to 18” (450mm) Power ranges from 4 to 25 horsepower.
Electric Motors Applications of Motors North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed., CMHE Motors - 1.
SUBJECT CODE NAME OF SUBJECT TOPIC :::::: FLUID POWER ENGINEERING CENTRIFUGAL PUMP Parul Institute of Engineering & Technology.
Automotive Chassis Systems, 5/e By James D. Halderman Copyright © 2010, 2008, 2004, 2000, 1995 Pearson Education, Inc., Upper Saddle River, NJ All.
HYDRAULIC MOTORS.
Mechanical drive mechanisms
Parul Institute of Engineering & Technology Subject Code : Name Of Subject :Fluid Power Engineering Topic :Rotodynamic Pumps.
Texonics Proposal for Production Line Redesign and Retrofit.
9 Drive Shafts and CV Joints.
Refrigerant compressors Akshay Kr Mishra Sharda University 4 TH YR. MECHANICAL.
The Cooling System (Reasons for)
Prepared By Rohit G. Sorte M.Tech
Air Cylinders Convert the energy contained in the compressed air
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
SUDHIR REDDY S.V.R M.TECH(CAD/CAM)
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
TROUBLESHOOTING ELECTRIC MOTORS
Copyright © 2010 Delmar, Cengage Learning. ALL RIGHTS RESERVED. Unit 36 Electric Motors, Drives, and Controls.
Engine Cooling Systems
Temperature Test Allows monitoring of temperature changes.
Chapter 11 - Keys, Couplings and Seals
Selecting Electric Motors
Automotive Engines Theory and Servicing
Unit III Class II Pneumatic actuators.
Automotive Heating And Air Conditioning
Parts Pinion Drive Gear: transfers power from
YPPC’s Metallic MAG. DRIVE Process Pumps Product Overview.
DIFFERENTIAL UNIT.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Trouble Shooting Hydraulic System Failure
OBJECTIVES After studying Chapter 9, the reader should be able to:
Couplings.
How Differential works
TROUBLESHOOTING ELECTRIC MOTORS
Prof. H. D. Mhatre BELT DRIVE Prof. H. D. Mhatre Prof. H. D. Mhatre.
VG INSTALATION & MAINTENANCE.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Automotive Engines Theory and Servicing
Presentation transcript:

Introduction to FLUID COPLING

CONTENTS – FLUID COUPLING Basic Principle Structure Feature Operation Principle Installation Method Disassemble Method Operation & Maintenance Manual Trouble Reason & Countermeasure Installed Photos

1. Basic Principle ► Basic Principle 1) Fluid couplings are developed by Dr. 훼팅거 at 1905 in German. - Refer to Figure 1. Two fans are facing each other and when one fan is operating, the other fan is turning. - Refer to Figure 2. The impellers are attached to the input side are arranged to face each other. Fills the interior has a certain amount of oil as the power transmission medium. The spinning impeller attached to the input side, the oil therein is a collision of the outer impeller wings by centrifugal force, and the kinetic energy is transfered. <그림1> <그림2>

1. Basic Principle ► Basic Principle X 100 Since the power delivered by only the oil without mechanical combination. so It does not occur abrasion. The transfer torque is determined by speed of input side, oil amount and circuit's diameter. Slip occurrence is essential to functioning of the fluid, and can not be a power transmission without slip. Apply in Slip rate 1.5%~ 6% range. <그림1> Input speed–Output speed Slip rate(%) = X 100 Input speed <그림2>

1. Basic Principle ► Video for Basic Principle <화면클릭시 재생됩니다.>

2. Structure (HF, CHF)

2. Structure (HFF, CHFF)

2. Structure (CHF Disassemble) <화면클릭시 재생됩니다.>

2. Structure (HFF Video) <화면클릭시 재생됩니다.>

3. Feature Fluid coupling Features 1) Standard type When occuring shock loading, Fluid coupling can protect Motors and driven equipment. Because there is no mechanical connection. Using general motors instead of expensive special motors. - Reverse rotation is possible to stop the driven. 2) Chamber type Fluid couplings can control starting torque to prevent damage to the belt of conveyor belt.

4. Operation Principle ► Flow changes after starting ► STOP 0 1800 0 1800 450 1800 1760 1800 0 0 ► Flow changes after starting ► STOP

5. Installation (HF, HS, HP) ► Fluid coupling is mounted on motor shaft using 2 spanners with screws. ► Prohibit shrinkage fitting in order to prevent damage of inside Seal. ► Axis machining requires TAP. ► For safety and long life of the equipment to fit eccentricity, declination and the gap.

5. Installation (alignment) ► In case of using at the equipment of more than 1500rpm, apply only 50% of eccentricity and declination. . ► Install eccentricity, declination and gap in accordance with below table.

5. Installation (HFF, HG) 1) HFF - TYPE 2) CHHF - TYPE ► At HFF & CHFF Type, Flange coupling and Flange are installed at MOTOR side and associated machine. ► Must be injected into oil or grease at the contact surfaces for the correct installation. ► Pay attention to may cause damage to Flange of Flange coupling when shrink fitting.

5. Installation (Injection of Oil) ► After installation the casing is rotating for facing up. ► At first lightly fixed coupling, and open the opposite plug to be pulled out of the air inside the circuit. And inject oil until it overflows out of the oil inlet. ► Loctite is pasted to the plug to prevent leakage oil during operation. . ► If you do not know the injection point. standard (H-type)“0” Chamber type (CH-type)“2 ”

6. Disassemble ► Disassemble FIXING SCREW. ► First, you must remove the oil pulling plugs on the both sides. ► Disassemble FIXING SCREW. ► Disassemble the bolt assembly from Fluid coupling. ► Disassemble Fluid coupling by shaft using a jig. Refer to table beside. ► Don't hit the bolts and the body of the fluid coupling by hammer during disassemble.

7. Operation & Maintenance ► If frequent movement does not exceed the maximum exothermic temperature is 90 °. ► If you want to operate at a higher temperature conditions, please contact us. ► Excessive heat causes - Lack of oil - Driven machine' power is higher than rated power of the motor. - Ambient temperature is too high or The long start-up time. ► After 20days from the initial operation you check oil amount and locked state of fixing bolt. . ► Periodically check Shaft alignment of Fluid coupling. ► Fusible plug is 145 ° is standard. please contact us if you need Fusible plug for 175 ° or 120 ° ► Replace the oil at about 4000 hours of operation.

8. Trouble Reason & Countermeasure Oil leaking Seal damage by dirty oil. shrinkage fitting when assembling the input side. Seal Replacement Fluid coupling overheating Unsuitable standard selection. Lack of oil amount. Overload. Selecting suitable standard. Oil supplement. Remove overload causes. Fluid coupling noise & vibration Bearing damage. Unfit Centering. Poor of driving part’s bed. Bearing replacement. Re-centering. Bed drive reinforcement. ► Please contact the manufacturer for overhaul of Fluid couplings. .

Application of Fluid couplings < Steel material Bucket in POSCO > < Coal material Bucket in TAEAN Thermal Power Plant >

Application of Fluid couplings <TAEAN Thermal Power Plant> <Tile manufacturer>

Application of Fluid couplings <Incheon airport 5#> <Incheon airport 2#>

Application of Fluid couplings <Agitator for vitamin material in BASF> <Agitator>

Application of Fluid couplings <Tower Crane>

Application of Fluid couplings <Lift in Ski resort>

ขอบพระคุณครับ