Time-of-Flight at CDF Matthew Jones August 19, 2004.

Slides:



Advertisements
Similar presentations
1 Electronics Simulation in the Photon Transport Monte Carlo Preamp model Receiver/discriminator circuit CAFÉ driver circuit model Examples Summary January.
Advertisements

COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Particle interactions and detectors
Photomultipliers. Measuring Light Radiant Measurement Flux (W) Energy (J) Irradiance (W/m 2 ) Emittance (W/m 2 ) Intensity (W/sr) Radiance (W/sr m 2 )
1 TOF Aging Issues Pre-history Operating history Observations related to gain loss Impact on timing resolution Possible courses of action April 6, 2006.
SANE S pin A symmetries of the N ucleon E xperiment SEEN THROUGH THE EYES OF JOHN GERMAN MASTERS STUDENT FROM NORTH CAROLINA A&T STATE UNIVERSITY. JUNE.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
INFN of Genova, Pavia and Roma Flavio Gatti, PSI, February 9 th, Timing Counter status Timing Counter status.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Transducers Converts one type of energy into another. Light  Electrical (current, voltage, etc.) What characteristics should we look for in a transducer?
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
Stephen KahnParticle ID Software Mice Collaboration Meeting Page 1 Particle ID Software Steve Kahn Brookhaven National Lab 27 March 2003.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
MB1 T.O.F. II Precise timing Electron ID Eliminate muons that decay Tracking devices T.O.F. 0 & I Pion /muon ID precise timing 201 MHz RF cavities Liquid.
RPC (Resistive Plate Chamber)
Scintillation Detectors
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Tanja Horn, CUA PHYS 575/675 Modern Detectors Phys 575/675, Spring 2012 Tools of High Energy and Nuclear Physics Detection of Individual Elementary Particles.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Catania VLVnT09 Athens, Greece 1/14 Catania Performances of four super bialkali large area photomultipliers with respect to.
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
1 TOF Aging Discussion Background information Summary of results so far Examples of gain loss mechanisms Diagnostics Possible scenarios for 2006 Discussion.
Scintillators, DAQ boards, and PMTs Getting Familiarized With the Equipment By Melissa Sussmann and Alex Bonnifield.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Monday, Mar. 7, 2005PHYS 3446, Spring 2005 Jae Yu 1 PHYS 3446 – Lecture #12 Monday, Mar. 7, 2005 Dr. Jae Yu Particle Detection Ionization detectors MWPC.
Time of Flight Counter BESIII International Review Sep. 16, 2002 Heng Yuekun
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
1 Methods of Experimental Particle Physics Alexei Safonov Lecture #11.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
V0, jyg, ALICE week, March Preparing for the V0 TDR (Lyon-Mexico project)  The V0 detector in 3 chapters  1 - Tests and simulations of detection.
The Electromagnetic Calorimeter – 2005 Operation J. Sowinski for the Collaboration and the Builders Indiana Univ. Michigan State Univ. ANL MIT BNL Penn.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Time of Flight Detectors at RHIC Time of Flight Measurements at RHIC  TOF detector as a PID devices  PHENIX-TOF and BRAHMS-TOF PHENIX Time-of-Flight.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
A Brand new neutrino detector 「 SciBar 」 (2) Y. Takubo (Osaka) - Readout Electronics - Introduction Readout electronics Cosmic ray trigger modules Conclusion.
Photon Transport Monte Carlo September 27, 2004 Matthew Jones/Riei IshizikiPurdue University Overview Physical processes PMT and electronics response Some.
Design of Time zero(T0) counter contents Characteristic of p+p collision Time of Flight method Systematic scintillator performance Scintillator selection.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Scintillation Detectors in High Energy Physics
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
Scintillation Detectors
Methods of Experimental Particle Physics
PAN-2013: Radiation detectors
Status of the TOF Detector
Chris Smith California Institute of Technology EPS Conference 2003
Neutron Detection with MoNA LISA
Department of Physics and Astronomy,
Deng Ziyan Jan 10-12, 2006 BESIII Collaboration Meeting
Scintillation Counter
Photomultiplier (PMT) Tubes
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Time-of-Flight at CDF Matthew Jones August 19, 2004

History An experimental TOF system installed in CDF at the end of Run-I: –Covered only 5% of the acceptance –Demonstrated feasibility –Identified potential problems Contributions to Run-II TOF system from several institutes: –Cantabria, FNAL, INFN, Korea, LBL, MIT, Penn, Tsukuba

Introduction Tracking chambers only detect stable, charged particles: P T measured by curvature in B field Extra information needed for particle ID: –Ionization of material –Cherenkov techniques –Time-of-Flight –Shower shapes –Transition radiation These measure  e/h separation

Measuring  t How well we can measure  t determines how well we can distinguish between the two particles. Detector Production point

Time-of-Flight Achievable resolution is of order 100 ps.

Measuring TOF Important issues: –Precision: K/  separation or cosmic veto? –Detector technology: Scintillator + PMT Resistive plate chambers –Segmentation: occupancy vs channel count –Cost per channel

Detecting charged particles Charged particles lose energy in material: Example: 1 MIP = 2 MeV/cm

Plastic Scintillator Ionization  excited molecular states  electrons are loosely bound Ionization excites the S 0 electrons Light emitted when de-excitation occurs Emission spectra shifted to lower energies Absorption and emission spectra do not overlap  emitted light is not re-absorbed.

Properties of Plastic Scintillator Typical figures of merit: –Light yield (% compared with anthracene) –Emission spectrum –Bulk attenuation length –Rise time, decay times (short, long) Bicron-408: –  r = 0.9 ns,  f = 2.1 ns –Bulk attenuation length, = 380 cm

Examples from BicronBicron Blue

Photomultiplier Tubes Books from vendors are fun to read:Books

Typical construction: This kind won’t work in a magnetic field. Mesh dynode structure: This kind will work in a magnetic field. Photomultiplier Tubes

Window material: –Borosilicate glass: transmits blue (not UV) Photocathode: –Bialkali metal (Sb-Rb-Cs): low work function –Also important: low dark current Dynodes: –Metal with secondary emissive material Good (relatively inexpensive): Be-CuO-Cs Better (more expensive): GaP: Cs

Photomultiplier Tube Properties Quantum efficiency: 20% at 390 nm Gain: With n=19,  ~ 10 7 at 2 kV and no B field Gain greatly reduced in a magnetic field 2R ~2 kV

Mesh PMT’s in Magnetic Fields Gain is reduced by,but not to zero Large tube-to-tube variation 1.4 Tesla

Preamp for PMT We added a preamplifier with a gain of 15 Differential output driver Gain switches to ~2 for big pulses

Photomultiplier tube properties Timing characteristics: –Pulse shape: Gaussian, few ns risetime –Transit time: ~ 15 ns –Transit time spread: ~ 300 ps Timing resolution is roughly TTS / √n That’s why we want n to be large.

Photomultiplier tube properties Gain  Transit time Pulse rise time Pulse width

PMT-Scintillator interface Scintillator dimensions is about 2x2 cm Sensitive area of photocathode is 27 mm Optical couplings made using glue or silicone pads

The CDF-II TOF System Look for it here…

The CDF-II TOF System The PMT goes in here.

Front-end Electronics Requirements: –Measure arrival time of pulse from PMT –Measure pulse height (or charge) –Do it every 132 ns (whimsical requirement) –Precision should be < 25 ps Limitations: –Only measures time of first pulse –Light from multiple pulses overlap (biases Q)

Front-end Electronics Fast components go to discriminator. Slow components used to measure charge. High pass filter Low pass filter

Measuring Time Time measured using TAC with respect to a common stop signal: Voltage proportional to time difference between START and STOP

Interface with ADMEM Use ADMEM boards to read out TOF: –CAFÉ cards measure charge –deCAF cards measure time (output of TAC) 9 channels

Typical Response Response of PMT from cosmic rays: 132 ns

Pulse Properties Pulse shape is a complicated mixture of –Scintillation process –Light transport in the scintillator –Optics of PMT coupling –PMT response –Shaping from base –Preamplifier –Cables –Receiver and discriminator

Things we can’t measure directly Absolute gain: –Need calibrated light source (we do have a laser…) –Need magnetic field –Systematics from electronics (preamp,Q anode  ADC?) –Probably averages around 3 x 10 4 Number of photons: –Don’t know PMT properties well enough –Don’t know the gain precisely –Systematics from electronics –Probably end up with few 100 p.e. Most effects are parameterized by the empirical model used for calibration.

Simulated pulses We can’t probe the electronics on CDF to see what the pulses really look like. Simulations can provide a qualitative description of most effects. Muon Scintillator bar Near PMT Far PMT

Simulated pulses Compare pulse shapes at east/west ends: Attenuated far pulse

Timing Resolution Stated goal was “100 ps”. Actual model is: Resolutions measured after calibrations: Not the complete story, see next talk by Stephanie…

Summary Typical TOF detector –BC-408 scintillator –Mesh PMT’s –Properties poorly controlled – each channel is different Unique features –Hadron collider environment –Small bar cross section: not much light output DAQ interface –Looks like one of the calorimeters Performance –Generally meets timing precision requirements…