Declaration of Relevant Financial Interests or Relationships Speaker Name: J. Tokuda I have no relevant financial interest or relationship to disclose.

Slides:



Advertisements
Similar presentations
Diffusion-Weighted Imaging in Magnetic Resonance Imaging for prostate gland in Malaysian males with high prostate specific antigen in the diagnosis of.
Advertisements

Surgical Planning Laboratory Brigham and Women’s Hospital Boston, Massachusetts USA a teaching affiliate of Harvard Medical School User Interfaces and.
Clinical Evaluation of Fast T2-Corrected MR Spectroscopy Compared to Multi-Point 3D Dixon for Hepatic Lipid and Iron Quantification Puneet Sharma 1, Xiaodong.
3D Slicer in Image Guided Therapy Nobuhiko Hata, PhD Brigham and Women’s Hospital.
©2005 Surgical Planning Laboratory, ARR Slide 1 U41: Research resource for Image guided therapy PI: Ferenc Jolesz.
Mungunkhuyag Majigsuren1, Takashi Abe1, Masafumi Harada1
High-grade Prostatic Intraepithelial Neoplasia on Needle Biopsy Risk of Cancer on Repeat Biopsy Related to Number of Involved Cores and Morphologic Pattern.
Declaration of Conflict of Interest or Relationship Speaker Name: Yong-Lae Park I have no conflicts of interest to disclose with regard to the subject.
© NIH National Center for Image-Guided Therapy, March 2008 IGT Clinical Workshop Non-Rigid, Multi-Modality Image Registration for Thermal Ablation: Non-Rigid,
©2005 Surgical Planning Laboratory, ARR Slide 1 Magnetic Resonance Therapy: The Prostate program Clare Tempany MD Director, MRT Program leader & Core Leader.
NA-MIC National Alliance for Medical Image Computing Non-rigid MR-CT Image Registration Atsushi Yamada, Dominik S. Meier and Nobuhiko.
Slicer IGT and Open IGT Link
Tumor Localization Techniques Richard Kao April 10, 2001 Computer Integrated Surgery II.
MRI-compatible Voltage-based Electro-anatomic Mapping System for 3T MR-guided Cardiac Electrophysiology Shelley Zhang et al. (SCMR poster) Developing MRI-Compatible.
“ONE FAMILY’S STORY” John Emond, NASA Headquarters Human Interest Panel FLC Mid-Atlantic Region Annual Conference September 16, 2009.
The Value of Six Month Interval Imaging Following Benign Radiologic-Pathologic Concordant Minimally Invasive Breast Biopsy Manjoros DT, Collett AE, Alberty-Oller.
NA-MIC National Alliance for Medical Image Computing Slicer for Neurosurgical Planning IBMSPS th Annual World Congress for Brain.
Image-guided therapy and medical robotics tutorial using a LEGO Mindstorms NXT robot and 3D Slicer Danielle F. Pace, B.CmpH Ron Kikinis, M.D. Nobuhiko.
Introduction Many clinicians routinely use multiple receive coils for magnetic resonance imaging (MRI) studies of the human brain. In conjunction with.
3D Slicer: A Free & Open Source Platform For Medical Image Analysis and Visualization Brigham and Women’s Hospital.
NA-MIC National Alliance for Medical Image Computing Mechanically Assisted Trans- Rectal Prostate Biopsy DBP2: Prostate Interventions,
MRI-Ultrasound Fusion-Guided Biopsy of the Prostate: Results of Initial Experience in a Radiation Oncology Department Department of Radiation Oncology.
Correcting for Center Frequency Variations in MRSI Data Using the Partially Suppressed Water Signal Lawrence P Panych, Ph.D., Joseph R Roebuck, Ph.D.,
Comparison of Surface Coil and Automatically-tuned, Flexible Interventional Coil Imaging in a Porcine Knee R. Venook 1, B. Hargreaves 1, S. Conolly 1,
Online Guidance of Tumor Targeted Prostate Brachytherapy using Histologically Referenced MRI C. Ménard 1, J. Lee 1, A. Rink 1, J. Abed 1, D. Iupati 1,
Methods Validation with Simulated Data 1.Generate random linear objects in the model coordinate system. 2.Generate a random set of points on each linear.
Contact: Beyond Low Rank + Sparse: Multi-scale Low Rank Reconstruction for Dynamic Contrast Enhanced Imaging Frank Ong1, Tao Zhang2,
ASNR 2012 Methodology for Imaging Genomics of Gliomas
Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For.
NA-MIC National Alliance for Medical Image Computing Non-rigid MR-CT Image Registration Atsushi Yamada, Dominik S. Meier and Nobuhiko.
Advisor Client Justin Williams, PhD Department of BiomedicalEngineering University of Wisconsin-Madison Fredrick Kelcz, PhD, MD Department of Radiology.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
NA-MIC National Alliance for Medical Image Computing An Integrated System for Image-Guided Radiofrequency Ablation (RFA) of Liver Tumors.
“Prostate Cartography”: Targeted &systematic perineal stereotactic prostate biopsy using the BiopSee®platform in locating and re-locating prostate cancer.
Compressed Sensing 4D Flow Reconstruction using Divergence-free Wavelet Transform Frank Ong 1, Martin Uecker 1, Umar Tariq 2, Albert Hsiao 2, Marcus Alley.
©2005 Surgical Planning Laboratory, ARR Slide 1 Prostate Image Processing Steven Haker, PhD.
Continuous SWIFT Djaudat Idiyatullin. , Steven Suddarth+, Curt Corum
NA-MIC National Alliance for Medical Image Computing DBP2: Software Integration for Image Guided Surgery Gabor Fichtinger & Andras Lasso.
-1- National Alliance for Medical Image Computing MR-guided prostate interventions using the NA-MIC Kit Danielle Pace, B.CmpH and Sota Oguro, M.D. Surgical.
-1- National Alliance for Medical Image Computing MR-guided prostate interventions using the NA-MIC Kit Danielle Pace, B.CmpH and Sota Oguro, M.D. Surgical.
Characteristic Dynamic Enhancement Pattern of MR imaging for Malignant Thyroid Tumor XIX Symposium Neuroradiologicum Division of Head & Neck radiology.
Metabolic mapping of human gliomas Assessment with simultaneous MR/PET imaging for preoperative „hot-spot“ imaging of suspected anaplastic gliomas S. Bisdas.
© NIH National Center for Image-Guided Therapy, November, 2008 Prostate Robot Project Junichi Tokuda, Nobuhiko Hata, Clif Burdette, Jack Blevins, Clare.
Declaration of Conflict of Interest or Relationship Speaker Name: Santhi Elayaperumal I have no conflicts of interest to disclose with regard to the subject.
The responsibilities of a radiation therapist supporting MRI-guided High Dose Rate Brachytherapy for Prostate Cancer Jessy Abed 1, Amanda Bolderston 1,
Critical Review Computer Integrated Surgery II Adam Clayton Review paper: Robotic system for prostate brachytherapy Robotic system for prostate.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Prostate cancer update Suresh GANTA Consultant urological surgeon Manor Hospital.
© NIH National Center for Image-Guided Therapy, June 2008 Slicer IGT Nobuhiko Hata, PhD Sandy Wells, PhD Computation Core, NCIGT.
N. Kuo, H.J. Kang, T. DeJournett, J. Spicer, and E. Boctor Proc. SPIE 7964, (2011); doi: / Photoacoustic Imaging of Prostate Brachytherapy.
An Open Source Platform for Registration, Segmentation, Quantitative Analysis, and Visualization of Biomedical Image Data 3D Slicer About 3D Slicer Segmentation.
Prostate Segmentation Challenge and MR-guided Prostate Biopsy Haytham Elhawary, Nobuhiko Hata Brigham and Women’s Hospital and Harvard Medical School,
QIN Informatics and Software Tool Sharing 3D Slicer Andriy Fedorov, Brigham and Women’s Hospital
© 2016 Global Market Insights, Inc. USA. All Rights Reserved Fuel Cell Market size worth $25.5bn by 2024Low Power Wide Area Network.
RadVision integration with TRUS robot for Brachytherapy
Don Nguyen1, Sean Li1, Jinxing Yu, MD1
Quantification of tumor localization needle displacement prior to tumor excision in navigated lumpectomy Christina Yan1, Tamas Ungi1, Gabrielle Gauvin2,
Date of download: 10/23/2017 Copyright © ASME. All rights reserved.
Sunil Kripalani, MD, MSc;1 Christianne L
Ron Kikinis, MD Professor of Radiology, Harvard Medical School
Non-rigid MR-CT Image Registration
What would you recommend?
SPECIMEN SONOGRAM - Procedure
European Urology Oncology
Breast Magnetic Resonance Imaging for the Interventionalist: Magnetic Resonance Imaging–Guided Vacuum-Assisted Breast Biopsy  Sandra B. Brennan, MD  Techniques.
Interventional MRI–Guided Deep Brain Stimulation Lead Implantation
Volume 65, Issue 3, Pages (March 2014)
Igyne Tutorial Xiaojun Chen, Ph.D.1 Jan Egger, Ph.D., Ph.D.1
Non-rigid Registration of Pre-procedural MRI and Intra-procedural CT for CT-guided Cryoablation Therapy of Liver Cancer Atsushi Yamada, Dominik S. Meier.
What is 3D Slicer? Nobuhiko Hata, PhD.
Presentation transcript:

Declaration of Relevant Financial Interests or Relationships Speaker Name: J. Tokuda I have no relevant financial interest or relationship to disclose with regard to the subject matter of this presentation.

Preliminary Accuracy Evaluation of 3T MRI-guided Transperineal Prostate Biopsy with Grid Template J. Tokuda 1, K. Tuncali 1, I. Iordachita 2, S-E. Song 1, A. Fedorov 1, S. Oguro 1, A. Lasso 3, F. M. Fennessy 1, Y. Tang 1, C. M. Tempany 1, N. Hata 1 1 Department of Radiology, Brigham and Women’s Hospital, Boston, MA, USA 2 The Johns Hopkins University, Baltimore, MD, USA 3 School of Computing, Queen’s University, Kingston, ON, Canada Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Introduction

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 MRI-guided Prostate Biopsy Alternative to conventional Transrectal ultrasound (TRUS)-guided biopsy – Better delineation of prostate and substructures – For patients with rising PSA level and negative TRUS- guided biopsies Approaches – Transperineal biopsy in 0.5 T open MRI [1] – Transrectal biopsy in 1.5 – 3T closed- bore MRI with supporting devices [2, 3] [1] D’Amico AV et al., J Urol, 2000; 164(2): [2] Susil RC, et al. Magn Reson Med 2004;52(3): [3] Hambrock T, et al. Invest Radiol 2008;43(10):

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 MRI-guided Prostate Biopsy Transperineal Prostate Biopsy in 3 T MRI? – Superior image quality to 1.5 T MRI – Better approach for lesions in central gland – Suitable for patients who are unable to have: TRUS / MRI with endorectal coil transrectal guiding device Needs for supporting devices / software for transperineal prostate biopsy in 3T MRI – Wide-bore (70 cm) 3T MRI

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Objectives Development of device/software to support transperineal prostate biopsy guided by wide- bore 3T MRI – Prostate intervention table – Template calibration using fiducial frame – Navigation software Feasibility study: targeting accuracy evaluation – Preliminary evaluation in first 5 patients in ongoing clinical study

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Materials and Methods

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Prostate Intervention Table Supporting a patient in lithotomy position (A) Base board (B) Leg support (C) Stationary frame (D) Template (plexiglas) (E) “Z-frame” (A) (B) (C), (D) (E) (D) (B)

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Template Calibration Calibration by Z-shaped fiducial (Z-frame) – Automatic estimation of position and orientation of Z- frame from cross-sectional image – 3D FLASH (Matrix: 256x256x20, FOV: 16cm) Z-frame Template

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Navigation Software 3D Slicer [4] with ProstateNav Plug-in module [5] – Registration of pre- and intra-procedural images using B-Spline deformable registration – Target planning – Template calibration – Hole selection – Confirmation [4] [5] Tokuda J, et al. Comput Med Imaging Graph, 2010; 34(1):3-8

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Clinical Workflow Initial setup > Adjust leg holders Drape / cleaning Stationary frame Template and Z-frame > Adjust template position > Template registration Needle Insertion

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Clinical Workflow Initial setup > Adjust leg holders Drape / cleaning Stationary frame Template and Z-frame > Adjust template position > Template registration Needle Insertion

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Clinical Workflow Initial setup > Adjust leg holders Drape / cleaning Stationary frame Template and Z-frame > Adjust template position > Template registration Needle Insertion

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Clinical Workflow Initial setup > Adjust leg holders Drape / cleaning Stationary frame Template and Z-frame > Adjust template position > Template registration Needle Insertion

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Clinical Workflow Initial setup > Adjust leg holders Drape / cleaning Stationary frame Template and Z-frame > Adjust template position > Template registration Needle Insertion

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Clinical Study Core biopsy needle – 18G / diamond-shaped tip * Imaging – Tumor identification with preprocedural MRI ** (T2w, DWI, DCE-MRI) with endorectal coil *** – Planning with intraprocedural T2w MRI (2D TSE) **** – Confirmation image (2D FISP) **** *MRI Bio Gun, E-Z-EM, Westbury, NY **Signa HDx 15.0 (3T), GE Healthcare, Waukesha, WI ***MEDRAD eCoil, MEDRAD Inc., Warrendale, PA ****MAGNETOM Verio 3T VB17, Siemens AG, Erlangen, Germany

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Targeting Accuracy Evaluation First 5 patients (age: 57 – 73) 2D root mean square error (RMS) between: – Center of needle artifact on confirmation image – Planned target No consideration of error in depth direction Sampling 20 mm core along needle axis

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Results

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Real-time MRI of Needle Insertion * 5 times faster than actual speed

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Results in 5 Cases 2D targeting error: 4.9 mm All cases successfully completed – Mean number of target locations: 4 / case – Mean number of cores: 7 / case – Mean time of procedure: 107 ± 15 min. Case #12345 # of target locations23546 # of cores Targeting error (mm) Duration of procedure (min)

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Discussion and Conclusion

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Discussions and Conclusions Targeting error is less than the error in MRI- guided prostate biopsy in 0.5 T open MRI (6.5 mm) [6] Possible error sources: – Miscalibration of the template – Gap between holes on the template (5 mm) – Needle bending MRI-guided prostate biopsy in wide-bore 3T MRI using prostate intervention table and 3D Slicer was feasible [6] Blumenfeld P., et al. J Magn Reson Imaging 2007; 26(3):

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Related Presentations (Oral) 53: Tuncali K, et al. 3T MRI-guided ransperineal Targeted Prostate Biopsy: Clinical Feasibility, Safety, and Early Results. Session:Prostate Room 518 ‐ A ‐ C Date/Time:Monday, May 9, 12:48-13:00 (E-poster) 3055: Fedorov A, et al. Hierarchical Image Registration for Improved Sampling during 3T MRI-guided Transperineal Targeted Prostate Biopsy Date/Time:Thursday, May 12, 13:30-15:30 Presentation:14:30-15:00 (Poster) : Franco F, et al. Correaltion of Histology from MR-guided Transperineal Prostate biopsy with Multiparametric MR Imaging: A Feasibility Study. Session: Prostate Cancer (Clinical Studies) Date/Time: Tuesday, May 10, 13:30-15:30

ISMRM 2011 Tokuda et al : Accuracy of 3T MRI-guided Prostate Biopsy 3761 Acknowledgements This work is supported by R01CA111288, P41RR019703, P01CA067165, U01CA151261, and U54EB from NIH. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIH. Authors thank Angela Kanan, Nancy Trane, Colleen Huether, and other nurses and MR technicians for their help.