4. Advances in Gas Chromatography. Topics covered capillary columns headspace analysis solid phase micro-extraction.

Slides:



Advertisements
Similar presentations
Introduction to Chromatography
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
Gas Chromatography 427 PHC.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
GAS CHROMATOGRAPHY.
Lab Methods Day June 25, 2014 Gas Chromatography
Mobile phase is a gas! Stationary phase could be anything but a gas
Introduction to Chromatographic Separations Due to lack of analytical specificity, separations are often necessary Chromatography is about separations.
1 Gas Chromatography Lecture a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.
The geometry of capillary columns is fairly simple, consisting of length, internal diameter, and stationary phase thickness. Nevertheless, there are endless.
Chromatography.
In carbon-13 NMR, what do the number of peaks represent?
Chem. 133 – 5/5 Lecture. Announcements Lab Report 2.4 due Thursday – can turn in today for reduction of late penalties Term Project Progress Report –
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Capillary Columns Nicholas H. Snow Department of Chemistry, Seton Hall University, 400 South Orange Avenue, South Orange, NJ 07079
Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.
Intro to Chromatographic Separations Chap 26. Originally based on separation and identification by color Originally based on separation and identification.
Chromatography Chapter 4.
Gas Liquid Chromatography
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Effect of Packing Particle Size on Plate Height. Resolution between 2 adjacent peaks.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
Chapter 6 - Chromatography
Created with MindGenius Business 2005® Performance parameters (Advanced) Theoretical Plate Model Performance parameters (Advanced) Theoretical Plate Model.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Chapter 27 Gas Chromatography 1. Principles
High Performance Liquid Chromatography
Chromatography Chromatographic separation is based on distribution of separated compound (analyte) between mobile phase and stationary phase Richard Vytášek.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Basics of Chromatography Separation of Analytes Type of Equilibrium.
Chromatography Separates components in mixture: Based on - polarity
Chromatography Tomáš Mlčoch Pavel Moťka. Chromatography Described by Tswett in 1906 Described by Tswett in 1906 He separated some pigments using a tube.
Chromatography Chapter 6.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
LECTURE 9 CHROMATOGRAPHIC SEPARATIONS The “stuff” you do before you analyze a “complex” sample.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
PLOT Columns P orous L ayer O pen T ubular Porous layer open tubular (PLOT) columns are defined as capillary columns where the inner surface is coated.
animation.php.
High Performance Liquid Chromatography Instrumentation.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
INTRODUCTION TO CHROMATOGRAPY
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Introduction to Chromatography Definition Chromatography is a separation technique based on the different interactions of compounds with two phases, a.
Gas Chromatography Lecture 38.
Gas Chromatography Experiment. Gas Chromatography - Gas Chromatography (GC) is a common technique used to separate and identify volatile organic compounds.
Analytical Separations
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC). HIGH PERFORMANCE LIQUID CHROMATOGRAPHY High Performance Liquid Chromatography (HPLC) is one of the most.
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
The Chromatogram  Terms:  Retention time  Peak area  Peak width (at half height, at base)  Peak height  Void time/volume  Adjusted retention time.
HPLC.
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Introduction to Gas Chromatography
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Principles of chromatography
1 Principles of Chromatography Chap Analytical Separations and Chemical Problem Solving If you, a researcher of a food company are asked to find.
Experiments in Analytical Chemistry
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Laboratory class on next Wednesday
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
Chem. 133 – 5/9 Lecture.
Chromatography- TLC & HPLC
Chem. 133 – 5/11 Lecture.
Chromatography Daheeya Alenazi.
Principle of separation of different components:
GAS CHROMATOGRAPHY.
Presentation transcript:

4. Advances in Gas Chromatography

Topics covered capillary columns headspace analysis solid phase micro-extraction

Capillary columns - research Van Deemter derived an equation to explain chromatography in general H is the height of a theoretical plate is the mobile phase flow rate A, B and C are constants related to particular aspects of the movement of compounds through a specific column/mobile phase combination

Exercise 4.1 a)What is the meaning of the term “theoretical plate”? the smallest volume of st. phase where sep’n occurs b)How is H related to the term “N – the number of theoretical plates”? length ÷ N c)How do H and N relate to column performance? the smaller the value of H, the more N, the better

Van Deemter equation importance there is an optimum flow rate for maximising the separation the meaning of the A, B and C terms H Flow rate

Table 4.1 System propertyImprovement in H caused by A Consistency of flow of analyte molecules in gas stream More uniform and smaller packing B Travel of particles in a straight lineIncreased flow rate C Rate of transfer of solute between phases Large surface area but very thin films of stationary phase

Exercise 4.2 a)Describe the physical construction of a capillary column. long, narrow, hollow, s.p. bound to walls b)How do these physical characteristics match with the improvements suggested? A - no packing means as uniform as possible and molecular size B – hollow tube increases flow rates C - length and thin films allow rapid phase transfer

The first capillary columns first columns applied van Deemter conclusions to the max very narrow bore, with very thin stationary phase films sample capacity was too low to be practical the stationary phase was adsorbed onto the inner walls of the column major “bleed” problems (where the stationary phase isn’t stationary!) constructed from stainless steel, copper or glass not flexible, and could not be coiled readily without breaking, limiting the lengths available

Improvements physical size (internal diameter, length) sample capacity is related to internal diameter larger bore columns (up to 0.75 mm internal diameter) (known as megabore columns) longer columns also became available (up to 100 m)

Improvements stationary phase thickness limited sample capacity of early columns also related to their very thin and inconsistent films improved methods of manufacture allow a range of film thicknesses with great uniformity

Improvements method of binding the stationary phase to the column to prevent column bleed: bonded covalently bonded to the silica wall material less bleed during use can be used to higher temperatures rinsable porous layer (PLOT) or support coated (SCOT) a layer of porous material is bonded to the inner walls of the column the stationary phase adsorbs into this (like packed column particles)

Improvements column wall material fused silica is used in fibre optics much stronger than glass or metal can be made much thinner when coated in a heat-stable plastic, becomes very flexible (these are known as FSOT) columns)

Current status Wall materialFused silica Stationary phase bondingBonded phases Length10 – 100 m Internal diameter0.1 – 0.75 mm Film thickness 0.1 – 5  m

Benefits improved efficiency substantially over packed columns H is not much improved because of “improvements” in useability capillary columns are much longer N is much greater 100,000 vs 5,000 Exercise 4.3 Why can’t packed columns be made as long as capillary columns? gas can’t be forced through more than 3m of packing

Advantages improved efficiency greater column inertness (do not permanently adsorb certain species) greater reproducibility between runs fewer stationary phases needed more sensitive lower column bleed same sample capillary packed

Disadvantages higher initial cost cannot be repaired non-volatile species can block the column lower sample capacity

Column characteristics & performance look at a GC column catalogue and you are bombarded with choice for each different stationary phase, there are up to 50 options based on: internal diameter (i.d.) stationary phase film thickness length each affects performance capacity flow rate efficiency

Column characteristics & performance Internal Diameter Stat. Phase Thickness Column Length Sample Capacity Mobile Phase Flow Rate Column Efficiency

Exercise 4.4 Sample capacityFlow rateEfficiency Increase i.d.Increase Decrease Increase s.p. thickness IncreaseNo effectDecrease Increase lengthNo effectDecreaseIncrease

Column choice Stationary phase choose the least polar column that will do the job (columns indicated with the number 5, eg BP5, will separate about 90% of mixtures Internal diameter 0.25 mm i.d. columns have the best compromise between efficiency and capacity narrow bore columns may require special fittings

Column choice Film thickness thinner films – analytes with high boiling points thicker films better capacity, low b.p. compounds increase retention times and peak broadening Length 30 m – best balance of resolution, analysis time, and required column head pressure a 30 m column with a thicker film may be as useful as a 60 m column

Injection splitting even megabore columns have smaller capacity than packed columns less than 1 uL of concentrated sample less than this not precise (even with an internal standard) use of a split injection system two pathways after injection port – one to waste, one to column tap regulates proportion columnseptum mobile phase heated chamber split ratio control

Headspace analysis for samples with highly volatile components, eg fragrances where the vapour is of more interest sample temperature-equilibrated to obtain a reproducible vapour larger injection volumes (100 uL) used because of low concs in gases injection port doesn’t need to be heated

Solid phase micro-extraction alternative to solvent extraction pen-like cartridge with extendable coated fibre which adsorbs volatiles (by polarity attraction) becomes the “syringe” various factors influence efficiency