40/100 Gb/s Ethernet Over Multi-mode Optical Fiber Planning for Infrastructure Readiness.

Slides:



Advertisements
Similar presentations
Unit-2 Polarization and Dispersion
Advertisements

Waveguides Seminary 5. Problem 5.1 Attenuation and crosstalk of a wire pair A carrier frequency connection is transmitted on twisted pairs with the following.
Structured Network Cabling CIS 399 Day 1, Morning Session 2 Dale Smith University of Oregon & NSRC
Optical Interfaces Lab Last Update Copyright 2014 Kenneth M. Chipps Ph.D. 1.
10 Gigabit Ethernet Market and Technology Overview David O’Leary Director, Consulting Engineering.
CCNA 1: Module 7 Ethernet Technologies. Overview The most successful LAN technology –Easy to install –Has evolved to meet changing needs Media Increased.
Fiber-Optic Communications
Network+ Guide to Networks, Fourth Edition Chapter 3 Transmission Basics and Networking Media.
1 6/19/ :50 CS57510 Gigabit Ethernet1 Rivier College CS575: Advanced LANs 10 Gigabit Ethernet.
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
NESCOT CATC1 Ethernet Technologies CCNA 1 v3 – Module 7.
Connectivity Unlimited TM Wireless Optical Transmission at 10 Gbps and Beyond.
Module 7 Chapter 6 Ethernet Technologies. 10-Mbps Ethernet Legacy Ethernet –10BASE5, 10BASE2, and 10BASE-T Four common features of Legacy Ethernet –Timing.
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
Fiber-Optic Communications
1 Nexans Cabling Solutions Fibre solutions for fast deployment Joost Grillaert.
Copyright CCNA 1 Chapter 6, Part 1 Ethernet Technologies By Your Name.
Transmission Media Used in Campus Networks
Other Ethernet technologies Light Source. Other Ethernet Physical Layer Standards  100Base-X 100 Mbps 100Base-TX uses Cat 5 UTP to desktop  1000Base-X.
Chapter 8 Basic System Design.
1 Fiber Optics MULTIMODE VS. SINGLEMODE FIBER. 2 Fiber Optics When we talk about fiber we refer to either multimode or singlemode fiber. We further clarify.
March, 2013 Presenting: Avner Badihi TECHNOLOGY&MANUFACTURING XLoom Proprietary and Confidential 120GB-300Gb Optical Interconnect Solutions for Optical.
Poznan Supercomputing and Networking Center
NETWORK+ GUIDE TO NETWORKS 6 TH EDITION CHAPTER 5 TOPOLOGIES AND ETHERNET STANDARDS.
1 Nexans Cabling Solutions Easy and reliable migration from fast to faster to100G.
Optical Fiber Basics-Part 2
Semester 1 Module 7 Ethernet Technologies
Light Wave Systems Dr Manoj Kumar Professor & Head Department of ECE DAVIET,Jalandhar.
Standards Report FOLS Meeting – February Overview TIA TR-42 update LAN application update.
1 CISCO NETWORKING ACADEMY PROGRAM (CNAP) SEMESTER 1/ MODULE 4 Cable Testing.
The Future of Structured Cabling
Dense Wavelength Division Multiplexing (DWDM) Technology
© N. Ganesan, Ph.D., All rights reserved. Chapter Electronic and Optical Transmission.
OC-192 VSR Interfaces Russ Tuck, Ph.D.
National Institute of Science & Technology 1 TECHNICAL SEMINAR REPORT 10 GIGABIT ETHERNET TECHNOLOGY.
Campus Network Structured Cabling. We all have some ugly wiring.
Gigabit Ethernet.
Five components of data communication
Ethernet- The Next Generation John D’Ambrosia - Chair, IEEE HSSG Scientist, Components Technology.
Chapter 8 Basic System Design. System factors for designing from scratch: Design Verification FactorAvailable choices Type of fiberSingle mode, multimode,
Work at OIF on Interfaces for Optical Modules including Very Short Reach (VSR) and Electrical Interfaces Raj Savara Network Elements Inc.
Chapter 8 Basic System Design.
Defining 10GBASE-S over OM4media (Engineered Link) Steve Swanson, Corning Adrian Amezcua, Draka.
Sem1 - Module 7 Ethernet Technologies All versions of Ethernet have the same: 1.MAC addressing 2.CSMA/CD 3.Frame format However, other aspects.
1 Recommendations Now that 40 GbE has been adopted as part of the 802.3ba Task Force, there is a need to consider inter-switch links applications at 40.
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
40 and 100 GbE – Network Interfaces of the Future
Ethernet Advanced Chapter 5. Release 16/7/2009 Chapter Objectives Explain 10Base-T network Explain 10Base-FL Explain the rule Identify different.
Outside Plant Fiber Optics
Semester 1 v CCNA 1 Module 7: Ethernet Technologies.
1 Rick Dallmann Session: DB 1.1 Designing Next-Generation SAN/Storage Optical Infrastructure Why Low Link (Budget) Loss is Critical.
Application Note Fiber Connectivity Riedel solutions for broadcast applications 1 Application Note - Fiber Connectivity.
100 Gig E - What's New and What's Next ?
3 Fiber-Optic Cable Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Objectives  Explain how fiber-optic cable.
© 2003, Cisco Systems, Inc. All rights reserved.
Optimizing the Data Centre Physical Layer in the Era of the Cloud
10 GIGABIT ETHERNET TECHNOLOGY
Abbreviated designation
Ethernet- The Next Generation
Basic Knowledge and Technical Specifications of Cisco SFP Modules
10 Gigabit Ethernet 1 1.
Chapter 7 Basic System Design.
Design of Optical Digital Transmission Systems
Chapter 4: Network Access
Chapter 7 Basic System Design.
Click to edit Master subtitle style
Ethernet LAN 1 1.
Business Data Communications, 4e
Design of Optical Digital Transmission Systems
What are the advantages of OM5 fiber patch cord? “OM” is abbreviated for optical multimode, and it is specified by the ISO/IEC international standard.
Presentation transcript:

40/100 Gb/s Ethernet Over Multi-mode Optical Fiber Planning for Infrastructure Readiness

40/100 Gb/s over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations What’s the Bill Summary

3 40/100 Gb/s over MMF Evolution of Ethernet –40/100 Gb/s Ethernet Adoption Timeline –Server port growth –IEEE 802.3ba Objectives –OM3 –Link and Cable Characteristics Achieving 40/100 Gb Ethernet Issues Cabling Recommendations What’s the Bill Summary

Ethernet Timeline IEEE Ethernet IEEE 802.3a 10BASE2 IEEE 802.3a 10BASE-T IEEE 802.3j 10BASE-F IEEE 802.3u 100BASE-T IEEE 802.3z 1000BASE- CX,SX,LX IEEE 802.3ae 10GBASE- SR,LR,ER,SW,LW,EW,LX Time to Reach (years) Million Port Sale (after Ratification)60% Market Penetration 10 Mb E1 100 Mb E Mb E29 10 Gb E610+ Flatman, LAN Technologies, 2007

5 40/100 Gb Ethernet Source: Intel/Broadcom (Nov 2007)

6 IEEE 802.3ba Objectives Provide Physical Layer specifications which support 40 Gb/s operation over: –At least 100m on OM3 MMF –At least 10m over a copper cable assembly –At least 1m over a backplane Support a MAC date rate of 100 Gb/s Provide Physical Layer specifications which support 100 Gb/s operation over: –At least 40km on SMF –At least 10km on SMF –At least 100m on OM3 MMF –At least 10m over a copper cable assembly

7... at least 100m on OM3 MMF OM3* multi-mode fiber is: –50/125 µm –2000 MHzkm EMB**, minimum, at 850 nm ANSI/TIA-598-C Optical Fiber Cable Color Code –Indoor cable with AQUA jacket * Type A1a.2 as specified in IEC ** Effective Modal Bandwidth

8 Link and Cable Characteristics* Supported fiber types –50/125 µm, OM3 Effective Modal Bandwidth (EMB) –2000 MHzkm** minimum Power Budget –Greater than 8.3 dB*** Channel Insertion Loss –1.9 dB ◊ *As of December 2008 **Launch Condition Dependent ***For Further Study ◊ Connector Loss Under Study

9 40/100 GbE over MMF Evolution of Ethernet Achieving 40/100 Gb/s Ethernet –Enabling Technology –Parallel Optics, 40 Gb/s –Parallel Optics, 100 Gb/s –Polarity –Recap Issues Cabling Recommendations What’s the Bill Summary

10 Enabling Technology Multilane Distribution (MLD) – Parallel Links –40 Gb/s equals 4x fibers each for Tx and Rx Each carrying a 10 Gb/s signal –100 Gb/s equals 10x fibers each for Tx and Rx Each carrying a 10 Gb/s signal Today, two fibers can support full duplex 10 Gb/s 40 Gb/s will require 4x the fiber count

11 Parallel Optics, 40 Gb/s MTP™*/MPO (Multi-fiber Push On) Connectors 8 or 12 Fiber Loose Tube or Ribbon cable Likely a pre-terminated assembly solution *MTP is a registered trademark of USCONEC 40GBASE-SR4 Lanes Lanes

12 Proposed MDI Interface For 40GBASE-SR4 –This is what the connector on your switch/router will likely look like –Pins (male) will be on this receptacle –MPO – MPO preterm assemblies will be pinless (female) Paul Kolesar (Commscope), Sharon Lutz (USCONEC), Clause 86 MDI Optical Pin Layout and Connector, IEEE P802.3ba, Jan2009

13 Array Assemblies – Polarity Today Position 1 (Fiber 1) Key Up Position 12 (Fiber 12) Position 12 (Fiber 1) Position 1 (Fiber 12) Position 1 (Fiber 1) Position 12 (Fiber 12) Key UpKey Down Position 1 (Fiber 2) Position 12 (Fiber 11) Key UpKey Down Position 1 (Fiber 1) Position 12 (Fiber 12) Position 1 (Fiber 1) Position 12 (Fiber 12) Type-A MPO-to-MPO array cable Type-B MPO-to-MPO array cable Type-C MPO-to-MPO array cable TIA-568-C.3 Key UpKey Down

14 Parallel Optics, 100 Gb/s 100 Gb/s will use 10 fibers per Tx to Rx link Two 12F MTP/MPO connectors, or 24-Fiber MTP/MPO connections can significantly reduce pre-terminated connection costs and increase connection densities Lane assignments accepted at IEEE P802.3ba Draft 1.1

15 Proposed MDI Interface For 100GBASE-SR10 –Proposed options on switch/router connector –Pins (male) will be on these receptacles –MPO – MPO preterm assemblies will be pinless (female) Paul Kolesar (Commscope), Sharon Lutz (USCONEC), Clause 86 MDI Optical Pin Layout and Connector, IEEE P802.3ba, Jan2009

16 Recap 40/100 Gb/s will use –Multiple fibers per Tx/Rx link –Minimum of OM3 specified, nm –MTP/MPO connectors –Loose tube or ribbon cabling compatible with MTP/MPO –Preterm likely the norm –Polarity puzzle

17 40/100 GbE over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues –Arrival Time –Optical Skew –Skew Measurement –Skew Results Cabling Recommendations What’s the Bill Summary

18 Arrival Time Multi-lane signals launch simultaneously Fiber length and modal paths vary Signal components arrive out of sync This difference in arrival time is optical skew

19 Is Optical Skew a Problem? Transmission media (optical fiber) major contributor to skew –Proposed allowance* for skew due to transmission media 79 ns –Expected maximum contribution from optical media 13.6 ns Is a particular cable construction better in minimizing transmission optical skew? * 100GE/40GE skew budget, IEEE 802.3ba TF, Dallas November 2008, Gustlin/Anslow/Giannakopoulos

20 Optical Skew Measurement Method A –Transmit a pulse down the fiber –Measure arrival time –Repeat for all fibers –Calculate maximum difference Method B –Transmit a pulse down the fiber –Measure arrival time of reflections –Repeat for all fibers –Calculate maximum difference

21 Optical Skew Measurement Method C –Launch RF modulated optical signal down each fiber using single mode optics –Measure the phase difference of received RF signal with the reference, using a precise phase meter: propagation delay –Calculate maximum delay difference

22 Skew Measurement Results Quadrature Phase Shift Testing –100 meter test length Loose Tube tested maximum –0.8 ns Ribbon tested maximum –0.3 ns Proposed Skew Allowance for 40GBASE-SR4 and 100GBASE-SR10 –100 meter length 79 ns (about 100 times measured maximums) For Optical Skew neither loose tube cabling or ribbon cabling is a problem

23 40/100 GbE over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations –Size and Bend –Fiber Count What’s the Bill Summary

24 Size and Bend Optical Skew –Loose Tube and Ribbon cabling Optical skew adequately handled by electronics Preferential Bending Limits Flexibility –Loose Tube Cabling No preferential bend –Ribbon Cabling Has preferential bend Reduced O.D. 48F Loose Tube Cable (0.231”) 48F Stacked Ribbon Cable (0.520”) 48F Loose Tube Cable (0.370”)

25 Fiber Count Requirements (1) Today, a 12F, OM3, MPO-MPO backbone link –Provides up to six full duplex 10Gb/s Tx/Rx pairs 40GBASE-SR4 –Requires a minimum of eight OM3 fibers for a Tx/Rx link 4 fibers Tx 4 fibers Rx –Should be able use installed legacy 10GBASE-SR links 100m length 100GBASE-SR10 –Requires a minimum of 20 OM3 fibers for a Tx/Rx link 10 fibers Tx 10 fibers Rx

26 Fiber Count Requirements (2) Legacy 10 GbE systems may not be directly mappable to 40/100 Gb/s –A legacy 144F MPO-MPO backbone Will support 72x 10GBASE-SR duplex links Will support 12x 40GBASE-SR4 duplex links May support 6x 100GBASE-SR10 duplex links Bottom Line –Installing 10Gb Ethernet installations today will fully utilize available fibers –Future adoption of 40/100 Gb Ethernet will be able to use legacy cabling –Fiber utilization using legacy cabling will likely not be at 100%

27 40/100 GbE over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations What’s the Bill –Link Cost on OM3 –About single mode –OM3 and OS2 –About OM4 Summary

28 Link Cost on OM3 Traditional rule of thumb, 3x cost increase for 10x performance increase –Not likely to hold for 40/100 Gb/s –Estimates very preliminary, around 4x for 40GBASE-SR4 10GBASE-SR, XFP –About $1300, 2008 –4x equals $ x ports equals $10,400 12F, OM3, Loose Tube Plenum, 100m length –About $500 Total Link Cost $10,900, estimated

29 About Single Mode Not Parallel Optics Initial release using CWDM –40GBASE-LR4 uses 4x 10 Gb/s wavelengths –100GBASE-LR4 will likely use 4x 25 Gb/s wavelengths Estimate of 6x* cost of 10GBASE-LR –Expected cost reductions with technology/optimization improvements 10GBASE-LR, XFP $1600 –6x = $9600, Times 2 ports = $19,200 12F, OS2, Loose Tube Plenum, 100 m length –$200 * 40GbE Market: Timing and Opportunity, Alessandro Barbieri, September 2008 IEEE Seoul

30 OM3 and OS2 Estimated link cost for 40GBASE-SR4 –$10,900 Estimated link cost for 40GBASE-LR4 –$19,400 Cost difference OM3 OS2 – + $8,500

31 About OM4* Current 10GBASE-SR uses VCSEL’s –RMS Spectral width about 0.25 nm –That is a tight light source –When you combine low modal dispersion of OM4/OM3 fiber with low chromatic dispersion of this laser – you go farther Initial 40/100 Gb/s specification calls for –RMS Spectral width of 0.65 nm Why? –Reduce costs of transmitters and receivers –Early adopters of 40/100 Gb/s will be data centers/SAN’s * Not yet a standard

32 40/100 GbE over MMF Evolution of Ethernet Achieving 40/100 Gb Ethernet Issues Cabling Recommendations What’s the Bill Summary –40/100 Gb/s Redux

33 40/100 Gb/s Redux OM3 multi-mode fiber specified –2000 MHzkm EMB at 850 nm At least 100 meter runs supported Parallel optics used –MTP/MPO Optical skew exists but is compensated for by active components –Observed skew 100 times less than specified Optical cabling recommendations –Loose tube, no bending preference Cost

34 Alfred Flores Berk-Tek, a Nexans Company