Energy Efficient Fluid Flow. Fluid Flow System Fundamentals W motor = W fluid / (Eff motor x Eff drive x Eff pump )

Slides:



Advertisements
Similar presentations
Energy-Efficient Process Cooling
Advertisements

Energy Saving Options Electricity.
Fluid Mechanics.
SAMPLE SLIDES OF THE 1-DAY SEMINAR FOR PUMP USERS
Integrated Systems + Principles Approach. Source: California Energy Commission (2000) Manufacturing Energy End-Use Breakdown.
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
Variable Frequency Drives Energy Savings Applications & Benefits National Grid-NYSERDA Upstate NY Commercial Industrial Efficiency Expo March 30, 2010.
Variable Frequency Drives VFD Basics
Fluid Mechanics 07.
Optimizing Pump Systems for Energy Efficiency Gunnar Hovstadius,Ph.D., Director of Technology Don Casada, SR. Development Associate, Oak Ridge NL Goulds.
Energy Efficient Fluid Flow
Our Plan – Weeks 6 and 7 Review energy relationships in single pipes Extend analysis to progressively more complex systems – Pipes in parallel or series.
Presentation on Pumps ByG.MURALIKRISHNA EE(E) BSNL ED-1.
Pump Operational Flexibility & Optimization Pat Carney Flow-Technics Inc. Flow-Technics Inc1.
Integrated Systems + Principles Approach. Source: California Energy Commission (2000) Manufacturing Energy End-Use Breakdown.
CE 230-Engineering Fluid Mechanics
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Prelim 1 Review.
Pump Basics. Centrifugal Pumps From the Center of a Circle RADIAL DIRECTION To the Outside of a Circle A machine for moving fluid by accelerating the.
Energy Efficient Motor Drive Systems. Motor Electricity Use Motors consume about 75% of all the electricity used by industry. Their popularity is a testament.
Jim Chmielewski – HVAC Sales Manager Emerson Control Techniques
1 CTC 450 Pumps Pumps
Water piping design.
POWER SAVING BY ROCKSOLID INDUSTRIAL SOLUTIONS SYSTEMS REQUIRING PUMPS USING VALVE CONTROL SYSTEMS REQUIRING FANS USING DAMPER CONTROL SAVE GOOD $MONEY$
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
Hawke’s Bay Refrigeration
TEAM UP! FOR FAN AND PUMP SAVINGS It can be as easy as replacing an old drive belt.
1 Pumping Learning Outcomes Upon completion of this training one should be able to: Know what are the key pump components and how they impact pump.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
TEC 4607 Wind and Hydro Power Technologies Fall 2011.
automation 4 me TYPES OF LOAD 1 automation 4 me CONSTANT TORQUE LOAD : PERCENT SPEED NOTE:- A CONSTANT TORQUE LOAD IS NOT NECESSARILY 100% LOAD TORQUE.
TEC 4607 Wind and Hydro Power Technologies Fall 2011.
Data centre air management Case studies Sophia Flucker.
Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.
SAMPLE SLIDES OF THE 2-DAY SEMINAR FOR ENGINEERS As you will notice there are few words on these slides, your trainer will provide you with his experience.
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
General Energy Equation. Chapter Objectives Identify the conditions under which energy losses occur in fluid flow systems. Identify the means by which.
Sizing Variable Flow Piping – An Opportunity for Reducing Energy
PIPE LINE SYSTEM Series Pipe Line System Class I Class II Class III
1 CEE 426 Wastewater Treatment Plant Design November 12, 2012 Thomas E. Jenkins President JenTech Inc N. Elm Tree Road Milwaukee, WI
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
Introduction to Energy Management
1 Hospital Building and Campus Piping. 2 Hospital Building Occupancy – office and patient areas Patient areas: 24 hours per day Office areas: 8 am – 5.
Lecture Objectives: Answer question related to Project 1 Finish with thermal storage systems Learn about plumbing systems.
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
Lecture Objectives: Plumbing Pumps Hydronic distribution systems
HVAC – Air Handling Unit Heating Ventilating AC =Cooling HVAC – Basic Terms hQ = 200,000 Btu/h CO2 20 cfm/ pers 50 people 1000 cfm cQ assume to = 20 tr.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 10 : CONTROL VALVES IN CLOSED LOOP SYSTEMS.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Course Exam Next Thursday (April 15) 7 pm Same classroom (ECJ 7.208) 2.5-hour exam Open book open notes All problem types of questions (short but comprehensive)
SUDHIR REDDY S.V.R M.TECH(CAD/CAM)
Chapter 10: Flows, Pumps, and Piping Design
Copyright 2011, Toshiba Corporation. Toshiba International Corp - Houston Tx Jim Hartzel Section Mgr - Water / Waste Water Business 20 Yrs Field Service.
Power – Energy Relationships
CENTIFUGAL PUMP OPERATION
Sustainability Best Practices
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Information the Might be Useful for the Exam
Energy Conservation Week- 2004
Variable Frequency Drive Savings Calculator Tools
Parul Institute of Technology
Energy Efficiency in District Coiling System
Volume Control in fluid distribution systems
ME444 ENGINEERING PIPING SYSTEM DESIGN
Pumps and Lift Stations
Review for the Exam Should be able to do all calculations associated with lectures as well as HWs Problems may deal with context i.e. Explain how thermal.
System One Pumps Selecting Centrifugal Pumps S1-201
Lecture Objectives: Learn about plumbing system and pumps
Lecture Objectives: Learn about plumbing system and pumps
50 m EML3015C Thermal-Fluid I Fall 2000 Homework 4
Presentation transcript:

Energy Efficient Fluid Flow

Fluid Flow System Fundamentals W motor = W fluid / (Eff motor x Eff drive x Eff pump )

Look For “Inside” Opportunities to Max Savings Efficiency losses in distribution and primary energy conversion systems multiply “inside” savings Example: –W elec = W fluid / [Eff pump x Eff drive x Eff motor ] –W elec = 1 kWh / [.70 x.92 x.90 ] = 1.7 kWh

Fluid Flow System Fundamentals W fluid = V  P total

Fluid Flow System Fundamentals W fluid = V  P total = V (k V 2) = k V 3 W friction = V  P friction = k / D 5

Pumping System Savings Opportunities Reduce volume flow rate Reduce required pump head  P static  P velocity  P elevation  P headloss Increase pump, drive, motor efficiency W elec = V  P total / [Eff pump x Eff drive x Eff motor ]

Fluid Flow System Saving Opportunities Reduce Required Pump/Fan  P Employ Energy Efficient Flow Control Improve Efficiency of Pumps/Fans

Reduce Pump/Fan  P

Increase Reservoir Level to Reduce Elevation Head

Minimize Pipe Friction: Use Bigger Pipes/Ducts  Use large diameter pipes:   P headloss ~ k / D 5  Doubling pipe diameter reduces friction by 97%

Minimize Pipe Friction Use Smooth Pipes/Ducts  Use smooth plastic pipes:  f steel = f plastic =  Pumping savings from plastic pipe (0.021 – 0.018) / = 17%

Use Gradual Elbows

Employ Energy Efficient Flow Control

Inefficient Flow Control By-pass loop (No savings) By-pass damper (No savings) Outlet valve/damper (Small savings) Inlet vanes (Moderate savings)

Efficient Flow Control Trim impellor for constant-volume pumps Slow fan for constant-volume fans VFD for variable-volume pumps or fans

Inefficient and Efficient Flow Control

Cooling Towers

Cooling Loop Pumps

Worlds Largest Bypass Pipe

For Constant Speed Pump Applications: Trim Pump Impellor Look for discharge valve at < 100% open More energy-efficient to downsize the pump by trimming impellor blades than throttle flow

Trim Impellor and Open Throttling Valve

For Constant Speed Fan Applications: Slow Fan Speed by Changing Pulley Diameter Look for discharge damper at < 100% open More energy-efficient to slow fan than throttle flow

For Variable Flow Applications: Install VFD W 2 = W 1 (V 2 /V 1 ) 3 Reducing flow by 50% reduces pumping costs by 87%

Variable Speed Pumping on HVAC Chilled Water Loops Replace 3-way Valve with 2-way valve on AHU

VFDs on Vent Hoods

Need Controls for VFDs on Dust Collection

Use VFDs on Cooling Tower Fans

Pump Long, Pump Slow Identify intermittent pumping applications More energy to pump at high flow rate for short period than low flow rate longer Example: –Current: Two pumps in parallel for four hours –Recommended: One pump for six hours –Estimated Savings: $500 /yr Reason: W fluid = V DP = k V 3

Optimize Efficiency of Pumps/Fans

Correct Fan Inlet/Exit Conditions No Yes

Refurbish Inefficient Pumps Pump not operated at peak efficiency in middle of operating range

Resize Miss-sized Pumps Pump operating at off- design point M Eff = 47% Replace with properly sized pump Estimated savings: $14,000 /yr

Fluid Flow Summary Reduce Required Pump/Fan Head –Reduce excess elevation head –Smoother pipes/ducts –Larger diameters –Gradual elbows Employ Energy Efficient Flow Control –Constant speed pumping: trim impellor blade –Constant speed fans: Slow fan –Variable flow: Install VFDs –Pump slow, pump long Improve Efficiency Pumps/Fans –Correct fan inlet/exit conditions –Refurbish inefficient pumps –Resize miss-sized pumps/fans