SCATS 6.9.1 Release Review SMUG, March 2013 Sydney.

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

CIMCO Integration Software Products
School Census Summer 2011 Headlines Version Jim Haywood Product Manager for Statutory Returns.
Mobile Manager v (including v1.1.1 and v1.2.2) Release Notes.
Protocol Configuration in Horner OCS
MXIE overview 5/4/ Update1. MXIE Media Exchange Interface for End Users 5/4/ Update2.
CCNA2 MODULE 5.
1 Configuring Internet- related services (April 22, 2015) © Abdou Illia, Spring 2015.
MCTS Guide to Microsoft Windows Server 2008 Network Infrastructure Configuration Chapter 4 Installing and Configuring the Dynamic Host Configuration Protocol.
Software to Manage EEP Vegetation Plot Data A design proposal Michael Lee January 31, 2011.
Guide to Oracle10G1 Introduction To Forms Builder Chapter 5.
70-293: MCSE Guide to Planning a Microsoft Windows Server 2003 Network, Enhanced Chapter 5: Planning, Configuring, And Troubleshooting DHCP.
1 Configuring Web services (Week 15, Monday 4/17/2006) © Abdou Illia, Spring 2006.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 5: Managing File Access.
A Guide to Oracle9i1 Introduction To Forms Builder Chapter 5.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 5: Managing File Access.
11.1 © 2004 Pearson Education, Inc. Exam Planning, Implementing, and Maintaining a Microsoft Windows Server 2003 Active Directory Infrastructure.
Hands-On Microsoft Windows Server 2003 Networking Chapter 7 Windows Internet Naming Service.
1 of 6 This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS DOCUMENT. © 2007 Microsoft Corporation.
Hands-On Microsoft Windows Server 2003 Administration Chapter 5 Administering File Resources.
MCDST : Supporting Users and Troubleshooting a Microsoft Windows XP Operating System Chapter 5: User Environment and Multiple Languages.
CCNA 2 v3.1 Module 2.
SETUP AND CONFIGURATIONS WEBLOGIC SERVER. 1.Weblogic Installation 2.Creating domain through configuration wizard 3.Creating domain using existing template.
Maintaining and Updating Windows Server 2008
Check Disk. Disk Defragmenter Using Disk Defragmenter Effectively Run Disk Defragmenter when the computer will receive the least usage. Educate users.
Copyright © 2013 FingerTec Worldwide Sdn.Bhd. All rights reserved.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
Ch 11 Managing System Reliability and Availability 1.
Configuring the MagicInfo Pro Display
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 5: Managing File Access.
Chapter 18: Windows Server 2008 R2 and Active Directory Backup and Maintenance BAI617.
Section 10: Assigning and Publishing Software Packages Using MSI Packages to Distribute Software Using Group Policy as a Software Deployment Method Deploying.
SEIMS SUPPORT N.C. State Board of Elections
Chapter 16 Designing Effective Output. E – 2 Before H000 Produce Hardware Investment Report HI000 Produce Hardware Investment Lines H100 Read Hardware.
1 CMPT 275 Phase: Design. Janice Regan, Map of design phase DESIGN HIGH LEVEL DESIGN Modularization User Interface Module Interfaces Data Persistance.
Chapter Two Defining Network Objects. Chapter Objectives Describe how a workstation communicates with the network, and list the software components required.
Specview 32 Release 2.5 Enhancements
Duty Log and Chat Setup SSG Frese, Jerome S. Sensor Manager Cell 12 MDD.
Tools Menu and Other Concepts Alerts Event Log SLA Management Search Address Space Search Syslog Download NetIIS Standalone Application.
MCTS Guide to Microsoft Windows Server 2008 Network Infrastructure Configuration Chapter 4 Installing and Configuring the Dynamic Host Configuration Protocol.
Diagnostic Pathfinder for Instructors. Diagnostic Pathfinder Local File vs. Database Normal operations Expert operations Admin operations.
FIX Eye FIX Eye Getting started: The guide EPAM Systems B2BITS.
0 eCPIC Admin Training: OMB Submission Packages and Annual Submissions These training materials are owned by the Federal Government. They can be used or.
Company Confidential OVERVIEW. Application and activity control software for networked computer classrooms …. designed to be used by teachers in order.
SCATS Release Review SMUG, March 2013 Sydney.
SCATS 6.10 Release Review SMUG, March 2013 Sydney.
NetTech Solutions Troubleshooting Office Applications Lesson Seven.
Office of Housing Choice Voucher Program Voucher Management System – VMS Version Released October 2011.
1 eCoRepair New Release Slide Expanded view of Circuit Details Change to Circuit Looping text4 View of closed faults up to 30 days old5 - 7 Minor.
Linux Operations and Administration
WESS Safety Authority WESS Module SA-2 SA Functions Modify Existing User Accounts.
+ Routing Concepts 1 st semester Objectives  Describe the primary functions and features of a router.  Explain how routers use information.
SCATS Commercial Releases SNUG, October 2015 Wellington, NZ.
5 Copyright © 2008, Oracle. All rights reserved. Testing and Validating a Repository.
ITMT 1371 – Window 7 Configuration 1 ITMT Windows 7 Configuration Chapter 8 – Managing and Monitoring Windows 7 Performance.
CACI Proprietary Information | Date 1 PD² SR13 Client Upgrade Name: Semarria Rosemond Title: Systems Analyst, Lead Date: December 8, 2011.
Proctor Caching and System Check September 4, 2014 Becky Hoeft Conference Number: (877) Conference Pin:
Maintaining and Updating Windows Server 2008 Lesson 8.
CACI Proprietary Information | Date 1 PD² v4.2 Increment 2 SR13 and FPDS Engine v3.5 Database Upgrade Name: Semarria Rosemond Title: Systems Analyst, Lead.
Monitoring Dynamic IOC Installations Using the alive Record Dohn Arms Beamline Controls & Data Acquisition Group Advanced Photon Source.
Xxx Presentation, No 1 Copyright © TAC AB Engineering Classic Networks1.
Purchase Orders May 2015 Supply Chain Platform: Rolls-Royce Training for Controls and Data Services Limited.
Emdeon Office Batch Management Services This document provides detailed information on Batch Import Services and other Batch features.
Chapter 2: System Structures
CONFIGURING HARDWARE DEVICE & START UP PROCESS
Configuring Internet-related services
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Creating and Managing Folders
Presentation transcript:

SCATS Release Review SMUG, March 2013 Sydney

2 SMUG 2013 SCATS Release Review This presentation describes the new features introduced in SCATS Commercial Release.

3 SMUG 2013 SCATS Release Scope 22 new features 19 enhancements 24 major issues resolved In operation at TMC since January 2012 – V Commercial release prepared in November 2012 – V SCATS Release Summary

4 SMUG 2013 SCATS 6.9.1: What’s new The major changes in this version are: Support for Windows® 7 and Windows® Server 2008 R2. Support for virtual environments and network dongles to allow for automatic failover or disaster recovery plans. An increase in the number of MSS, RSF and XSF flags from 16 to 32. The ability to lock and trim all flags, except MSS flags.

5 SMUG 2013 SCATS 6.9.1: What’s new – cont’d The major changes in this version are: Better support and monitoring of secret walks. Improved controller fault management. New variation routines for resetting the state and implementing a logical AND between tests. Ability to import the SCATS host licence name and licence details from the licence file into the two configuration programs

6 SMUG 2013 SCATS 6.9.1: New Features - 1 Time Gain Changes The rule introduced in v that time gain could only be accepted from phases that were allowed to gap has been removed! A sanity test is now applied to time gain at the end of each phase that fixes TG build-up observed in Master-Isolated mode and skipping of the stretch phase. Time can now be gained from skipped phases when a dwell is applied.

7 SMUG 2013 SCATS 6.9.1: New Features - 2 Walk monitoring – includes secret walks An RPS request is now sent to all controllers every second to get the demanded walks and the active walks. Site diagnostic monitor (IDM) files now show when a walk ended rather than when a walk termination request was sent. The capture of the intersection status when an SC, LC or IH alarm is generated will also show secret walks (eg More… in Access).

8 SMUG 2013 SCATS 6.9.1: New Features - 3 ST alarm (NXP) review The failure of a controller to answer an NXP/CLP message within 8 seconds now generates Fallback instead of an ST alarm. An ST is generated only when no messages at all are received for 8 seconds. Generate an ST alarm if NXP reply is 16 seconds late – TS mode The processing of the Special Facilities for an intersection (Y-, Z-, Z+, Z1-6, XSF, RSF) are now done for intersections that are not communicating as they could be used by Variation Routines.

9 SMUG 2013 SCATS 6.9.1: New Features - 4 Improved controller fault log management SCATS can now detect a deadlock when a controller fault log is being automatically retrieved. The fault is logged and SCATS will retry after 60 seconds which allows RAM/IMAP changes to be saved. The controller log can now be saved to the SCATS log file when a controller has a WD alarm. The AL/ command in SCATS Terminal now resets the flag that allows an RLE fault (Read Log Entry) to be logged.

10 SMUG 2013 SCATS 6.9.1: New Features - 5 Variation Routines New variation routine to AND (VR18), implemented. ­When "test" routines follow each other, there is an implied AND between the routines. ­When an OR is used (VR19), as in A OR B AND C, you get A or (B AND C). ­If you want (A OR B) AND C you must use VR18 for the AND. ­VR18 also allows (A OR B) AND (C OR D) VR83 (Test an SA for congestion) now compares the user supplied DS against the DS from the SI, not the split plan vote DS.

11 SMUG 2013 SCATS 6.9.1: New Features - 6 Variation Routines A variation routine (VR10) has been added to reset the variation routine state to true It is now recommended that you use VR10 instead of VR19 (the OR routine) if you need to reset the state. The Variation Routine Usage dialogue now includes the stop routine (VR0) and longer descriptions.

12 SMUG 2013 SCATS 6.9.1: New Features - 7 Variation Routines All the variation routines are now shown in the Variation Routine Monitor dialogue with an icon and description. The icon identifies the type of variation routine or whether it has been skipped, bypassed or is unknown. A shortcut menu provides a legend for the meaning of the icons.

13 SMUG 2013 SCATS 6.9.1: New Features - 8 SCATS Flags All flags except MSS can be locked or trimmed to an ON state or an OFF state. Each flag is managed separately. A trim cannot be applied if the flag is locked. SF and XSF locks no longer require a split plan lock to be applied (i.e. no PL=0#! Needed) SF and XSF trims clear on a split plan change.

14 SMUG 2013 SCATS 6.9.1: SCATS Flags - 1 Flag Types SF Special Facilities: Y-, Z+, Z- No Change XSFExtra Special facilities Increased from 16 to 32 including Flexilink plans, VC6.1 MSSMiscellaneous Status Increased from 16 to 32 including Flexilink plans, VC6.1 ZZ1 to Z6 No Change RSF Remote Special facilities Increased from 16 to 32, any controller

15 SMUG 2013 SCATS 6.9.1: SCATS Flags - 2 Indication of a trim or a lock in Access No flag locks or trims At least one flag is trimmed, no locks At least one flag is locked, there can be trims

16 SMUG 2013 SCATS 6.9.1: SCATS Flags - 3 The Special Facilities form ­Shows current state of all flags ­Indicates the presence of locks and trims At least one lock, there can be trims At least one trim, no locks No locks or trims

17 SMUG 2013 SCATS 6.9.1: SCATS Flags - 4 Opening a Flag Selector form ­Click a button for the desired flags ­Can open multiple selection forms

18 SMUG 2013 SCATS 6.9.1: SCATS Flags - 5 The Flags Selector form ­Shows the current state of the flags of that type ­Shows locks and trims ­Apply trims ON or OFF ­Apply locks ON or OFF ­Remove a lock or trim ­Show the Locks and Trims form

19 SMUG 2013 The Flags Selector form ­Applying a lock or trim Select the state ›Click the ON or OFF button Select the type ›No Lock for trim ›Permanent or timed for a lock Click Apply ­Removing a lock or trim Locks and trims are shown in the top section Select the lock or trim to be removed ›Click the button with the lock or trim icon Click Apply SCATS 6.9.1: SCATS Flags - 6 Trimmed ON Locked OFF

20 SMUG 2013 SCATS 6.9.1: SCATS Flags - 7 Displaying details of locks and trims ­Click the “Locks and Trims…” button on the Special Facilities form or the Flags Selector form to display the Locks and Dwells form. Shows if flag state is ON or OFF

21 SMUG 2013 SCATS 6.9.1: New Features - 9 Network intersection IP addresses are now persistent, * indicates inactive

22 SMUG 2013 SCATS 6.9.1: New Features - 10 IP address of GUI client is always displayed in Workstation list

23 SMUG 2013 SCATS 6.9.1: New Features - 11 Ability to monitor ISS stretch phase bias in Access Form is rearranged!

24 SMUG 2013 SCATS 6.9.1: New Features - 12 Short-cuts defined for SI/SA/LK configuration forms to show their monitor forms, and vice versa

25 SMUG 2013 SCATS 6.9.1: New Features - 13 Region request log message message format is modified to include unknown site request as specified below, "region request at CM from SENDER_IPADDR for Site SITEID replied with (REGNAME at REG_IPADDR:REG_NETPORT)" or "region request at CM from SENDER_IPADDR for Unknown site SITEID"

26 SMUG 2013 SCATS 6.9.1: New Features - 14 Allow master subsystem to rotate (correcting offset errors) Early study results ­Increased number of rotations while ­Reduced CL modifications ­Applies between 2 to 10 subsystems

27 SMUG 2013 SCATS 6.9.1: New Features - 15 Force controller clock update even if site is on fallback New Region option RK=RC or IK=RC A new Reset Clock button to force a clock update Good for customers who do not use Flexilink

28 SMUG 2013 SCATS 6.9.1: More features VE alarms can be cleared – validation retry is reattempted. The change of a controller's dimmed lamp state is now logged ­The current state is also logged at midnight. The Fallback panel in SCATS Access is no longer set by an intersection on fallback that's a member of a subsystem that's on fallback. ­Additionally, intersections that are members of a subsystem that is on fallback are no longer included in the fallback summary display

29 SMUG 2013 SCATS 6.9.1: More features Number of dwell stores has been increased from 4 to 30 Number of simultaneous IDM collections increased from 30 to 64 Limit for daily average volume (AV) increased from to Copy contents of Location field into the Remarks field ­by double clicking on the remarks field in SCATS Access Route Plan editor

30 SMUG 2013 SCATS 6.9.1: Issues addressed - 1 Reported lamp faults are now displayed in System Status Summary

31 SMUG 2013 SCATS 6.9.1: Issues addressed - 2 Copying an intersection’s data with the "Use" button now works

32 SMUG 2013 SCATS 6.9.1: Issues addressed - 3 Menu shortcuts (Ctrl+C, Ctrl+X, Ctrl+V, etc.) were not enabled as specified so it was not working all the time

33 SMUG 2013 SCATS 6.9.1: Issues addressed - 4 Buffer overflow reported by VicRoads when there CM crashed Region crash during sending region status message ­ last intersection in the defined slots has an LF loop count loses its value and crashes Region crash when logging an FTP lock Region crash when saving Variation Routine 5 in SCATS Access before nominating an MSS bit

34 SMUG 2013 SCATS 6.9.1: Issues addressed - 5 TG calculations (bug fix) ­No time gain is obtained from skipped phases when a dwell is applied ­Master Isolated - TG wrongly builds up from a number of cycles SI phase time not being set to zero when being skipped Any intersection with > 4 split plans and 7 phase (TCS 2861) ­The details in Access not shown correctly – first 10 – 15 sec ­Reported as incorrect Hurry call operation and showing locks/trims that are not applicable

35 SMUG 2013 SCATS 6.9.1: Issues addressed - 6 Variation routine monitor ­The on-entry and on-exit values displayed is wrong for VR98 (Skip next entry on FALSE) and VR99 (Skip next entry on TRUE) VR15 (the count routine) does not clear the SCATS flags if the count type is changed Skip checkbox missing for VR99 (Skip next entry on TRUE)

36 SMUG 2013 SCATS 6.9.1: Issues addressed - 7 Actual link mode is shown and updated in Time/Distance diagram Flexilink data dialogue ­validation check for an invalid pulse time highlights incorrect field SCATS Log ­Log includes parked alarms and events if a site (s) is specified in the filter Alarm Analyser ­Machine re-start reported as crash on Windows Server 2008 R2

37 SMUG 2013 SCATS 6.9.1: Release available SCATS Release is available and recommended to deploy. Release notes must be reviewed prior to installation. User Manuals are up to date. HASP Device drivers are updated. Need a new licence – contact SCATS Help!

38 SMUG 2013 SCATS 6.9.1: Known issues SCATS Flags (child dialogues) not updated when monitored site changed Communications status not updated in 'Controller communications' dialogue Invalid input to Local (or Controller) Times would yield a deadlock in SCATS Access

39 SMUG 2013 SCATS 6.9.1: Known issues DO NOT USE – RK=LS! 16 plans – do not overload variation routines New Access ( > ) with old region ( and ), increase number of plans in Site Edit destroys the slot data – site configuration is lost

40 SMUG 2013 SCATS 6.9.2: Next step Maintenance Release is now compiled. Objective of SCATS is to provide a maintenance release addressing outstanding defects and change requests. Scope to resolve all outstanding major defects for greater system stability and reliability. A few enhancements are in consideration.