Receiver Bandwidth affects signal-to-noise ratio (SNR)
Advertisements

Assessment of tumoural ADC’s in rectal Tumours using Burst: New methodological Developments SJ Doran 1, ASK Dzik-Jurasz 2, J Wolber 2, C Domenig 1, MO.
Image Reconstruction.
Magnetic Resonance Imaging
MRI Phillip W Patton, Ph.D..
MR Sequences and Techniques
Statistical Parametric Mapping
Section 1 fMRI for Newbies
Digital Radiography.
Chapter 14: Artifacts Mark D. Herbst, MD, PhD. Artifact Something on the image that does not represent something in the patient –Many causes Equipment.
Parameters and Trade-offs
Topics spatial encoding - part 2. Slice Selection  z y x 0 imaging plane    z gradient.
Basics of fMRI Preprocessing Douglas N. Greve
Chapter 9 Basic MRI I Mark D. Herbst, MD, PhD. Notice This lecture contained many drawings on the whiteboard, so get these from one of the other students.
Terry M. Button, Ph.D. Principals of Magnetic Resonance Image Formation.
Encoding and Image Formation
Original image: 512 pixels by 512 pixels. Probe is the size of 1 pixel. Picture is sampled at every pixel ( samples taken)
Noise SNR and CNR Types of noise Thermal noise SNR - definitions
FMRI: Biological Basis and Experiment Design Lecture 7: Gradients and k-space FFT examples –Sampling and aliasing Gradient Gradient echo K-space
FMRI: Biological Basis and Experiment Design Lecture 12: Signal-to-Noise Ratio Things that determine signal strength –voxel size –RF coil Things that determine.
FMRI: Biological Basis and Experiment Design Lecture 8: Pulse sequences, Take 2 Gradient echo review K-space review Slice selection K-space navigation.
Compressed Sensing for Chemical Shift-Based Water-Fat Separation Doneva M., Bornert P., Eggers H., Mertins A., Pauly J., and Lustig M., Magnetic Resonance.
Tissue Contrast intrinsic factors –relative quantity of protons tissue proton density –relaxation properties of tissues T1 & T2 relaxation secondary factors.
RF Coils Used In MRI.
대구가톨릭대학병원 영상의학과 이 영 환 M M R R Basic Physics. MR Signal T1-, T2-weighted TR, TE MR Signal T1-, T2-weighted TR, TE.
Principles of MRI Physics and Engineering
Basic principles Geometry and historical development
Imaging Sequences part II
The comparison of MRI imaging In 3.0 T & 1.5T By a.r.shoaie.
Statistical Parametric Mapping Lecture 9 - Chapter 11 Overview of fMRI analysis Textbook: Functional MRI an introduction to methods, Peter Jezzard, Paul.
Medical Imaging Systems: MRI Image Formation
Jeff Binder R.T. (R). STRENGTHSWEAKNESSES  Readily available  Low cost  Well known uses  Best line pair performance  False negatives (fx)  Ionizing.
Stimulus Presentation and Image Acquisition Valentina Petre.
HOW TO OPTIMIZE MRI OF EXTREMITIES ?
Pulse sequences.
Chapter 6 Lecture Spin Echo Imaging Methods Mark D. Herbst, MD, PhD Two Main Types of MR methods –Spin Echo –uses RF pulse to get an echo –Gradient Echo.
RT 4912 Review (A) Rex T. Christensen MHA RT (R) (MR) (CT) (ARRT) CIIP.
Rad T 265 MRI Lecture. No Magnetic Field = No Net Magnetization Protons align with a magnetic field…
The basic story – fMRI in 25 words or less!. fMRI Setup.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D.. Image Detail and Noise Two image characteristics that reduce the visibility of anatomy/pathology –Blurring.
ExactEstimate 300 msec.
Brit and the Rad Lab at MIT Radiation Laboratory Series: Documented developments from the Rad Lab Volume 19 (copyright 1949): Waveforms- edited by B. Chance.
Protons (hydrogen nuclei act like little magnets) MRI Collective Magnetic Moment of Protons (M 0 ) Each pixel is a glass of protons B 0 = 3T (not to scale)
Basic MRI Chapter 1 Lecture. Introduction MRI uses radio waves and a magnetic field to make images MRI uses radio waves and a magnetic field to make images.
Anna Beaumont FRCR Part I Physics
V.G.Wimalasena Principal School of Radiography
MRI Physics: Spatial Encoding Anna Beaumont FRCR Part I Physics.
Declaration of Relevant Financial Interests or Relationships David Atkinson: I have no relevant financial interest or relationship to disclose with regard.
Magnetic Resonance Learning Objectives
Receive Coil Arrays and Parallel Imaging for fMRI of the Human Brain
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
TISSUE HARMONIC IMAGING (THI)
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Chapter 5 Mark D. Herbst, M.D., Ph.D.. The MR Imaging Process Two major functions –Acquisition of RF signals –Reconstruction of images.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
FMRI data acquisition.
TELEVISION Camera Tube
Sunday Case of the Day Physics
بسم الله الرحمن الرحيم.
Magnetic Resonance Imaging: Physical Principles
Bioengineering 280A Principles of Biomedical Imaging Fall Quarter 2005 MRI Lecture 5 Thomas Liu, BE280A, UCSD, Fall 2005.
An Optimal Design Method for MRI Teardrop Gradient Waveforms
Parallel Imaging Artifacts in Body Magnetic Resonance Imaging
Chapter 11 Lecture Mark D. Herbst, M.D., Ph.D..
Basic MRI I Mark D. Herbst, MD, PhD
Basic principles Geometry and historical development
MRI ARTEFACTS PG Student : Dr Aditi Shah PG Guide: Dr Rajendra Chavan
A, Sagittal T1 MR imaging. A, Sagittal T1 MR imaging. Multiple bone lesions with T1 hyperintensity involve the cervical and thoracic spine, with a pathologic.
Left, T1 spin-echo image at 1
Same section position with spin-echo T1-weighted sequences at 1
Presentation transcript:

Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D.

Image Detail and Noise Two image characteristics that reduce the visibility of anatomy/pathology –Blurring – level of detail – related to pixel size –Visual Noise – random bright and dark dots These two are related, because if you improve one, you worsen the other.

Other image characteristics also impact visibility of anatomy/pathology Camouflage Irregular borders Low contrast Motion (blurring)

In-Plane Resolution This is a photo that has been taken at 165x256 resolution

In-Plane Resolution This is a photo that has been taken with 329x512 resolution

In-Plane Resolution Original Resolution 720x1150

What is the MR image? Really just a display of the signal intensities from the voxels in the patient as pixels. No detail is seen within a voxel (pixel).

Voxels, FOV, and Matrix size Pixel size = FOV / matrix size Voxel size = pixel size x slice thickness FOV = field of view – can be square or rectangular (i.e., 25 cm x 25 cm, or 25 cm x 20 cm) Matrix = how many pixels in the image, square or rectangular (i.e., 256 x 256, or 256 x 192)

Exercise What is the voxel size? –FOV = 25 cm, Matrix = 256 x 256, ST = 1 mm –FOV = 13 cm, Matrix = 256 x 128, ST = 1 mm –FOV = 50 cm x 25 cm, Matrix = 512 x 256, ST = 5 mm

How detailed must the image be? The goal is to select the optimal voxel size for the anatomy and pathology you want to see

Sources of Noise The patient’s body Electrical devices – radio, TV, lights, motors, etc.

Signal-to-Noise Ratio(S/N) Two ways to increase S/N –Increase signal –Decrease noise

How to increase S/N Increase voxel size—this increases S –Done by increasing ST or increasing pixel size Increase field strength –increases S because S increases with increasing B 0 –Also increases N, but not as much as S, so S/N increases

How to increase S/N Adjust TR and TE – longer TR and shorter TE lead to increase S, and therefore, increased S/N Use better RF receive coils –Body coils are worst, small surface coils are best –New multicoil designs increase S

How to increase S/N Decrease receive Bandwidth (BW) BW = 1/(dwell time) Problem of increased chem shift artifact with decreased BW If you increase BW to decrease chem shift, you get more noise

How to increase S/N Signal averaging The number of signals averaged (NSA), or the number of excitations (NEX) or the number of acquisitions (NACQ) all mean the same thing. It is like taking multiple pictures and adding them together. The noise does not increase as much as the signal. S/N ~ sqrt (NEX), so 4 NEX doubles S/N

Signal-to-Noise

Signal-to-Noise

Signal-to-Noise

Signal-to-Noise

AVERAGING

BANDWIDTH LARGE (WIDE) SMALL (NARROW)

BANDWIDTH = 1/(DWELL TIME)

DWELL TIME SHORT sample of echo LONG sample of echo

PELVIS FOV 340 RFOV 65 Slice 7mm Matrix 256 Scan Percent 60 NSA 4 Time 5:54

KNEE FOV 160 RFOV 80 Matrix 256 Scan Percent 90 Turbo Spin Echo Slice 4 mm NSA 2 Knee Coil Time 2:28

WRIST Gradient Echo 3D Volume Acq. FOV 100 RFOV 80 Matrix 256 Scan Percent 80 Slice 2.4 mm Time 3:52

PROTOCOL FACTORS AFFECTING IMAGE DETAIL IMAGE NOISE Slice Thickness Matrix Size FOV Slice Thickness Matrix Size FOV Coil Selection Averaging Bandwidth TR and TE Field Strength