Characterization of short pulses.

Slides:



Advertisements
Similar presentations
Measuring Ultrashort Laser Pulses II: FROG
Advertisements

Measuring Ultrashort Laser Pulses IV: More Techniques
Pulsed Fiber Laser Autocorrelator
Speaker: Tzung Da Jiang Adviser : Dr. Ja-Hon Lin
Design and construction of a mid-IR SPIDER apparatus 09/10/2012 Malte Christian Brahms Imperial College London 09/10/20121.
Ultrafast Experiments Hao Hu The University of Tennessee Department of Physics and Astronomy, Knoxville Course: Advanced Solid State Physics II (Spring.
LC-ABD P.J. Phillips, W.A. Gillespie (University of Dundee) S. P. Jamison (ASTeC, Daresbury Laboratory) A.M. Macleod (University of Abertay) Collaborators.
05/03/2004 Measurement of Bunch Length Using Spectral Analysis of Incoherent Fluctuations Vadim Sajaev Advanced Photon Source Argonne National Laboratory.
Ultrafast XUV Coherent Diffractive Imaging Xunyou GE, CEA Saclay Director : Hamed Merdji.
Space-time positioning at the quantum limit with optical frequency combs Workshop OHP September 2013 Valérian THIEL, Pu JIAN, Jonathan ROSLUND, Roman SCHMEISSNER,
S. Varma, Y.-H. Chen, and H. M. Milchberg Institute for Research in Electronics and Applied Physics Dept. of Electrical and Computer Engineering Dept.
© Ceridwen, CC BY-SA Temporal focussing of ultrafast pulses through an opaque scattering medium David McCabe, AyhanTajalli, BéatriceChatel Laboratoire.
Femtosecond Laser Micromachining of BioMEMS BioMEMS Lab Mechanical and Aerospace Engineering University of Texas Arlington.
Measuring Ultrashort Laser Pulses III: FROG tricks
11. Measuring Ultrashort Laser Pulses II: FROG
Generation of short pulses
Single Shot Combined Time Frequency Four Wave Mixing Andrey Shalit, Yuri Paskover and Yehiam Prior Department of Chemical Physics Weizmann Institute of.
A. Zholents, July 28, 2004 Timing Controls Using Enhanced SASE Technique *) A. Zholents or *) towards absolute synchronization between “visible” pump and.
Time-resolved Spectroscopy
Diagnostics for Benchmarking Experiments L. Van Woerkom The Ohio State University University of California, San Diego Center for Energy Research 3rd MEETING.
Stanford - SSRL: J. Lüning W. Schlotter H. C. Siegmann Y. Acremann...students Berlin - BESSY: S. Eisebitt M. Lörgen O. Hellwig W. Eberhardt Probing Magnetization.
Autocorrelator:.
John Arthur LCLS Diagnostics and Commissioning September 22, 2004 Summary of Related Topics from the Miniworkshop on.
Attosecond Metrology A method for attosecond pulse characterisation Adam Wyatt 1 Ian Walmsley 1 Laura Corner 1 A. Monmayrant John Tisch et al 2 Eric Cormier.
ELI: Electronic Timing System (ETS) at Facility Level E L I – B L – – P R E – B.
Ultrafast Experiments Hangwen Guo Solid State II Department of Physics & Astronomy, The University of Tennessee.
Single-shot characterization of sub-15fs pulses with 50dB dynamic range A. Moulet 1, S.Grabielle 1, N.Forget 1, C.Cornaggia 2, O.Gobert 2 and T.Oksenhendler.
30. Nov I.Will, G. Klemz, Max Born Institute: Optical sampling system Optical sampling system for detailed measurement of the longitudinal pulse.
Discussion of measurement methods for femtosecond and attosecond pulses.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
UCLA Frequency-domain interferometry diagnostic system for the detection of relativistic plasma waves Catalin V. Filip, Electrical Engineering Department,
Femtosecond low-energy electron diffraction and imaging
DMP Product Portfolio Femtosecond Lasers Trestles Ti:Sapphire lasers …… fs; nm, mW Mavericks Cr:Forsterite lasers
DS3-DS4 Joint 1 st Task Meeting, Saclay 16 th -17 th May 2005 Matter under extremes conditions Femtosecond Laser Servers Laboratoire Francis Perrin SPAM.
Two-photon absorption standards in the nm excitation range: establishing a correction curve for accurate cross section calibration Nikolay S.
IR/THz Double Resonance Spectroscopy in the Pressure Broadened Regime: A Path Towards Atmospheric Gas Sensing Sree H. Srikantaiah Dane J. Phillips Frank.
07/27/2004XFEL 2004 Measurement of Incoherent Radiation Fluctuations and Bunch Profile Recovery Vadim Sajaev Advanced Photon Source Argonne National Laboratory.
Observation of Excited Biexciton States in CuCl Quantum Dots : Control of the Quantum Dot Energy by a Photon Itoh Lab. Hiroaki SAWADA Michio IKEZAWA and.
Femto-second Measurements of Semiconductor Laser Diodes David Baxter
Imperial College London Imperial College XUV Attosecond Beamline: progress and results to date Charles Haworth Laser Consortium Imperial College London.
S.P. Jamison Femtosecond resolution bunch profile diagnostics ASTeC STFC Daresbury Laboratory, UK S.P. Jamison / Ditanet conference/ Nov 9-11, 2011.
Argonne National Laboratory is managed by The University of Chicago for the U.S. Department of Energy Distortion of single-shot EO sampling techniques.
EO sampling technique for femtosecond beam characterization
R. Kupfer, B. Barmashenko and I. Bar
z n + a n-1 z a 0 = (z – z n ) (z – z n-1 )... (z – z 1 ) and the Measurement of the Shortest Rick Trebino School of Physics Georgia Institute of.
ESRF interest & commitment to (ultra-) fast science with X-rays Kees Scheidt Diagnostics group, Machine division.
Pulse Shaping with MIIPS SASS 8/22/2012 David Nicholson.
TOWARD GENERATION OF HIGH POWER ULTRAFAST WHITE LIGHT LASER USING FEMTOSECOND TERAWATT LASER IN A GAS-FILLED HOLLOW-CORE FIBER Walid Tawfik Physics and.
Electro-optic Longitudinal Profile Diagnostics S P Jamison, Accelerator Science and Technology Centre, STFC Daresbury Laboratory S.P. Jamison, Daresbury.
February 17-18, 2010 R&D ERL Brian Sheehy R&D ERL Laser and laser light transport Brian Sheehy February 17-18, 2010 Laser and Laser Light Transport.
Single-shot, Sub-picosecond, EO bunch measurements at FELIX Steven Jamison, Giel Berden, Allan MacLeod Allan Gillespie, Jingling Shen, Dino Jaroszynski,
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
The dilemma The goal: measuring the intensity and phase vs. time (or frequency) Why? The Spectrometer and Michelson Interferometer 1D Phase Retrieval.
Photonics Carlo Altucci Consorzio Nazionale Interuniversitario di Struttura della Materia – CNISM Dipartimento di Scienze Fisiche, Università.
Status of the SPARC laser and “dazzler” experiments
Ultrashort pulse characterisation
Ultrashort pulse characterisation
Spectral methods for measurement of longitudinal beam profile
Introduction to MOSAIC, SHG-FROG, and GRENOUILLE
The right tool for a given measurement: An overview
Spectral Phase Interferometry for Direct Electric-field Reconstruction
Principle of Mode Locking
Kansas Light Source Upgrade
電磁波或光 但如此相干coherent的光很不容易形成! 不相干的光極易發散!
Laser-assisted photoionization for attosecond pulse measurements
SASE FEL PULSE DURATION ANALYSIS FROM SPECTRAL CORRELATION FUNCTION
X-ray Pump-Probe Instrument
Linac Diagnostics Patrick Krejcik, SLAC April 24, 2002
LCLS Injector Laser System Paul R. Bolton, SLAC April 24, 2002
LUSI Status and Early Science
Presentation transcript:

Characterization of short pulses. A. Yartsev

What is good to know about short pulses? Energy of each pulse Average power Spectrum Spatial distribution Temporal profile Satellites Duration Shape

Energy/Power measurements. from pico-Joule to peta-Watt Physics of detection Choice of detector Linearity Sensitivity Spectral response Response time Damage

Spectral shape What do you need the spectrum for? Sensitivity range. Calibration of the spectrometer. Dynamic range. Optics on the way. Fibber ”wave guides”.

Beam profile Assume Gaussian? Measure real profile. Measure power through calibrated pinholes Blade-edge method Measure real profile. 2-D detector: CCD matrix 1-D array detector Linearity of response

Temporal profile: What for? Satellites: quality of amplification, quality of measurements Pulse duration: FWHM Instrumental response function Transform-limited pulse Pulses of random shape

Electrical (direct) measurements of pulse duration: not fast enough and (very) expensive. Photodiode: >10 ps (+fast Oscilloscope) Streak Camera: 100 fs (?), ~1 ps

All-optical methods Time from distance: 1 fs  0.3 m Math: correlation function determines F(t) if G() is measured and F’(t) is known.

Autocorrelation Interferometric AC Intensity AC Single – shot AC Both F(t) and F’(t) are replica’s of the same function E(t)exp

Interferometric AC F(t) = E(t)exc[it+i(t)] I1() = |E(t)exc[it+i(t)] +E(t-)exc[i(t- )+i(t-)]|2dt I2() = |{E(t)exc[it+i(t)] +E(t-)exc[i(t- )+i(t-)]}2|2dt First order AC: I1(=0)/I1() = 2 Second order AC: I2(=0)/I2() = 8

Interferometric AC

Interferometric AC

Limitions of AC Non-specific: one has assume a particular pulse shape. Returns only amplitude.

Full-field characterization of femtosecond pulses by spectrum and cross-correlation measurements OPTICS LETTERS / Vol. 24, No. 23 / December 1, 1999 J. W. Nicholson, J. Jasapara, and W. Rudolph F. G. Omenetto and A. J. Taylor

Frequennsy-resolved optical gating FROG Rev. Sci. Instrum., Vol. 68, No. 9, September 1997 R. Trebino, K. W. DeLong, D. N. Fittinghoff, J. N. Sweetser,

FROG Rev. Sci. Instrum., Vol. 68, No. 9, September 1997 R. Trebino, K. W. DeLong, D. N. Fittinghoff, J. N. Sweetser,

Single-shot FROG

FROG

Limitions of FROG Requirements on set-up: linear detector response, step size, S/N. Delay-scanning technique. Measures 2D characteristic – long. Non-specific: needs a (complicated) retrival to get pulse. Does not always converge.

X-FROG: spectrally-resolved cross-correlation of an unknown pulse with the reference pulse.

TADPOLE Rev. Sci. Instrum., Vol. 68, No. 9, September 1997 R. Trebino, K. W. DeLong, D. N. Fittinghoff, J. N. Sweetser,

FRPP: pump-probe FROG OPTICS LETTERS / Vol. 27, No. 13 / July 1, 2002 S. Yeremenko, A. Baltuˇska, F. de Haan, M. S. Pshenichnikov, D. A. Wiersma

Self-Referencing Spectral Interferometry for Measuring Ultrashort Optical Pulses SPIDER IEEE J Quant.Elctr. Vol. 35, No. 4, April 1999 C. Iaconis, I.A. Walmsley

SPIDER

Advantages of SPIDER No moving parts Direct reconstruction (>1kHz) Noise immunity Low sensitivity to detector spectral response Precision and consistency mesures from data

Limitions of SPIDER Has to be optimised for a particular time-and spectral range. Requires calibration. Very sensitive to delay between pulses – sensitive to alignment.

After SPIDER: ZAP-SPIDER

After SPIDER: SEA-SPIDER E. M. Kosik and A. S. Radunsky I. A. Walmsley C. Dorrer OPTICS LETTERS Vol. 30, No. 3, 2005

After SPIDER: 2DSI OPTICS LETTERS / Vol. 31, No. 13 / July 1, 2006 J. R. Birge, R. Ell, F. X. Kärtner