Paint Circulation Technology Level 1 - Training Document

Slides:



Advertisements
Similar presentations
CONTROLS OF SUPER CRITICAL BOILERS
Advertisements

Commissioning Approach Integrated Service Solutions
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Generic Pressurized Water Reactor (PWR): Safety Systems Overview
ACTIVE LEARNING PROCESS
Energy Efficient Steam Systems
Mountings & Accessories
Paint Circulation Technology Level 2 - Training Document
WHO - PSM Water –part 3 Workshop on GMP and Quality Assurance of HIV products Shanghai, China 28 Feb - 4 March 2005 Maija Hietava M.Sci.Pharm Quality Assurance.
Hot water heating yesterday.... Hot water heating … and today n Principle –Heating system n Heat source n Distribution network n Heat emitter –Heat transfer.
1 Reminder: Resistivity (ohms) is the reciprocal to conductivity (micro-Siemens)
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
STEAM TRAPS.
FoamPro 1600 Series Fully automatic Class A foam ONLY
Components of HVAC System
SANITARY DESIGN PRINCIPLES FOR FACILITIES. ZONES OF CONTROL.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Watertube Boiler.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Mini Jet Sample Dyeing M/C Daelim Starlet Co., Ltd.
GNI0003H PP1 Loop Trainer. GNI0003H PP2 Reason for Study Because the Loop Trainer gives instructors the capability to control water flow, pressure and.
Reservoirs Covered in Ch. 5 of Vickers Text
Filling, purging and air removal
Resource Conservation and Recovery Act.
Diesel Generator Reliability: Lessons Learned from Storms
Green Building Design Scott Lowe Professor Civil and Environmental Engineering Department Manhattan College.
HYDRO-ELECTRIC POWER PLANT Prepared by SREEJITH K. & NICE MENACHERY APME APME JEC JEC.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Skilled Trades 1201 Residential Plumbing.
Unit 206: Domestic hot water systems
POWER PLANT.
Chapter 12: Alternative Technologies To be used with the Guide to Building Energy Efficient Homes in Kentucky.
LNG Hazards.
Pollution Prevention for Paint & Body Shops Miami-Dade County Department of Environmental Resources Management.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
HVAC523 Circulator Pumps.
HVAC523 Basic Subsystems.
Flammable and Combustible Liquids Presented by Martina Schmeling Adapted From OSHA.
Air Conditioning International Mechanical Code
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
ANL Bubble Chamber Superheated Active Target System B. DiGiovine N 2 O and C 2 F 6 as Active Fluids.
F LORIDA S OLAR E NERGY C ENTER Creating Energy Independence Since 1975 A Research Institute of the University of Central Florida Northern Climate System.
CMS FPIX Cooling System Studies Joe Howell, Fermilab for the FPIX Upgrade Mechanical Working Group CMS Upgrade Workshop April 27,
1 HVACR316 - Piping Copper Tubing and Fittings. 2 2 Safety Refrigerant cylinders should be stored and transported in the upright position to keep the.
Solar Heating/Cooling/Dehumidifier Systems
Spray Booths Follow safe operating instructions. Spray-finishing operations  Organic materials  Inorganic materials  Dispersed form  Deposited to.
Engine Performance BASIC MAINTENANCE AND LIGHT REPAIR.
Module 10-1 (a) Manual Gun Cleaning Processes n Manual equipment cleaning generates large quantity of wastes if not done properly. n Solvent is exposed.
Building 180 NORMATEF TEST FACILITY Demineralized cooling water station upgrade R. Bozzi / EN-CV.
How do we harvest rainwater and why should we.. Why Harvest Rainwater? Decrease the volume of potable water used for irrigation. Recharge the groundwater.
The C.I. Engines Fuel System  The C.I. engine demands that the fuel supplied is –  Timed to inject when the piston is near the end of the compression.
Knit Dyeing Machines.
Flammable Liquids Directorate of Training and Education
Welcome! Drafting 2323: Pipe Drafting Andrew Amini Full Time Instructor, HCC.
Industrial Resources, Inc.
It’s…….
Automotive Heating And Air Conditioning
Desert Cooler.
COMPONENTS OF SOLAR WATER HEATER
Vertical Pressure Filters
1 INTERNATIONAL MARITIME COLLEGE OMAN PROCESS TECHNOLOGY & SYSTEMS (TPTS & PT-TPTS) PE (TPTS & PT-TPTS) (Chapter-3) Chapter - 3 Distillation Systems Textbook.
Spray Booths Follow safe operating instructions
Presentation transcript:

Paint Circulation Technology Level 1 - Training Document Subject Matter Expert: Miguel Bahena

What Is A Paint Circulating System A pressurized vessel used to transport material to various locations. More efficient then manual moving material to individual locations.

Sounds simple doesn’t it? What Are We Doing? Moving material from point A to point B. Supply material fluid pressure. Supply material fluid flow. Maintain material integrity. That is all we do! Sounds simple doesn’t it?

What Are We Doing? Point A Point B

PAINT MIX ROOM Typical paint mix room The martial that is used for painting the vehicles is a solvent borne material which is extremely flammable. The paint is stored and pumped from a paint mix room. MIX ROOMS ARE CLASS 1 DIVISION 1 AREAS – NO ELECTRIC ITEMS ARE ALLOWED IN THIS ROOM INCLUDING – (CELL PHONES, FLASH LIGHTS, RADIOS, ETC). UNLESS APPROVED BY FORD SAFETY Tote storage rack Tote stand for loading material Bulk Storage Tank for Solvent and Waste Typical circulation system Typical paint mix room

Typical Paint Circulation System Components Transfer Pump Surge Chamber Day Tank BPR Pump Supply Line Tote Tank Return Line Booth Drops Heat Exchanger

PAINT CIRCULATION HEADER Typical paint circulation header The paint is pumped from the paint circulation module to the spray booths in what is called a header system. The headers system is constructed from stainless steel pipe/tubing and delivers paint to each robot or manual spray station. At each robot or manual station, a line tee’s off the header to feed this station. This is called a drop/paint station. Typical paint circulation header

PAINT HEATEXCHAGNER SYSTEM The paint must be applied to the vehicle at the correct temperature. A paint heat exchanger system is used to maintain a temperature of +/- 2 degrees F Tube and shell heat exchanger Water supply and return lines Water conditioning skid

WASTE COLLECTION SYSTEM Each time the robot or manual station changes color a certain amount of waste is generated. This waste is collected at the paint booth in a waste collection system. Special Waste Collection Funnel Under Cap Cleaner to Flush Drop Legs and Prevent Debris from Entering Waste Header Recirculation of the header and drop legs are very important Gravity Waste Header Fabricated from 2” S.S. Tubing Utilizing Sanitary Fittings for Smooth ID and Ease of Maintenance. Line Installed at ¼” – 3/8” per foot to maintain proper drain velocity Ball Valves Added to Header to Have the Ability to Power Flush Header for Preventative Maintenance Purge Solvent Piped to Tank so Virgin Solvent Can be Added for Cleaning. A Catalyst Stop can be Substituted to Prevent the Catalyst from Curing (paint supplier can recommend material) Special Cage Inside Tank to Capture 2K Waste Debris From Clogging Pumps Utilize (1) Pump for Recirculation and (1) Pump for Empting of the Tank Note: Containment Pan Not Shown