Preparing for Accreditation Jerry L. Parr Catalyst Information Resources, L.L.C. TNRCC Trade Fair May 7, 2002
NELAC Accreditation: Start to Finish 1. Deciding to apply 2. Understanding the requirements 3. Getting ready 4. Accreditation process
Key Documents NELAC Standards Assessor Training Manual National Standards for Water PT NELAC PT Tables State Requirements State Fields of Testing
STEP 1: Deciding to Apply Your state’s requirements Improve data quality Customer expectations Marketing advantage
NELAC Improves Data Quality Implementation of a Quality System Improved documentation Standardized policies and procedures Ethics program Improved technical procedures
Customer Expectations EPA SDWA OSWER OIG DOD Industry
Marketing Considerations Recognized standard of excellence Use of logo Reciprocity = geographic expansion
The Application 20 detailed items Certificate of compliance Fields of testing Quality manual Fee State options
Required Elements in Application Legal name of lab Address Owner (and address) Location Name and phone of TD, QAO, contact Hours of operation Primary AA Fields of testing Methods employed (with analytes) Lab type
Certificate of Compliance Attest to compliance to NELAC standards Signed by Technical Director & QA Director
Fields of Testing Area: Chemistry, Microbiology, WET, Radiochemistry, Field Activities Program SDWA, CWA, RCRA, CAA (TSCA, FIFRA, CERCLA) Changes to be made in 2002 Method/Analyte Change to technology? Include analyte group?
STEP 2 - Understanding the Requirements Proficiency Testing Quality System Personnel Qualifications
PT Program Review Two PT samples per year per field of testing where available Purchase from any approved supplier Uniform acceptance criteria Pass 2 out of last 3
NELAC QUALITY SYSTEM Elements documented in quality manual Policies and objectives and commitment to accepted laboratory practices and quality of testing services Annual internal audit and management review
NELAC Quality Manual Policies and operational procedures established to meet NELAC standard. Probably most significant up-front investment Must address all QS elements Template available from Catalyst
Elements of a Quality System Personnel Physical facilities Equipment and reference materials Measurement traceability and calibration Test methods and SOPs Method verification (Appendix C)
Elements of a Quality System (2) Sample handling Records and storage of records Laboratory report format and content Subcontracting Complaint procedures Essential QC Procedures (Appendix D) Chemical, WET, Micro, Radiochemistry, Air
Sample Handling Sample tracking Sample acceptance Sample receipt Sample storage Legal chain of custody Sample disposal
Calibration Traceability of calibration Reference standards General requirements Analytical support equipment Instrument calibration
QA/QC Document control Acceptable permitting departures from documented policies, procedures, & specifications Corrective action Complaint handling Preventive action Internal audits Developing acceptance criteria when no method or regulatory requirement exists
Data Review and Reporting Data review Reporting analytical results Electronic reporting Record retention Records transfer Data integrity Data security
Test Methods May be copies of published methods Must address 23 elements
Essential Quality Control Required activities, acceptance criteria and corrective action for: D.1 Chemistry D.2 WET Testing D.3 Microbiology D.4 Radiochemistry D.5 Air
Chemistry QC Method Blanks LCS MS Surrogates Detection Limits Selectivity Major revision in 2001 Standards
Detection Limit Determination Appropriate (e.g., MDL) Limited exceptions (e.g., temperature) Each Matrix (see Glossary) Link to Quantitation Limit Redo if “significant change” Link to instrument calibration
Demonstration of Capability All methods 4 replicates at 10 X DL Compare X and s to acceptance criteria Limited exceptions “Work cell” provision Certification statement Exception in 2001 standards for methods in use before July 1999
Analyst Proficiency One of the following at least once per year: Single blind DOC PT sample 4 LCS Sample analyzed by another
STEP 2 - Understanding the Requirements Proficiency Testing Quality System Personnel Qualifications
Technical Director Full time employee Oversee all lab operations QA/QC Data being generated Sufficient qualified personnel “One or more” may be appointed
TD for Chemical Analysis Bachelor’s degree in chemical, environmental, biological sciences, physical sciences, or engineering 24 college semester credit hours in chemistry 2 years of experience in environmental analysis Master’s or Ph.D. may be substituted for 1 year experience
TD for Inorganic Analysis (non metals) Associate’s degree in chemical, physical or environmental sciences or 2 years college education and 16 semester credit hours in chemistry 2 years of experience
TD for Microbiology Bachelor’s degree in microbiology, biology, chemistry, environmental sciences, physical sciences, or engineering 16 semester credit hours in general microbiology and biology 2 years of experience Master’s or Ph.D. may be substituted for 1 year experience
Exception for Microbiology Associate’s degree in science (or 2 years college) with 4 hours in general microbiology and 1 year experience in environmental analysis Limited to fecal coliform, total coliform, & standard plate count
Grandfather Clause Does not meet educational requirements Is the TD on date laboratory “applies” or “becomes subject to” NELAC standards AND has been TD for one year (new for 2001) Can be TD at any other comparable laboratory Limited to first year of program
Exceptions Full-time employee: Of drinking water or sewage treatment facility with valid treatment plant operator’s certificate appropriate for that facility is approved to serve as director of accredited lab devoted to samples taken within facility Of industrial waste treatment facility with 1 year supervised experience is approved as director of accredited lab devoted to samples taken within facility
Quality Assurance Officer May be TD or deputy TD if limited staff Responsible for quality system management & implementation Focal point for QA/QC Documented training and/or experience in QA/QC Knowledge of the test methods Arrange for or conduct internal audits annually Notify lab management of deficiencies in quality system & ensure corrective action No educational or experience requirements
STEP 3 - Getting Ready Organizational Decisions Technical Director Quality Assurance Officer Data Generation PT Sample Data Method Performance Data Documentation Quality Manual SOPs Administrative Information
Organizational Options Multiple TD(s), QAO Singe TD, QAO TD = QAO
Quality Assurance Officer Title is optional Direct access to management May be technical director Specific job functions
Recommendations for TD/QAO Have TD and QAO as 2 positions, if organization will allow Have single TD, if qualifications allow Have deputy TDs for contingency/growth Consider grandfather clause
Summary of Data Needed 2 PT samples results Detection limits Demonstration of capability (not required for methods already in use, but a good idea)
Administrative Information Laboratory organization Personnel training Equipment & reference materials Standards & reagents Other
Laboratory Organization Organization chart Identification of major units Lines of responsibility
Personnel Records Job descriptions Documentation of education/technical background Documentation for each employee relating to quality manual Training records Analyst proficiency
Equipment & Reference Materials Name of equipment Manufacturer & serial number Date received/placed into serviced Current location Condition when received Copy of manufacturer’s instructions Dates of calibration Details of maintenance History Calibration certifications
Standards and Reagents Certificate of analysis Date of receipt Manufacturer/vendor Storage conditions Expiration dates Other information (e.g., sample disposal records)
STEP 4: The Assessment Process
Understand the Assessment Process Assessors (i.e. auditors) Frequency Pre-Assessment On-site Assessment (i.e. the Audit) Assessment Report Corrective Action Closure
Steps to Take Review assessor training manual Review checklist Internal/contractor review Preliminary record submittal SOPs Data package Other information Review due process rules
Your Rights Before the On-Site Checklist(s) Confidentiality notice Conflict of interest form Assessor credentials Mutually agreeable date
Award of Accreditation Certificate Signed by AA, effective dates, NELAC logo Includes fields of testing Must be posted
Staying Accredited Compliance with Chapter 5 PTs (twice a year) On-site (every 2 years) Notification of key changes (< 30 days) Ownership Location Key personnel Instrumentation
Other Important Information EH&S not included Use of logo No supplemental requirements Mobile laboratories Record retention: 5 years
Accredited! Know the standards Decide to apply Get ready Collect information Plan for the On–Site Stay accredited! SUMMARY NELAC
HELP? NELAC Website EPA QA Documents QAMS 005 (print only) QA/G-5 QA/R-5 EPA SOP Guidance OW Streamlining Appendix F (3/28/97 FR) QA/G-6 Catalyst Template Quality Manual SOP Guidance Many other related documents
Jerry L. Parr Catalyst Information Resources, L.L.C. The Information Resource for Environmental Professionals