December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP000181 – Rev. D, en – Presentation – 2010.12.

Slides:



Advertisements
Similar presentations
Molded Case Circuit Breakers for the OEM Market
Advertisements

Seminar on Circuit Breaker
Inspection & Preventive maintenance of breakers
M iniature circuit breakers to UL 489
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
OHB Outdoor sulphur Hexafluoride circuit-Breaker
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
Smaller Simpler Better
FIPTMV Medium Voltage Technology
October, 2009 VM1: innovation in power technology Vacuum circuit-breaker with magnetic actuator Product presentation 1VCP – Rev. C, en – Presentation.
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
Circuit Breakers.
Miniature Circuit Breakers (MCB) Multi 9
Sales Training Outline 2006 Klaus Tum Product Manager NEW Circuit Breakers 35 Royal Road Flemington, NJ
MV SF6 circuit-breakers for secondary distribution
Breaker Basics Welcome to this general overview of ABB.
Innovation within Continuity
Molded Case Circuit Breakers for the OEM Market
MaxSG - Low Voltage Switchgear
Multi-function apparatus for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Medium Voltage Switchgear
Masterpact LV power air circuit breakers and switch disconnectors
Standards LOW VOLTAGE Below or Equal to 1000V for AC & 1200V for DC
Pole Mounted Switch Disconnector NPS
Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE.
AQ 100 Series Arc Flash Protection System. Characteristics of arc protection Speed, no intentional delays Sensitive, current set-points just above loads.
CIRCUIT BREAKER Definition  Device designed to open the circuit automatically under abnormal conditions without damage to itself.
Medium Voltage Outdoor Apparatus Portfolio
A Presentation On 132 KV GSS BEHROR
Main contacts closed – RED Colour with ON
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
ECE 498HZ: Power Distribution System Analysis
5SV9 Residual Current Circuit Breakers with Overcurrent Protection
Frei verwendbar / © Siemens AG Alle Rechte vorbehalten.siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection SENTRON.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
AUTOMATIC CIRCUIT RECLOSER
Circuit Breakers CBI and ETA product offerings. Breaker Technologies - Hydraulic-Magnetic Not effected by ambient temperatures Possible to obtain any.
Product Training Module
PROTECTION AGAINST INDIRECT CONTACT
3AH5 Vacuum Circuit-Breaker For Standard Applications
Sectos NXB and NXBD.
GROUND-FAULT GROUND-CHECK MONITOR
Name, department/event, date
Circuit Breakers & Reclosers
Overview of PowerCube Units and ANSI frames
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Direct Replacement Retrofitting Solution
SION Vacuum Circuit-Breaker For Standard Applications
ELECTRICAL POWER-II Electrical engineering sixth semester
ABB SACE Emax 2 ANSI C37 / UL1066 Concept Global Product Management
Friday, December 28, 2018 ABB SACE Emax 2 Concept
Direct Replacement Retrofitting Solution
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
Presentation transcript:

December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP000181 – Rev. D, en – Presentation – 2010.12 © ABB Group April 16, 2017 | Slide 1

Available versions acc. to IEC STDs Vmax Available versions acc. to IEC STDs Compliance to IEC 62271-100 12 kV … 17.5 kV ; 630 … 1250 A ; 16 … 31.5 kA Fixed for freestanding installation Withdrawable for ABB UniGear ZS1 switchgear (width 550 mm) Withdrawable for ABB PowerCube module (width 600 mm) Fixed for ABB UniGear 500R switchgear (width 500 mm) © ABB Group April 16, 2017 | Slide 2 2

Available versions acc. to ANSI STDs Vmax Available versions acc. to ANSI STDs Compliance to C37.54 – C37.09 – C37.04 – C37.55 UL listed type L (sticker on request) 15 kV ; 1200 A ; 25 … 31.5 kA (3 cycles) Fixed for freestanding installation Withdrawable for ABB PowerCube module (width 600 mm) © ABB Group April 16, 2017 | Slide 3 3

Vmax ANSI version versus IEC version: Shunt tripping releases suitable for “3 cycles” interruption Wiring with UL certified cables (& AWG cross-section) Nameplate with ANSI parameters Mechanical indicators according to ANSI STDs (symbol & colour) Specific Manual Booklet

Vmax Overview Open/close aux. contacts (standard set of ten aux.c.) Additional opening release Locking magnet in the actuator Opening pushbutton Closing pushbutton Shunt tripping release Built-in lever for closing spring manual charging Undervoltage release (missing in the picture) Shunt closing release Signalling device for closing springs charged/discharged Mechanical operation counter Geared motor for closing spring charging

Vmax Overview

Vmax Fields of application Power distribution Cable control and protection Overhead control and protection Transformation and distribution substations Motor and transformer control and protection Generator control and protection Capacitor bank control and protection

Vmax Strenghts Application where space saving is a premium Compact dimensions compared to existing VD4 Freestanding vacuum interrupters Moulded case design

Vmax Features Vacuum interruption technique Contacts in vacuum protected against oxidation and contamination Sealed for life vacuum interrupters Vacuum interrupters and EL mechanical actuator already used and tested in new VD4 series Limited switching energy 10,000 mechanical operations Stored energy operating mechanism with built-in anti-pumping device and closing spring charging lever Insulating monobloc Operating mechanism and monobloc fixed to a sturdy metal frame Easy customization with a complete range of accessories Locks to prevent incorrect and hazardous operations

Vmax Standard equipment Mechanical signalling device for CB open/closed Mechanical signalling device for closing spring charged/discharged Opening and closing pushbuttons Mechanical operation counter Built-in lever for manually charging of closing spring Anti-pumping mechanical built-in function 5 + 5 auxiliary contacts Connection terminals and terminal board for auxiliary circuits (for fixed CB) Isolating contacts, cord with connector (plug only), racking-in/out lever (for withdrawable CB)

Vmax Other accessories, on request Shunt tripping release Additional shunt tripping release Shunt closing release Opening solenoid (for self-supplied overcurrent relay ABB PR family) Undervoltage release Electronic time delay (which must be mounted externally in relation to the circuit breaker) for undervoltage release Mechanical override for undervoltage release Opening and closing pushbuttons protection Opening and closing pushbuttons padlock Key-lock in open position 5 extra auxiliary contacts

Vmax Other accessories, on request Motorgear for closing spring charging Signalling contact closing spring charged or signalling contact closing spring discharged Locking magnet in the truck to prevent racking-in with auxiliary circuits disconnected (for withdrawable CB only) Transmitted contacts in the truck for signalling inserted or isolated circuit breaker (for withdrawable CB only) Interlock for fixed circuit breaker which is converted in withdrawable ones by the customer (to prevent racking-out/in with the circuit breaker closed and to prevent closing operation during the translation)

Vmax Compared to VD4, Vmax cannot be fitted with: Transient contact with momentary closing during circuit breaker opening Motorized truck

© ABB Group April 16, 2017 | Slide 14 14