I MMUNOASSAY UTILIZING MAGNETIC BEADS FOR RAPIDVIRUS DETECTION IN THE MICROFLUIDIC FLOW CYTOMETER SYSTEM Sung-Yi Yang, Kang-Yi Lien, Kao-Jean Huang, Huan-Yao.

Slides:



Advertisements
Similar presentations
Chapter 12 - Immunological methods
Advertisements

Dr. Thaweesak Tirawatnapong Chula Medical Research Center (Chula MRC)
MEMS design and Micro-fabrication Lab MML 2-Dimensional SPR Detection System Integrated with Molecular Imprinting Polymer Microarrays Using Microfluidic.
CHAPTER 37 MLAB 1415 HEMATOLOGY JOANNA ELLIS, MLS(ASCP) Optical Light Scatter and Flow Cytometry.
© 2004 Wadsworth – Thomson Learning Immunology Tutorial Introduction & Course outline By: Moh’d J. Al Khatatneh.
OEIC LAB National Cheng Kung University 1 Ching-Ting Lee Institute of Microelectronics, Department of Electrical Engineering, National Cheng Kung University.
Molecular Diagnosis of Infectious Diseases. Why use a molecular test to diagnose an infectious disease? Need an accurate and timely diagnosis Important.
Design of Health Technologies lecture 12 John Canny 10/17/05.
Darryl Benally Team member: ChEng Graduate Student Christopher Killingsworth Supervisor: Professor Randy Bartels.
Real-Time Detection of Biological Pathogens in Urban Environments Laura Barry Hung Phan Gloria See Introduction to Biosensors Presentation 2 - 4/5/2011.
Micro-Fluidic Device for Antigen Discovery
Introduction to Immunoassays
CELL CULTURE AND DIAGNOSTIC VIROLOGY. Since the discovery by Enders (1949) that polioviruses could be cultured tissue, cell culture has become a very.
Altogen Labs, 4020 S Industrial Dr, Suite 130, Austin TX 78744, USA  ELIS A Enzyme-Linked Immunosorbent Assay ELISA.
Professor: Cheng-Hsien, Liu Student: Hao-Ran, Shih ( ) Date: 2010/12/28 Philip N. Duncan, Transon V. Nguyen and Elliot E. Hui Department of Biomedical.
Laboratory Investigation
with an emphasis on DNA microarrays
Antigen antibody reactions
Lec 16 Medical biotechnology Shah Rukh Abbas, PhD
Powerpoint Templates Page 1 Powerpoint Templates Optically induced flow cytometry for continuous microparticle counting and sorting Student: Chin – wei.
Microfluidic System for Automatic Cell Culture Chun-Wei Huang, Song-Bin Huang, Gwo-Bin Lee Department of Engineering Science, National Cheng Kung University,
Enzyme-Linked Immunosorbent Assay [ELISA] BCH 462[practical] Lab#5.
ELISA Assay. What Is It? Enzyme immunoassay (EIA) is a test used to detect and quantify specific antigen-eliciting molecules involved in biological processes,
Class 5 Immuno-assay with magnetic nanoparticle tags Gaster et al Nature Medicine 15:1327 (2009) Basic idea Giant magneto resistance (GMR) Sensor characterization.
Enzyme-Linked Immunosorbent Assay. 2 Introduction ELISA Types Applications Principles.
Development of an Active Micromixer by Dielectrophrosis Particle Manipulating 姓名:黃朝鴻 Chao-hong Huang 班級:奈米一甲 學號:MA11V108.
Sample 2 inlet Buffer inlet Pneumatic micropump The vitamin C filtration Micro-valve outlet Sample 1 inlet MIP morphine sensing electrode Pt Ag Multiple.
Viruses And How They Work. What is a virus?  A non-living particle – reproduces by using a host cell  A VERY small particle – 17 to 300 nanometers long.
2. Basic Immunologic Procedures Part 5 Agglutination
Rapid Bacterial Detection System Fully Automated 4 minute CFU/ml response system SUBC Inc. Rochester MN.
BIOPARTICLE SEPARATION AND MANIPULATION USING DIELECTROPHORESIS Advisor: Yi-Chu Hsu Student: Le Van Cong ( 黎 文 功 ) Date: 11/04/2011.
LAB. DIAGNOSIS OF VIRUSES 5 methods are used for diagnosis in the virology laboratory: 1.Direct microscopy 2.Cultivation of viruses 3.Serology 4. Detection.
Capillary Electrophoresis (CE) PHAR Lecture Objectives By the end of the lecture, students should be able to: 1.Illustrate the CE instrumental.
A SEMINAR ON IMMUNO-DIAGNOSTIC TECHNIQUES
A Wireless Bio-MEMS Sensor for C-Reactive Protein/ECG Detection Based on Nanomechanics Long-Sun Huang and Shey-shi Lu Y. H. Wang* and N. K. Chou* National.
ELISA Nada Mohamed Ahmed , MD, MT (ASCP)i.
Viral Reproduction. Viruses If viruses are non-living, how do they replicate?? They need a host cell! Before a virus can replicate, it must attach to.
Western Blotting. Introduction … Western blotting, also known as immunoblotting or protein blotting, is a technique used to detect the presence of a specific.
Fully-integrated microfluidic chips capable of performing DNA amplification from RNA virus, sample transportation, capillary electrophoresis separation,
Antigen – Antibody Reactions
A MICROFLUIDIC CHIP WITH A NANOSCALE ARRAY FOR ANALYSIS OF VIRUS PARTICLES Kidong Park, Demir Akin, Rashid Bashir Birck Nanotechnology Center, School of.
1 Advisor : Cheng-Hsin Chuang Advisee : Jing-wei Ju Department of Mechanical Engineering & Institute of Nanotechnology, Southern Taiwan University, Tainan,
Integrated Microfluidic Systems for Automatic Glucose Sensing and Insulin Injection 1 Chao-June Huang, 2 Chih-Hao Wang, 3 Yi-Hsin Chen, 3 Tse-Chuan Chou.
MEMS design and Micro-fabrication Lab MML Glass PDMS #2 Choppers PDMS #1 Inlet hole Outlet hole Air inlet A NEW MICROFLUIDIC CHIP FOR FORMATION OF MICRO-DROPLETS.
Dengue fever caused by dengue virus (DENV), a member of Flaviviridae leads to large global disease burden. Detection of immunoglobulin M (IgM) and nucleic.
F LUORESCENCE – A CTIVATED C ELL S ORTING Ana Luisa Caetano Unidade de Citometria de Fluxo Instituto de Medicina Molecular.
Enzyme Linked Immunosorbent Assay
Microfluidic generator of sub-10-micron hydrosomes Zhenghao Ding, Lunjun Liu, Gabriel C. Spalding* Physics Department, Illinois Wesleyan University Abstract.
Telephone    Provider of Global Contract Research Services Accelerating Preclinical Research, Drug Discovery.
© 2004 Wadsworth – Thomson Learning Chapter 19 Diagnostic Immunology.
ICC Immunocytochemistry
A Sandwich DNA Model for Rapid and Sensitive Detection of NSCLC Utilizing the Magnetic Modulation Biosensing System Saar Ashri The Open University Optical.
Lab # 6 ELISA Enzyme – Linked Immuno Sorbent Assay.
Purification Of Proteins.
Roer Eka Pawinanto, Jumril Yunas and Burhanuddin Yeop Majlis
Absorbance: Enzyme Linked Immunosorbent Assays (ELISA)
Electrokinetic Microflows
Flowcytometry.
Enzyme-Linked Immunosorbent Assay ELISA
Synthesis and Evaluation of anti-Nonspecific Binding Coating in Microfluidic Devices for ELISA Bioassays Melissa J. Gelwicks.
LAB. DIAGNOSIS OF VIRUSES
A non-amplification molecular probe approach John Gerdes, Ph. D.
Enzyme-Linked Immunosorbent Assay [ELISA]
Rapid Diagnosis of Dengue virus
Dengue Eva Archer BIO 402.
Microtechnologies for biodetection and diagnostics
Immune System Practice Test
Experimental Systems and Methods
Guarding against disease
Practical of Histopathology
Presentation transcript:

I MMUNOASSAY UTILIZING MAGNETIC BEADS FOR RAPIDVIRUS DETECTION IN THE MICROFLUIDIC FLOW CYTOMETER SYSTEM Sung-Yi Yang, Kang-Yi Lien, Kao-Jean Huang, Huan-Yao Lei, Gwo-Bin Lee National Cheng Kung University, Tainan Taiwan uTAS2007 Professor : Liu, Cheng-Hsien Student : Olof Sterner

A GENDA 1. Introduction 2. Design and Fabrication 3. Results 4. Conclusion 5. Discussion

In this article: Integrated fluid chip for rapid virus identification. Fluid movement is performed by micro circulatory pump driven by airpressure. Magnetic beads covered with specific antibodies. Detection of virus is made through fluorescence by a PMT module. I NTRODUCTION

Current viruses threatening mankind Influenza Hepatitis HIV Dengue fever Ebola Yellow Fever Etc Treatment for viral infections are far behind those of bacterial infections Quick diagnosis crucial I NTRODUCTION

D ESIGN AND F ABRICATION Magnetic beads Covered in specific antibodies toward a certain virus Virus particle functions as antigen and binds specifically to the primary antibody on the magnetic bead. Secondary antibody towards the same virus but targeting a different epitope binds to the virus and carries a fluorescent compound.

D ESIGN AND F ABRICATION Main detection principle 1.Magnetic beads with primary target antibody 2.Target antigen is added (Virus) 3.Secondary fluorescent antibodies is added 4.Fluidic focusing 5.Detection by means of fluorescense

D ESIGN AND F ABRICATION The integrated flow cytometer system A B C Dimensions : 46 mm * 66 mm * 5 mm

D ESIGN AND F ABRICATION A – Virus attachement to magnetic beads. 1.Injection of bio sample and magnetic beads 2.Introduction of sec fluorescent antibodies 3.Mixing with rotary microfluidic pump

D ESIGN AND F ABRICATION Airpressure driven rotary microfluidic pump Biomed Microdevices (2007) 9:545–554 DOI /s

D ESIGN AND F ABRICATION B – Washing and Pretreatment 1.Cu microcoils induced magnetic field attracts magnetic beads 2.Washing with buffer 3.Release of magnetic beads (Flow generated by rotary microfluidic pump) Purification and enrichment of virus samples utilizing magnetic beads on a microfluidic system, Lab Chip, DOI: /b700516d, (2007)

D ESIGN AND F ABRICATION C – Fluid focusing, detection and sorting 1.Sheath flow injection 2.Flow from rotary microfluidic pump for fluid focusing 3.Detection by PMT module 4.Sorting of magnetic beads using feedback signals from PMT 5.Collection of magnetic beads (Flow generated by rotary microfluidic pump

R ESULTS Evaluation of: Pumping rate vs driving frequency of circulatory pump Magnetic field and Temperatur vs Applied current Fluorescence signal amplitude vs time Virus detection limit

R ESULTS Pumping rate vs driving frequence of circulatory pump Magnetic field and Temperature in focusing vs Applied current

R ESULTS Signal amplitude from fluorescence measurement vs time Minimum concentration of 10 4 pfu/ml of Dengue virus could be detected. RT-PCR has detection limit of ~1 pfu/ml Singal to Noise ratio of 30

C ONCLUSION Design for rapid virus diagnosis has been proposed

D ISCUSSION Easy principle, sandwich immunoassay is well documented Gate design is not included in article Sensitivity needs to be enchanced

R EFERENCES Lab Chip, 2007, 7, 868–875, DOI: /b700516d Biomed Microdevices (2007) 9:545–554 DOI /s

TACK !