© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, 1998. Figure 2.1 Three types of potentiometric.

Slides:



Advertisements
Similar presentations
FIGURE 6.1 The electromagnetic radiation spectrum covers everything from very low frequency (VLF) radio to X-rays and beyond. Curtis Johnson Process.
Advertisements

LIGHT SENSORS Sensor Technology Metropolia University Kiia Tammi Jonathan Malangoni.
Chem. 133 – 2/12 Lecture. Announcements Lab Work –Supposed to Cover Set 2 Labs – but I probably won’t cover all and then will give an extra day for period.
Chapter 1. Basic Concepts of Medical Instrumentation Walter H. Olson
Chapter 3. Amplifiers and Signal Processing John G. Webster
Optical sources Lecture 5.
Electronic Devices Eighth Edition Floyd Chapter 4.
Basic Sensors and Principles
Variable Capacitance Transducers The Capacitance of a two plate capacitor is given by A – Overlapping Area x – Gap width k – Dielectric constant Permitivity.
Spring 2005ISAT 253 Transducers and Sensors I Friday, March 18, 2005.
© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Ch 02 Basic Sensors and Principles.
Semiconductor Light Detectors ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
1 Chapter 5 Sensors and Detectors A detector is typically the first stage of a communication system. Noise in this stage may have significant effects on.
Chapter 3. Amplifiers and Signal Processing John G. Webster
Medical Instrumentation Application and Design, 4th Edition
Chapter 1. Basic Concepts of Medical Instrumentation Walter H. Olson
Temperature Sensors.
ZENER DIODE / BREAKDOWN DIODE
Characteristics, Structures, and Applications.  Description of LED and Infrared LED  Schematic Symbol  Structure  Function and Characteristics  Application.
EKT314/4 Electronic Instrumentation
Medical Instrumentation Application and Design, 4th Edition
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Photon detection Visible or near-visible wavelengths
What ARE all those little things anyway?
3/26/2003BAE of 10 Application of photodiodes A brief overview.
Electronic Devices and Circuit Theory
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
Basic Electronic Components. Crystals Equivalent Circuit to Crystal.
Chapter 1: Semiconductor Diodes. Copyright ©2009 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Electronic Devices.
Biomedical Electrodes, Sensors, and Transducers
Photoemissive Light Detectors ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
OBJECTIVE Without reference, identify at least four out of six principles pertaining to the application of transducers related to patient care.
Copyright ©2011 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Introduction to Engineering Experimentation, Third.
Chapter 1: Semiconductor Diodes. Copyright ©2009 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Electronic Devices.
Colorimeters or photometers
Title Light Detectors. Characteristics  Sensitivity  Accuracy  Spectral Relative Response(R( ))  Absolute Sensitivity(S( ))  Signal-to-noise ratio.
Diodes and Diode Applications Topics Covered in Chapter : Semiconductor Materials 27-2: The PN Junction Diode 27-3: Volt-Ampere Characteristic Curve.
Medical Instrumentation II. Resistive Sensor  Strain gage : changes in L & ρ  Force sensing resistor : changes in A  Thermistor : changes in L  Potentiometer.
Optoelectronics.
Perceptible output Output display Control And feedback Signal
BASIC MECHANICAL SENSORS AND SENSOR PRINCIPLES. Definitions Transducer: a device that converts one form of energy into another. Sensor: a device that.
Temperature Measurements Principles Measuring Devices Applications بِسْـــــمِ اللهِ الرَّحْمَنِ الرَّحيـــــِمِ
Robert Boylestad Digital Electronics Copyright ©2002 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Chapter 1: Semiconductor.
8. Photo Electric Transducers:
Infrared IR Sensor Circuit Diagram and Working Principle.
© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 3.1 Op-amp equivalent circuit.
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
ELECTRONIC INSTRUMENTATION
CHAPTER 5 DC AND AC BRIDGES.
College Name : Shree Swami Atmanand Saraswati Institute Of Technology(SSASIT)(076) Year : 2 nd year(3 rd sem) EC-2015 Subject Name : Electronic Devices.
Signal Conditioning Elements (SCE). 6/13/2016Measurement & Transducers2 1. Voltage dividers Example :Potentiometer circuit.
Additional information on Passive Probes (10x) Take note that the scope’s input capacitance, C in must falls within the probe’s compensation range For.
EKT 451 CHAPTER 6 Sensor & Transducers.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
BME 301: Biomedical Sensors Lecture Note 2: Sensor Characteristics, Transducer Systems, Displacement and Temperature Sensors BME 301 Lecture Note 2 - Ali.
Physics of Semiconductor Devices
Application of photodiodes
MECH 373 Instrumentation and Measurements
Physics of Semiconductor Devices Mr. Zeeshan Ali, Asst. Professor
MECH 373 Instrumentation and Measurements
Chapter 1: Semiconductor Diodes
Chapter 3. Components of Optical Instruments
Basic Sensors and Principles
Chem. 133 – 2/9 Lecture.
Figure 2.1 Three types of potentiometric devices for measuring displacements (a) Translational. (b) Single-turn). (c) Multi-turn. (From Measurement Systems:
Ch 02 Basic Sensors and Principles
On Subject Instrumentation Electrical Engg 4th Sem
Prepared by Dr. Mohamed Ahmed Awad
ECE699 – 004 Sensor Device Technology
Semiconductor Diodes Chapter 1 Boylestad Electronic Devices and Circuit Theory.
Presentation transcript:

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.1 Three types of potentiometric devices for measuring displacements (a) Translational. (b) Single-turn). (c) Multi-turn. (From Measurement Systems: Application and Design, by E. O. Doebelin. Copyright  1990 by McGraw-Hill, Inc. Used with permission of McGraw-Hill Book Co.)

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.2 (a) Unbonded strain-gage pressure sensor. The diaphragm is directly coupled by an armature to an unbonded strain-gage system. With increasing pressure, the strain on gage pair B and C is increased, while that on gage pair A and D is decreased. (b) Wheatstone bridge with four active elements. R 1 = A, R 2 = B, R 3 = D, and R 4 = C when the unbonded strain gage is connected for translation motion. Resistor R y and potentiometer R x are used to initially balance the bridge. v i is the applied voltage and  v 0 is the output voltage on a voltmeter or similar device with an internal resistance of R i. Armature Strain-gage wires A D (a) C B Diaphragm (b) c b d a R4R4  o o ii R3R3 R2R2 RyRy RiRi RxRx R1R1

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.3 Typical bonded strain-gage units (a) Resistance-wire type. (b) Foil type. (c) Helical-wire type. Arrows above units show direction of maximal sensitivity to strain.[Parts (a) and (b) are modified from Instrumentation in Scientific Research, by K. S. Lion. Copyright  1959 by McGraw-Hill, Inc. Used with permission of McGraw-Hill Book Co.]

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.4 Typical semiconductor strain-gage units (a) Unbonded, uniformly doped. (b) Diffused p- type gage. (c) Integrated pressure sensor. (d) Integrated cantilever- beam force sensor. (From Transducers for Biomedical Measurements: Application and Design, by R. S. C. Cobbold. Copyright  1974, John Wiley and Sons, Inc. Used by permission of John Wiley and Sons, Inc.)

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.5 Mercury-in-rubber strain-gage plethysmography (a) Four-lead gage applied to human calf. (b) Bridge output for venous-occlusion plethysmography. (c) Bridge output for arterial-pulse plethysmography. [Part (a) is based on D. E. Hokanson, D. S. Sumner, and D. E. Strandness, Jr., "An electrically calibrated plethysmograph for direct measurement of limb blood flow." 1975, BME-22, 25-29; used with permission of IEEE Trans. Biomed. Eng., 1975, New York.]

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.6 Inductive displacement sensors (a) Self-inductance. (b) Mutual inductance. (c) Differential transformer. c d c c d (a)(b)(c) c d aa a b e d c b b d

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.7 (a) As x moves through the null position, the phase changes 180 , while the magnitude of v o is proportional to the magnitude of x. (b) An ordinary rectifier-demodulator cannot distinguish between (a) and (b), so a phase-sensitive demodulator is required.

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.8 Capacitance sensor for measuring dynamic displacement changes

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.9 (a) Equivalent circuit of piezoelectric sensor, where R s = sensor leakage resistance, C s = sensor capacitance, C c = cable capacitance, C a = amplifier input capacitance, R a = amplifier input resistance, and q = charge generator. (b) Modified equivalent circuit with current generator replacing charge generator. (From Measurement Systems: Application and Design, by E. O. Doebelin. Copyright  1990 by McGraw-Hill, Inc. Used with permission of McGraw-Hill Book Co.) (b) R = R a R s /(R a + R s ) » R a C = C s + C c + C a Charge generator i s = Kdx/dt isis C R iCiC iRiR + - i a = 0 oo Amplifier (a) Charge generator q = Kx RsRs CsCs CcCc CaCa + i Amplifier = 0 oo - Amplifier Cable e Crystal x

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.10 Sensor response to a step displacement (From Measurement Systems: Application and Design, by E. O. Doebelin. Copyright  1990 by McGraw-Hill, Inc. Used with permission of McGraw-Hill Book Co.)

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.11 (a) High-frequency circuit model for piezoelectric senor. R s is the sensor leakage resistance and C s the capacitance. L m, C m, and R m represent the mechanical system. (b) Piezoelectric sensor frequency response. (From Transducers for Biomedical Measurements: Application and Design, by R. S. C. Cobbold. Copyright  1974, John Wiley and Sons, Inc. Used by permission of John Wiley and Sons, Inc.) Output voltage Input force (b) Mechanical resonance Frequency (a) RtRt CsCs CmCm LmLm RmRm f c Usable range

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.12 Thermocouple circuits (a) Peltier emf. (b) Law of homogeneous circuits. (c) Law of intermediate metals. (d) Law of intermediate temperatures.

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.13 (a) Typical thermistor zero-power resistance ratio-temperature characteristics for various materials. (b) Thermistor voltage-versus-current characteristic for a thermistor in air and water. The diagonal lines with a positive slope give linear resistance values and show the degree of thermistor linearity at low cerrents. The intersection of the thermistor curves and the diagonal lines with the negative slope give the device power dissipation. Point A is the maximal current value for no appreciable self-heat. Point B is the peak voltage. Point C is the maximal safe continuous current in air. [Part (b) is from Thermistor Manual, EMC-6,  1974, Fenwal Electronics, Framinham, MA; used by permission.]  Temperature, ° C Water Air 0.1 mW 1 mW 10 mW 100 mW 1 W 100  1 k  10 k  100 k  1 M  A C B Current, mA (a) (b) Resistance ratio, R/R 25º C

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.14 (a) Spectral radiant emittance versus wavelength for a blackbody at 300 K on the left vertical axis; percentage of total energy on the right vertical axis. (b) Spectral transmission for a number of optical materials. (c) Spectral sensitivity of photon and thermal detectors. [Part (a) is from Transducers for Biomedical Measurements: Principles and Applications, by R. S. C. Cobbold. Copyright  1974, John Wiley and Sons, Inc. Reprinted by permission of John Wiley and Sons, Inc. Parts (b) and (c) are from Measurement Systems: Application and Design, by E. O. Doebelin. Copyright  1990 by McGraw-Hill, Inc. Used with permission of McGraw-Hill Book Co.] 123 Wavelength,  m (a) (b) (c) Wavelength,  m 1520 T = 300 K m = 9.66  m % Fused silica Sapphire Arsenic trisulfide Thallium bromide iodine Indium antimonide (InSb) (photovoltaic) Lead sulfide (PbS) All thermal detectors Wavelength,  m % Total power Spectral radient emittance, W-cm -2 ·mm -1

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.15 Stationary chopped-beam radiation thermometer (From Transducers for Biomedical Measurements: Principles and Applications, by R. S. C. Cobbold. Copyright  1974, John Wiley and Sons, Inc. Reprinted by permission of John Wiley and sons. Inc.)

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.16 Details of the fiber/sensor arrangement for the GaAs semiconductor temperature probe.

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.17 (a) General block diagram of an optical instrument. (b) Highest efficiency is obtained by using an intense lamp, lenses to gather and focus the light on the sample in the cuvette, and a sensitive detector. (c) Solid-state lamps and detectors may simplify the system.

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.18 Spectral characteristics of sources, filters, detectors, and combinations thereof (a) Light sources, Tungsten (W) at 3000 K has a broad spectral output. At 2000 K, output is lower at all wavelengths and peak output shifts to longer wavelengths. Light-emitting diodes yield a narrow spectral output with GaAs in the infrared, GaP in the red, and GaAsP in the green. Monochromatic outputs from common lasers are shown by dashed lines: Ar, 515 nm; HeNe, 633 nm; ruby, 693 nm; Nd, 1064 nm; CO 2 (notshown), nm. (b) Filters. A Corning 5-65 glass filter passes a blue wavelength band. A Kodak 87 gelatin filter passes infrared and blocks visible wavelengths. Germanium lenses pass long wavelengths that cannot be passed by glass. Hemoglobin Hb and oxyhemoglobin HbO pass equally at 805 nm and have maximal difference at 660 nm. (c) Detectors. The S4 response is a typical phototube response. The eye has a relatively narrow response, with colors indicated by VBGYOR. CdS plus a filter has a response that closely matches that of the eye. Si p-n junctions are widely used. PbS is a sensitive infrared detector. InSb is useful in far infrared. Note: These are only relative responses. Peak responses of different detectors differ by 107. (d) Combination. Indicated curves from (a), (b), and (c) are multiplied at each wavelength to yield (d), which shows how well source, filter, and detector are matched. (e) Photon energy: If it is less than 1 eV, it is too weak to cause current flow in Si p-n junctions.

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.19 Forward characteristics for p-n junctions. Ordinary silicon diodes have a band gap of 1.1 eV and are inefficient radiators in the near-infrared. GaAs has a band gap of 1.44 eV and radiates at 900 nm. GaP has a band gap of 2.26 eV and radiates at 700 nm.

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.20 Fiber optics. The solid line shows refraction of rays that escape through the wall of the fiber. The dashed line shows total internal reflection within a fiber. Air n = 1.0 Coating Fiber n1n1 33 44 11 22  ic n2n2

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.21 Photomultiplier An incoming photon strikes the photocathode and liberates an electron. This electron is accelerated toward the first dynode, which is 100 V more positive than the cathode. The impact liberates several electrons by secondary emission. They are accelerated toward the second dynode, which is 100 V more positive than the first dynode, This electron multiplication continues until it reaches the anode, where currents of about 1  A flow through R L.

© From J. G. Webster (ed.), Medical instrumentation: application and design. 3 rd ed. New York: John Wiley & Sons, Figure 2.22 Voltage-current characteristics of irradiated silicon p-n junction. For 0 irradiance, both forward and reverse characteristics are normal. For 1 mW/cm 2, open-circuit voltage is 600  V and short-circuit current is 8  A.