Ozone system integration Your Logo Here Joe Mendez, Director Courtesy of Piper Environmental Group, Inc Joe Mendez, Director Courtesy of Piper Environmental.

Slides:



Advertisements
Similar presentations
Dairy Surface Water Disinfection - Case Study -. Dairy Farm - Continental, OH 600 head of dairy cattle Milked 3 times/day Facility Background.
Advertisements

Not Just for Bottled Water Any More!
HVAC523 Heat Sources.
What is Quickpure Technology and why is it the only economical technology available anywhere in the world that works for small ozone systems?
Inert Gas Purification Systems Why do we need them??? Many of the materials used in research and development today are extremely air sensitive, and can.
Copyright. Prozone Pool Products. phone: fax: Corona Discharge and Vacuum Ultraviolet Ozone Systems.
ClearWater Tech LLC EcoTex - Advanced Laundry Oxidation Systems Ozone Laundry Methodology.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
Please click on our logo or any link in this presentation to be redirected to our website & . Thank You! 17A Marlen Drive  H amilton, NJ 
Interest Approach Identify the major systems of an engine.
Why Use Ozone  To improve water quality (disinfection)  To improve swimmer comfort  To reduce maintenance costs  To reduce chemical costs  To improve.
PLANT DESIGN (I) Prof. Dr. Hasan farag.
SAFETY, TOOLS & EQUIPMENT, SHOP PRACTICES
Ozone Applications By Ed Knueve ClearWater Tech, LLC.
Engine Systems and Components
Treatment Plant Ozone Retrofit Program California Unified Program 8 th Annual Training Conference February 8, 2006 Presented by: Paul G. Beswick Metropolitan.
Drug Delivery & Tissue Engineering Laboratory
Water Quality Management. Water Filtration (Mechanical)
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Innovative system for Haemodialysis Equipment Disinfection
Part II: Mass Transfer of O 3 in Water: Fundamentals & Applications L aboratory of P hysical and A nalytical C hemistry REWARD H. Vankerckhoven.
Chapter 3: Bioreactor Design
©2005 Armstrong International, Inc. Open and Closed Systems.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Fuel Evaporation in Ports of SI Engines P M V Subbarao Professor Mechanical Engineering Department Measure of Useful Fuel …..
Introducing the WaterMagnet®
French Fry Fuel Sponsored by J.R. Simplot, Co.
Marine Engine Systems Merchant Marine Training Centre.
POWER PLANT.
STEAM HEATING.
CD Ozone (oxidation) Ozone is produced with a high voltage electrical discharge called a “corona discharge” or “CD”. The idea is to actually create a small,
Air Compressors.
Oil Heat Properties of Fuel Oil.
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
Lease Automatic Custody Transfer
CHAPTER 13.7 Exhaust Gas Re-Circulation Valve
C ONVEYORS By SidraJabeen Department of Chemical Engineering, University of Engineering & Technology Lahore.
PURECHLOR – System, Service, Reagents & BOOM. Chlorine dioxide What is Chlorine Dioxide (ClO 2 )? A powerful biocide Consists of 1 atom of Chlorine, 2.
Water Handling Operations
Next Generation OBIGGS: Developments at Phyre Technologies
PLATFORM UTILITIES PAB 2073 Reference: PCSB/PMO document.
1 Combustion Oil Fired Equipment. 2 OIL Combustion of oil fired equipment has the same basics of gas. Remember, Oil is a liquid and this must be converted.
HYDRAULICS & PNEUMATICS
Lecture Objectives: Continue with power generation Learn basics about boilers and furnaces.
Mazzei Injector Company, LLC
Pneumatic and hydraulic actuation systems
Clark Reliance Corporation Strongsville, OH. Fuel Gas Treatment.
The Importance of Distribution. Manifold Position And Vapor Trail.
CHAPTER 5: Mass and Energy Analysis of Control Volumes
HPLC – High Performance Liquid Chromatography
1 III. Water Treatment Technologies Topic III. 6. Water Disinfection: Reagents, Processes and Equipment Reagents §Chlorine and Cl-compounds l Very effective.
Welcome to the Presentation of Plasma Based HNO3 Manufacturing Plant.
Flux Cored Arc Welding (FCAW)
Centrifugal Compressor
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
We use at our unit polymeric membranes to separate hydrocarbons without heating feedstock to the boiling point, and without using fired heaters.
Hybritec Refrigerated/Blower Purge Dryers (Combination Dryer)
Treatment Options for Rainwater Harvesting Systems For more information go to:
BSB Biomanufacturing CHAPTER 2 Process Plant Design – Part III
Natural Gas Production Chapter 5 Dehydration of Natural Gas
UNIT INJECTOR SYSTEM.
Introducing the WaterMagnet®
Matt Bower DWQR Risk Assessment Training 2018
Large Air Systems – Sales Training
Presentation transcript:

Ozone system integration Your Logo Here Joe Mendez, Director Courtesy of Piper Environmental Group, Inc Joe Mendez, Director Courtesy of Piper Environmental Group, Inc

Overview of Class n Provide you with the basic concepts of ozone system integration. n You will not be an “expert”, but you will understand the basic components and their integration.

Component Descriptions n Feedstock gas n Ozone Generator n Injection system n Contact vessel n Degas n Destruct n Instrumentation and Controls

140 GPM of Well Water Fe =.58ppm Mn =.12ppm System Pump 30 gpm Mazzei Injector with By pass Ozone Contact Tank 16 gal. capacity GDT Corp. DS – 100 WM Degasser Graduated Media Filter Armstrong AV-3 Gas vent Demister Ozone Destruct Unit ClearWater Tech CD4040 HO Ozone Generator Finished Water Fe < 0.1 ppm Mn ~ 0.05 ppm 110 gal By pass Flow rate ORP Controller Cobb Water District - System Diagram

Feedstock gas n Air. –Must be clean and very dry. Typical dew point of F –At a dew point of F about 50% of the output of the ozone generator will be lost –Will produce Nox which in the presence of moisture will produce Nitric Acid which corrodes Stainless Steel –Source of compressed air must be oil vapor free.

Feedstock gas - continued n Oxygen. - Minimum purity 90% oxygen with a dew point of F –Bottled oxygen - not recommended, except for short, less than one day, tests. –Liquid oxygen - not recommended for residential. OK in commercial and industrial use for short term demonstrations and pilot studies. –Oxygen generators - Will typically pay for themselves in less than 18 months. Require about 10 to 12 scfm of compressed air per scfm of oxygen. Low pressure systems - less than 10 psig - small ozone generators - AIRSEP and SEQUAL. High pressure systems - up to 100 psig - large ozone generators - AIRSEP, OGSI, OXAIR, etc. – Be aware of fire problems specially in large units

Ozone generators n UV - not suitable for water treatment. Output is about.1% ozone by weight. Used in Spas. n Corona discharge - suitable for water treatment. Output range of 1 to 18% ozone by weight. n Output, Concentration and Flow. What is their relationship? –(G/hr) X (0.0755) / ( % conc.) = Nm 3 /hr

Ozone generators - continued n Variants of CD ozone generators. –Frequency - Low frequency (60 Hz), Medium frequency (1000 Hz) and High frequency (10,000Hz) –Cooling - Air or water cooled –Operating pressure - Vacuum, 10 to 15 psig and20 to 30 psig –Size - Small ( 10 to 150 PPD) and large (>150 PPD to one ton per day) –Feedstock gas - Air or oxygen

Ozone injection n Bubbling or direct injection –Low mass transfer efficiency –Takes a lot of real estate –Subject to water back-flowing into generator n Eduction - Venturi effect (Mazzei injectors) –High mass transfer efficiency –Compact foot print –Subject to water back-flowing into generator

Contact vessel n A tank or length of pipe designed to allow the ozone gas and the water to mix for about 30 seconds to 1 minute. It improves mass transfer of the ozone. n Residential - Fiberglass tank in the 20 to 40 gallons range. n Commercial/Industrial stainless steel tank in various size ranges.

Degas system n Residential - Typically a stainless steel vent valve on top of the contact vessel. Allows the un-dissolved gasses, including excess ozone to be vented from the top of the tank. n Commercial / Industrial - Typically an additional stainless steel vessel that imparts centrifugal force on the water and separates it from the un-dissolved gasses. They in turn are vented through a stainless steel vent valve. n GDT System is a patented separator device. Due to cost, it is not used in a residential or light commercial environment.

Destruct system n The purpose of a destruct system is to destroy any excess ozone in the off gas. Ozone is a Toxic Gas and an EPA listed pollutant. It should not be vented into the atmosphere. n Variants of ozone destruct units – Temperature only - Expensive to operate. Requires a minimum of F for quick (<1 sec.) destruction. – Catalyst only - Inexpensive to operate. Requires that gas flow be de-misted to remove excess moisture. Moisture will destroy the catalyst and Sulfur will poison it. – Combination units - Most widely used. Uses a small heater to dry the gas stream and catalyst to complete the destruction.

Instrumentation and controls n Instrumentation -The purpose of instrumentation is to allow the user or operator to be aware of the operating conditions. Instrumentation can be hand held or fixed. It can also be chemical or electronic. n Controls - The purpose of controls is to allow for the automatic control of the ozone generator and associated equipment.

Instrumentation and controls - continued n Dissolved ozone - Colorometric - DPD Chlorine or Indigo Blue. About $75 in cost. Readings up to 2.3 ppm. Used to indicate spot readings. n Dissolved ozone - Electronic - wet cell without reagents. About $3,000 in cost. Readings up to 15 ppm. Typically used to indicate and to control ozone generator output. Most typically used in industrial and high end commercial applications. n ORP - Oxidation Reduction Potential. Less than $1,000 in cost. It is used as both an instrument and a control. It can control ozone generator output. Readings are expressed in mV (millivolts). European standards declare that water is sanitized after it reaches a reading of 750 mV of ORP. Most typically used in commercial and high end residential applications.

Methods of integration n Factory systems. The system is integrated for you and it is delivered as a complete package. Lends itself to small systems under 20 gpm. Typically used in the residential and light end commercial environment. n Self integrated systems. This requires a much higher level of expertise. It requires knowledge of pumps, injection systems, contacting, degassing and controls. It requires the ability to assemble the entire system from various pieces and vendors. The amount of capital required for this level also increases dramatically, with the size of the ozone generator. An integrator is usually a “Distributor”, and they take ownership of the equipment, so the integrator must have the ability to finance the equipment until paid by the end user.

Questions?