1 Gas Chromatography Lecture 39. 2 a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection.

Slides:



Advertisements
Similar presentations
Gas Chromatography Introduction 1.) Gas Chromatography
Advertisements

GAS CHROMATOGRAPHY CHAPTER 21.
Gas Chromatography Lecture 36.
Gas Chromatography Vaporization of sample Gas-solid
Lecture 8b Gas Chromatography.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
Lab Methods Day June 25, 2014 Gas Chromatography
Gas Chromatography in the detection of Volatile Organic Compounds.
Flame Ionization Detector Most common detector Carbon atoms (C-C bonds) are burned in a hydrogen flame. A small portion of carbon atoms are ionized (about.
Experiment 6 Simple and Fractional Distillation.
4. Advances in Gas Chromatography. Topics covered capillary columns headspace analysis solid phase micro-extraction.
In carbon-13 NMR, what do the number of peaks represent?
Gas Chromatography.
Chapter 27 Gas Chromatography
1 Chapter 24 GC Gas Chromatography. 2 GC Mechanism of separation is primarily volatility. Difference in boiling point, vapor pressure etc. What controls.
Capillary Columns Nicholas H. Snow Department of Chemistry, Seton Hall University, 400 South Orange Avenue, South Orange, NJ 07079
Gas chromatography is used in many research labs, industrial labs (quality control), forensic (arson and drug analysis, toxicology, etc.), environmental.
Gas Chromatography.
Chromatography Chapter 4.
GC Detectors Ideal Detector Characteristics: 1. Universal Response
Gas Liquid Chromatography
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Effect of Packing Particle Size on Plate Height. Resolution between 2 adjacent peaks.
LECTURE 4: CHROMATOGRAPHY Content: - Chromatographic separation - classifying analytical separations; column chromatography, planar chromatography - gas.
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
Gas Chromatography A separation science.... What is Chromatography? The separation of a mixture of two or more compounds or ions by distribution between.
PLOT Columns P orous L ayer O pen T ubular Porous layer open tubular (PLOT) columns are defined as capillary columns where the inner surface is coated.
Chapter 33 Supercritical-Fluid Chromatography
animation.php.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Gas Chromatography A separation science.... What is Chromatography? The separation of a mixture of two or more compounds or ions by distribution between.
Gas Chromatography: Detectors. The Ideal Detector n Adequate sensitivity - range 10 ^- 18 to 10^-15 g analyte/s n good stability and reproducibility n.
Gas Chromatography Lecture 38.
5.2 Notes Organic Analysis Pg Three chromatographic processes are used 1. Gas 2. High-Performance Liquid Chromatography 3. Thin-layer chromatography.
Capillary Electrophoresis (CE) PHAR Lecture Objectives By the end of the lecture, students should be able to: 1.Illustrate the CE instrumental.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Analytical Separations
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
Created with MindGenius Business 2005® Gas Chromatography Gas Chromatography From Harris, Quantitative Chemical Analysis, 6e, Chapter 24.
1 HPLC Lecture Displacement pumps Displacement pumps, on the other hand, is composed of a one directional motor driven plunger that pushes the mobile.
5.2 Notes Organic Analysis Pg Objectives List and describe the parts of a gas chromatography Explain the difference between thin- layer chromatography.
Lecture 4a Gas Chromatography.
GAS CHROMATOGRAPHY In gas chromatography (GC), the sample is injected onto the head of a chromatographic column and immediately vaporized. The components.
GAS LIQUID CHROMATOGRAPHY Principles Partition of molecules between gas (mobile phase) and liquid (stationary phase).
Ch 21 – Principles of Chromatography and Mass Spectrometry Ch 22 – Gas and Liquid Chromatography.
Atomic Absorption Spectroscopy
Prof. aza Basic gas chromatography prof. aza Department of Pharmacy, Andalas University STIFI Perintis, Padang STIFAR, Pekan Baru STIFI Bhakti Pertiwi,
Chapter 32 Gas Chromatography. In gas chromatography, the components of a vaporized sample are separated by being distributed between a mobile gaseous.
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
K V GOPINATH M Pharm PhD,CPhT Tirumala Tirupati Devasthanams TIRUPATI GAS CHROMATOGRAPHY.
Thermal Conductivity Detector
M.PRASAD NAIDU Msc Medical Biochemistry, Ph.D Research scholar.
Experiments in Analytical Chemistry
Gas Chromatography Chap 27 Types: Gas-solid chromatography (GSC)
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
An analytical instrumentation process
Chapter 27 Gas Chromatography
Gas Chromatography.
Gas chromatography Dr. Gangadhar Chatterjee MBBS, MD (3rd year PGT)
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
VAPOUR PHASE CHROMATOGRAPHY
Principle of separation of different components:
Gas Chromatography.
32A-4 Chromatographic Detectors
GAS CHROMATOGRAPHY.
Presentation transcript:

1 Gas Chromatography Lecture 39

2 a. Thermal Conductivity Detector (TCD) This is a nondestructive detector which is used for the separation and collection of solutes to further perform some other experiments on each purely separated component. The heart of the detector is a heated filament which is cooled by helium carrier gas. Any solute passes across the filament will not cool it as much as helium does because helium has the highest thermal conductivity. This results in an increase in the temperature of the filament which is related to concentration. The detector is simple, nondestructive, and universal but is not very sensitive and is flow rate sensitive.

3

4

5 Note that gases should always be flowing through the detector including just before, and few minutes after, the operation of the detector. Otherwise, the filament will melt. Also, keep away any oxygen since oxygen will oxidize the filament and results in its destruction. Remember that TCD characteristics include: 1.Rugged 2.Wide dynamic range (10 5 ) 3.Nondestructive 4.Insensitive (10 -8 g/s) 5.Flow rate sensitive

6 b. Flame Ionization Detector (FID) This is one of the most sensitive and reliable destructive detectors. Separate two gas cylinders, one for fuel and the other for O 2 or air are used in the ignition of the flame of the FID. The fuel is usually hydrogen gas. The flow rate of air and hydrogen should be carefully adjusted in order to successfully ignite the flame.

7

8

9 The FID detector is a mass sensitive detector where solutes are ionized in the flame and electrons emitted are attracted by a positive electrode, where a current is obtained. The FID detector is not responsive to air, water, carbon disulfide. This is an extremely important advantage where volatile solutes present in water matrix can be easily analyzed without any pretreatment.

10 Remember that FID characteristics include: Rugged Sensitive ( g/s) Wide dynamic range (10 7 ) Signal depends on number of carbon atoms in organic analytes which is referred to as mass sensitive rather than concentration sensitive Weakly sensitive to carbonyl, amine, alcohol, amine groups Not sensitive to non-combustibles – H 2 O, CO 2, SO 2, NO x Destructive

11 Electron Capture Detector (ECD) This detector exhibits high intensity for halogen containing compounds and thus has found wide applications in the detection of pesticides and polychlorinated biphenyls. The mechanism of sensing relies on the fact that electronegative atoms, like halogens, will capture electrons from a b emitter (usually 63 Ni). In absence of halogenated compounds, a high current signal will be recorded due to high ionization of the carrier gas, which is N 2, while in presence of halogenated compounds the signal will decrease due to lower ionization.

12

13 Remember the following facts about ECD: 1. Electrons from a b-source ionize the carrier gas (nitrogen) 2. Organic molecules containing electronegative atoms capture electrons and decrease current 3. Simple and reliable 4. Sensitive ( g/s) to electronegative groups (halogens) 5. Largely non-destructive 6. Insensitive to amines, alcohols and hydrocarbons 7. Limited dynamic range (10 2 ) 8. Mass sensitive detector

14 Gas Chromatographic Columns and Stationary Phases Packed Columns These columns are fabricated from glass, stainless steel, copper, or other suitable tubes. Stainless steel is the most common tubing used with internal diameters from 1-4 mm. The column is packed with finely divided particles (<  m diameter), which is coated with stationary phase. However, glass tubes are also used for large- scale separations.

15 Several types of tubing were used ranging from copper, stainless steel, aluminum and glass. Stainless steel is the most widely used because it is most inert and easy to work with. The column diameters currently in use are ordinarily 1/16" to 1/4" 0.D. Columns exceeding 1/8" are usually used for preparative work while the 1/8" or narrower columns have excellent working properties and yield excellent results in the analytical range. These find excellent and wide use because of easy packing and good routine separation characteristics. Column length can be from few feet for packed columns to more than 100 ft for capillary columns.

16 Capillary/Open Tubular Open tubular or capillary columns are finding broad applications. These are mainly of two types: Wall-coated open tubular (WCOT) <1  m thick liquid coating on inside of silica tube Support-coated open tubular (SCOT) 30  m thick coating of liquid coated support on inside of silica tube These are used for fast and efficient separations but are good only for small samples. The most frequently used capillary column, nowadays, is the fused silica open tubular column (FSOT), which is a WCOT column.

17 The external surface of the fused silica columns is coated with a polyimide film to increase their strength. The most frequently used internal diameters occur in the range from micrometer. However, other larger diameters are known where a 530 micrometer fused silica open tubular column was recently made and is called a megapore column, to distinguish it from other capillary columns. Megapore columns tolerate a larger sample size.

18

19

20

21

22 It should be noted that since capillary columns are not packed with any solid support, but rather a very thin film of stationary phase which adheres to the internal surface of the tubing, the A term in the van Deemter equation which stands for multiple path effects is zero and the equation for capillary columns becomes H = B/V + CV

23 Capillary columns advantages compared to packed columns 1.higher resolution 2.shorter analysis times 3.greater sensitivity Capillary columns disadvantage compared to packed columns 1.smaller sample capacity 2.Need better experience

24 Solid Support Materials The solid support should ideally have the following properties: 1.Large surface area (at least 1 m 2 /g) 2.Has a good mechanical stability 3.Thermally stable 4.Inert surface in order to simplify retention behavior and prevent solute adsorption 5.Has a particle size in the range from  m

25 Selection of Stationary Phases General properties of a good liquid stationary phase are easy to guess where inertness towards solutes is essential. Very low volatility liquids that have good absolute and differential solubilities for analytes are required for successful separations. An additional factor that influences the performance of a stationary phase is its thermal stability where a stationary phase should be thermally stable in order to obtain reproducible results. Nonvolatile liquids assure minimum bleeding of the stationary phase

26 Weight of liquid stationary phase * 100% % Loading = Increasing percent loading would allow for increased sample capacity and cover any active sites on the solid support. These two advantages are very important, however increasing the thickness of stationary phase will affect the C term in the van Deemter equation by increasing H S, and therefore H t. Weight of stationary phase plus solid support

27 Generally, the film thickness primarily affects the retention character and the sample capacity of a column. Thick films are used with highly volatile analytes, because such films retain solutes for a longer time and thus provide a greater time for separation to take place. Thin films are useful for separating species of low volatility in a reasonable time. On the other hand, a thicker film can tolerate a larger sample size. Film thicknesses in the range from 0.1 – 5  m are common.