Recent Advances in IOP measurements

Slides:



Advertisements
Similar presentations
A Wireless, Implantable Intra- Ocular Pressure Sensor for the Management of Glaucoma Gabriel Simon, M.D. Ph.D. Sept 16, 2008 ESCRS.
Advertisements

Scanning Tonometer for Eye Pressure (STEP™) Problem Measurement of eye pressure by Goldmann applanation tonometry is a technique first embodied in the.
Goldmann Tonometer.
Thermoforming Process
Biomechanical Properties of the Cornea in Normal- Tension Glaucoma Authors: Leonidas Traipe Ines Cayuqueo Fabiola Cerfogli Claudia Goya Allister Gibbons.
Transpalpebral Tonometry H.v.Below, O.Riemer Common practice for ambulant and stationary ophthalmology Grimma/Sachsen.
Canadian Ophthalmological Society Evidence-based Clinical Practice Guidelines for the Management of Glaucoma in the Adult Eye.
Schiotz tonometer.
Statement of Commercial Interest: RDJ: None DRH: honoraria from Reichert for educational lectures on corneal biomechanics Multiple studies have shown ex.
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Applanation tonometry:
Comparison between Dynamic contour tonometry, Goldmann applanation tonometry and Ehlers-corrected Goldmann applanation tonometry in eyes after Laser In.
Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.
Biomechanical Properties of Healthy and Keratoconic Corneas Evaluated Using an Ultra-High-Speed Scheimpflug Camera nznec Department of Ophthalmology University.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Level Sensors.
SENSORS AND TRANSDUCERS
SEI IOP and its correlations in a population based study in Central India. The Central India Eye and Medical Study. Krishna Bhojwani, Vinay Nangia, Jost.
The Canadian Association of Optometrists
CR The Glaucoma Tonometer. What sets it apart? Reichert’s 7CR Auto Tonometer + Corneal Response Technology takes corneal biomechanical properties into.
INTRAOCULAR PRESSURE LECTURE
OPEN ANGLE GLAUCOMA Frank J. Weinstock, MD, FACS Professor of Ophthalmology- NEOUCOM Canton, Ohio USA.
Comparison of the Diaton Transpalpebral Tonometer Versus Goldmann Applanation R. S. Davidson 1 ; N. Faberowski 2 ; R. J. Noecker 3 ; M. Y. Kahook 1 1.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Methods of measuring intra ocular pressure. What is intra ocular pressure ? Definition Intra ocular pressure refers to the pressure exerted by the intra.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
Oliver Findl 1,2, Nino Hirnschall 1,2, Alja Crnej 2 1 VIROS Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria 2 Moorfields.
In-vitro measurement of Intra- Ocular Pressure Alex Luce Undergraduate Research Symposium 2008.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Tonometry Objective measurement of IOP based, most commonly, on the forces required to flatten the cornea,or the degree of corneal indention produced.
Comparison of the Diaton Transpalpebral Tonometer Versus TonoPen- Applination Theodore H. Curtis, M.D.1, Douglas L Mackenzie, M.D.1, Robert J. Noecker.
Naomi R. Goldberg, MD PhD Kenneth J. Wolf, MD Eric J. Wolf, MD FACS The authors have no financial interest in the subject matter of this poster. Comparison.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Ahmed El-Massry, M.D. Professor of Ophthalmology - Faculty of Medicine University of Alexandria Egypt long-Term Results of Corneal Biomechanical Changes.
Visual and IOP Outcomes after PRK in Pigment Dispersion Syndrome [Poster Number: P190] Kraig S. Bower, Denise A. Sediq, Charles D. Coe, Keith Wroblewski,
TONOMETER.
The recent advancement in the medical industry has given rise to the best healthcare and diagnostic devices. Today, Tonometer has created a revolution.
Corneal Hysteresis Role of Corneal Biomechanics in Refractive Surgery Luis Rodriguez, MD Anny Villegas, MD Clínica de Córnea Centro Médico Docente La Trinidad.
Minimizing Risk in Visian ICL Implantation.
Mathematical Description of the Ocular Response Analyzer Applanation Signal in Post-LASIK Ectasia Mujtaba A. Qazi, M.D. 1,2 David A. Luce, Ph.D. 3 Jay.
9. Juni 2016HS-Präsentation1 Tonometer Prisms Disposable versus reusable.
BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.
Concepts 3 Material 9 Method 10 Results/Discussion 11 Conclusion Questions.
Date of download: 7/8/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Dynamic Contour Tonometry: A Comparative Study on.
Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO.
CRF variations ( initial CRF – final CRF )
Intraocular pressure & tonometry
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
55th ASMR National Scientific Conference
Date of download: 10/26/2017 Copyright © ASME. All rights reserved.
Date of download: 12/25/2017 Copyright © ASME. All rights reserved.
R. S. Davidson1; N. Faberowski2; R. J. Noecker3; M. Y. Kahook1 1
2/24/2013.
Associate Professor of Ophthalmology
Federal University of São Paulo, Brazil
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
The Effect of Corneal Thickness on Ocular Drug Penetration
Box and whiskers plot for bIOP, Goldmann applanation tonometry IOP (GAT) and Goldmann adjusted (GATAdj) in ocular hypertension (OHT), primary open-angle.
Presentation transcript:

Recent Advances in IOP measurements Dr Deepak Megur Cataract and Glaucoma services Megur Eye Care Centre Bidar Karnataka

Tonometry Why…? Because…. “IOP is the only modifiable risk factor in Glaucoma” Most frequently examined parameter in the follow up of a glaucoma pt.

What to use…? Gold Standard Goldmann Applanation Tonometry TonoPen: Acceptable (SEAGIG Asia Pacific Glaucoma guidelines)

Factors affecting measured IOP. Central Corneal Thickness: Thicker Corneas: Artificially elevated IOP Thinner Cornea: Artificially decreased IOP Correction nomogram: 525 Micron 1 -3 mm hg per 40 micron deviation. ( SEAGIG Asia Pacific Guidelines 2004)

Central Corneal Thickness Measurement Ultrasonic Pachymeter Measured along / Before GAT Time of measurement, waking hours CCT Predicting Risk factor Prognostic significance Response to drugs

CCT independent IOP Measurements: Pascal’s Dynamic Contour Tonometry Contour Matching Ocular Response Analyzer: Corneal Hysteresis Less influenced by Corneal thickness and resistance

Pascal’s Dynamic Contour Tonometry. Slitlamp-mounted.. Direct measurement of pressure - no systematic errors from force-to-pressure conversion. Numerical display of result. No mechanical calibration required; self-calibrating. Convenient disposable tip prevents contamination and potential infection Battery operated - no cabling. Visual control of eye/tip interface through transparent SensorTip. Single button operation.

Pascal’s Dynamic Contour Tonometry Dynamic contour tonometry (DCT) is a novel method which uses principle of contour matching instead of applanation. This is designed to reduce the influence of biomechanical properties of the cornea on measurement. These include corneal thickness, rigidity, curvature, and elastic properties. It is less influenced by corneal thickness but more influenced by corneal curvature than the Goldmann tonometer

DCT -Principles It uses a miniature pressure sensor embedded within a tonometer tip contour-matched to the shape of the cornea. The tonometer tip rests on the cornea with a constant appositional force of one gram. When the sensor is subjected to a change in pressure, the electrical resistance is altered and the PASCAL's computer calculates a change in pressure in concordance with the change in resistance

The contour matched tip has a concave surface of radius 10 The contour matched tip has a concave surface of radius 10.5 mm, which approximates to the shape of a normal cornea when the pressure on both sides is equal. The probe is placed adjacent to the central cornea. The integrated piezoresistive pressure sensor automatically begins to acquire data, measuring IOP 100 times per second. A complete measurement cycle requires about 8 seconds of contact time. The device also measures the variation in pressure that occurs with the cardiac cycle. (Ocular pulse Amplitude)

I-Care Rebound Tonometer Contact tonometer Rebound principle Digital reading Probes changed for every patient

Rebound Tonometers Principle Determine IOP by bouncing a small plastic tipped metal probe against the cornea. The device uses an induction coil to magnetise the probe and fire it against the cornea. As the probe bounces against the cornea and back in to the device it creates an induction current from which the intraocular pressure is calculated.

I-Care Rebound Tonometer Advantages: Fast No Anaesthetic required Pt friendly children Affected by corneal properties. Thickness Hysteresis

Transpalpebral tonometry Diaton tonometer (BiCOM, Inc) measuring intraocular pressure through the Eyelid. Transpalpebral tonometry does not involve contact with the cornea and does not require sterilization of the device or topical anesthetic during routine use. only moderate correlation with those provided by applanation tonometry More affected by the corneal thickness than Goldmann tonometry.

Diaton tonometer Principle… The Diaton tonometer calculates pressure by measuring the response of a free falling rod the principle is based on Newton's second law, as it rebounds against the tarsal plate of the eyelid. The patient is positioned so that the tip of the device and lid are overlying sclera.

Non-contact tonometry or air-puff tonometry It uses a rapid air pulse to applanate the cornea. Corneal applanation is detected via an electro-optical system. Intraocular pressure is estimated by detecting the force of the air jet at the instance of applanation.

Non-contact tonometry or air-puff tonometry A fast and simple way to screen for high IOP. However, modern non-contact tonometers have been shown to correlate well with Goldmann tonomtery measurements Particularly useful in children and other non-compliant patient groups. non-contact tonometry which reduces the potential for disease transmission…?