Simulated Moving Bed Chromatography in the Pharmaceutical Industry Ron Bates Bristol-Myers Squibb April 19, 2004.

Slides:



Advertisements
Similar presentations
Batch Distillation.
Advertisements

Introduction to Chromatography
Gas Chromatography.
Absorption and Stripping
Chromatography.
CHAPTER 14 CHEMICAL EQUILIBRIUM
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
ERT 313/4 BIOSEPARATION ENGINEERING MASS TRANSFER & ITS APPLICATIONS
Lecture 3. Adsorption on the interphase of liquid-gas Prepared by PhD Falfushynska Halina.
Simulated Moving Bed Chromatography Chemistry 230 Chemical Separations Presented by Brenden Jiang and Leonard Bellini.
Chem. 31 – 4/15 Lecture. Announcements I Exam 2 – Hope to have graded by next Monday Lab Reports –AA report now due Monday, 4/20 (best to try to complete.
Analytical Chemistry Section D Separation Technique.
Paper and Thin layer Chromatography
DR ZIAD W JARADAT PROTEIN BIOTECHNOLOGY BT 452 Chapter 3 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY.
Chromatography.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
CHEN 4470 – Process Design Practice Dr. Mario Richard Eden Department of Chemical Engineering Auburn University Lecture No. 3 – Overview of Mass Exchange.
Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
CHAPTER II PROCESS DYNAMICS AND MATHEMATICAL MODELING
Chapter 6 - Chromatography
A First Course on Kinetics and Reaction Engineering
Chromatography Separates components in mixture: Based on - polarity
Chromatographic separations Chapter 26 The “stuff” you do before you analyze a “complex” sample.
Model: Chromatography
Chromatography Chapter 6.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
LECTURE 9 CHROMATOGRAPHIC SEPARATIONS The “stuff” you do before you analyze a “complex” sample.
Supercritical Fluid Chromatography SFC Chromatographic Fundamentals Practical Verification of SFC Theoretical Description of SFC / Scale-up SFC on a Preparative.
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
© 2015 Carl Lund, all rights reserved A First Course on Kinetics and Reaction Engineering Class 31.
INTRODUCTION TO CHROMATOGRAPY
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Introduction to Chromatography Definition Chromatography is a separation technique based on the different interactions of compounds with two phases, a.
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
© 2014 Carl Lund, all rights reserved A First Course on Kinetics and Reaction Engineering Class 12.
Bioseparation Engineering Introduction. Biotechnology built on the genetic manipulation of organisms to produce commercial products or processes Biochemical.
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
The Chromatogram  Terms:  Retention time  Peak area  Peak width (at half height, at base)  Peak height  Void time/volume  Adjusted retention time.
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Separation Techniques
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
Chem. 231 – 2/11 Lecture.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Lecture 8 Peak Parameters and Quantitative chromatography
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Chromatography PlanarColumn Paper TLC (Thin layer chromatography)
Principles of chromatography
Downloaded from کروماتوگرافی CHROMATOGRAPHY Downloaded from
PREPARED BY VAISHNANI BHAVIN M.PHARMA-I (Q.A.). Qualitative error sources in HPLC: Poor separation power. Some special substances from the samples can.
DESIGN OF ADSORPTION SYSTEMS. Conceptual design of adsorption systems conceptual design has a variety of definitions but is generally understood to lie.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Lecture – 1 GEB 308 Summer 2016.
Chem. 133 – 5/9 Lecture.
Chem. 133 – 5/11 Lecture.
Chem. 31 – 11/1 Lecture.
High Performance Liquid Chromatography (HPLC)
An Introduction to Chromatographic Separations
Retention and phase distribution
Principle of separation of different components:
CHROMATOGRAPHY Chromatography : It is a physical method of separation in which the components to be separated are distributed between two phases, one.
High-Performance Liquid Chromatography
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
High performance liquid chromatography (HPLC)
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
David Thornton1, Xiqin Yang1, Gary Yanik2 and Leo Hsu1*
High-Performance Liquid Chromatography
Presentation transcript:

Simulated Moving Bed Chromatography in the Pharmaceutical Industry Ron Bates Bristol-Myers Squibb April 19, 2004

Outline Short Biography What is Bristol-Myers Squibb Chromatography –Batch vs continuous HPLC, LC, SMB, P-CAC Simulated Moving Bed Chromatography –Introduction –Theory (brief) –Operation –Applications in the Pharmaceutical Industry

B.S. Chemical Engineering, RPI, 1993 Ph.D. Biochemical Engineering, University of Maryland, Baltimore County, 1999 –Focus: ion-exchange chromatography Pfizer, Groton, CT, –Focus: small molecule chromatography, HPLC, LC, SFC, SMB, FLASH, extraction, crystallization, precipitation Bristol-Myers Squibb, Syracuse, NY, 2003-present –Focus: protein chromatography

Bristol-Myers Squibb Top-ten pharmaceutical company Products in numerous therapeutic areas Cardiovascular & Metabolic DiseasesMental Health Pravachol, CoumadinAbilify Headache and MigraneInfectious Diseases ExcedrinReyataz, Sustiva Oncology Erbitux, Taxol Strong pipeline focused in 10 therapeutic areas –Oncology, Cardiovascular, Infectious Diseases, Inflammation, etc. Sites around the world –U.S. Research/Manufacturing sites MA, NY, NJ, CT, IL, Puerto Rico

Bristol-Myers Squibb Syracuse, NY Clinical and Commercial Manufacturing Plant –Small-molecule pilot plants Process development and optimization Clinical manufacturing –Penicillin-based products Last US-based Penicillin manufacturer –Bio-synthetic products –Biotechnology Development, Manufacturing, Analytical Biosciences, Quality Control / Assurance

Bristol-Myers Squibb Syracuse, NY - Biotechnology Two lead protein therapeutics –Abatacept: commericial in 2005 Commercial-scale manufacturing Commercial launch out of Syracuse Facility BLA filing – Dec –LEA29Y: Phase III clinical trials in 2005 Development for next generation process Clinical production in 2004 Expansion in analytical and quality groups to support processes

Batch vs. Continuous Chromatography

Discrete starting and ending points –Example: 10 minute HPLC cycle –Types: GC, HPLC, FLASH, FPLC, LC, etc. –Can be run in many modes: Linear, overloaded, frontal, etc. Batch Chromatography

(Raffinate) Feed Desorbent Effluent to Waste Load Elution Effluent to Waste DesorbentElution (Extract) (To Waste) Strong Solvent Regeneration Reference: Linda Wang, Perdue University

Batch Chromatography Empty zone

Continuous Chromatography Feed is loaded onto column and product is collected continuously Annular (P-CAC) –Preparative continuous annular chromatography Countercurrent –Simulated moving bed chromatography (SMB) Feed column

P-CAC Reference: Genetic Engineering News, Oct. 1, 1999

P-CAC Reference: Genetic Engineering News, Oct. 1, 1999

P-CAC Reference: Genetic Engineering News, Oct. 1, 1999

P-CAC Reference: Genetic Engineering News, Oct. 1, 1999

Simulated Moving Bed Chromatography (SMB)

What is SMB SMB is Simulated Moving Bed Chromatography. SMB is continuous countercurrent chromatography. The feed is pumped into the system and two (or more) product streams are continuously collected. SMB has been used for the production of millions of tons of bulk commodities (p-xylene, high fructose corn syrup, etc...) for the past four decades. Due to improvements in column and equipment technology, SMB has recently been used in the pharmaceutical industry (Sandoz, SmithKline, UCB, Pfizer). –HPLC costs: $100/kg to $5000/kg –SMB costs: $50/kg to $200/kg

SMB versus HPLC Advantages of SMB: –Lower solvent utilization (up to 10 times less than batch HPLC) –Generally can use less expensive, larger stationary phases –Able to get high recovery and high purity –Sometimes better productivity –Lower labor and QC costs –Only partial separation of solutes is required to obtain high purity. –Higher yield than batch – 10% more than batch. –High throughput – 5 to 10 fold increase. –Lower solvent consumption – An order of magnitude lower. –Continuous process. Disadvantage of SMB: –Binary separation only –Complexity

Commercial Applications of SMB Hydrocarbons Sugars Agrochemicals Antibiotics Peptides Chiral Drugs –Gaining tremendous momentum – FDA approves of the technology –Chiral resin manufacturers sell resins specifically made for SMB Proteins? –Useful as polishing step? SEC: remove aggregated form of product –Multicomponent separations more difficult than traditional uses 8, 12, even 16 zone systems being examined

Basic Principle Mobile Phase Feed Continuous Countercurrent Chromatography stationary column A sample is injected in the centre of a stationary column The two components move at different speeds and are separated If we now move the column from right to left, at a speed halfway between that of the solutes, they now move in different directions...

Basic Principle Mobile Phase Feed column The two solutes now move in different directions relative to a stationary observer. If the column is very long, the bands will continue to separate. Continuous Countercurrent Chromatography

Basic Principle Mobile Phase Feed column If we continue to add sample at the center, the components will continue to separate Continuous Countercurrent Chromatography

This is clearly a continuous system, but there are problems. The column needs to be of infinite length, the actual moving of solids is very difficult and some way to introduce and remove the sample and the products are needed. We solve this by cutting the column into small segments and simulating the moving of them Basic Principle Mobile Phase Feed column Continuous Countercurrent Chromatography

The feed and solvent inlets are now placed between the segments and are moved each time a segment is moved from one end to the other Basic Principle Mobile Phase Feed column Continuous Countercurrent Chromatography

Products are removed by bleeding off a carefully calculated flow at suitable exit points. This changes the velocity of the bands in the column and forces the products to move toward the ports This ensures that the column segments are clean before they are moved and that the solvent can be recycled directly back through the system Mobile Phase Basic Principle Mobile Phase Feed column Continuous Countercurrent Chromatography

True Moving Bed

Binary Separation in a True Moving Bed Desorbent Raffinate Extract Feed Extract Raffinate Time : t Time : t +  t Reference: Linda Wang, Perdue University

Binary Separation in a True Moving Bed Desorbent Raffinate Extract Feed ExtractRaffinate Time : t + 3  t Feed Time : t + 2  t Desorbent Reference: Linda Wang, Perdue University

Binary Separation in a True Moving Bed Desorbent Raffinate Extract Feed Extract Raffinate Time : t + 4  t Time : t + 5  t Reference: Linda Wang, Perdue University

TMB to SMB Since it’s very difficult to move solids, true countercurrent chromatography does not exist. Instead, the bed is broken into many fractions and their movement is simulated by changing the inlet and outlet ports

Simplified SMB - 1 Feed Solvent ExtractRaffinate Feed Solvent ExtractRaffinate The system is started..... A frontal elution separation occurs in Section

Simplified SMB - 2 Feed Solvent ExtractRaffinate Feed Solvent ExtractRaffinate The separation continues..... Eventually the front of pure product 1 reaches the outlet. It is distributed between the final Section and the product port

Feed Solvent ExtractRaffinate Simplified SMB - 3 Feed Solvent ExtractRaffinate Finally, the mixed product reaches the outlet. To avoid collecting impure material, it is necessary to move the columns 1 position upstream.

Feed Solvent ExtractRaffinate Simplified SMB - 4 Feed Solvent ExtractRaffinate The frontal separation continues; at the same time, the slow moving product starts to separate from the tail of the mixed product band in Section 2 Eventually the fast moving product again reaches the outlet and more pure product is collected.

Feed Solvent Extract Raffinate Simplified SMB - 5 When the mixed band reaches the end of Section 3 its tail has left Section 2 (if the separation has been correctly designed) and only pure product 2 remains in Section 2. Feed Solvent Extract Raffinate To avoid collecting impure raffinate, the columns are moved once more. Now, the pure component 2 is in Section 1.

Feed Solvent Extract Raffinate Simplified SMB - 6 Feed Solvent Extract Raffinate The second component is now collected at the Extract port while the separation continues in Sections 2 and 3. The faster component reaches the Raffinate port and is again collected; note that the outlet concentrations are neither constant nor concurrent.

Feed Solvent Extract Raffinate Simplified SMB - 7 Feed Solvent Extract Raffinate Eventually, the mixed zone reaches the raffinate port and the columns are again switched. This simplified system is now in a steady state mode and will continue to cycle. Switch

The moving of the bed is simulated by moving the points of feed and mobile phase addition, as well as the points of raffinate and extract removal while keeping the column positions fixed. Time = 0 Extract Feed Raffinate Mobile Phase Feed Raffinate Time = 1 Mobile Phase Extract Packed Column

The zones are made up of one or more columns Six-column SMB System Eight-column SMB system IIIIIIIV IIIIIIIV IIIIIIIVIIIIIIIV SMB Configurations

SMB Operation

Theory – Governing Equations For another day… Maybe

Theory – Working Equations / Definitions k’ 1 = capacity factor = (t r -t 0 ) / t 0 α = k’ 2 / k’ 1 R s = 2* (t r1 -t r2 ) / (w 1 -w 2 )

SMB – Method Development 1.Start with linear batch experiments 2.Increase either mass or volume of load to overload the column 3.Calculate isotherm 4.Determine resistance to mass transfer (if important) 5.Calculate necessary flow rates 6.Optimize (either on-the-fly or with a proven model)

Linear Chromatography

Batch Chromatography Experiments Feed concentration –As concentrated as possible to minimize disruption to Zone III velocity –Need to run batch experiments at appropriate concentrations and solvents Desorbent composition –Solubility of products –Strength Trade-off between time and mobile phase utilization Sorbent –Capacity, selectivity, resolving power

Feed Concentration Feed concentration: Consider two systems –A: Concentrated feed –B: Dilute feed Run batch experiments to examine effect of concentration

Desorbent composition Multiple trade-offs: Solubility of products and effectiveness of the solvent –Not always complimentary –Often solubility dictates solvent composition Speed –Low k’ = high throughput More wear and tear on equipment Larger system needed –Large k’ = low throughput Less wear and tear Smaller system acceptable

Choice of Sorbent Capacity: higher = better? Selectivity: higher α = better? Resolving power: higher R s = better?

Linear Chromatography

Volume Overloading

Batch Chromatography to SMB Initial Operating Conditions Determine optimal feed concentration, stationary phase and mobile phase composition (highest α with lowest capacity factors) Calculate isotherm and mass transfer resistances Either use software package or rules of thumb to generate initial SMB flow rates

Zone velocities v I = v Recycle + v D v II = v I - v X v III = v II + v F v Recycle = v III - v Raff Solvent Mass Balances – Flow Rates IIIIIIIV vIvI v II v III v Recycle vXvX v Raff vFvF vDvD Overall Mass Balance v D + v F = v X + v Raff

Flow rates Commercial SMB design models available –Given batch results from 5-10 column experiments Flow rate, feed concentrations, retention times Solubility data –Predict zone velocities, productivities –Problems: Usually assumes simple adsorption model and lumped mass transfer coefficients Often difficult to interpret overloaded chromatograms Rules of Thumb –Educated guesses based upon batch results from linear and overloaded experiments V II and V III ratio (based upon retention times) V I to flush back-side of slowest component from zone I Feed concentration and flow rate based upon solubility data and solvent mass balance

Period The period is the time a column stays in one zone also called switching time. Changing the period has the effect of changing all 4 zones simultaneously, thus either speeding up or slowing down the solutes

Example of switching time

SMB Optimization Independent variables: –Flow rates Recycle, Desorbent, Raffinate, Extract, Feed –Period (switching time) –That’s it. Procedure: –Get the system bound, manipulate the flow rates to maximize throughput at required purity

SMB Optimization IIIIIIIV vIvI v II v III v Recycle vXvX v Raff vFvF vDvD Questions: What is the effect of increasing the Zone I flow rate? –How would one accomplish this? Zone II? Zone III? What if the system is underutilized (i.e., more feed can be added to the system) – how would one do this without affecting the other zone flow rates?

Two component SMB System Feed Desorbent Extract Raffinate Conc. I II III IV Bed Position

SMB Optimization IIIIIIIV vIvI v II v III v Recycle vXvX v Raff vFvF vDvD Questions: Extract contains too much of the weakly adsorbed species – what do you do? If situation was reversed?

Two component SMB System Feed Desorbent Extract Raffinate Conc. I II III IV Bed Position

SMB Optimization IIIIIIIV vIvI v II v III v Recycle vXvX v Raff vFvF vDvD Questions: Extract contains too much of the weakly adsorbed species – what do you do? If situation was reversed?

Two component SMB System Feed Desorbent Extract Raffinate Conc. I II III IV Bed Position

Examples of SMB

Two component SMB System

Multi-component System Single-component pulse data Reference: Linda Wang, Perdue University

Multi-Component SMB System Desorbent Extract (2, 3) Feed (1, 2, 3) Raffinate (1) I II IIIIV 1 Fast Solute 2 Intermediate Solute 3 Slow Solute Concentration Bed Position Reference: Linda Wang, Perdue University

Complete Separation in Tandem SMB Column Number C i /C F,i Des.Ext.FeedRaf. Sulfuric Acid Glucose Acetic Acid C i /C F,i Des.Ext.FeedRaf. Reference: Linda Wang, Perdue University

Profiles of a Parallel SMB Glucose yield: 94% Glucose purity: 99% Reference: Linda Wang, Perdue University

Other Questions?