LIGO NSF review, 11/10/05 1 AdLIGO Optical configuration and control Nov 10, 2005 Alan Weinstein for AdLIGO Interferometer Sensing and Control (ISC) and.

Slides:



Advertisements
Similar presentations
Gravitational Wave Astronomy Dr. Giles Hammond Institute for Gravitational Research SUPA, University of Glasgow Universität Jena, August 2010.
Advertisements

Spring LSC 2001 LIGO-G W E2 Amplitude Calibration of the Hanford Recombined 2km IFO Michael Landry, LIGO Hanford Observatory Luca Matone, Benoit.
LIGO NSF review, 11/10/05 1 AdLIGO Optical configuration and control Nov 10, 2005 Alan Weinstein for AdLIGO Interferometer Sensing and Control (ISC) and.
Optical Springs at the 40m 1 QND Workshop, Hannover Dec 14, 2005 Robert Ward for the 40m Team Osamu Miyakawa, Rana Adhikari, Matthew Evans, Benjamin Abbott,
Caltech 40m Current Issues University of Florida Kentaro Somiya.
NSF : Nov. 10, LIGO End to End simulation overview  Time domain simulation written in C++  Like MATLAB with Interferometer toolbox  Major physics.
LIGO- G05XXXX-00-R 40m meeting, May Experimental update from the 40m team 40m TAC meeting May 13, 2005 O. Miyakawa, Caltech and the 40m collaboration.
40m TAC, 10/13/05 1 Lock acquisition procedure towards detuned RSE Start with no DOFs controlled, all optics aligned. Re-align each 1.5 hours. ITMy ITMx.
40m TAC, 10/13/05 1 Report to the 40m Technical Advisory Committee October 13, 2005 The 40m Team Ben Abbott, Rana Adhikari, Dan Busby, Jay Heefner, Osamu.
Koji Arai – LIGO Laboratory / Caltech LIGO-G v1.
Towards dual recycling with the aid of time and frequency domain simulations M. Malec for the GEO 600 team Max-Planck-Institut für Gravitationsphysik Albert-Einstein-Institut.
Joshua Smith December 2003 Detector Characterization of Dual-Recycled GEO600 Joshua Smith for the GEO600 team.
Design of Stable Power-Recycling Cavities University of Florida 10/05/2005 Volker Quetschke, Guido Mueller.
LIGO- G R 40m Progress, LSC meeting, Aug m Laboratory Upgrade Progress Report Osamu Miyakawa, Caltech 40m Technical Advisory Committee.
LIGO-G R Aspen Current Status of the 40m Detuned RSE Prototype Seiji Kawamura 2004 Aspen Winter Conference on Gravitational Waves Gravitational.
Degeneracy for power-recycling and signal recycling cavities in Advanced Virgo.
Stefan Hild October 2007 LSC-Virgo meeting Hannover Interferometers with detuned arm cavaties.
1 1.ISC scope and activities 2.Initial Virgo status 3.Design requirements 4.Reference solution and design status 5.Plans toward completion 6.Technical.
LIGO- G R 40m Progress, LSC meeting, 3/031 40m Laboratory Upgrade Progress Report Osamu Miyakawa, Caltech 40m Technical Advisory Committee LIGO-G R.
GEO‘s experience with Signal Recycling Harald Lück Perugia,
Amaldi conference, June Lock acquisition scheme for the Advanced LIGO optical configuration Amaldi conference June24, 2005 O. Miyakawa, Caltech.
LIGO- G R Telecon on June, Mach-Zender interferometer to eliminate sidebands of sidebands for Advanced LIGO Osamu Miyakawa, Caltech.
LIGO- G R Amaldi7 July 14 th, 2007 R. Ward, Caltech 1 DC Readout Experiment at the Caltech 40m Laboratory Robert Ward Caltech Amaldi 7 July 14.
Variable reflectivity signal-recycling mirror and control Stefan Goßler for the experimental team of The ANU Centre of Gravitational Physics.
LIGO- G R Sensing and control, SPIE conference, June Sensing and control of the Advanced LIGO optical configuration SPIE conference at.
Advanced Virgo Optical Configuration ILIAS-GW, Tübingen Andreas Freise - Conceptual Design -
Koji Arai – LIGO Laboratory / Caltech LIGO-G v2.
Conversion of the Glasgow 10m Prototype for Detuned Operation Bryan Barr Institute for Gravitational Research University of Glasgow LSC - AIC August 13.
LSC-March  LIGO End to End simulation  Lock acquisition design »How to increase the threshold velocity under realistic condition »Hanford 2k simulation.
1 1.Definition 2.Deliverables 3.Status of preliminary design 4.Risks 5.Tasks to be done 6.Decisions to be taken 7.Required simulations 8.Planning ISC workshop:
LIGO- G R Aspen winter conference, January Toward the Advanced LIGO optical configuration investigated in 40meter prototype Aspen winter.
LIGO- G R LIGO seminar, November Optical spring and optical resonance in the 40m Detuned RSE interferometer LIGO seminar November 1, 2005.
AIGO 2K Australia - Italy Workshop th October th October 2005 Pablo Barriga for AIGO group.
LIGO- G R 40m Progress, LSC meeting, 8/021 40m Laboratory Upgrade Progress Report Dennis Ugolini, Caltech 40m Technical Advisory Committee LIGO-G R.
Advanced LIGO Simulation, 6/1/06 Elba G E 1 ✦ LIGO I experience ✦ FP cavity : LIGO I vs AdvLIGO ✦ Simulation tools ✦ Time domain model Advanced.
Dual Recycling in GEO 600 H. Grote, A. Freise, M. Malec for the GEO600 team Institut für Atom- und Molekülphysik University of Hannover Max-Planck-Institut.
Institute for Cosmic Ray Research Univ. of Tokyo Development of an RSE Interferometer Using the Third Harmonic Demodulation LIGO-G Z Osamu Miyakawa,
Aligning Advanced Detectors L. Barsotti, M. Evans, P. Fritschel LIGO/MIT Understanding Detector Performance and Ground-Based Detector Designs LIGO-G
LIGO- G R 40m weekly meeting, Jan 05, Explore demodulation phase for DDM on 40m RSE prototype Osamu Miyakawa, Caltech LIGO-G R.
Jan 17th 2006Ward Candicacy1 Length Sensing and Control for an Advanced Gravitational Wave Detector Robert Ward PhD Candidacy Caltech, 17 Jan 2006.
MOTIVATION OF THIS PROJECT Testing the control scheme with a prototype interferometer to demonstrate the control of the tuned RSE for LCGT is necessary.
1 Locking in Virgo Matteo Barsuglia ILIAS, Cascina, July 7 th 2004.
Optical Spring Experiments With The Glasgow 10m Prototype Interferometer Matt Edgar.
LIGO-G Z March 2007, LSC meeting, Osamu Miyakawa 1 Osamu Miyakawa Hiroaki Yamamoto March 21, 2006 LSC meeting Modeling of AdLIGO arm lock acquisition.
Monica VarvellaIEEE - GW Workshop Roma, October 21, M.Varvella Virgo LAL Orsay / LIGO CalTech Time-domain model for AdvLIGO Interferometer Gravitational.
LIGO- G R 40m/AdLIGO, LSC, August Issues in sensing and control of the 40m and Advanced LIGO optical configuration LSC meeting, August.
LIGO-G D Advanced LIGO Systems & Interferometer Sensing & Control (ISC) Peter Fritschel, LIGO MIT PAC 12 Meeting, 27 June 2002.
ET-ILIAS_GWA joint meeting, Nov Henning Rehbein Detuned signal-recycling interferometer unstableresonance worsesensitivity enhancedsensitivity.
1 Fumiko 2006 Elba Meeting Current status of the 4m RSE.
Testing Advanced LIGO length sensing and control scheme at the Caltech 40m interferometer. at the Caltech 40m interferometer. Yoichi Aso*, Rana Adhikari,
Current Status of Main Interferometer Design Yoichi Aso 2011/2/4, LCGT f2f Meeting.
Main Interferometer Subsystem
Interferometer configurations for Gravitational Wave Detectors
Demonstration of lock acquisition and optical response on
GEO600 Control aspects where do the error signal come from?
Yoichi Aso on behalf of the LCGT ISC Group
The Advanced LIGO Angular Control System (ASC) (Hanford edition)
Design of Stable Power-Recycling Cavities
Homodyne or heterodyne Readout for Advanced LIGO?
Current Status of the 40m Detuned RSE Prototype
Workshop on Gravitational Wave Detectors, IEEE, Rome, October 21, 2004
Heterodyne Readout for Advanced LIGO
40m Laboratory Upgrade Progress Report
Effect of sideband of sideband on 40m and Advanced LIGO
Variable reflectivity signal-recycling mirror and control
Advanced LIGO optical configuration investigated in 40meter prototype
Estimation of each loop shot noise limit for AdLIGO
Progress report from 40m team for the Advanced LIGO
Homodyne detection: understanding the laser noise amplitude transfer function Jérôme Degallaix Ilias meeting – June 2007.
Presentation transcript:

LIGO NSF review, 11/10/05 1 AdLIGO Optical configuration and control Nov 10, 2005 Alan Weinstein for AdLIGO Interferometer Sensing and Control (ISC) and the 40 meter lab

LIGO NSF review, 11/10/05 2 AdLIGO optical configuration and control  Problem: If the current Initial LIGO optical configuration (power-recycled Michelson with Fabry-Perot arms) is retained in AdLIGO, the increased laser power (needed for better sensitivity in the high-frequency shot-noise-limited regime) will put intolerable thermal load on the transmissive (absorptive, lossy) optics in the power recycling cavity (BS, ITM substrates).  Solution: increase the finesse (optical gain) of the F-P arms, decrease the gain in the PRC. 40 KG FUSED SILICA ADVANCED LIGO LAYOUT BS Beam Splitter ITM Input Test Mass ETM End Test Mass PD Photodiode PRM Power Recycling Mirror SRM Signal Recycling Mirror

LIGO NSF review, 11/10/05 3 Advanced LIGO optical configuration Detuning PRM BS FP cavity Laser GW signal Power  Problem: Increasing the finesse of the arms causes the cavity pole frequency to decrease, leading to reduced bandwidth for GW signal.  Solution: resonant sideband subtraction!  the PRM acts to increase the optical gain of the arms, for the carrier.  the SEM acts to decrease the optical gain of the arms, for the GW signal sidebands – the signal sidebands are resonantly extracted out the asymmetric port.  This decouples the problem of storing the carrier power (CARM+PRC) from extracting the signal (DARM+SEC), allowing us to optimize both for best quantum-limited response to signal, and apportionment of optical gain / thermal load. SEM

LIGO NSF review, 11/10/05 4 Tuning the signal response r ITM SR RSE r CC RSESR tuned (narrow band)  = 2kl s = 4  l s (f carr +f sig )/c The red curve corresponds to r = r ITM, ie, no SR mirror  Better solution: Detuned signal extraction optimizes the signal extraction for a signal frequency away from DC, allowing us to resonantly enhance the response at, say, 40 Hz, shaping the frequency response to optimize sensitivity in the presence of other noise sources (thermal, seismic.. which are overwhelming near DC).  By choosing the phase advance of the signal (f carr +f sig ) in the signal recycling cavity, can get longer (SR) or shorter (RSE) storage of the signal in the arms:

LIGO NSF review, 11/10/05 5 Using DR to optimize sensitivity Now we can independently tune h DC and f polarm to optimize sensitivity (eg, hug the thermal noise curve)

LIGO NSF review, 11/10/05 6  Newtonian background, estimate for LIGO sites  Seismic ‘cutoff’ at 10 Hz  Suspension thermal noise  Test mass thermal noise  Unified quantum noise dominates at most frequencies for full power, broadband tuning Optimize detuned RSE response, in the presence of other noise sources, to maximize BNS range. Projected Adv LIGO Detector Performance 10 Hz100 Hz 1 kHz Initial LIGO Advanced LIGO Strain

LIGO NSF review, 11/10/05 7 Control of the AdLIGO optical configuration  Problem: the detuned signal extraction, on top of the power- recycled Michelson with Fabry-Perot arms, is a very complicated optical configuration. The current Initial LIGO sensing scheme has no hope of acquiring lock and controlling the mirrors in AdLIGO. »The Initial LIGO scheme uses one pair of RF sidebands for PDH reflection locking of the arms and PRC, and Schnupp transmission locking for the Michelson. The signals for the short degrees of freedom (PRC and MICH) would be overwhelmed by the large signals from the arms, if the arms weren’t tightly controlled: gain hierarchy.  Solution: enhance the length signal extraction by using two pairs of RF sidebands, used in clever ways. »The signals for the short degrees of freedom (PRC, MICH and SEC) can be completely decoupled from the large signals from the arms; the length sensing matrix is much more diagonal, no gain hierarchy needed. Expect control to be more robust!

LIGO NSF review, 11/10/05 8 AdLIGO signal extraction scheme  Arm cavity signals are extracted from beat between carrier and f 1 or f 2.  Central part (Michelson, PRC, SRC) signals are extracted from beat between f 1 and f 2, not including arm cavity information. f1f1 -f 1 f2f2 -f 2 Carrier (Resonant on arms) Single demodulation Arm information Double demodulation Central part information  Mach-Zehnder installed to eliminate sidebands of sidebands.  Only + f 2 is resonant on SRC.  Unbalanced sidebands of +/-f 2 due to detuned SRC produce good error signal for Central part. ETMy ETMx ITMy ITMx BS PRM SRM 4km f2f2 f1f1

LIGO NSF review, 11/10/ DOF for length control : L  =( L x  L y ) / 2 : L  = L x  L y : l  =( l x  l y ) / 2 =2.257m : l  = l x  l y = 0.451m : l s =( l sx  l sy ) / 2 =2.15m PortDem. Freq. LL LL ll ll l s SPf1f E-9-1.2E-3-1.3E-6-2.3E-6 APf2f2 -4.8E-911.2E-81.3E-3-1.7E-8 SP f1  f2f1  f2 -1.7E-3-3.0E E-2-1.0E-1 AP f1  f2f1  f2 -6.2E-41.5E-37.5E-117.1E-2 PO f1  f2f1  f2 3.6E-32.7E-34.6E-1-2.3E-21 Signal Extraction Matrix (in-lock) Common of arms Differential of arms Power recycling cavity Michelson Signal recycling cavity Laser ETMy ETMx ITMy ITMx BS PRM SRM SP AP PO lxlx lyly l sx l sy L x =38.55m Finesse=1235 L y =38.55m Finesse=1235 Phase Modulation f 1 =33MHz f 2 =166MHz T =7% G PR =14.5

LIGO NSF review, 11/10/05 10 Full lock of AdLIGO optical configuration at the 40 Meter prototype  Problem: this is all fine in theory, but does it work in practice? »Apparently so! We can use this scheme to acquire lock and control the 40m prototype interferometer, even during the noisy daytime. »Full lock acquisition is now relatively routine, and robust. »The optical response is precisely as expected, including the resonant enhancement (at the 40m, this is at 4 kHz; in AdLIGO, it will be at ~40 Hz) as well as the optical spring (in the 40m, at ~50 Hz). »In the process, we have learned a great deal about the intricacy of the AdLIGO optical design, and how to control it. »Exploiting the enhanced controls and more diagonal sensing matrix, we are developing deterministic lock acquisition procedures, step-by-step approaches to take the wait and chance out of lock acquisition.

LIGO NSF review, 11/10/05 11 The path to full RSE at the 40m Carrier 33MHz 166MHz Oct Detuned dual recycled Michelson Nov Arm lock with offset in common mode Oct RSE ITMy ITMx BS PRM SRM ETMx ETMy Shutter Reducing offset

LIGO NSF review, 11/10/05 12 Frequency sweep of optical spring ~1900W ~270W

LIGO NSF review, 11/10/05 13 Optical spring and Optical resonance in differential arm mode of detuned RSE Optical gain of L- loop DARM_IN1/DARM_OUT divided by pendulum transfer function Optical spring and optical resonance of detuned RSE were measured. Frequency of optical spring depends on cavity power, mass, detuning phase of SRC. Frequency of optical resonance depends on detuning phase of SRC. Theoretical line was calculated using A. Buonanno and Y.Chen’s equations.

LIGO NSF review, 11/10/05 14 Optical spring in E2E Calculated by time domain simulation No length control Lock lasts ~0.7sec, so statistics at low frequency is not good. Simple length control required Calculation time ~5min using DRMI summation cavity

LIGO NSF review, 11/10/05 15 But will it work in AdLIGO?  AdLIGO has »4 km arms (longer storage time) »quadruple pendulums (much quieter, but also much less actuation force on the test mass) »advanced seismic isolation (much quieter)  No problems are foreseen, but we must extrapolate from 40m to AdLIGO with detailed simulation -> e2e.  Will maintaining lock be more difficult in Adv LIGO? We might expect it will be significantly easier, because of the much quieter seismic platform, powerful multiple pendulum isolation, and more diagonal length sensing plant. »This is an inference that must be verified through tests (LASTI) and simulation (e2e).

LIGO NSF review, 11/10/05 16 Differences between AdvLIGO and 40m prototype  100 times shorter cavity length  Arm cavity finesse at 40m chosen to be = to AdvLIGO ( = 1235 ) »Storage time is x100 shorter  Control RF sidebands are 33/166 MHz instead of 9/180 MHz »Due to shorter PRC length, less signal separation  LIGO-I 10-watt laser, negligible thermal effects »180W laser will be used in AdvLIGO.  Noisier seismic environment in town, smaller isolation stacks »~1x10 -6 m at 1Hz  LIGO-I single pendulum suspensions »AdvLIGO will use triple (MC, BS, PRM, SRM) and quad (ITMs, ETMs) suspensions.