International Training Course, Potsdam ORFEUS Workshop, Vienna IRIS Metadata Workshop, Cairo 2009 IRIS Metadata Workshop, Foz do Iguacu 2010 E. Wielandt:

Slides:



Advertisements
Similar presentations
AC  DC: Using a full-wave diode rectifier circuit (used in the music system final project) The 20:1 turns ratio transformer here reduces the rms voltage.
Advertisements

Frequency modulation and circuits
Chapter 13 Transmission Lines
Measurement of Voltages and Currents
TRANSMISSION FUNDAMENTALS Recap Questions/Solutions
Part (2) : AC Circuits Lecture 1 د. باسم ممدوح الحلوانى.
Sine waves The sinusoidal waveform (sine wave) is the fundamental alternating current (ac) and alternating voltage waveform. Electrical sine waves are.
IRIS Metadata Workshop, Cairo 2009 IRIS Metadata Workshop, Foz do Iguacu 2010 International Training Course, Turkey 2010 E. Wielandt: Analog to Digital.
CHE 185 – PROCESS CONTROL AND DYNAMICS
International Training Course, Potsdam ORFEUS Workshop, Vienna IRIS Metadata Workshop, Cairo 2009 IRIS Metadata Workshop, Foz do Iguacu 2010 E. Wielandt:
Noise. Noise is like a weed. Just as a weed is a plant where you do not wish it to be, noise is a signal where you do not wish it to be. The noise signal.
Physics 434 Module 4-FFT - T. Burnett 1 Physics 434 Module 4 week 2: the FFT Explore Fourier Analysis and the FFT.
Alternating Current Circuits
Physics 434 Module 4-FFT – Thanks to Prof. Toby Burnett for writeups & lab 1 Physics 434: Continuing Module 4 week 2: the Fourier Transform Explore Fourier.
Chapter 5 AM, FM, and Digital Modulated Systems
Magnitude and Phase Measurements
 Distortion – the alteration of the original shape of a waveform.  Function of distortion analyzer: measuring the extent of distortion (the o/p differs.
Classification of Instruments :
SAMPLING & ALIASING. OVERVIEW Periodic sampling, the process of representing a continuous signal with a sequence of discrete data values, pervades the.
Calibration of TAMA300 in Time Domain Souichi TELADA, Daisuke TATSUMI, Tomomi AKUTSU, Masaki ANDO, Nobuyuki KANDA and the TAMA collaboration.
Chapter 15 Fourier Series and Fourier Transform
OSCILLATORS.
Self-Calibrating Audio Signal Equalization Greg Burns Wade Lindsey Kevin McLanahan Jack Samet.
PULSE MODULATION.
Numerical algorithms for power system protection Prof. dr. sc. Ante Marušić, doc. dr. sc. Juraj Havelka University of Zagreb Faculty of Electrical Engineering.
Copyright © 2009 Pearson Education, Inc. Chapter 30 Inductance, Electromagnetic Oscillations, and AC Circuits.
Lecture 1 Signals in the Time and Frequency Domains
SJTU Zhou Lingling1 Introduction to Electronics Zhou Lingling.
Electronics Involves the use of devices and circuits to control the flow of electric current to achieve some purpose. These circuits contain: Resistors,
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
Power Supply Design J.SHANMUGAPRIYAN.
Automatic Control Theory-
Understanding ADC Specifications September Definition of Terms 000 Analogue Input Voltage Digital Output Code FS1/2.
Electromagnetism Topic 12.2 Alternating Current. Rotating Coils Most of our electricity comes from huge generators in power stations. Most of our electricity.
EBB Chapter 2 SIGNALS AND SPECTRA Chapter Objectives: Basic signal properties (DC, RMS, dBm, and power); Fourier transform and spectra; Linear systems.
Fourier series. The frequency domain It is sometimes preferable to work in the frequency domain rather than time –Some mathematical operations are easier.
Part 1: Basic Principle of Measurements
EE210 Digital Electronics Class Lecture 2 March 20, 2008.
Vadodara Institute of Engineering kotanbi Active learning Assignment on Single phase AC CIRCUIT SUBMITTED BY: 1) Bhatiya gaurang.(13ELEE558) 2)
Managing Waveform Data and Related Metadata for Seismic Networks Cairo, Egypt, Nov 8 – 17, 2009 Modern Data Acquisition Systems – Reinoud Sleeman Modern.
Applied Circuit Analysis Chapter 11 AC Voltage and Current Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
COVERAGE TOPICS 1. AC Fundamentals AC sinusoids AC response (reactance, impedance) Phasors and complex numbers 2. AC Analysis RL, RC, RLC circuit analysis.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
Lecture 2: Measurement and Instrumentation. Time vs. Frequency Domain Different ways of looking at a problem –Interchangeable: no information is lost.
5. 4 Resolution The impulse can be separated is given by the resolution. The number of impulse can be distinguished in one quadrant of a 50c/s sine wave.
Chapter #1: Signals and Amplifiers
Chapter2 : SIGNALS 1st semester King Saud University
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. CHAPTER 6 Frequency Response, Bode.
Prototype Sensor Status and Measurements u Sensor Response Measurements u Mechanical Response u Noise Expectations u DAQ Status.
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
EEE 332 COMMUNICATION Fourier Series Text book: Louis E. Frenzel. Jr. Principles of Electronic Communication Systems, Third Ed. Mc Graw Hill.
2 nd semester nalhareqi King Saud University College of Applied studies and Community Service 1301CT By: Nour Alhariqi.
Measurement and Instrumentation
Dr. Michael Nasief.  Rotating electrical machines (ac generators)  Electronic oscillator circuits.
Chapter 3 – Diode Circuits – Part 2
FUNCTION GENERATOR.
Unit 3 Vibrationdata Sine Sweep Vibration.
Introduction to Electronics
Time Domain and Frequency Domain Analysis
Digital Control Systems (DCS)
Harmonic Distortion Analyzer, Wave Analyzer and Function Generator
SAMPLING & ALIASING.
Title International Training Course, Rabat 2012 E. Wielandt:
Introduction to Frequency Domain TIPL 4301 TI Precision Labs – ADCs
Chapter 5 AM, FM, and Digital Modulated Systems
Calibration of TAMA300 in Time Domain
UNIT-8 INVERTERS 11/27/2018.
Prediction of Orientation Selectivity from Receptive Field Architecture in Simple Cells of Cat Visual Cortex  Ilan Lampl, Jeffrey S. Anderson, Deda C.
Chapter 2 SIGNALS AND SPECTRA Chapter Objectives:
Presentation transcript:

International Training Course, Potsdam ORFEUS Workshop, Vienna IRIS Metadata Workshop, Cairo 2009 IRIS Metadata Workshop, Foz do Iguacu 2010 E. Wielandt: Relative (electrical) calibration of seismometers Title

Systematics Recorded? Assumed?

Text Relative calibration (determining the frequency response) A variety of signals - sinewaves, pulses, pseudo-random signals - can be used for seismometer calibration. However, it is risky to rely on the precision of a waveform generator. Preferably, the input signal should be recorded together with the output signal. The transfer function is defined as the complex gain for sinewaves, but in order to make practical use of this relationship, one must wait for a steady state after each change of the frequency. This is not practical for broadband seismometers. Also, we want a mathematical representation of the response, not a table for discrete frequenies. Modelling the output signal from the input signal (preferably in time domain), and matching the parameters of the mathematical model, is a more efficient method of determining the frequency response.

Simplest but not best: measuring the amplitude response of a geophone to sinewaves

By superimposing standardized response curves, the parameters can be directly determined ( 4.5 Hz geophone with 0.4 of crit. damping)

Text Resonance curves can of course be fitted automatically, and even the exact frequency of the sinewaves can be determined from the record. The only requirement is that the input sinewaves all have the same amplitude. This method is quite useful for the remote calibration of geophone-type sensors. The next slide shows the output signal from which the constants of a Geotech S13 in the GERESS array were determined with the SINCAL routine (download) as:. T0 = s, h = 0.774

sincal SINCAL2 best fit boots.avg. std.dev. Period Damping Gain

halfbridge If the geophone has no calibration coil, then the signal coil can be used for both input and output. The voltage across the coil caused by the input current can later be automatically subtracted from the output (program CALEX3, download).

10 Hz geophone Calibration of a 10 Hz field geophone with a half-bridge, using a square wave as an input. From top: input current, recorded output voltage, modeled output voltage, misfit. Note that the misfit is not the same for the mass jumping „up“ and „down“, indicating a dependence of the free period on mass position, i.e. a nonlinearity. Such problems can only be recognized in time domain.

cal. with arbitrary signals

Hardware used for calibration with a logarithmic sweep. The left box splits the signal into adjustable U, V, W components for the STS2, and can deliver purely „horizontal“ or „vertical“ calibration signals.

It is also possible to calibrate the U, V, and W sensors separately - the Z output may be used for this purpose - and then to average the U, V, W transfer functions or parameters with a matrix whose elements are the squares of those of the matrix transforming the U, V, W into the X, Y, Z components:

a sweep calibration Calibration of an STS2 seismometer with a sweep signal from 20 s to 400 s period. The rms residual is only 1/3000 of the rms output signal, and consists mainly of ambient long-period noise.

A slightly nonlinear seismometer (diode circuit added)

another sweep calibration Another example. The sweep this time covers a band from 20 s to 800 s. The relatively large and strange-looking residual is caused by a defective 16-bit digitizer that produces a small jump in every zero crossing. Time-domain modelling with the CALEX method helps to identify such problems.

Digitizers normally don’t need to be calibrated if the manufacturer’s specifications are clear and complete. You may want to check the scale factor, normally in microvolts per count, by connecting a battery and a digital voltmeter to the input. Forget about the filter coefficients! You only need to know the filter type (minimum-delay or zero-phase). For all frequencies lower than one-quarter of the sampling rate, (that is, one-half of the Nyquist bandwith) you may assume that the response is flat and the phase: - of a zero-phase filter is zero - of a minimum-delay filter represents a constant delay whose magnitude you can experimentally determine by recording a time signal (such as from the pps output of a GPS receiver). At low frequencies, even a minimum-delay filter is nearly linear-phase (but not zero-phase). - You should also check if the delay of a zero-phase filter is really zero. There might be an error in the time-tag. Calibration of Digitizers

The term „minimum phase“ was coined with respect to a Fourier transformation with exp(j  t) in the forward transformation. Most seismologists use however exp(-j  t). Then the signal with the smallest possible delay – the minimum-delay signal – has, mathematically speaking, the largest possible (although negative) phase. The unambiguous term „minimum-delay“ is preferable to the term „minimum-phase“. „Minimum phase“ is normally maximum phase