Guidelines for Prevention of TB Centers for Disease Control & Prevention.

Slides:



Advertisements
Similar presentations
Purpose of 2005 Guidelines Update and replace 1994 Mycobacterium tuberculosis infection control (IC) guidelines Further reduce threat to health-care workers.
Advertisements

HVAC Systems and Their Role in Infection Control and Prevention
PowerPoint ® Presentation Chapter 14 Homeland Security Homeland Security Building Layout Specific CBR Attack Prevention Recommendations Securing Outdoor-
BSA Health System, May 2009 Next Slide Previous Slide BSA HEALTH SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All.
Airflow and BSC Biosafety and Biosecurity Awareness Training
Infection Control.
Respiratory Protection
Disease Transmission Good morning..
Innovative Air Distribution for Healthcare Facilities.
The Care and Isolation Unit (CIU) at St Patrick Hospital In 2005 the NIH issued a Request for Proposals for the construction and staffing of a patient.
Infection Control for SARS. How is SARS spread? MOST OFTEN spread by contact and or droplet –That is, touching a patient or their secretions directly.
Unit 6.3. Ultraviolet germicidal irradiation (UVGI) TB Infection Control Training for Managers at National and Subnational Level.
Overview of Enforcement for Occupational Exposure to Tuberculosis (TB)
Unit 6.2. Mechanical and mixed mode ventilation TB Infection Control Training for Managers at National and Subnational Level.
Fire Prevention and Safety Health Science Class. Rationale: Fires may occur at any time, as a result of overloading wiring, smoking, improper chemical.
Ebola Facts October 15, 2014.
EnvironmentalSafety 2.01 Understand safety procedures 1.
Personal Protective Equipment May, Learning Objectives Demonstrate knowledge of the principles of infection control Recognize gaps in infection.
1 Novel Influenza A H1N1 Outbreak: The Florida Response Infection Control Considerations: Focus on Personal Protective Equipment.
Unit 4: Infection Control and Prevention of Tuberculosis
TB Infection Control: Engineering (Environmental) Controls Kevin P. Fennelly, MD, MPH Division of Pulmonary & Critical Care Medicine Center for Emerging.
 Lesson objective to understand the importance of hospital and care setting hygiene.
1 Ventilation, Temps and Humidity Requirements PO Box 3187 Charleston, WV Inquisit February 6, 2014.
Indoor Firing Ranges Training Education Recommended Practices.
Personal Protective Equipment
IC AND EBOLA. ComponentRecommendation Patient Placement Single patient room (containing a private bathroom) with the door closed Facilities should maintain.
SARS Infection Control. Key Objectives Early detection Containment of infection Protection of personnel and the environment of care Hand hygiene Key Strategies.
Unit 6.4. Filtration TB Infection Control Training for Managers at National and Subnational Level.
Eliminating and Controlling Dust & Noise Hazards July 2002.
HVACR311 – Electrical for Refrigeration International Mechanical Code Relating to Refrigeration.
sss Employee Health sss
The Effects of Construction Activity on Indoor Air Quality for Hospitals Presented by: Tom N. Petersen, P.E. Environmental and Engineering Solutions, Inc.
Pan American Health Organization.. Protecting the Health of Health Care Workers: Experience from the Americas Marie-Claude Lavoie Decision Making for Using.
Waste Anesthetic Gases. The anesthetic gas and vapors that leak out into the surrounding room during medical and surgical procedures are considered waste.
Key elements of an ECP: 1.Statement of Purpose 2.Responsibilities 3.Risk Identification and Risk Assessment 4.Risk Control Measures 5.Education and Training.
A NIOSH Approach to a TB Outbreak Tuberculosis in Elephants: Science, Myth and Beyond Kansas City, MO April 5-6, 2011 Todd Niemeier, MS, CIH National Institute.
The Physical Environment Tracers How Should I Prepare for the Physical Environment Tracers? Healthcare Engineering Consultants  Will limit.
MEDICAL EQUIPMENT AND UTILITES MANAGEMENT Louis Stokes Cleveland, Department of Veterans Affairs Medical Center JCAHO Environment of Care Series Fiscal.
Guidance for the Selection and Use of Facemasks and Respirators Materials referenced from CDC, FDA, NIOSH and OSHA.
HVACR416 - Design IAQ / Ventilation / Pathways. Ventilation Most air handling units distribute a mix of outdoor air and re-circulated indoor air. Some.
SARS: Protecting Workers. OSHA Guidance for Employers on Severe Acute Respiratory Syndrome (SARS) Potentially deadly respiratory disease Potentially deadly.
12/12/ |1 | اداره كنترل سل و جذام نشست سالانه برنامه كنترل سل مازندران - بابلسر.
SARS: Protecting Workers. OSHA Guidance for Employers on Severe Acute Respiratory Syndrome (SARS) Potentially deadly respiratory disease Potentially deadly.
Fire Safety Month Fire Safety Tips for October Department of Risk Management James Madison University.
Renovation and Infection Control. Construction activity n Type A:inspection, non-invasive n Type B:small scale, short duration, minimal dust- generating.
Improving Tuberculosis Infection Control
AIA Guidelines for Design and Construction of Hospital and Healthcare Facilities Presented By: Michael A. Rogers, PE
Fires need 3 Things To Start Oxygen (Air) Fuel (any material that will burn) Heat (sparks, matches, flames)
EBOLA VIRUS DISEASE PREPAREDNESS Screening, Detection & Planning.
STANDARD PRECAUTION Prof. Dr. Ida Parwati, PhD.
STANDARD 6.0 The student will analyze the existing and potential hazards to clients, co-workers, and self and will prevent injury or illness through safe.
FIRES NEED 3 THINGS TO START Oxygen (Air) Fuel (any material that will burn) Heat (sparks, matches, flames)
Standard and Transmission-Based Precautions
TB Prevention and Control in Correctional and Detention Facilities Mark Lobato, MD Division of TB Elimination Centers for Disease Control and Prevention.
Control of Airborne Respirable Dust Hazards: A Training Program for Underground Coal Miners The Penn State Miner Training Program University Park, PA
Laboratories and Hospitals Which Way is the Air Blowing? Presented by: Douglas Wrenn – CCM, QCxP, CXCP, LEED ap.
HEALTHCARE SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All workers engaged in the construction, renovation, repair,
1 SARS – Clearing the Air Jerome J Schentag, PharmD University at Buffalo FailSafe Air Safety Systems Corp
“Ventilation of Healthcare Facilities” Impact of the New ANSI/ASHRAE/ASHE Standard 170 Standard 170 Stephen W. Nicholas, CPMM, CAFS ASHRAE Boston Chapter.
SAFETY, SECURITY, AND EMERGENCY PLANS IN THE MEDICAL OFFICE Chapter 10, Unit 1.
Mintie Technologies, Inc. ECU Product Introduction and Demo/Training Virginia Presentation.
PRESENTED BY ENG. PRISCILLA NAKIBONEKA SANITARY ENGINEER, MINISTRY OF HEALTH, UGANDA.
Prevention and Control of Influenza A (H1N1) in the Workplace Engr. Nelia G. Granadillos Chief, Environment Control Division Occupational Safety and Health.
Management of Surgical Smoke Tool Kit Part III: An Overview of the Health Care Regulations, Standards, and Guidelines Related to Surgical Smoke.
Pandemic Influenza Planning
Topics Personal Protective Equipment
Employee/ Occupational Health
Ebola Facts October 15, 2014.
Biosafety Principles: Separation, Seclusion & Containment
University of Washington
Presentation transcript:

Guidelines for Prevention of TB Centers for Disease Control & Prevention

Administrative Controls  Infection Control Policies and Procedures  Risk Assessment/HCW Screening  Investigation of HCW TST Conversions

TB Infection Control Policies & Procedures 1  High index of suspicion for TB  Prompt triage  Prompt initiation of respiratory isolation AII room under negative pressure (monitored) AII room under negative pressure (monitored) UVGI and HEPA filtration as necessary UVGI and HEPA filtration as necessary Limit movement of patient outside AII room Limit movement of patient outside AII room  Prompt initiation of appropriate treatment

TB Infection Control Policies & Procedures 2  Personal respiratory protection during exposure (N- 95 respirators)**fit testing req.  Limit employee and visitor exposure  Monitor clinical status by symptoms, laboratory and CXR to ensure appropriate duration of airborne precautions  Appropriate discharge to the community

Respiratory Protection  The ability to filter 1um in size with a filter efficiency of >95%  Fit test to insure face seal leakage of <10%  Making respirators available in at least three sizes  Reuse of Respirators

Why do we place patients in isolation?  Patients who are immunocompromised are placed in a “protective environment”  Patients who have communicable diseases are placed in “airborne infection isolation”(AII)  Patients who have both problems are put in a room with a combination of controls but always protect the staff, visitors and other patients

Protective Environment

 Install central or point-of-use HEPA filters for incoming air  Maintain > 12 air changes per hour (ACH)  Maintain positive pressure (> 2.5 Pa) in relation to corridor  Ensure that rooms are well sealed Properly constructed windows, doors and intake and exhaust ports Properly constructed windows, doors and intake and exhaust ports Maintain ceilings that are smooth and free of fissures, open joints and crevices Maintain ceilings that are smooth and free of fissures, open joints and crevices Monitor for leakage Monitor for leakage

Airborne Spread of Smallpox in the Meschede Hospital Fenner Fig. 4.9

AII Rooms

 Maintain continuous negative pressure (2.5 Pa) in relation to the air pressure in the corridor and ensure monitoring  Ensure that rooms are well sealed  Provide ventilation to ensure > 12 ACH for new and renovated rooms and > 6 ACH for existing rooms  Direct exhaust air to the outside, away from air intake and populated areas. If this is not practical, air from the room can be recirculated after passing through a HEPA filter, ?UVGI

Guidelines  2001 AIA “Guidelines for Design and Construction of Hospital and Health Care Facilities - ????NEW July 2006  2003 CDC “Guidelines for Environmental Infection Control in Health-Care Facilities”  2004 JCAHO “Environment of Care – Essentials for Health Care” Fourth Edition

AIA Guidelines Section: 7.2.C Airborne Infectious Isolation Rooms does not require anterooms. The requirement for an anteroom was dropped in the edition of the Guidelines on the basis of a study. CDC Guideline: Does not require anteroom. For Viral Hemorrhagic Fever and Smallpox, use AII preferably with an anteroom – if not available use industrial-grade HEPA filters to provide additional ACH JCAHO EC Standard: No reference to anterooms What about an anteroom?

ASHRAE’s Design Manual (American Society of Heating, Refrigeration, and Air-conditioning Engineers) “HVAC Design Manual for Hospitals and Clinics” 2003

Chapter 12: Room Design On negative air pressure, as is required for Airborne Infectious Isolation Rooms: “…Through dilution, a 500 cubic feet anteroom (for example) with an AVM of 50 cubic feet would experience a 90 percent reduction in the transmission of contaminated air to and from the isolation room. An anteroom is recommended as a means of controlling airborne contaminant concentration via containment and dilution of the migrating air.”

Why add an anteroom or airlock?  To provide a barrier against loss of pressurization, and against entry/exit of contaminated air into/out of isolation room when the door to the airlock is opened  To provide a controlled environment in which protective garments can be donned without contamination before entry into and exit out of room  To provide a controlled environment in which equipment and supplies can be transferred fro the isolation room without contaminating the surrounding area

Anterooms

Creating Isolation Rooms  Funding by governmental agencies to increase isolation capacity  Many healthcare facilities have upgraded or retrofitted existing negative pressure isolation rooms  Many healthcare facilities have purchased “quick fixes” to increase isolation capacity

What’s out there? Source Control – Local Exhaust/Ventilation

What’s out there? Source Control – Local Exhaust/Ventilation

Disclaimer  Following are illustrations of actual products available to healthcare facilities. These are being used for educational purposes only and are not meant to endorse or criticize any individual company or product. I have no financial interest in any healthcare products.

What’s out there?

Key Points  There needs to be a clear understanding by all of our goals when using isolation rooms – who are we trying to protect and why.  There needs to be a clear understanding of how to appropriately use the equipment/resources available to accomplish our goals.  There needs to be a clear understanding of how to minimize risks and maximize benefits to patients and health care workers by using the equipment/resources.

Key Points  A portable HEPA device will not create a negative pressure room unless exhaust can be discharged directly to the outside.  Trying to connect a HEPA unit into a return duct to create negative pressure would pressurize the return duct and result in blowback into adjacent rooms.  If the unit is vented directly to the outside, return air grilles must be sealed off – remember to take into account the direction of flow into the attached bathroom.

Key Points  All personnel must understand the use of these devices – housekeeping, nursing.  The portable air filtration device should not be plugged into a power strip or extension cord. Consider using an emergency power outlet.  The HEPA unit must not create an obstruction that would interfere with the proper delivery of health care.  The placement of the device needs to be pre- determined to maximize air mixing for better air scrubbing.

Key Points  The intake of the device should be placed as close to the suspected source of contamination.  The device should be placed so that it does not draw contaminated air past the breathing zone of the caregiver.  The air flowing out of the device must not be directed in a way that would cause discomfort to patients, visitors and staff.

Key Points  The air flow needs to be appropriate for the size of the room to give the desired air exchanges per hour. Consider a locked panel to prevent a change in the air flow controls.  Rooms in which the devices may be utilized should be chosen beforehand ensuring that the noise created is not disruptive to others.  If the unit is ducted to the outside or into the existing ventilation system, ensure that an appropriately fitting interface is available.

Key Points  Place HEPA filters over exhaust grilles that cannot be blocked.  The use of the portable filtration devices should be guided by a written policy that is facility- specific with appropriate reviews and approvals from infection control, administration, clinical and facility engineering and the departments in which the units will be used.  Healthcare facilities should have a checklist establishing the proper room use.

Key Points  Based on manufacturer’s recommendation and any additional suggested protocol from facility maintenance, a standard routine maintenance procedure should be developed for the unit. This should include: Changing of pre-filters. Be sure to include details of PPE and proper disposal of filters. Changing of pre-filters. Be sure to include details of PPE and proper disposal of filters. Operational check for proper operation. Operational check for proper operation. Interior cleaning of the unit Interior cleaning of the unit Changing of UV lamp Changing of UV lamp General electrical and mechanical safety check General electrical and mechanical safety check

Key Points  Clinical and/or facility engineering should check the machine on a daily basis while in use and measure the degree of negative pressure between the room in which it is situated and adjacent/affected areas.

Key Points  The HEPA device must be leak tested and certified. This should be done initially when the equipment is received, at least annually thereafter, and every time the HEPA filter is changed. The frequency of changing the HEPA filter should be based upon manufacturer’s recommendation.

Key Points  Policies and procedures should specify recommended PPE when performing maintenance of the unit.  Maintenance should be performed in an area away from patient care.

Monitoring Negative Air Pressure  Pressure-measuring devices Measure pressure at the bottom of the door Measure pressure at the bottom of the door Audible warning with a time delay Audible warning with a time delay Check continuous monitoring devices at least monthly using smoke tubes Check continuous monitoring devices at least monthly using smoke tubes

Smoke Test  Checked daily  Hold 2 inches from bottom of door  If room air cleaners are used they should be running  Door must be closed

UV Radiation  Used to supplement other engineering controls  Duct Irradiation To recirculate air from an isolation room back into the room. To recirculate air from an isolation room back into the room. Used in general use areas where air is recirculated back into general ventilation Used in general use areas where air is recirculated back into general ventilation  Upper Room Air Irradiation Mounted on ceiling or wall Mounted on ceiling or wall

Effectiveness of UV Systems  Intensity of UVGI  Duration of contact  Relative humidity

UV Safety Issues  Short Term Exposure  Education  Labeling  Maintenance  Monitoring

Operating Room  Place bacterial filter on patient endotracheal tube patient endotracheal tube Expiratory side of breathing circuit of a Expiratory side of breathing circuit of a VentilatorVentilator Anesthesia equipmentAnesthesia equipment  No anterooms Keep doors closed Keep doors closed Control traffic Control traffic If possible schedule case at end of day If possible schedule case at end of day

Postoperative recovery  Private room  Negative air pressure

Autopsy rooms  Negative air Pressure 12 ACH 12 ACH Increase ventilation if possible using HEPA – filtered air or UVGI recirculation systems Increase ventilation if possible using HEPA – filtered air or UVGI recirculation systems  Exhausted directly to outside  Respiratory protection