M. Gilchriese Evaporative Cooling Tests of Pixel Disk Sectors June 2000 E. Anderssen, M. Gilchriese, F. Goozen, F. McCormack, J. Taylor, T. Weber, J. Wirth.

Slides:



Advertisements
Similar presentations
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Advertisements

Basic Refrigeration Cycle
ATLAS Frame PRR 1 W.O. Miller Feb US ATLAS Pixel Detector Global Supports PRR W.O. Miller, R. Smith, W.K. Miller, R. Baer HYTEC G. Gilchriese, E.
Thermal Analysis of short bake out jacket version 1 12-Nov-2013.
Outer Stave Prototype Update E. Anderssen, M. Cepeda, M. Garcia-Sciveres, M. Gilchriese, N. Hartman, J. Silber LBNL W. Miller, W. Shih Allcomp, Inc ATLAS.
GTK Cooling Summary of frame and cooling plate Shear tests Alessandro Mapelli Michel Morel Jerome Noel Georg Nüßle Paolo Petagna Giulia Romagnoli GigaTracKer.
M. Gilchriese Mechanics Labor and Disk Sectors US Pixel Meeting November 2001.
Pixel Upgrade Local Supports Based on Thermally Conducting Carbon Foam E. Anderssen, M. Cepeda, S. Dardin, M. Garcia-Sciveres, M. Gilchriese, N. Hartman,
M. Gilchriese Disk Rings and Assembly M. G. D. Gilchriese Lawrence Berkeley National Laboratory April 2000.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
M. Gilchriese Status Report Sectors, Rings, Frame December 2002.
13th April 2005R.Bates, QM Measurements of Barrel and EC HEX R. Bates, M. Olcese, B. Gorski, QM for prototype builds.
1 Calorimeter Thermal Analysis with Increased Heat Loads September 28, 2009.
ATLAS Pixel Detector Cooling Connections Testing and Development: Progress Report September 28, 2000 N. Hartman, E. Anderssen, M. Gilchriese, T. Weber,
Dogleg Thermal Tests : Configuration 7 6 AiN plate side Jan SM+LB 8 Dogleg side Heater (0.4W) flow 2 Temperature sensors located.
Calorimeter Analysis Tasks, July 2014 Revision B January 22, 2015.
1 VI Single-wall Beam Pipe tests M.OlceseJ.Thadome (with the help of beam pipe group and Michel Bosteels’ cooling group) TMB July 18th 2002.
Ron Madaras, LBL U.S. Pixel Meeting, SCIPP, July 9-10, 2003 Patch Panel 1 (PP1) Brief Review Cost and Effort Estimate.
1 THERMAL CONDUCTIVITY OF SILICATE BONDED SAMPLES Status of measurements with the thermal conductivity facility in Firenze June, 7 th 2007.
CRYOGENICS FOR MLC Cryogenic Cooldown Scheme Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
Back up stave test program status Eric VIGEOLAS Pixel week December 2000 Pre production status Assembling phase comments Geometrical control Stave Qualification.
M. Gilchriese SLHC Pixel Local Supports Based on Thermally Conducting Carbon Foam E. Anderssen, M. Cepeda, S. Dardin, M. Garcia-Sciveres, M. Gilchriese,
20 th June 20111Enrico Da Riva, V. Rao Project Request and Geometry constraints June 20 th 2011 Bdg 298 Enrico Da Riva,Vinod Singh Rao CFD GTK.
M. Gilchriese - November 12, 1998 Status Report on Outer Support Frame W. Miller Hytec, Inc E. Anderssen, D. Bintinger, M. Gilchriese LBNL.
1 US Pixel Mechanics Role Global support structureIntermediate support structureLocal support structure Stave SectorDisk Barrel x (9-11) x5 x (22,40,56)
CRYOGENICS FOR MLC Cryogenic Piping in the Module Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
M. Gilchriese Module Assembly and Attachment at LBNL M. Gilchriese for F. Goozen April 2000.
Update on UT cooling specifications and status of activities LHCb CO2 cooling meeting 8/7/2015 Simone Coelli For the Milano UT group INFN milano 1 Istituto.
M. Gilchriese Disk Sectors M. G. D. Gilchriese Lawrence Berkeley National Laboratory April 2000.
M. Gilchriese Sectors, Rings, Frame Assembly and Installation July 18.
ATLAS Pixel Detector February 2002 Cooling Services Connections N. Hartman LBNL Cooling Connections Status Report: LBNL Effort February, 2002 N. Hartman,
CMS FPIX Cooling System Studies Joe Howell, Fermilab for the FPIX Upgrade Mechanical Working Group CMS Upgrade Workshop April 27,
ATLAS Pixel Detector Cooling Connections Testing and Development: Progress Report April 26, 2001 N. Hartman, E. Anderssen, M. Gilchriese, F. Goozen, T.
M. Gilchriese U.S. Pixel Mechanics Overview M. G. D. Gilchriese Lawrence Berkeley National Laboratory April 2000.
M. Gilchriese Disk Sector Production Pixel Local Supports Production Readiness Review.
Urban Storm Drain Design: Multiple Pumps. Multiple Pumps The HDM and FHWA recommend more than one pump Redundancy Flexibility Ability to manage flows.
DOE/NSF Review of U.S. ATLAS /March 2001 WBS Pixel Overview and WBS Pixel Mechanics M. G. D. Gilchriese Lawrence Berkeley Laboratory.
1 VI Single-wall Beam Pipe Option: status and plans M.Olcese TMB June 6th 2002.
SEPTEMBER 2002 Pixel Support Tube A. Smith LBNL 1 ATLAS Pixel Detector Heater Panel Testing Alexis Smith September 17, 2002.
M. Gilchriese Thermal Shock. M. Gilchriese 2 Thermal Shock - Sector 9 Use liquid nitrogen vapor to cool sector rapidly. Setup is just dewar, valve and.
Removal of 3 He from 4 He (R&D) David Haase, Franklin Dubose, Travis McCaw and Paul Huffman North Carolina State University.
1 Monophase Measurements on Prototype Pixel Structures D. Bintinger, M. Gilchriese, J. Taylor and J. Wirth and contributions from D. Cragg, E. Perrin and.
M. Gomez Marzoa1 WG4 Meeting - 12th December 2012 Update on stave thermal testing Claudio BORTOLIN Enrico DA RIVA Corrado GARGIULO Manuel GOMEZ MARZOA.
Pixel Upgrade Carbon Foam and Outer Stave Update E. Anderssen, M. Cepeda, M. Garcia-Sciveres, M. Gilchriese, T. Johnson, J. Silber Lawrence Berkelely National.
Update on Micro Channel Cooling Collaboration Meeting , G. Nüßle.
M. Gilchriese Disk Sector Status E. Anderssen, M. Gilchriese, F. Goozen, N. Hartman, T. Johnson, J. Wirth October 11, 2001.
M. Gilchriese - December 2000 Disk Sector Status E. Anderssen, M. Gilchriese, F. Goozen, N. Hartman, T. Johnson, F. McCormack, J. Wirth and D. Uken Lawrence.
Walter Sondheim 6/9/20081 DOE – Review of VTX upgrade detector for PHENIX Mechanics: Walter Sondheim - LANL.
Phase 1 FPix Cooling Tube Testing Erik Voirin, C.M. Lei, Harry Cheung, Stefan Gruenendahl (FNAL) Kirk Arndt, Qiuguang Liu (Purdue) Phase 1 FPIX cooling.
Report on testing Snake2 u-channel. P. Jalocha & J. Buytaert. 8 June 2015.
Multi-Microhannel Cooling Model Silicon Micro-Cooling Element to be applied on a pixel detector of CERN (ALICE) / Parametric Study Footprint area: (6.0.
M. Gilchriese - September 2000 Pixel Insertable Layouts September 2000.
Cooling Test Results on fuzzy carbon substrate Setup in Lotima Room Used water/glycol mix (70/30 by wt) Neslab chiller to set temp Small pump to get the.
ATLAS Pixel Detector December 2001 Cooling Services Connections N. Hartman LBNL Cooling Connections Status Report: LBNL Effort December, 2001 N. Hartman,
1 Disk Sectors Integrated support and cooling for disk modules. Each sector has 6 modules Number of sectors is 2x9+4x8=50. Fabrication of all sectors in.
RFQ Cooling Schemes and Instrumentation PXIE RFQ Fabrication Readiness Review LBNL – June 26, 2013 Andrew Lambert - Engineering Division Lawrence Berkeley.
7 February 2012 Annekathrin Frankenberger (HEPHY Vienna) Open CO 2 Cooling System at the beam test Belle II SVD-PXD Meeting.
M. Gilchriese - February 2001 Disk Sector Status E. Anderssen, M. Gilchriese, F. Goozen, N. Hartman, T. Johnson, F. McCormack, J. Taylor, T. Weber, J.
2016/12/6 Yasuhiro R&D status of a gas-compressor based 2-phase CO2 cooling system for FPCCD vertex detector 2016/12/6 Yasuhiro Sugimoto.
DESIGN OF SHELL AND TUBE HEAT EXCHANGER
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
FPix Cooling Circuit. FPix Cooling Circuit FPix Shared HD - Nominal Flow ΔPtotal = 5bar Δm = 0.5g/s mnominal = 2.6g/s ΔPtotal = 10bar Δm = 0.2g/s mnominal.
Pixel cooling specifications
ALICE PD group meeting Andrea Francescon.
WG4 – Progress report R. Santoro and A. Tauro.
Ultra-light carbon fiber structures: evaporative tests
Pixel CO2 Cooling Status
FREE CONVECTION – FIXED POWER TD1005
Tests on a dummy facet of PIX upgrade using CO2 cooling
P M V Subbarao Professor Mechanical Engineering Department I I T Delhi
Presentation transcript:

M. Gilchriese Evaporative Cooling Tests of Pixel Disk Sectors June 2000 E. Anderssen, M. Gilchriese, F. Goozen, F. McCormack, J. Taylor, T. Weber, J. Wirth Lawrence Berkeley National Laboratory W. K. Miller, W. O. Miller HYTEC, Inc. G. Hallewell Rutherford Appleton Laboratory V. Vacek Czech Technical University of Prague

M. Gilchriese Outline Background info on evaporative cooling What was tested Infrared thermography before evaporative tests Results of evaporative tests –Aluminum-tube sectors –Sealed-tube(HYTEC) sectors Conclusions

M. Gilchriese Evaporative Cooling Background Will not describe evaporative cooling setup here. Include basic charts for C 3 F 8 for reference.

M. Gilchriese Pressure vs Temperature for C 3 F 8

M. Gilchriese What Was Tested Four aluminum-tube sectors. Prototypes # –All had about 0.43 mm thick carbon-carbon faceplates manufactured by ALLCOMP, Inc. These plates were also used for the fabrication of the second prototype support ring by HYTEC and ALLCOMP. The center “drop outs” were used to make the sectors. –The plates were impregnated with cyanate ester, which left a surface layer approximately 25 microns thick. This resin layer was removed by scrubbing on prototype #10. –Prototypes #7 and #8 have aluminum tubes that have interior dimensions of 1.69 x 4.06 mm, the smaller dimension setting the thickness of the sector. The hydraulic diameter is 2.4 mm –Prototypes #9 and #10 have tubes that are 2.74x4.19 mm. The hydraulic diameter is 3.3 mm. –The tubes for #7 and #8 were black anodized. The tubes for #9 and #10 were not - lack of time to meet test schedule. Sealed-tube(HYTEC) sector –Prototype #4 was tested. This had 0.5 mm faceplates, a double-wall sealed carbon-carbon tube and an hydraulic diameter of 3.2 mm.

M. Gilchriese Test Setup This shows the four aluminum-tube sectors. There are two pairs, running the pair in series. Two valves allow running each pair separately or running both pairs in parallel. Sectors #9 and #10 were removed and replaced by the HYTEC sector during the test program.

M. Gilchriese Aluminum-tube Prototype Sectors Capillary(0.030” ID 1.2 m long) Exhaust lines

M. Gilchriese Sectors in Box in Freezer Box with sectors put in freezer to provide ambient temperature of about -12C. RTDs read out via “Prague system” by V. Vacek. Pressure sensors same. Flow not recorded by computer. Precooling set point not recorded by computer. Computer data recorded every sec(typical 10 seconds but varied during test program).

M. Gilchriese IR Thermography Infrared thermography was performed at LBNL on sectors using room temperature(20-21 o C) water coolant before making measurements with the evaporative system at CERN. This was done, in part, to correlate the discrete- point measurement done at CERN with the IR measurements. The set up is shown below and the results for all sectors shown on the next pages.

M. Gilchriese RTD Locations

M. Gilchriese Aluminum-Tube #7 FrontBack

M. Gilchriese Aluminum-Tube #8 FrontBack

M. Gilchriese Aluminum-Tube #9 FrontBack

M. Gilchriese Aluminum-Tube #10 FrontBack

M. Gilchriese HYTEC #4 FrontBack Backside of HYTEC #4 was not imaged yet.

M. Gilchriese Data Recorded Data were recorded about every 10 seconds, usually. Sometimes 2 sec or 30 seconds. –Ambient temperature in freezer at two locations –Exhaust/return pressure, which sets the exit temperature –Pressure differential across sector pair or single sector. –Inlet fluid temperature before capillary(0.030” capillary was used for all tests). –Outlet fluid temperature –Temperature at top of long vertical glass column in cooling lab. –RTD readings on sectors Data recorded by hand in logbook –Power settings. Typically 50W per sector but sometimes more. Power always refers to power per sector. –Flow rate of fluid. –Set point for precooling

M. Gilchriese Test Program June 16 –Sectors 7 and 8 tested –Sectors 9 and 10 tested –Sectors 7+8 and sectors 9+10 tested in parallel(one fluid inlet, two capillaries, one for each pair of sectors) June 17 –Remove 9 and 10 and replace with HYTEC #4. Purge system. June 18 –Day off June 19 –HYTEC test –7+8 on/off –7+8 power margin –simulate 3 in series –change precool to +18

M. Gilchriese (lbl_05) Sectors 7 and 8 Summary

M. Gilchriese (lbl_06) Sectors 9 and 10 Summary

M. Gilchriese (lbl_07) 7+8 in Parallel with 9+10

M. Gilchriese (lbl_05)Sectors Silicon T Only Flow =1.2 gm/sec Exhaust P=2.13 bar DP=0.16 bar 60W 50W No power

M. Gilchriese (lbl_06)Sectors Silicon T Only No power 50 Watts 60 Watts Flow 1.2 gm/sec Exhaust P= bar DP=0.09 bar

M. Gilchriese (lbl_07)Sectors7+8 and 9+10 in Parallel Spikes casued by hand setting of power - overshoot

M. Gilchriese (lbl_08) HYTEC Sector#4 - Silicon Only

M. Gilchriese (lbl_10) Sectors On/Off Tests

M. Gilchriese (lbl_10)Sectors7+8

M. Gilchriese (lbl_11)Sectors 7+8 at 50W - Stability Flow =1.2 gm/sec Exhaust pressure=2.09 bar absolute DP=0.155 bar

M. Gilchriese (lbl_12)Sector Power Margin

M. Gilchriese (lbl_14)Simulate 3 Sectors in Series

M. Gilchriese (lbl_15)Simulate 3 in series - 2 sec scale

M. Gilchriese (lbl_16)Simulate 3 in series - 30 sec scale - stability

M. Gilchriese (lbl_17)Rm. Temp Precool

M. Gilchriese Conclusions The current thermal requirement of keeping the silicon temperature at or below -6 o C can be met comfortably at the nominal 50W maximum power running two aluminum-tube sectors in series with the smaller(2.4 mm) of the hydraulic diameters tested. There is no reason to use a larger hydraulic diameter. –The measured temperature uniformity of prototypes 7 and 8 in series at 50W is about 4 o C using RTDs located at the center of the dummy heaters(lbl_11 data set) using precooled liquid. To this needs to be added about 2 O C based on the IR thermography to account for spread within heater. This is well within spec. –There is considerable margin in the system if the power were to increase beyond 50W per sector, running two sectors in series(lbl_12 data set) also with precooled liquid. –Operation without precooled liquid was also demonstrated(lbl_17 data set), but appears to require somewhat higher flow, thus slightly higher pressure drop and about 5 o C +2 o C uniformity. The operating power margin beyond 50W appears slightly reduced compared to precooled liquid but these tests should be repeated. Operation of the 3 al-tube sectors in series at 50W each appears feasible, and was simulated by increasing the total power on two sectors to 150W. The temperature uniformity of the silicon across all three sectors could be about 10 o C, but might be worse - depends on individual sector performance and location relative to exhaust, which sets the temperature. The HYTEC prototype #4 was operated successfully but the non-uniformity of the current design(tube location) would make it difficult to meet the current -6 o C spec in all silicon locations unless the exhaust temperature is about -30 o C.

M. Gilchriese Implications for Cooling Work Plan In the case of the aluminum-tube sectors, proceed with 2.4 mm hydraulic diameter as the baseline. For HYTEC sectors, stay with current hydraulic diameter but understand timescale for tube redesign to obtain better temperature uniformity. For either option, plan tests for December timescale that would compare directly operation of 3 sectors in series with 2 sectors in series –These tests should be done on prototypes as close as possible to the final designs –Should include more advanced prototypes of cooling connections, again as close as possible to what would be used in the experiment. This means both local connections on sector and simulated piping to end of pixel region, and perhaps beyond. Some improvements in instrumentation/measurements –Computer record flow, precool conditions. –Improve measurements of inlet fluid(after capillary) and exhaust fluid temperatures. –Make more systematic study of temperature, pressure, flow…so that predictive model can be made. Measurements this time were too few to do this.