Precision AC Current Measurement Technique Guildline Instruments Limited.

Slides:



Advertisements
Similar presentations
Copyright 2001, Agrawal & BushnellVLSI Test: Lecture 181 Lecture 18 DSP-Based Analog Circuit Testing  Definitions  Unit Test Period (UTP)  Correlation.
Advertisements

Transformer Coupling.
A design technique of ARCP matrix converter using circuit simulator Nagasaki University Yuichiro Nakazawa.
Multiplexed vs. Simultaneous Data Acquisition Using USB Devices Presented by: Rene Messier Company: Data Translation Company: Data Translation.
Chapter 12 RL Circuits.
Measurement of Voltages and Currents
CORRECTING RMS VALUE OF A SINE WAVEFORM SAMPLED DUE LIMITED NUMBER OF PERIODS AND DETERMINATE APERTURE TIME ON DMM Keywords: Digital Multimeter (DMM),
This lesson covers the following outcomes Unit 54 P1, P7, P8 Unit 6 P10, P11.
Potentiostat Basics I’m Max Yaffe
Lecture 9: D/A and A/D Converters
1. Output signal alternates between on and off within specified period Controls power received by a device The voltage seen by the load is directly proportional.
Sampling and quantization Seminary 2. Problem 2.1 Typical errors in reconstruction: Leaking and aliasing We have a transmission system with f s =8 kHz.
1 Fully Digital HF Radios Phil Harman VK6APH Dayton Hamvention – 17 th May 2008.
Application of the SIDECAR ASIC as the Detector Controller for ACS and the JWST Near-IR Instruments Markus Loose STScI Calibration Workshop July 22, 2010.
Lecture 101 Introduction to Energy Storage Elements: The Capacitor.
ECE 333 Renewable Energy Systems Lecture 13: Per Unit, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
ECE 201 Circuit Theory I1 Sinusoidal response of circuits The switch is closed at t = 0. Determine the current i(t) for t >= 0. i(t)
Digital to Analog Converters
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Fall 2008 Physics 121 Practice Problem Solutions 13 Electromagnetic Oscillations AC Circuits Contents: 121P13 - 2P, 3P, 9P, 33P, 34P, 36P, 49P, 51P, 60P,
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Stability Workshop April , 2007 NSLS-II Electrical Systems G. Ganetis NSLS-II Electrical Systems NSLS-II.
Inputs to Signal Generation.vi: -Initial Distance (m) -Velocity (m/s) -Chirp Duration (s) -Sampling Info (Sampling Frequency, Window Size) -Original Signal.
Introduction to Frequency Selective Circuits
AC Circuits (Chapt 33) circuits in which the currents vary in time
Analogue Electronics II EMT 212/4
/1 Testing Harmonics and Flicker /1 Harmonics & Flicker Two different test standards: EN & EN EN controls.
AC Waveform and AC Circuit Theory Md Shahabul Alam Dept: EEE.
Ni.com Data Analysis: Time and Frequency Domain. ni.com Typical Data Acquisition System.
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
Alternating Current Circuits
Chapter 33 Alternating Current Circuits CHAPTER OUTLINE 33.1 AC Sources 33.2 Resistors in an AC Circuit 33.3 Inductors in an AC Circuit 33.4 Capacitors.
Lecture 1 Signals in the Time and Frequency Domains
Announcements Assignment 5 due tomorrow (or now)
Solid State Electricity Metrology
Understanding ADC Specifications September Definition of Terms 000 Analogue Input Voltage Digital Output Code FS1/2.
ALTERNATING CURRENT METERS
Section 2 AC Circuits. Chapter 12 Alternating Current.
1/38 Passive components and circuits - CCP Lecture 5.
POWER QUALITY.
 Voltage can be produced such that, over time, it follows the shape of a sine wave  The magnitude of the voltage continually changes.  Polarity may.
Sanna Taking & Mohamad Nazri Abdul Halif School of Microelectronic Engineering Prepared by ALTERNATING CURRENT METERS Part 2 Syarifah Norfaezah Edited.
Phasors and Kirchhoff’s Current Law
Lecture 6: Measurements of Inductance, Capacitance, Phase, and Frequency 1.
Intro to Pre-Electrical Engineering The fundamentals of electricity and electrical science 1.
Digital to Analog Converter (DAC)
APPLICATION OF A WAVELET-BASED RECEIVER FOR THE COHERENT DETECTION OF FSK SIGNALS Dr. Robert Barsanti, Charles Lehman SSST March 2008, University of New.
BASIC INSTRUMENTS - oscilloscopes
1 Lecture #6 EGR 272 – Circuit Theory II Read: Chapter 9 and Appendix B in Electric Circuits, 6 th Edition by Nilsson Using Phasors to Add Sinusoids Sinusoidal.
1 Eeng224 Chapter 10 Sinusoidal Steady State Analysis Huseyin Bilgekul Eeng224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern.
Diode rectifiers (uncontrolled rectifiers)
TECHNICAL PAPER ON SIMULTANEOUS AC-DC POWER TRANSMISSION
Advances in High Current and Resistance Measurements to 11,000 Amps and Higher Guildline Instruments Limited.
AC Current An AC circuit consists of a combination of circuit elements and an AC generator or source The output of an AC generator is sinusoidal and varies.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
J.PRAKASH.  The term power quality means different things to different people.  Power quality is the interaction of electronic equipment within the.
Dr. Michael Nasief.  Rotating electrical machines (ac generators)  Electronic oscillator circuits.
Full Wave Rectifier Circuit with Working Theory
Part Three – Relay Input Sources
ELECTRONIC INSTRUMENTATIONS
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Automated power Factor Correction and Energy Monitoring System
Analogue Electronics Circuit II EKT 214/4
Analogue Electronic 2 EMT 212
ECE 3301 General Electrical Engineering
Amplifiers Classes Electronics-II
Power Factor Uncertainty or The Design Engineer’s Challenge
Sinusoidal response of circuits
Amplifiers Classes Electronics-II
Budget *Cost divided evenly between Fuel Cell and Fly Wheel Groups.
Sinusoidal response of circuits
Presentation transcript:

Precision AC Current Measurement Technique Guildline Instruments Limited

Presentation Presenter, Author Richard Timmons, P.Eng., MSc President, Guildline Instruments Acknowledgements Tom Barczyk, McSEE R&D Product Manager, Power Instruments Guildline Instruments Dr. Petar Miljanic

Overview Introduction Current Transformer Measurement Results Stationary Signals Quasi-Stationary Signals Applications and Conclusion

Need for More Accurate Power Measurements Higher Electricity Costs Demand for Better Efficiency Government Mandated Measure Quasi-Stationary Signals Grids are More Noisy Multiple, Alternate Energy Sources Smart, Unpredictable Loads Introduction

Current Transformer Guildline Instruments Limited

Current Transformer Circuit Modified Design Error Correcting Circuit N I Primary Winding N O Output Winding N E Error Correction Winding Single or Multi-Stage Inexpensive to Implement Very Accurate

Current Transformer Manufacture

Measurement Results Guildline Instruments Limited

Source - Fluke 5520 Calibrator Measurement – Guildline 7220 Power Analyzer (Patent Pending) 8 Independent Channels Current and Voltage (3-Phase + Ground) Current – 4 Channels in Series Voltage – 4 Channels in Parallel Measurement Setup

Power Analyzer Current Error Correcting Transformer Voltage Resistive Voltage Divider A/D kHz 8 Independent Channels Processor PC Based Tablet

0.5 A 50 Hz Stationary Sinusoidal Signal AC Current from 5520 in Series I RMS (1) From 4 Independent Channels One Measurement per Period 500 Samples 10 Seconds x 50 Hz Max Noise per Channel About 30 ppm Includes Noise from Fluke 5520 Stationary Signal (1a)

Stationary Signal Current Noise Current Noise < 30 ppm

0.5 A 50 Hz Stationary Sinusoidal Signal AC Current from 5520 in Series I RMS (0.2s) From 4 Independent Channels Measurement Based on Average (i.e. Aggregate) of 10 Adjacent Periods 600 Reported Measurements 120 Seconds x 50 Hz / 10 (Averaging) Max Noise per Channel About 15 ppm Averaging Acts Like a Filter Includes Noise from Fluke 5520 Stationary Signal (2)

Stationary Signal Averaging Filter Aggregation / Average of 10 Measurements Noise Reduced to About 15 ppm

Same 0.5 A 50 Hz Stationary Sinusoidal Signal IRMS (1) From 4 Independent Channels Moving Sample Window of 30 Measurements Used to Calculate Standard Deviation Standard Deviation About 3 ppm for Each Current Measurement Suggests Most of the Type A Uncertainty is from the Source Maximum Standard Deviation Spread on All 4 Current Measurements About 3 ppm High Level of Measurement Consistency Stationary Signal 1(b)

Stationary Signal Standard Deviation Standard Deviation Each Channel About 3 ppm Max Std Dev Spread 4 Channels About 3 ppm

Same 0.5 A 50 Hz Stationary Sinusoidal Signal I RMS (3s) From 4 Independent Channels Measurement Based on Average (i.e. Aggregate) of 150 Adjacent Periods 3 Seconds x 50 Hz 500 Reported Measurements (i.e. 10 Min) Max Noise per Channel About 10 ppm Longer Period of Averaging Improves Filter Includes Noise from Fluke 5520 Reported Signal Very Similar on 4 Channels Implies Signal Noise Dominated by Source Stationary Signal 3(a)

Stationary Signal Long Averaging Filter Aggregation / Average of 150 Measurements Noise Reduced to About 10 ppm

Same 0.5 A 50 Hz Stationary Sinusoidal Signal IRMS (3s) From 4 Independent Channels Moving Sample Window of 30 Measurements Used to Calculate Standard Deviation Standard Deviation on 4 Independent Channels has Almost Identical Traces Again Suggests Most of the Type A Uncertainty is from the Source Suggests Type A Uncertainty of Current Transformers is < 4 ppm Also Shows Very Good Measurement Consistency Stationary Signal 3(b)

Stationary Signal - Standard Deviation with Filtering Standard Deviation of 4 Independent Channels < 4 ppm

50 Hz 0.45 / 0.5 Amp Stationary Sinusoidal Signal Fluke 5520 Generated 0.45 and 0.5 Amps Measured by the Same Current Transformer Signals ‘Pasted’ at Zero Crossing Signal with Current Transient Input into Power Analyzer Represents a 10% Change in Current Amplitude in 1 Period (i.e. 100,000 ppm) IRMS (1) Shows Power Analyzer Settled Within 3 Measurements to < 10 ppm (i.e. 60 msec) 10 ppm Includes Fluke 5520 Noise 0.05 Amp (10%) Transient

10% Current Transient Rising Edge (100,000 ppm) Settled Within 3 Periods < 10 ppm

0.5 Amp 50 / 60 Hz Sinusoidal Signal Fluke 5520 Generate 50 Hz and 60 Hz Measured by the Same Current Transformer Signals ‘Pasted’ at Zero Crossing Signal with Frequency Transient Input into Power Analyzer Represents a 20% Change in Frequency in 1 Period IRMS (1) Shows Power Analyzer Settled Within 1 Measurement to < 10 ppm (i.e. 20 msec) 10 ppm Includes Fluke 5520 Noise 10 Hz (20%) Frequency Transient

20% Frequency Transient Settled Within 1 Period < 10 ppm

Applications and Conclusions Guildline Instruments Limited

Applications Current Transformer AC Current Meter Power Analyzer (Patent Pending) 7220 Power Analyzer Engineering Prototype

Conclusions-1 Asynchronous Sampling With Modern Electronics Equivalent to Phase Locking Averaging Filter Improves Performance by 100% - 300% Comparing Standard Deviation on Different Channels with Same Signal Helps Identify Type A Uncertainty Contribution from Source

Conclusions-2 Implemented Into Power Analyzer with Current Measurements < 10 ppm Error Correcting Transformer Fast Wide-Band A/D Converters Improved Processing Algorithms Measures Both Stationary and Quasi- Stationary Signals Goal is to Improve to < 5 ppm

Providing Precision Measurement Solutions Guildline Instruments Limited