Torque Control.

Slides:



Advertisements
Similar presentations
Cleaning and Shaping of the Root Canal System
Advertisements

Managing Drugs and Alcohol in the Workplace Andrew Ermer Manager – National Construction Services.
Results. Table 1: Baseline Parameters Table 2. Intraoperative Findings.
Dr. Michael Gonsky D.D.S. Poconorootcanal.com
Large Taper Files. Engine-driven files Hand-Using Large Taper Files.
For all of the following cases only ONE NiTi rotary instrument was used per tooth (not a pack of 4-6 instruments) after hand preparation with #8, 10 and.
Research Study Designs
ME 2205 ELECTRICAL DRIVES AND CONTROL UNIT I INTRODUCTION BY B.DURAI BABU A.P/EEE.
Copyright 2003, Elsevier Science (USA). All rights reserved. Chapter 35 Dental Handpieces and Accessories Copyright 2003, Elsevier Science (USA) All rights.
MECHANICAL GLIDE PATH & PREFLARING
International Continuously Variable and Hybrid Transmission Congress
NEBOSH Fire and Risk Management Certificate Issue October
Dental Handpieces. High – Speed Handpiece  To use with bur to cut tooth with decay or other dental anomalies.
Power System Fundamentals
VEX Motors: Presented by: Mr. Harder & Thuan Doan Robotics Training Week 2010.
Manufactured by JSC Geosoft
Types of Group Designs _________-subject design. The experiment compares _____ group across different levels of the IV. e.g., behavior is studied in 1.
1 WELL-BEING AND ADJUSTMENT OF SPONSORED AGING IMMIGRANTS Shireen Surood, PhD Supervisor, Research & Evaluation Information & Evaluation Services Addiction.
DC Motors Micro Motors Mark Lyon Brent Peterson. Outline Motor Overview DC vs. AC Brushless DC Motors Design Considerations Application Considerations.
Higher Physical Education
Obturation: Lateral Compaction
 Rate (how fast) at which charges pass a given point  Measured in Amperes or amps  Current (I)  Electrons moving in a wire make up current and provide.
CLEANING & SHAPING.
Power FETs are an integral power device, it’s ability to switch from on-state to off-state is crucial in quick switching devices. All the while also having.
Foreign Language Anxiety in the Classroom Tien-hui Yu 余天蕙 Seton Hall University.
Ultrasonic vs. Sonic Endodontic Systems: Do they improve canal cleanliness and Obturation? Valerie Kanter and Emily Weldon Department of Endodontics, University.
Advanced Design Applications Power and Energy © 2014 International Technology and Engineering Educators Association STEM  Center for Teaching and Learning™
Health and Safety What is health and safety Who is responsible
Mechanical Engineering By: Michael Wiener. Training And Outlook Bachelor's degree A graduates degree may be sought out for a management position Average.
Chapter 14 Nelson & Quick Jobs & the Design of Work.
13.7 – Resistance in circuits. Electrical resistance Electrical resistance is the opposition to the movement of electrons as they flow through a circuit.
Decreased Risk of Radiation Pneumonitis With Coincident Concurrent Use Of Angiotensin- Converting Enzyme Inhibitors In Patients Receiving Lung Stereotactic.
Be free ENDODONTIC MOTOR. + Freedom in endodontics COMPATIBLE WITH ALL MAJOR FILE MANUFACTURE RS. ACCESS TO FUTURE ENDODONTICS INSTRUMENTS INNOVATIONS.
LightSpeed 2.0 (LS2) Reflects 12 years of experience with LS1. Reduces chance of leaving a separated instrument in the canal. Features a “safe failure.
Shaping with Protaper - Rotary and Hand use - Protaper Obturators
Benefit Virtually eliminates these typical problems with other files such as: Key Feature 1 Unique NiTi wire treatment that controls the material’s memory.
Managing Rotorcraft Safety During Frequently Performed Unique Missions September 28, 2005 AHS International Helicopter Safety Symposium 2005 Philip G.
Quality Education for a Healthier Scotland Multidisciplinary The nature and reality of working safely Mark Johnston Training and Research Officer (Patient.
© 2011 Cengage Learning. All rights reserved. Chapter 14 Jobs and the Design of Work Learning Outcomes 1.Differentiate between job and work. 2.Discuss.
R.A.C.E. Project Urbino March 2012 ITIS “E. Mattei” to R.A.C.E. Leonardo Project – 03_29_2012 Urbino – IT - Massimo Zandri.
Rotary Endodontics.
CAMLESS ELECTRONIC REGULATORY MODULE FOR A 4-S SINGLE CYLINDER I C ENGINE.
Chapter 6 Jobs & the Design of Work. Job Compared to Work Job - a set of specified work and task activities that engage an individual in an organization.
Rotary Ni Ti endodontic system
New from VDW!!.
Principle of the process Design For Manufacturing (DFM)
Power Screws. Ball Screws Problem A stepper motor rotating at 120 rpm is directly coupled to a power screw with a pitch of 1 mm. 1.How fast can the.
SMJE 2103 DC Motors. DC Motor Discussion topics: 1.Basic structure 2.Field circuit connections 3.Equivalent circuit 4.Induced torque 5.Terminal characteristics.
Endodontic Instruments
Simulation of Phase transformation behavior of NiTi doped with Cu during loading using classical molecular dynamics S. Aich, A. Behera and S. Ghosh Department.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
Variable Valve Timing.
Seminar on ELECTRONIC POWER STEERING
Assessment of Safety and Physical Environment factors in Governmental Primary Schools in Dammam Farhan M Al-Anezi.
Cyclic Fatigue of Protaper Instruments
Blue Thermomechanical Treatment Optimizes Fatigue Resistance and Flexibility of the Reciproc Files  Gustavo De-Deus, DDS, MSc, PhD, Emmanuel João Nogueira.
Human Resource Management: Gaining a Competitive Advantage
File Mangement May 21, 2007.
ROTARY ENDODONTIC INSTRUMENTS
Observations.
ABSTRACT RESULTS AND DISCUSSION
CASE STUDY: A survey conducted in an open cast iron ore mine indicated that first-line truck drivers and crane operators showed increasing signs of fatigue,
MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric.
Principle of the process Design For Manufacturing (DFM)
Insulators and Conductors
CREEP C H YADHUKRISHNA
Exercise 9.
PDO Safety Advice Date: 23/08/2015 Injury: Fractured fingers
ATS INCIDENT PREVENTION PROGRAMME
CHAPTER 2: DC DRIVES (Part 3)
Presentation transcript:

Torque Control

Torque Control Predefined torque values are based on new instruments! Used NiTi files have 50-60% decreased resistance to fracture after use with high-torque motors. Gamborini 2001 Predefined torque values on some motors are > than the fracture limit of the NiTi file. Gamborini 2001 Handpieces have different degrees of effectiveness, which affects torque values on files. Gamborini 2001

Influence of torque control motors and the operator's proficiency w/ ProTaper NiTi Yared G, Bou Dagher F, Kulkarni K. OOOOE 2003 To evaluate the influence of 2 electric torque control motors and operator experience with ProTaper NiTi on the incidence of deformation and separation of instruments. Preclinical training in the use of the PT technique at 300 rpm is crucial to prevent instrument separation and deformation. High torque control motor is safe with the experienced operator.

Advantages and disadvantages of new torque-controlled endodontic motors and low-torque NiTi rotary instrumentation. Gambarini G. Aust Endod J. 2001 Advantages: reduced pressure/force required computer-controlled electronics allows for fine adjustment of torque values improved tactile awareness new ‘mental’ awareness > resistance to cyclic fatigue reduces rate of fracture rotary files

Advantages and disadvantages of new torque-controlled endodontic motors and low-torque NiTi rotary instrumentation. Gambarini G. Aust Endod J. 2001 Disdvantages: < cutting efficiency slower instrument advancement increases time of debridement procedure

Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. Gambarini G. J Endod. 2001 investigated the cyclic fatigue resistance high vs. low torque electric motors Profile NiTi: .06/25, .06/20, and .04/25 A = 10 new instruments (control) B = 20 used instruments, high-torque motor C = 20 used instruments, low-torque motor

Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. Gambarini G. J Endod. 2001 group A (new) instruments exhibited significantly higher values of rotation-to-breakage cycles Statistically higher resistance to cyclic fatigue was noted for group C (low-torque) in all sizes compared with group B the use of endodontic motor with lower torque values reduced cyclic fatigue of nickel-titanium rotary instruments.