AC Machines 6077SA NUE 046
3 Phase Synchronous Alternators
At the end of this section you will be able to: Alternators At the end of this section you will be able to: Identify the basic components of a Alternator List the types of rotors used Test motor windings for suitability to connect to the supply Connect in both Clockwise and counter clockwise rotation List the steps for dismantling it
Types Governed By: Load Current Requirements Single or Three Phase Prime Mover Speed
Determines Speed of Alternator Prime Mover Determines Speed of Alternator High Speed Slow Speed Windmill Diesel Motor Water turbine Steam turbine
Speed Determines Number of Poles 50 Hz Required OR
Number of Poles 375 RPM = 16 Poles 750 RPM = 8 Poles 1500 RPM =
Determines Shape of Alternator Number of Poles Determines Shape of Alternator 16 Poles Large Diameter Short length Salient Pole
Determines Shape of Alternator Number of Poles Determines Shape of Alternator Small Diameter Long 2 Poles Cylindrical
Generated Voltage Dependant on Flux density Flux strength Speed of rotation Number of turns per pole Length of pole Area of pole face
Generated Voltage Φm f N = Maximum flux = Frequency = Number of poles
Generated Voltage Φm f N kp kd = Maximum flux = Frequency = Number of poles = Pitch factor =Distribution or Breadth factor
Voltage Regulation Resistance Inductance Coils have both I E V Voltage Drop Due to R Voltage Drop Due to XL
Voltage Regulation Vg Unity PF Terminal Voltage Line Current
Voltage Regulation V less than E I V E Lagging PF of 45
Voltage Regulation Vg Terminal Voltage Unity PF Lagging PF Line Current
Voltage Regulation V More than than E I E V Leading PF of 45
Voltage Regulation Leading PF Vg Terminal Voltage Unity PF Lagging PF Line Current
Voltage Regulation If PF = Unity 100 x VNo Load – V Full Load R% = 100 x I x (R x cos + XL x sin) R% = VFull Load
Excitation With Brushes DC Generator Brushes Rotor Stator
Excitation Without Brushes Rotating Components Excitation Stator Sensor & Regulator
Synchronising Generators Synchronized when all lamps dark
Synchronising Generators Synchronized when 1 lamp dark 2 lamps light
END