Monitoring Vibration on Tunnel Fans Safety First The worlds developing infrastructure creates many technical challenges for engineering and construction.

Slides:



Advertisements
Similar presentations
Fire Behaviour Ventilation. Aim To provide students with information to give them an understanding of the behaviour of fire.
Advertisements

VIBRATION AND LUBE OIL PRESSURE SWITCH INSTALLATION AND MONITORING Higgins Station.
Engine Tune-Up By Jonathan Rollins.
Chapter 3: Planning a Network Upgrade
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Airflow and BSC Biosafety and Biosecurity Awareness Training
Stem Challenge Energy management systems, CHP, Harvester tank, green roofs and underfloor heating. 1.
Utility Management Providence Health System - Oregon Environment of Care.
André Augustinus 16 June 2003 DCS Workshop Safety.
PLANT HVAC SYSTEMS DU-109-PP PLANT HVAC SYSTEMS.
INTD 51 human environments building systems. heating/ventilation/air-conditioning (HVAC) maintain a comfortable indoor climate control temperature and.
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
Air-Conditioning Control Systems
Protecting Your Milling Operations Industry Leading Machine Monitoring Technology.
MineralScan Lite Installation Guidelines Digital Control Lab, LLC NW 6 th Street, Suite F Gainesville, FL Main Unit power 90 – 240 VAC 50/60.
FrontPower FRONT PTO 540 RPM or 1000 RPM
Emergency Lighting Code Review Presented by Iota Engineering LLC.
Zone Valves.
© Emotron AB Protection against damage and downtime Emotron M20 Shaft Power Monitor.
Accelerometer’s for Wind Turbines Alternative Energy Wind turbines are a growing source of alternative clean energy sources. As individual machines, or.
Backdraft Dampers. Backdraft Damper Training Application Backdraft dampers allow air to flow in one direction only and prevent unwanted (hot/cold outside.
Buildings and Structures 2 Natural and Mechanical Ventilation.
Vibration Sensors for Cooling Towers Challenges Cooling towers offer the vibration analyst many challenges in sensor selection, mounting and environmental.
Daya Bay RPC Gas System: Safety Subsystem Changguo Lu, Princeton University (Jan. 12, 2008)
MEGALOPOLIS (CHAPTER 4: PART 2). WHERE’S MEGALOPOLIS?
 This link is about how measuring stress has changed over the years to the present day.  These strain gauges are use to measure the amount of stress.
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Hydrotherm’s NEW KN Series
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
Load Bank 負載測試器 RGR 高壓接地電阻器 What Is A Load Bank? Load Banks are devices designed to provide electrical loads for testing power sources such as for testing.
Introducing new life saving eco friendly product the ‘SOLATRON SOLAR AUTO VENT’ You will never enter a scorching car anymore! The SSAV vents out the hot.
© ABB Group August 13, 2015 | Slide 1 Power Generation Service Life Cycle Management for Power Plants Daniel Looser, Power Gen Europe in Amsterdam, June.
1 INTRUSION ALARM TECHNOLOGY CABLING FOR BURGLAR ALARMS.
Alarmline Linear Heat Sensor Typical Applications.
Vibration Monitoring & Machine Protection Systems Copyright 1999, Frank Howard, STI Vibration Monitoring, Inc. League City, Texas USA Reciprocating.
Vibration Monitoring & Machine Protection Systems Cooling Tower Vibration Monitoring.
Chap 9 Structure Cabling Project Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
The Saigon CTT Semester 1 CHAPTER 9 Le Chi Trung.
The AHU From A Case Study Presented by David Sellers Portland Energy Conservation Inc. INLAND EMPIRE CHAPTER 1 - 2/27/2002.
Founded 1989 “Hybrid” transportation provider 150+ Vehicles in Fleet 97% of Miles Driven are “GREEN” Largest Private “GREEN” Fleet in United States. About.
INTRUSION ALARM TECHNOLOGY
INTRODUCTION 1 What word comes to your mind to describe “ The attempt by two objects to occupy the same space at the same moment in time”
UTILIZATION OF VISIBILITY MONITORING FOR FIRE DETECTION.
DAQ Systems and Instruments for Hx Performance Testing and Periodic Monitoring.
High Sensitivity Smoke Detection
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
MICE Hydrogen Control System MICE Collaboration Meeting CM33 27 th July 2012 PJ Warburton – STFC Daresbury Lab.
1 Paging and distributed speaker system Start part ll Paging and distributed speaker system Start part ll BASIC TELECOMMUNICATIONS.
GIF in EHN1- layout, construction and schedule Adrian Fabich, EN-MEF-LE GIF users meeting, 12 th February 2014.
MICE Hydrogen Control System MICE Safety Review Meeting 4 th Oct 2011 PJ Warburton - Daresbury Lab.
HVAC sensors. Smoke detection Zone 1 Zone 2 Spread of fire gases in ventilation ducts.
Utility Engineers, PC.  Generation  Transmission  Distribution.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
MNM Fatal /14 Fall of Material Accident Fall of Material Accident August 12, 2010 (Nevada) August 12, 2010 (Nevada) Underground Gold Mine Underground.
Mine Emergency Preparedness Training Mine Recovery.
Diesel Building Fire Damper Failing Closed Mike Walker TVA.
COOLING & VENTILATION PLANTS M. Nonis – CERN EN Department / CV Group Annual Meeting of the FCC study – Rome 14 th April 2016.
ELECTRICAL INSTRUMENTS ( service and utilization )
VIEW SERIES with Sliding Door
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Ahmad Faizan Hassan Ikram Waleed Malik
PRESENTATION ON MPT ICS SYSTEM
AFCI Protection: AFCI Receptacles and the NEC
Emergency Electrical Power Supply for Buildings
RV Safety Alarms Education Test
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Exhaust gas intake to cabin air.
Presentation transcript:

Monitoring Vibration on Tunnel Fans Safety First The worlds developing infrastructure creates many technical challenges for engineering and construction. Quite often names like “Chunnel” (English Channel), “Big Dig” (Boston), and “Nam Wan” (Hong Kong) are feats to marvel at as they provide passages underground, underwater, or straight through a mountain for today’s highways and rapid transit systems. Commuter Train Exiting Underground Tunnel Although the tunnels provide a very unique form of infrastructure, they also come with their own set of environmental problems. It is only natural in today’s world that the tunnels will become polluted with COx from gasoline based engines, and NOx and smoke from diesel based engines. These toxic gas emissions need to be cleared from the tunnel and replaced with fresh air. This ventilation process keeps those of us that use the tunnels healthy, and in the case of an emergency, safe. Ventilation Purging of toxic gases with a supply of clean air requires Tunnel Jet Fans. These fans provide longitudinal ventilation of the tunnel and are the primary sources of clean air. Jet fans provide a very high impulse or thrust of clean air into the tunnel and through the tunnel. They are often found in multiple sets mounted on the roof or side wall of the tunnel at selected intervals. The number of fans required is based on tunnel length and design. A Pair of Tunnel Jet Fans Axial flow fans are also used to vertically clear smoke from the tunnel in case of a fire. These very large axial flow fans are mounted in vertical shafts, and act as forced air chimneys during emergencies. Often a series of dampers is also placed in the roof of the tunnel to allow the

longitudinal jet fans to assist air flow to the axial flow ventilation fans. This combination quickly clears the tunnel of smoke and allows emergency crews to take the necessary actions. Process Monitoring The critical nature of these fans to provide environmentally safe air requires 100% performance 24 hours/day. Monitoring the vibration of these fans is one of the requirements to make sure that they are running smoothly, and will not unexpectedly fail. Trending and alarming the vibration in the tunnel control center utilizes 4-20 mA current loops from sensors and transmitters. Typical 4-20 mA Loop Power Circuit Utilizing such a common industrial circuit design means that the fans can be monitored by the tunnels “in house” PLC or DCS control system. This makes it easy for the operators to trend and track fan vibration during normal day – day activities. The vibration monitoring of the fan can be accomplished in two different manners. 1. General purpose accelerometers, like the AC102 Series, can be placed on the fan, and connected to a transmitter, like the VX Series, that filters and converts the vibration signals to 4-20 mA. This combination will provide process control and allow for dynamic vibration analysis. AC102 Series Sensors with Transmitters 2. Dual output loop power sensors, like the AC400 Series, could be installed on the fans. This dual output sensor filters and converts the vibration signals to 4-20 mA to provide process control and also allows for dynamic vibration analysis. Sensor Mounting The number of sensors to mount on each fan will be determined by the design of the fan and the extent of monitoring required. A secure mounting method is required, and the time should be taken to properly locate and mount the sensors. Several options are available for permanent mounting. 1. Stud mounting with spot face 2. Mounting pad with adhesive 3. Zerk fitting adaptor 4. Fin mount

Horizontal Vibration Sensor Mounted on Tunnel Fan Motor Cables Cable management is also a concern with tunnel fans. Quite often there is a significant amount of air flow and long distances involved from the sensors to the transmitters, or directly to the control room in the case of dual output sensors. Care must be taken and plans put in place to assure that the cables are run in a manner that protects them. Access holes and conduit pipes may be required to protect the cables. Completed Conduit Connection Junction Boxes Sensor outputs will be collected by junction boxes, and then processed by the PLC or DCS. If you are using the LP400 series sensor, the SB142 or SB242 series junction boxes will mange the dual outputs. Drilling Access Hole for Conduit Good organization of the wiring will provide robust and understandable wire runs. Each wire should be labeled, and matched to the corresponding sensor. If an alarm occurs, the vibration analyst can measure the dynamic vibration and analyze the frequencies to determine root cause. Summary Monitoring the vibration on tunnel fans is critical to maintain fresh air for health and safety providing reliable sources of infrastructure.