07 October ‘04 JCOV R. Lindner Water leak detection at LHCb Detection of cooling water leaks below electronic racks.

Slides:



Advertisements
Similar presentations
Smart heat for comfort and safety 1 Self-regulating system to maintain water flow in gutters and downpipes.
Advertisements

The D.C. Scout Battery Distribution System Ground Locator
ADT490 TroubleShooting Locating Grounds A. 2 Introduction ‣ Fire Alarm Panels cannot tolerate grounds ‣ A ground on any fire alarm circuit is detected.
GS3055-I GSM Universal Wireless Alarm Communicator
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
Remote Monitoring and Management Solutions ®
Medical Gas Alarm Panels
High Sensitivity External Leak Detection for Liquid Fuel Pipelines David Parman P.Eng. Ken McCoy.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
You Can Measure the Benefits… Training Course Introduction to SmartScan.
Electric charges in motion CHAPTER 20. Continuos flow of charges: electric current §Flow of charges between two regions with opposite net charges §electrons.
Classification of Instruments :
Objective of the Lecture Describe a basic electric circuit, which may be drawn as a circuit schematic or constructed with actual components.
Alarmline Linear Heat Detection
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
EKT314/4 Electronic Instrumentation
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Alarmline Linear Heat Sensor Typical Applications.
WATER LEAK DETECTION SYSTEM
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
TF Joint Voltage Drop Instrumentation Robert Marsala (609) Hans Schneider (609) Engineering Operations August 7, 2003 TF_JOINT_Final_Design_Review.ppt.
Module 7 – Power Systems: Tethers
Linear Heat Detection.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
Basic Cathodic Protection Measurement and Monitoring- IR Considerations Western Regional Gas Conference 2008 Tempe, Arizona By Paul Sedlet, Accurate Corrosion.
Sensors and Electricity. What is a Sensor? A sensor is a device that: A sensor is a device that: 1) Measures a physical quantity 2) Converts this measurement.
Direct Current And Resistance Electric Current The Battery Resistance And Ohm’s Law Power Internal Resistance Resistors In Combination RC Circuits Written.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
High Sensitivity Smoke Detection
Current, Resistance and Power
Developing situation … becomes a fire … if detected … triggers extinguishing … ending in loss phone Hazardous Temperature.
FM GLOBAL MARKETING/NETWORKING. Outline Brief FM Global Insight Approval Highlight Applications Interesting Information.
PSAA Curriculum Unit Physical Science Systems. Problem Area Energy and Power Systems.
Electricity Currents, Circuits Electricity that moves… Current: The flow of electrons from one place to another. Current: The flow of electrons from.
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
Electric Charges & Current Chapter 7. Types of electric charge Protons w/ ‘+’ charge “stuck” in the nucleus Protons w/ ‘+’ charge “stuck” in the nucleus.
FIRST Electrical Design FIRST Robotics Championship Conference Steven Shade Team 1111 April 16, 2003.
Codan 5700 Series C-Band Transceiver Technical Overview.
SECURITY ALARM Done by RINKESH KURKURE.  This project serves as a detecting mechanism to indicate the presence of an object or person in undetected cases.
ELECTRIC CURRENT. What is current electricity? Current Electricity - Flow of electrons What causes electrons to flow? When an electric force is applied,
Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC January 17, 2003TOTEM plenary meeting -Marco Bozzo1 CSC detectors for T1.
Invensys Controls Europe An Invensys Company EWCM 41x0 family New 32x74.
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
TS-CV-Detector Cooling 22-Jan-04P. Tropea - JCOV1 Design, construction and installation of a double loop fluorocarbon 150 kW cooling plant for the CMS.
Physics 12 Circuits 3 – Series Mr. Jean. The plan: Video clip of the day Power Series Circuits Resistance in Series Application of Ohm’s Law.
S V.MOUNICA 09551A0294.  To increase the distribution rate of present electric supply which is 70% to 100%.  Improving the supply to house holds without.
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
AGROFARM WEATHER MONITOR USING LabVIEW. INTRODUCTION Innovation in agriculture field Implementing instrumentation tech. in agricultural field The quantity.
Simple Water Level Controller Circuit with Microcontroller and Alarm.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
ECGR-6185 Advanced Embedded Systems Wireless Sensor Network for pH Sensing Sushant Sengupta.
EKT 451 CHAPTER 6 Sensor & Transducers.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
Temperature sensors Temperature is the most often-measured environmental quantity. This might be expected since most physical, electronic, chemical, mechanical,
Hemodialysis Lecture 3.
GROUND-FAULT GROUND-CHECK MONITOR
Identifying SLC 500™ System Components
The Electric Circuit.
Vibration Monitoring System M14
Day 2 Training - Technical
Circuit Components.
Series and Parallel Circuits
724 Temperature Calibrator
DeviceNet Communication Solution for Discrete Devices
Door Heat Exchanger: Specification
Fluid Power System Electrical Control
Presentation transcript:

07 October ‘04 JCOV R. Lindner Water leak detection at LHCb Detection of cooling water leaks below electronic racks

07 October ‘04 JCOV R. Lindner Counting House Three levels

07 October ‘04 JCOV R. Lindner UX85-SALLE DE COMPTAGE JMB Slight slope towards one side

07 October ‘04 JCOV R. Lindner Lowest point of the barrack Sensor cable

07 October ‘04 JCOV R. Lindner Leak Detection The sensing cable has two insulated wires and two conductive polymer coated electrodes. A small DC voltage (5-9 volts) is applied to the sensing cable, and internal resistors limit the current flow through the sensor cable loops to approximately 75 microamps. The actual amount of current flowing is monitored by measuring the voltage drop (V1) across an internal reference resistor. If a spill occurs, additional current will seek the path of least resistance and flow across the leak. This results in increased current flow through the reference resistor. The resultant increased voltage drop across the reference resistor signals the module to turn on the alarm. Continuity Monitoring If the cable is broken, no current will flow in the loop. The voltage across the reference resistor decreases to zero and the internal circuitry recognizes this as a continuity fault. Leak Location After a leak has been detected, the circuitry in the module is automatically reconfigured into the locating mode. The digital readout of the location is generated by measuring the voltage drop along the sensing cable between the leak and the module. The voltage drop is linear and proportional to the leak location. A different scaling factor is applied for feet, meters, or zones. Leak detection is accomplished by monitoring the voltage across an internal reference resistor. Leak location is determined by measuring voltage drop along the cable from the module to the leak.

07 October ‘04 JCOV R. Lindner

07 October ‘04 JCOV R. Lindner Basic System Locating system The leak detection event is logged to an event history file and all status and event information is made available via RS232/RS485 MODBUS to any host PLC or plant or building automation sys-tem. With its internal alarm relay and front panel LED status indicators, the TTSIM-1A can be used as a stand-alone leak detection alarm or it can be connected to TraceTek SIM network, Distributed Control System or Building Management System

07 October ‘04 JCOV R. Lindner Description The TraceTek® TT-NRM Network Relay Module provides the capability to add up to 320 individual alarm relays to a TraceTek TTDM-128 / TTSIM leak detection network. The TT-NRM communicates with the TTDM-PLUS/128 via the same RS-485 network used for TTSIMs. The TT-NRM can be installed in a wide variety of configurations, allowing many leak detection system layout possibilities. Expandable The TT-NRM is supplied as a base unit (with power supply, communications interface, DIN rail and end blocks) and separate relay modules. Each relay module contains 2 independently addressable relays. Up to 16 relay modules can be installed on each base unit, and up to 10 base units can be connected to a single TTDM-PLUS. The leak detection network can be expanded at any time with minimal effort. TT-NRM Network Relay Module

07 October ‘04 JCOV R. Lindner

07 October ‘04 JCOV R. Lindner Product characteristics Cable diameter 0.24 in. (6.0 mm) nominal Cable diameter with connecter 0.52 in. (13 mm) nominal Continuity and signal wires 2 x 26 AWG with insulation of fluoropolymer Sensing wires 2 x 30 AWG with jacket of conductive fluoropolymer Carrier Fluoropolymer Cable weight (50-ft length) 2.3 lb Technical Information Breaking strength 160 lb Cut-through force >50 lb with in. blade; crosshead speed 0.2 inch/minute Abrasion resistance >65 cycles per UL 719 Maximum continuous operating temperature Sensing cable: 194°F (90°C) Cable connectors: 185°F (85°C) Chemical resistance Cable functions normally after Trichloroethylene (100%) exposure in accordance with Sulphuric acid (98%) ASTM D 543 at 77°F (25°C) Hydrochloric acid (37%) for seven days: Hexane (100%) Methanol (100%) Sodium hydroxide (10%) Xylene (100%) Aqua regia Note: Prolonged exposure to concentrated ketones may cause temporary reduction of sensitivity; consult factory. Radiation resistance Cumulative radiation exposure of 10 megarad gamma radiation over design life of 30 years.

07 October ‘04 JCOV R. Lindner TT3000 TraceTek Sensing Cable for Conductive Liquids TraceTek TT3000 sensing cable detects the presence of conductive liquids at any point along its length. Most acids and bases and even deionized water can be sensed and located. Installed with a TraceTek alarm and locating module, the cable senses the presence of fluid, triggers an alarm, and pinpoints the location. Distributed sensing TT3000 sensing cable provides distributed leak detection and location over a wide range of areas. The cable is availablein a variety of lengths to provide as much coverage as needed. Design flexibility TT3000 sensing cable is available with factory-installed metal connectors that plug together. The measurement circuit is not dependent upon the conductivity of the leaking fluid. Therefore, the same cable will detect a wide range of fluids without special design considerations or calibration. The cable is designed for a variety of applications, including floor surfaces, subfloors,equipment locations, pipes, storage tanks, and trenches. The cable is small, lightweight, and flexible, allowing easy installation. The smooth design allows quick drying. Advanced technology Raychem’s conductive-polymer technology and fluoropolymer construction make TT3000 sensing cable mechanically strong and chemically resistant. The cable is constructed of two sensing wires, an alarm signal wire, and a continuity wire embedded in a fluoropolymer carrier rod. This rugged construction exposes no metal, and enables the cable to be reusable even in corrosive environments.