PROTECT 3.M 15 – 120kVA. PROTECT 3.M the new generation of uninterruptible power supplies (UPS) with 3-phase Mains input and 3-phase Mains output.

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Static Transfer Switch
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
G.E. UPS Productline.
Model B1 19-inch Rack Static Transfer Switch. Why choose a model B1 static transfer switch? Increases power availability. True solid state. Rugged, reliable.
GS3055-I GSM Universal Wireless Alarm Communicator
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
MODULAR SMPS POWER PLANT
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
GE Power Quality EP Series UPS
LP33 Series UPS kVA 400Vac/CE
DPA TM UPScale Best-in-class modular UPS for maximum availability.
NT series introduction UPS training June 2006 Markus Schwab.
UPS H series introduction UPS training June 2006 Markus Schwab.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
DC POWER SUPPLY. Maeil Power Co.,Ltd is a one of leading supplier of switching power supply. The company design and manufacture quality products that.
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior.
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Newave SA, Switzerland – - 28/02/ Conceptpower Modular 80 and 100kVA THE BEST WAY TO PREDICT THE FUTURE IS TO INVENT.
FG Wilson Access 4000 Control Panel
Janus Convertible Line – interactive Series UPS
Uninterruptible Power Systems
POWER PLANT USED IN TELECOM
MarsⅡ On-Line UPS Series
PowerScale 10-50kVA Ed Maximize your availability.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Modular Inverter.
Hardware Training Product: ITMS2.
Delivering total power infrastructures worldwide for IBM.
RACK Mountable & Modular Continuous Power Protection Availability
650 VA Power Tree UPS 650VA 100% Stabilized Output Power
Model A 19-inch Rack Static Transfer Switch. Why choose a model A static transfer switch? Break before make transfers Break time < ¼ Cycle Will not transfer.
Power Quality Product Overview
LP Series 400V CE GE Consumer & Industrial September 2004.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Copyright© 2005 Avaya Inc. All rights reserved Avaya UPS Training powerware.com/avaya.
1 Powerware VA – 3kVA Nonstop perfect power for networks, web servers and telecommunications applications.
Exit REMOTE POWER SYSTEM ”Turning your copper into gold”
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Avaya 9130 and 9135 Online UPS 1000 to 6000 VA. Avaya Applications Advanced power protection for: u S8700/S8500/S8300/S8100 Media Servers u Unified Communications.
FLATPACK Rev.5 September 2002 Updated versions may be available.
UPS SG-CE Series 300 kVA. SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V.
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
Technical Panel Session. Sunday January 11, DC System Failure Modes IEEE PES SBC Winter Meeting. January 11 – 15, New Orleans, LA Part 3.
Avaya VA Line-interactive UPS
Avaya Online UPS 6000 VA.
RACK Mountable & Modular Continuous Power Protection Availability
Avaya Online UPS 6000 VA.
RACK Mountable & Modular Continuous Power Protection Availability
PowerValue 11 RT Sales Presentation
True modular UPS system for critical applications
Maximize your availability
PowerValue 11/31 T Sales Presentation
Best-in-class modular UPS ensuring business continuity
بِسمِ اللهِ الرَحمنِ الرَحیم
Introducing the new 700–3000 VA UPS from Eaton
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Presentation transcript:

PROTECT 3.M 15 – 120kVA

PROTECT 3.M the new generation of uninterruptible power supplies (UPS) with 3-phase Mains input and 3-phase Mains output

PROTECT 3.M General data PROTECT 3.M will be offered in two cubicle variances. Variance 1: Cubicle dimensions: (W x H x D) 600mm x 1600mm x 1000mm Maximum 6 modules each 15kVA = 90kVA per cubicle Variance 2: Cubicle dimensions: (W x H x D) 600mm x 2000mm x 1000mm Maximum 8 modules each 15kVA = 120kVA per cubicle 15kVA per Modul (hot-swappable) Degree of redundancy selectable via Display Each Modul is independent, Controllcard/Display are just for Communication and Indication. Integrated Distribution with up to 36 breakers as an option LCD Display Communication via RS232, RS485, SNMP & AS400

PROTECT 3.M General data 1.6 m cubicle MB at the bottom 2.0 m cubicle MB at the top

PROTECT 3.M High MTBF ability Each UPS module in the Protect 3.M is the full function UPS. There is no additional controlling module to the parallel application and load sharing. Regarding to the serious calculation on the system MTBF, if you have two more UPS modules for parallel redundancy, the system ability is above % and the MTBF will be close to 15 Million Hours. MTTR Once the system has one more UPS module for parallel redundancy, the system will still keep working if one of the UPS modules fails. If the failed modules exceed the parallel redundancy modules, the module replacement procedure only need 5 minutes for system recover.

PROTECT 3.M Battery Battery +/- 240Volt DC (20 bloc for each string) Integrated batteriecharger in each Module (2700W / 4.5A) Battery Management in two steps Step 1) up to 90% battery capacity  constant current Step 2) above 90% capacity  constant voltage

PROTECT 3.M Technical data part I Classification VFI SS 111 acc. to IEC Protect 3.M 1.6m rackProtect 3.M 2.0m rack Type power90 kVA120kVA 72 kW96 kW max. modules per rack68 UPS-input Input voltage400 / 230Vac (3/N/PE~) Input voltage range without battery mode Vac(3ph~) Frequency50 Hz / 60Hz Current consumption (max.) 120A with 6 modules 160A with 8 modules Power factor> 0.99 at 100% Load THD(i)<=5% UPS-output Rated output voltage400V ± 2% Frequency in battery mode50 Hz ± 0.5% Output current 22 A / per module 132A with 6 modules 22 A / per module 176A with 8 modules Transfer time at mains outage0 ms ( zero transfer ) Voltage waveformSinusoidal Overload response (online mode)130% for 10min / 150% for 1min Crest factor3

PROTECT 3.M Technical data part II Battery Nominal voltage 240VDC (40pcs for each set in series connection. One battery neutral wire from the central) Autonomy timeFree to choose runtime extension with scalable external battery. Available configurations with 24,38 or 65 Ah) Overload / deep discharge protectionYes Communication InterfacesRS232 / RS485 for status and measurement values, Communication slot ( for pot.-free contacts or SNMP adapter) Shutdown software (on CD)Included for all typical operating systems (e.g. MS- Windows,Novell Netware,Mac OS,Linux,Unix derivates, etc.) Failure indicators (acoustic/optical)LCD with digital information of input and output parameters (voltage,frequency,power etc.) battery parameter incl. failure diagnosis by password protect level, LED for status and main failures.

PROTECT 3.M Technical data part III General data Efficiency total> 90% Audible noise (1m distance)<62 dB Operating temperature range0º - 40 ºC Humidity20% - 90% Installation heightup to 1000m, at nominal load Equipment colourRAL 7035 Size approx.W x H x D (mm)600 x 1600 x x 2000 x 1000 Weight appr. (kg) 250kg rack + 35kg per module 300kg rack + 35kg per module CertificationCE

PROTECT 3.M · Applications Single - and multi-user systems ( Workstations, FileServer, Application Server,... ) Network protection (client / server architecture) e.g. intranet / internet application EDP - equipment (CAD - systems,...) Communication equipment (IT - sector) Component protection of telecommunication Cash systems (trade) Other user-critical applicationen (process systems (stored-program contoller,... ))

PROTECT 3.M · conceptual highlights Modularity with UPS plug-in modules in VFI (double-conversion) technology n + x technology free choice of redundancy level scalable design for flexible power- / autonomy time requirements central simplified management more efficient service independent UPS - modules (without any central control logic)

PROTECT 1.M · UPS classes Publication by ZVEI: UPS Guide by additional lightning arrestors Voltage Phenomenon Time e. g. IEC UPS solution Outage - blackouts Sags / brownouts Dynamic overvoltage Undervoltage Overvoltage Lightning Transients (Surge) Frequency variations Voltage distortion (Burst) Voltage harmonics > 10 ms continuous sporadic < 4 ms sporadic periodic continuous VFD Voltage + Frequency Dependent VI Voltage Independent VFI Voltage + Frequency Independent Classification 3 Offline Classification 2 LineInteractive Classification 1 (true) Online real Double- Conversion

Protect 3.M System architecture Integrated Distribution with up to 36 breakers as an option Communication module incl. communication port LCD-Display UPS-modules each 15kVA

PROTECT 3.M · UPS module design Inverter Battery system Rectifier Load Mains Electronic static bypass ~ ~ Battery charger ~ PFC Filter Mains filter DSP / CanBus control logic unit RS232 SNMP DC/DC Booster High power reserves as a result of a max. 24 kVA total output High safety reserves as a result of n+x technology Independent UPS modules (no central control) slide-in types; suitable for rackmount Diagram of an UPS PROTECT module :

PROTECT 3.M · n + x technology · redundancy level n + x technology advantage Quantity of UPS modules Loadmodulmodules 15 kVA no redundancyn + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) n + 5 (75 kVA) n + 6 (90 kVA) n + 7 (105 kVA) 30 kVA no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) n + 5 (75 kVA) n + 6 (90 kVA) 45 kVA no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) n + 5 (75 kVA) 60 kVA- - - no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) n + 4 (60 kVA) 75 kVA no redundancy n + 1 (15 kVA) n + 2 (30 kVA) n + 3 (45 kVA) 90 kVA no redundancy n + 1 (15 kVA) n + 2 (30 kVA) 105 kVA no redundancy n + 1 (15 kVA) 120 kVA no redundancy Higher reliability Easy to increase overall capacity Modules hot - swapable (without any interruption)

Protect 3.M Usage >> Delivery Cubicle packing Module packing

Protect 3.M - Mains connection MainsBatteryLoad

PROTECT 3.M – LCD display Appear „green light“ Appear „yellow light“ Appear „red light“ and warning alarm

PROTECT 3.M Communication interface “Dual monitoring“ interface from left to the right: - RS485 - RS232 - RS485 - Expansible AS/400 card with potential-free contacts SNMP / SNMP PRO card (with connector for additional temperature measurements)

PROTECT 3.M SNMP-Adapter SNMP Slot-Adapter for UPS Features: Agent for RFC1628 MIB UPS standard MIB Embedded Web-Server  Monitoring via Web  Configuration via Web Embedded Event Manager  Start of different Jobs  Net Broadcast  Monitoring of environmental conditions  Temperature, Humidity, GenSet, Fire, Air condition, Smoke shutter... Support Software products  Network Management Software „NMS“  NMS special for Power Supply Systems  Shutdown Software “CompuWatch”  Direct multi-server shutdown of different OS with communication modules SNMP Adapter Pro: SNMP Adapter:

PROTECT 3.M AS/400 slotcard Pin 1:UPS Fault Battery below cutoff voltage Pin 2:Summary Alarm: UPS failure, Utility power failure, Battery low Pin 3 and 4:Short from Pin 3 to 4 generates an UPS shutdown, e.g. by installing an external switch for EPO. Pin 5:Common ground for relays (pins 1, 2, 6, 7, 8 und 9) Pin 6:Bypass active; mains operation Pin 7:Battery low Battery voltage is below the predetermined level Pin 8:UPS on; normal operation (relay closed during normal operation) Pin 9:Utility Failure; battery operation Attention ! Contact load rating: AC / DC  24 V / 0,5 A Pin- assignment Description 1UPS Failure 2Summary alarm (signal of pins 1, 7and 9) 3Emergency shutdown, e.g. connection of an external switch for EPO (closer) 4 5Common ground for pins 1, 2, 6, 7, 8 und 9 6Bypass active 7Battery low 8UPS on 9Utility Failure

UPS system: PROTECT 3.M Graphical front-end of CompuWatch Normal operation

PROTECT 3.M