Chris Jacobsen Department of Physics & Astronomy Stony Brook University, USA Microscopy for biomedical, biofuels, and environmental.

Slides:



Advertisements
Similar presentations
BACKGROUND THEORY AND TERMINOLOGY FOR ELECTRON MICROSCOPY FOR CyberSTEM PRESENTATIONS.
Advertisements

Observing the Microbial Cell
Microscopy Outline 1.Resolution and Simple Optical Microscope 2.Contrast enhancement: Dark field, Fluorescence (Chelsea & Peter), Phase Contrast, DIC 3.Newer.
Fire Protection Laboratory Methods Day
Groups: WA 2,4,5,7. History  The electron microscope was first invented by a team of German engineers headed by Max Knoll and physicist Ernst Ruska in.
Institut für Mineralogie Detection and Imaging by Electron Microscopy Investigations by using electron microscopy offer the possibility to detect and image.
Lecture 14. X-Ray Fluorescence Microscopy. X-Ray Synchrotron Giant x-ray ring located at Brookhaven National Laboratory in Long Island New York. Utilized.
Dr. Daniel F.V. James MS B283, PO Box 1663, Los Alamos NM Invited Correlation-induced spectral (and other) changes Daniel F. V. James, Los Alamos.
NSLS-II Life Science Breakout Session. Agenda  Introduction (Miller)  Keynote Speaker: Carolyn Larabell (ALS, UCSF) (30 min)  Technique talks (4 min.
OUTLINE Introduction „Tera-to-Nano“: Our Novel Near-Field Antenna 80 GHz CW Frequency Domain Measurements Picosecond Pulse Time Domain Measurements 2D.
Beam stability requirements: experience from the NSLS X1A STXMs Chris Jacobsen Department of Physics & Astronomy Stony Brook University, NY, USA
Optics. Thomas Young ( ) Wave Optics Diffraction & Interference Christiaan Huygens ( )
STXM Cat Graves Stöhr Group SASS Talk 09/30/09.
Ψ-k workshop on magnetism in complex systems, 16 th – 19 th April 2009, TU WienM. Stöger-Pollach Detection of magnetic properties on the nanometer scale.
Soft X-Ray Studies of Surfaces, Interfaces and Thin Films: From Spectroscopy to Ultrafast Nanoscale Movies Joachim Stöhr SLAC, Stanford University
Single Particle X-ray Diffraction - the Present and the Future John Miao Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center.
Exam II Review. Review of traveling wave interference Phase changes due to: Optical path length differences sources out of phase General solution.
ERL & Coherent X-ray Applications
STED: Nanoscale 3D Optical Imaging Digvijay Raorane & Arun Majumdar Department of Mechanical Engineering Department of Materials Science University of.
Summary 34 1.Cells follow rules of chemistry; 2.Water is the most abundant substance proteins constitutes most of a cell’s dry mass; 3.Four major classes.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Microscope.
Common types of spectroscopy
Transmission Electron Microscopy
Microscopy.
Quiz 10/04/14 1. Recently, it has been possible to increase the accuracy of locating a single fluorophore (see diagram). What factors are critical to how.
DOSE, DAMAGE AND RESOLUTION - FUNDAMENTAL LIMITS IN COHERENT X- RAY-DIFFRACTION IMAGING H. Chapman % R. M. Glaeser * S. Hau-Riege % H. He* M. Howells*
Imaging without lenses Current x-ray diffractive imaging methods require prior knowledge of the shape of the object, usually provided by a low-resolution.
Effective lens aperture Deff
Microscopy. Scale Lenses and the Bending of Light light is refracted (bent) when passing from one medium to another refractive index –a measure of how.
Honors Microbiology: Chapter 3 Microscopy and Staining
Main Bullet #1 Main Bullet #2 Main Bullet #3 Canadian Light Source National Synchrotron Light Facility.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
From Exit Wave to Structure: Is the Phase Object Approximation Useless? ° University of Antwerp, Department of Physics, B-2020 Antwerp, Belgium °°NCEM,
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Structural Study of the  12 Virus By:Elizabeth Brown.
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects Campi G., De Caro L., Giannini C., Guagliardi A., Margonelli A., Pifferi A.
John Miao Stanford Synchrotron Radiation Laboratory Stanford Linear Accelerator Center Crystallography without Crystals and the Potential of Imaging Single.
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects Campi G., De Caro L., Giannini C., Guagliardi A., Margonelli A., Pifferi A.
NANO 230 Micro/Nano Characterization
Molecular Cell Biology Light Microscopy in Cell Biology Cooper Modified from a 2010 lecture by Richard McIntosh, University of Colorado.
Reaching the Information Limit in Cryo- EM of Biological Macromolecules: Experimental Aspects -Robert M. Glaeser and Richard J. Hall (2011)
Characterization of Nanomaterials…
The SPARX FEL Project a source for coherent radiation production in the soft X-ray energy range.
A users viewpoint: absorption spectroscopy at a synchrotron Frithjof Nolting.
Starter: Microscopes Which image is from the light microsope? How do you know?
SSRL Workshop, 10/8-9/ STXM and diffraction-imaging - the view from Stony Brook Janos Kirz, Stony Brook University on leave for at the.
Title: Magnification Lesson Objectives : 1. Can I explain the difference between magnification and resolution? Grade B 2. Can I differentiate between the.
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects.
Summer '07 at CLS Small Angle X-Ray Scattering Peter ChenChithra Karunakaran & Konstantine Kaznatcheev.
Coherent X-ray Diffraction (CXD) X-ray imaging of non periodic objects Campi G., De Caro L., Giannini C., Guagliardi A., Margonelli A., Pifferi A.
Interaction of x-ray photons (and gamma ray photons) with matter.
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
Comparison b/w light and electron microscopes LIGHT MICROSCOPE ELECTRON MICROSCOPE Magnification can be done upto 2000 times Resolving power is less.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
By c.Keerthana.  First described by Dutch physicist frits Zernike in  It is a type of light microscopy.  It is a contrast enhancing optical technique.
Presentation on.  There are many methods for measuring of fiber structure. Such as:  The absorption of infrared radiation  Raman scattering of light.
Microscope.
3.3 Other types of microscopy
NANO 230 Micro/NanoFabrication
Starter: Microscopes Which image is from the light microsope? How do you know?
LIGHT MICROSCOPY basic
Complex Nanophotonics
Types of Microscopy Type Probe Technique Best Resolution Penetration
Iterative Phase Retrieval (Jianwei Miao & David Sayre)
Presentation transcript:

Chris Jacobsen Department of Physics & Astronomy Stony Brook University, USA Microscopy for biomedical, biofuels, and environmental science research

Why include biofuels and organic environmental science? Biomedical research on cells and tissues Need to work with micrometer-thick, wet, organic specimens 3D imaging/tomography Cryo capabilties to minimize radiation damage Fluorescence for trace element mapping Spectroscopy for chemical speciation Analysis software to deal with complexity Biofuels (e.g., ethanol from lignocellulosic materials, bioreactor materials for hydrogen production): same needs! Organic environmental science (e.g., organic coatings on soil particles, bacteria that change metal and radionuclide oxidation states): same needs!

Zone plate microscopes TXM Incoherent illumination; flux not brightness. Fast at present sources! Moderate spectral resolution if condenser zone plate is used: E/(ΔE)  Condenser zone plates are large (~5 mm dia.) and are usually of smaller NA than objective; compromise on resolution STXM Coherent illumination; brightness of NSLS II can make for fast imaging times! Requires new approaches to scanning. 10x lower dose because zone plate is before specimen not after Better suited to conventional grating monochromator: E/(ΔE)≈ Detector plays role of condenser; can use optimum NA

What might be achievable with no losses? Howells et al., JESRP (submitted). See also Shen et al., J. Sync. Rad. 11, 432 (2004)

Tomography in a STXM STXMs have been used for tomography! First demonstration of soft x-ray tomography in any microscope: Haddad et al., Science 266, 1213 (1994); Stony Brook STXM at X1A This example: first tomography of a frozen hydrated mammalian eukaryote. Y. Wang et al., J. Microscopy 197, 80 (2000); cryoSTXM at X1A. But it was slow and used TEM-type stage... Tomography plus spectromicroscopy: Johansson, Hitchcock et al., McMaster/ALS With the right cryo/scanning design, tomography with STXMs at NSLS II should be acceptably fast and with 10x lower radiation dose!

Lenses phase the signal, but lose the signal. Example: 20 nm zone plate with 10% efficiency, 50% window transmission, 20% modulation transfer function (MTF) for 15 nm half-period: net transfer of 1% for high spatial frequencies Can we avoid this ~100x signal loss, and also go beyond numerical aperture limit of available optics? Supplementing lens-based approaches

7 Diffraction microscopy: test specimen Chapman, Barty, Marchesini, Noy, Hau-Riege, Cui, Howells, Rosen, He, Spence, Weierstall, Beetz, Jacobsen, Shapiro, J. Opt. Soc. Am. A 23, 1179 (2006) Resolution ~10x10x50 nm on 50 nm gold spheres in hollowed-out AFM tip 7

8 Pure projections from phased 3D data Chapman, Barty, Marchesini, Noy, Hau-Riege, Cui, Howells, Rosen, He, Spence, Weierstall, Beetz, Jacobsen, Shapiro, J. Opt. Soc. Am. A 23, 1179 (2006)

qxqx qzqz Experimental realization Chapman, Barty, Marchesini, Noy, Hau-Riege, Cui, Howells, Rosen, He, Spence, Weierstall, Beetz, Jacobsen, Shapiro, J. Opt. Soc. Am. A 23, 1179 (2006)

Freeze-dried, unstained yeast Diffraction reconstruction (data taken at 750 eV; absorption as brightness, phase as hue). Stony Brook/NSLS STXM image with 45 nm Rayleigh resolution zone plate at 520 eV (absorption as brightness) Shapiro et al., Proc. Nat. Acad. Sci. 102, (2005). Frozen hydrated work is underway...

Spectromicroscopy Image series near carbon absorption edge (XANES/NEXAFS) Biochemical organization of sperm revealed directly from data: enzyme-rich region, DNA, mitochondria and flagellar motor, lipid H. Fleckenstein, M. Lerotic, Y. Sheynkin et al., Stony Brook. Cluster analysis: Lerotic et al., Ultramic. 100, 35 (2004).

Spectromicroscopy and biofuels Ethanol from lignocellulose materials is promising: large fraction of total biomass, easier cultivation. But there are great challenges in economically separating cellulose from lignin! Soft x-ray spectromicroscopy can map cellulose and lignin so that one can see the effects of various enzymes. DoE proposal with David Wilson (Cornell microbiology), George Cody (Carnegie) Lignin and cellulose in 400 million year old chert: Boyce et al., Proc. Nat. Acad. Sci. 101, (2004), with subsequent pattern recognition analysis by Lerotic et al., Ultramicroscopy 100, 35 (2004).

13 Coherent microscopy at NSLS II NSLS II will provide new opportunities for scanning microscopy: fast enough for practical tomography with reduced dose, spectroscopic sensitivity to biochemical organization Diffraction microscopy provides a path to reduced dose imaging beyond lens resolution limits and without depth of focus limitations. 13

14

C-XANES of amino acids K. Kaznacheyev et al., J. Phys. Chem. A 106, 3153 (2002) Experiment: K. Kaznacheyev et al., Stony Brook (now CLS) Theory: O. Plashkevych, H. Ågren et al., KTH Stockholm; A. Hitchcock, McMaster Polymers: see e.g., Dhez, Ade, and Urquhart, JESRP 128, 85 (2003)

Spectromicroscopy data are complex! Lu in hematite (T. Schäfer) spectra! Sometimes it’s not so bad: domains of immiscible, pure substances for which you have reference spectra Sometimes it can seem hopelessly complex: especially in biology or environmental science How can we deal with this complexity? Aligned spectral image sequenes: Jacobsen et al., J. Microscopy 197, 173 (2000)

X-ray diffraction microscopy Proposed by Sayre (in Schlenker, ed., Imaging and Coherence Properties in Physics, Springer-Verlag, 1980) Through 1999: experiments by Sayre, Kirz, Yun, Chapman, Miao First x-ray reconstruction: Miao, Charalambous, Kirz, and Sayre, Nature 400, 342 (1999)

18 3D imaging with lenses Transverse: Longitudinal: 20 nm resolution at 520 eV: depth of field ~1 µm Through-focus deconvolution with lenses: Confocal: fully incoherent (fluorescence) EM: phase only, coherent TXM: partially coherent, equal absorption and phase contrast, need for experimental CTF

Atomic resolution imaging: electrons or photons? 100 keV electrons About 2.5 inelastic scatters per elastic scatter About 45 eV deposited per inelastic scatter Therefore about 10 2 eV deposited per elastic scatter A thousand scattered electrons: eV into (2 Å) 3, or 2×10 9 Gray 10 keV photons About 100 absorption events per elastic scatter About 10 keV deposited per absorption Therefore about 10 6 eV deposited per elastic scatter A thousand scattered photons: eV into (2 Å) 3, or 2×10 13 Gray Electrons are better than photons for atomic resolution imaging: J. Breedlove and G. Trammel, Science 170, 1310 (1970); R. Henderson, Q. Rev. Biophys. 28, 171 (1995). Crystallography’s answer: spread the dose out over many identical unit cells XFEL answer: get the information before it’s damaged