Electrical eddy currents in the human body: MRI scans and medical implants Brent Hoffmeister Rhodes College Department of Physics.

Slides:



Advertisements
Similar presentations
Energy stored in Magnetic Fields
Advertisements

MRI Phillip W Patton, Ph.D..
PHYSICS OF MAGNETIC RESONANCE
The importance of MRI, a few numbers  MRI units worldwide in 2003  75 millions scans per year performed  Constant need for over 1000 MRI technologists.
MRI in patients with pacemakers DR PRADEEP SREEKUMAR.
Magnetic Resonance Imaging
Chapter 11 – Magnetic Circuits Lecture 6A – (Tutorial) by Moeen Ghiyas 07/05/
Applied Electricity and Magnetism
L 28 Electricity and Magnetism [6] magnetism Faraday’s Law of Electromagnetic Induction –induced currents –electric generator –eddy currents Electromagnetic.
L 28 Electricity and Magnetism [6] magnetism Faraday’s Law of Electromagnetic Induction –induced currents –electric generator –eddy currents Electromagnetic.
Introduction  Image Guided Adaptive Radiotherapy (IGAR) involves the use of an imaging modality to minimize planning treatment volumes required to deliver.
Magnetic Resonance Imaging Mary Holleboom ENGR 302 May 7, 2002.
Interaction of Charged Objects Attraction: can happen also for like-charged objects! Repulsion: can happen only for like-charged objects! Intervening matter.
Basics in Magnetism Electromagnetism Force on a Current-Carrying Wire EM Induction Transformer Generators Electric Motors ELECTROMAGNETISM.
MAGENETIC RESONANCE IMAGINING T2, T5, T7.
MRI Charles Flynn. What is an MRI? A machine that that uses an incredibly powerful magnet for scans Several important parts (super conducting magnet,
Magnetic Resonance Imaging (MRI)
Magnetic Resonance Imaging Astounding. The MRI magnet and patient table The operator’s console.
Diathermy Interactions with Implanted Leads and Implanted Systems with Leads Marian Kroen Office of Surveillance and Biometrics Issues Management Staff.
ELECTRIC AND MAGNETIC FIELD INTERACTIONS WITH MATERIALS By: Engr. Hinesh Kumar (Lecturer)
EEL 3472 ElectromagneticWaves. 2 Electromagnetic Waves Spherical Wavefront Direction of Propagation Plane-wave approximation.
MRI Physics: Just the Basics
Lecture 4: Boundary Value Problems
Chapter 7 Electrodynamics
1 Antennas: from Theory to Practice 1. Basics of Electromagnetics Yi HUANG Department of Electrical Engineering & Electronics The University of Liverpool.
Magnetism Physical Science. What is a magnet?  2000 years ago the Greeks discovered a mineral that attracted things made of iron.  They named this mineral.
Magnetic Resonance Imaging
Prof. Dr. Moustafa. M. Mohamed Dr. Eng. Safa Ahmed El-Askary
PY212 Electricity and Magnetism I. Electrostatics.
A Portable Ultrasensitive SERF Atomic Magnetometer for Biomagnetic Measurements R Wyllie, 1 Z Li, 2 R Wakai, 3 N Proite, 1 P Cook, 1 T Walker 1 1 – Department.
ELECTRODES FOR RECEPTION AND STIMULATION IN THE BODY.
ELECTRODES FOR STIMULATION. Cardiac Pacemakers and Defibrillators  The heart is a natural example of a critical Bioelectromagnetic system.  An electrocardiogram.
Influence of Pacing Lead Design on MRI-Induced Lead Heating Presenter: Stuart MacDonald VP Research and Development Heart Rhythm 2006 Boston, MA May 18,
Chapter 27 Current and Resistance Scalar Sense determined by the movement of the positive charge carrier Average Electric Current Instantaneous Electric.
Human Subjects in fMRI Research Credits: Robert Savoy, Ph.D. Franz Schmitt, Ph.D.
1 Introduction to Magnetic Resonance Imaging درس مقدمه ای بر فیزیک پزشکی Sahand University of Technology Faculty of Electrical Engineering M. Shamsi.
Powerpoint Templates Page 1 Depth Effects of DEP Chip with Microcavities Array on Impedance Measurement for Live and Dead Cells Cheng-Hsin Chuang - STUST.
Pacemakers and MRI An outdated contraindication? Emily Myers Research in Allied Health East Tennessee State University.
Laser Treated Metallic Probes for Cancer Treatment in MRI Systems July 08, Advance Materials Processing and Analysis Center (AMPAC) Department of.
MRI Physics Dr Mohamed El Safwany, MD.. MRI Magnetic Resonance Imaging Magnetic Resonance Imaging.
Assessment of MRI Induced Heating of Cardiac Pacing Leads: Relevance to Target Patient Populations Presenter: Daniel G. Hullihen Jr. Director of Business.
Introduction: So far we have These equations are OK for static fields, i.e. those fields independent of time. When fields vary as a function of time the.
L 29 Electricity and Magnetism [6]
Biophan Technologies, Inc. Jeffrey L. Helfer, Vice President of Engineering ISMRM Workshop on MRI Safety November 6, 2005.
L 28 Electricity and Magnetism [6] magnetism Faraday’s Law of Electromagnetic Induction –induced currents –electric generator –eddy currents Electromagnetic.
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
Medical Resonance Imaging MRI. First medical images: X-rays Discovered in 1895 Images of bones What part of the body is this?
Medical Resonance Imaging
Lesson Plan MRI Scan Experience
Applied Electricity and Magnetism
ELEC 401 MICROWAVE ELECTRONICS Lecture 3
Electromagnetism.
5. Conductors and dielectrics
ELEC 401 MICROWAVE ELECTRONICS Lecture 3
SURGICAL DIATHERMY.
Exam 2 Results Max Avg Std Dev 11.61
SURGICAL DIATHERMY.
Volume 10, Issue 12, Pages (December 2013)
What metals could be used to make an induced magnet.
Volume 10, Issue 12, Pages (December 2013)
Basics of MRI By Dr. Mohamed Samieh.
Applied Electricity and Magnetism
Human Subjects in fMRI Research
E&M I Griffiths Chapter 7.
Lesson Plan MRI Scan Experience
Maxwell’s equations continued
Lesson Plan MRI Scan Experience
Magnetic Resonance Imaging [MRI]
Lesson Plan MRI Scan Experience
Presentation transcript:

Electrical eddy currents in the human body: MRI scans and medical implants Brent Hoffmeister Rhodes College Department of Physics

Research interests and collaborators  Ultrasonic bone assessment Dr. Sue Kaste (St. Jude), Dr. Kendall Waters (NIST) Dr. Sue Kaste (St. Jude), Dr. Kendall Waters (NIST) Students: Andy Whitten, Julie Javarone, Chad Jones, Garney Caldwell, Jeff France, John Janeski, David Johnson Students: Andy Whitten, Julie Javarone, Chad Jones, Garney Caldwell, Jeff France, John Janeski, David Johnson  Ultrasound therapy for osteoarthritis Dr. Karen Hasty (U. Tennessee) Dr. Karen Hasty (U. Tennessee)  Ultrasonic imaging of cardiac electrical stimulation Dr. Bob Malkin (Duke), Amy Curry (U. Memphis) Dr. Bob Malkin (Duke), Amy Curry (U. Memphis) Students: Steve Smith, Will McKinney, Stu Johnston, Erin Sylvester, John Sexton, Chip Hartigan, Taylor Whaley Students: Steve Smith, Will McKinney, Stu Johnston, Erin Sylvester, John Sexton, Chip Hartigan, Taylor Whaley  Magnetic Stimulation Dr. Bob Malkin (Duke) Dr. Bob Malkin (Duke) Student: Drew Shores Student: Drew Shores

Magnetic stimulation  Problem MRI scans expose patients to time varying magnetic fields MRI scans expose patients to time varying magnetic fields Faraday’s Law - time varying magnetic fields induce electrical “eddy” currents Faraday’s Law - time varying magnetic fields induce electrical “eddy” currents Induced currents can cause muscle contraction, nerve stimulation, magnetophosphenes, cardiac arrhythmias Induced currents can cause muscle contraction, nerve stimulation, magnetophosphenes, cardiac arrhythmias Effect of medical implants unknown Effect of medical implants unknown  Goal Model how implants affect magnetically induced currents in the body Model how implants affect magnetically induced currents in the body

MRI Y gradient coil Z gradient coil Transceiver X gradient coil Main coil Patient

MRI Magnetic Fields Coil f (Hz) FunctionBioeffect Main0 Align proton spins ? Transceiver ~10 MHz “Pluck” proton spins RF heating xyz gradient ~ 1 kHz Localize proton signal Nerve, muscle and cardiac stimulation

Particularly interesting implant

Pacemakers and MRI  Concerns about sources of electromagnetic interference in patients with pacemakers.  Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers.  Loss prevention case of the month: not my responsibility!  Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 tesla?  MR imaging and cardiac pacemakers: in vitro evaluation and in vivo studies in 51 patients at 0.5 T.  Magnetic resonance imaging of the brain at 1.5 tesla in patients with cardiac pacemakers: can it be done?  MRI in patients with cardiac pacemakers: in vitro and in vivo evaluation at 0.5 tesla.  Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla  In vivo heating of pacemaker leads during magnetic resonance imaging.

Research question  Most of the research has focused on problems associated with RF fields.  Less research on switched gradient fields, and even less on interaction with implants.  Will metal and plastic objects in the chest increase the danger of switched gradient field stimulation?  The physics…

Faraday’s Law

Induced electric field Conducting cylinder (patient’s body) Increasing uniform B

Eddy currents Current density Conductivity Electric field

What’s going to happen? Metal/plastic object

Metal or plastic?  Both interesting  Plastics not studied  (plastics easier too)

Approach  Develop an analytical model based on Faraday’s law to predict current densities in the vicinity of a plastic implant.  Compare model to experiment and finite element analysis.

Experimental model Helmholtz coils (MRI Z-coils) Dish of physiologic saline (patient) 60 Hz AC

Apparatus

Measurement system Saline dish High impedance amplifier Helmholtz coils Voltmeter Field probe 1.00 cm Twisted insulated wires Probe tips Shielded cable to amplifier

“Implant” geometry?  Pick something easy to start with.  Ideas? ? Saline dish

Effect of plastic “implant” E mag E chg

Analytic model - approach  Find charge density of accumulated charge  Use Coulomb’s law to find E chg  E net = E mag - E chg x y P

Conservation of charge Surface charge density Free and bound charge Normal component At interfaceSaline conductivity

Bound charge Electric susceptibility of water

Differential equation… …and steady state solution

Simplifying assumption 1.2 S/m 80 2  60 Hz

Coulomb’s Law 2W 2L Plastic y z x x y P

E chg

Done! Compare to experiment…

Experiment Not done…

plastic ++++ Side view Saline-air interface Saline-dish bottom interface What’s wrong?  Math OK  Approximations OK  Input parameters OK

A fix  Use a deep beaker instead of a dish. plastic Suspended from fishing line These interfaces far away from measurement region

Theory and experiment Beaker of Saline

Another fix 2W 2L Plastic  Let W go to infinity in the model

Theory and experiment Dish of Saline

Generalizing the geometry x y P  L1L1 L2L2 where

Theory and experiment  = 90 deg  = 45 deg  = 15 deg

What we know so far  Plastics can significantly alter eddy current patterns  Basic effect: eddy currents are forced to flow around the plastic  Effect can be understood as result of charge accumulation at interfaces

Clinical significance  Plastics might redirect eddy currents toward sensitive tissues Torso Heart

Future work  Metal implants  More realistic geometries  More realistic B(t)