METAL FOIL DETECTORS AND THEIR APPLICATIONS ABSTRACT To monitor charge particle fluence distribution, various methods have been developed. We report here.

Slides:



Advertisements
Similar presentations
CBM Calorimeter System CBM collaboration meeting, October 2008 I.Korolko(ITEP, Moscow)
Advertisements

Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
H1 SILICON DETECTORS PRESENT STATUS By Wolfgang Lange, DESY Zeuthen.
1 Pion beam tracker for HADES Jerzy Pietraszko CBM Collaboration Meeting, March 9-13, 2009, GSI, Darmstadt.
1Beam Line Review. 17th November Detector parameters Fermilab Beam line monitors built to replaced SWICS Scintillating fibre tracker – readout.
Section Two Requires e-h pair creation data from Section One and electric field model from Maxwell software package (Fig. 6 - left). The induced strip.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Standalone VeloPix Simulation Jianchun Wang 4/30/10.
M. Palm, CERN1 Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA.
Luminosity Monitor Commissioning MICE Collaboration Meeting March 2010 Paul Soler, David Forrest Danielle MacLennan.
Luminosity Monitors MICE Video Conference 7 May 2009 Paul Soler.
The LHCb Inner Tracker LHCb: is a single-arm forward spectrometer dedicated to B-physics acceptance: (250)mrad: The Outer Tracker: covers the large.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
30 Ge & Si Crystals Arranged in verticals stacks of 6 called “towers” Shielding composed of lead, poly, and a muon veto not described. 7.6 cm diameter.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
 A GEANT4-based simulation was performed of the production target, solenoid, selection channel, and spectrometer.  The acceptance was found to be 8.3x10.
METAL FOIL DETECTORS FOR THE RADIATION AND BEAM POSITION MONITORING ABSTRACT To monitor charge particle fluences distribution various methods have been.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Jornadas LIP 2008 – Pedro Ramalhete. 17 m hadron absorber vertex region 8 MWPCs 4 trigger hodoscopes toroidal magnet dipole magnet hadron absorber targets.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Luminosity Monitor UKNF Meeting 7 June 2010 Paul Soler, David Forrest Danielle MacLennan.
Design and development of micro-strip stacked module prototypes for tracking at S-LHC Motivations Tracking detectors at future hadron colliders will operate.
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
Difference between Roman Pots and VELO Very forward tracking is typically done using detectors located in Roman pots. They are far away from the interaction.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
CBM Silicon Tracking System. Microstrip Detector Module Assembly and Test V.M. Pugatch Kiev Institute for Nuclear Research GSI (CBM experiment), Darmstadt.
Progress on the beam tracking instrumentation Position measurement device Tests performed and their resolution Decision on electronics Summary.
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
15 February 2007Dirk Wiedner / LHCb1 Radiation Monitors for LHCb.
Jyly 8, 2009, 3rd open meeting of Belle II collaboration, KEK1 Charles University Prague Zdeněk Doležal for the DEPFET beam test group 3rd Open Meeting.
Charmonium Production in 920 GeV Proton-Nucleus Interactions Presented by Wolfgang Gradl for the HERA-B
Luminosity Monitoring Issues  ZDC  what’s the advantage?  problems  BBC  can they do it? A. Drees QCD critical point workshop, Mar
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
METAL DETECTORS: PERFORMANCES AND APPLICATIONS Oleksandr Okhrimenko Institute for Nuclear Research NAS of Ukraine, Kiev.
Open and Hidden Charm production in 920 GeV Proton-Nucleus Collisions Presented by Marko Starič for the Hera-B collaboration The.
Proportional chambers with cathode readout in high particle flux environment Michał Dziewiecki.
Luminosity Monitor Design MICE Collaboration Meeting 31 May 2009 Paul Soler.
T2K Status Report. The Accelerator Complex a Beamline Performance 3 First T2K run completed January to June x protons accumulated.
Cascade production – preliminary results Cascades  and  are reconstructed in decay chain   and  K, respectively. Plots in the first row show mass.
Metal micro-detector TimePix imaging synchrotron radiation beams at the ESRF Bio-Medical Beamline ID17 Andrii Chaus Institute for Nuclear Research National.
Simultaneous photo-production measurement of the  and  mesons on the nucleons at the range 680 – 1500 MeV N.Rudnev, V.Nedorezov, A.Turinge for the GRAAL.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
Detecting shielded nuclear contraband using muon tomography Judson Locke, William Bittner, Leonard Grasso, Dr. Kondo Gnanvo; Adviser: Dr. Marcus Hohlmann.
P.F.Ermolov SVD-2 status and experimental program VHMP 16 April 2005 SVD-2 status and experimental program 1.SVD history 2.SVD-2 setup 3.Experiment characteristics.
G.R.White: F.O.N. T. From Ground Motion studies by A.Seryi et al. (SLAC) ‘Fast’ motion (> few Hz) dominated by cultural noise Concern for structures.
07/05/20041 Pentaquark search at HERA-B A. Sbrizzi - NIKHEF Motivation Pentaquark:  + (1540)  pK 0 Conclusion.
MICRO-STRIP METAL DETECTOR FOR BEAM DIAGNOSTICS PRINCIPLE OF OPERATION Passing through metal strips a beam of charged particles or synchrotron radiation.
Quarkonia production with the HERA-B experiment J. Spengler, MPI Heidelberg.
FP-CCD GLD VERTEX GROUP Presenting by Tadashi Nagamine Tohoku University ILC VTX Ringberg Castle, May 2006.
Open and Hidden Beauty Production in 920 GeV p-N interactions Presented by Mauro Villa for the Hera-B collaboration 2002/3 data taking:
Simulated vertex precision
Luminosity Monitor Status
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
R. Bucˇık , K. Kudela and S. N. Kuznetsov
The LHC collider in Geneva
Hall C KPP Demonstration March 10, 2017.
The Pixel Hybrid Photon Detectors of the LHCb RICH
Scintillator tile- SiPM systems R&D
Using Single Photons for WIMP Searches at the ILC
The LHCb vertex detector
Higgs Factory Backgrounds
GEANT Simulations and Track Reconstruction
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
NKS2 Meeting with Bydzovsky NKS2 Experiment / Analysis Status
The LHCb Level 1 trigger LHC Symposium, October 27, 2001
Setup for testing LHCb Inner Tracker Modules
PERFORMANCE OF THE METAL RADIATION MONITORING SYSTEMS
Gain measurements of Chromium GEM foils
Presentation transcript:

METAL FOIL DETECTORS AND THEIR APPLICATIONS ABSTRACT To monitor charge particle fluence distribution, various methods have been developed. We report here on approach based on the Metal Foil Detectors (MFD). The MFD is a device which measures a flux of charged particles by integration of the charge created in a thin metal foil due to the Secondary Electron Emission (SEE) initiated by the incident particles. The radiation profile is reconstructed from the charge distribution in a set of metal foils partitioning the area under study. Their size has to be optimized to provide appropriate profiling and, at the same time, provide charges which are big enough to trigger read-out Charge Integrators (CIs) which perform a current to frequency conversion. The foils have to be thin to minimize multiple scattering of the tracks, and, on the other hand, thick enough for mechanical stability. Conclusions Reliable results on the beam profiling were obtained with the help of the MFD BPIT at proton beam energies of 21 MeV and 920 GeV and with a 120 GeV  - -beam. The achieved sensitivity of the BPIT allows for an on-line beam-profile measurements at beam currents exceeding 1 pA. The developed MFD proved to be a reliable new tool for the charged particle radiation monitoring in a wide range of applications. The advantages of the MFD are extremely low mass of the detecting material, low cost, simple structure, low operating voltage (20 V), simple read-out electronics (charge integrators and scalers) and very high radiation tolerance. V. Pugatch a,b, V. Aushev a,c, C. Bauer b, K.-T. Knöpfle b, M. Schmelling b, M.Tkatch a, Yu. Vassiliev a,c a Kiev Institute for Nuclear Research, b Max-Plank-Institut für Kernphysik, c Deutsche Elektronen-Synchrotron DESY Introduction The first monitor based on Secondary Electron Emission (SEE) initiated by the incident particles has been build already in Since then various types of the SEE beam profile monitors were designed, yet, to our knowledge the principle has not been explored for radiation monitoring using comparatively large area sensors placed in the atmosphere. It was established that the yield of the SEE exceeds by factor of 10 the one of directly produced  - electrons. Metal Foil Detectors (MFD) were built and successfully tested at KINR (Kiev), DESY (Hamburg), MPIfK (Heidelberg) and CERN (Geneva) during the last years for charge particle flux-monitoring. MFD BPIT at 21 Mev proton beam For the purpose of silicon strip detector irradiation study we have built and tested the MFD Beam-Profile-Imaging- Target (MFD BPIT) at MPIfK (Heidelberg). To simulate a non-uniform radiation load 21 MeV protons scattered by the 50  m thick Au-target were used. The test experiment with a 12.5  m thick Ni-foil (2x15 mm 2 ) positioned at very forward scattering angles has confirmed that the rate output of a charge integrator (100 Hz per 1 pA calibrating current) connected to the foil perfectly followed the expected Rutherford scattering behaviour. The obtained values of the proton fluences agreed well with calculations. The BPIT with sizes large enough to cover nearly the whole silicon detector area has been made out of 10 Ni-foils (12.5  m thick, 4 mm wide, 50 mm long) placed on a PCB with a pitch of 5mm. Figure 1. Left part: BPIT (50 x 50 mm 2 ). Proton beam axis is perpendicular to the BPIT plane. Right part: 21 MeV proton beam profile measured by the BPIT. Beam axis is between strips #5 and #6 MFD at 920 GeV proton beam (HERA-B experiment) Another way to reconstruct the beam profile was realized by us for the HERA-B experiment, which operates a set of 8 target ribbons (wires) surrounding the 920 GeV proton beam at two locations along the beam. The typical dimensions of a wire are  m along the beam and 50  m in the radial direction (Fig. 3), to provide an Interaction Rate (IR) 5-40 MHz. In addition to the data from Cis connected to the individual target wires we employed the Silicon Vertex Detector (SVD) data to measure the beam profile in the plane perpendicular to the beam. At the nominal target position of 4 standard deviations from the beam centre (  = 350  m) the IR is very sensitive to the beam shape and its fluctuations (Fig.4), and the knowledge of the beam profile is of a paramount importance for the target steering. The feedback data for steering are derived from Scintillator Hodoscopes for the overall IR and CIs for partial contributions of the individual wires. As an example Fig.6 shows the distribution of the vertices over 4 inserted Titanium targets. The numbers of vertices at each target are nearly equally distributed over the targets and are in a good agreement with the IR distribution provided by MFD and CIs. Figure 6. Vertices distribution over 4 targets surrounding the 920 GeV proton beam (IR = 30 MHz). X and Y are the coordinates of the targets in the SVD coordinate system: the beam axis is shifted down by 1 mm and closer by 3.2 mm to the inner target from the SVD axis. WireCharge Integrators %Vertices % Above   0.7 Below   0.7 Inner   0.7 Outer   0.7 Table 1. Relative rate sharing among wires obtained with the Charge Integrators and primary vertices counting The relative sharing of the IR among the inserted targets is illustrated by Table 1 for the case of the overall IR = 30 MHz. There is a perfect linear relation between the number of the reconstructed vertices and CI-rates for IRs per individual target up to 10 MHz (till multiple interactions per bunch crossing start to affect the vertex reconstruction efficiency. Y (cm) Z (cm) X (cm) C Pd C*C* C Ti W Al P - beam HERA-B Target Setup Figure 3. Reconstructed vertices from 8 targets Figure 4. Correlations IR, CI, beam and target position, Primary vertices. Another essential feature of the Luminosity monitoring by the MFD is that this is a nearly background free method. Indeed, due to small size of the targets the response of the corresponding CI to any background flux of particles is small in comparison with a signal obtained by the beam-target interactions. The Fig. 4 illustrates the evolution of the rates in Hodoscopes (black line), CI-Inner2 (pink) and background counters (red line). The upper plot shows: red – Inner2 target position, blue – X beam position and green dots – Primary vertices reconstructed off-line in the Inner2 target. The unusual behavior of beam movement was perfectly compensated by the Target steering program and nicely seen online by the MFD. HERA-B Rate sharing at multi wire operating mode Luminosity Monitoring for the HERA-B experiment An application of the MFD Luminosity Monitor for the HERA-B Minimum Bias and Physics Trigger runs are shown on the Fig. 5. All 8 HERA-B Targets were operated for few minutes at 0.5, 1, …5 and 5…1, 0.5 MHz interaction rate (rate scan). The interaction rate measurement by the target hodoscopes (scintillation counters) is shown on the upper plot, while the same measurement by the MFD is shown on the lower one. Very good agreement between MFD and hodoscopes results allowed us to conclude that MFD could be used as Luminosity Monitors. Since MFDs have orders of magnitude higher acceptance then the hodoscopes (50% vs 1%) and do not show saturation effects, they are more sensitive to any changes of the beam position and/or hanges in the distribution of detector material close to the beam, like e.g. the positions of the VDS roman pots. Most of the HERA-B Minimum Bias runs show perfect (within 2%) stability of the delivered luminosity measured by the MFD, Hodoscopes, Lumi-counters and another parts of the HERA-B detector, like the ECAL and the RICH. Figure 5. Luminosity Monitoring of MB runs by MFD Beam Profile Monitor for the LHCb Inner Tracker at CERN At X7 test beam area of the CERN-SPS 16 X- and 16 Y-sensors (Al, 50  m thick, 5 mm wide, 6 mm pitch) covering the area of 96 x 96 mm 2 were connected to 32 Charge Integrators (CIs) via 3 m long cables. The X- and Y- sensors were separated (3 mm distance) by accelerating and shielding Al- foils. A data acquisition system periodically read out the rates through a 32 channel VME Scaler, which were then translated into a graphical presentation of the beam profile in the control room. The MFD BPM data have shown perfect correspondence with a similar data measured by a regular BPM devices (multi-wire proportional cham-bers) provided by CERN. A MFD monitor of much smaller size (32 Al strips, 10  m wide with a 32  m pitch deposited onto a 20  m thick Si-wafer) has been designed and tested for the online control, positioning and focusing of 32 MeV alpha-particles for Single-Event-Upset studies of the BEETLE readout chip at the Tandem generator of the MPI für Kernphysik (Heidelberg). Figure 2. On-line MFD BPM performance at X7 test beam facility at CERN: 120 GeV  - beam with 5.2 * 10 5 particle per 2.4 s spill. Al C Ti W Ti Pd C C