Pressure measurements. INTRODUCTION Absolute pressure = Pgage + Patm. Atmospheric pressure = 100 KP a =14.7 Psi =1 0.2 m H 2 o =760 mm H g =760 torr.

Slides:



Advertisements
Similar presentations
Faradays Law of Induction A changing magnetic field induces an electric field. The induced electric field causes a current to flow in a conductor.
Advertisements

Measurements Measurement of Pressure Part 2d: Measurement of Pressure 1Process Instrumentation Lecture NotesMay-15.
Pressure Measurements
Chapter 16 Principles of Conventional Pressure transducers
Lecture 2: Pressure Measurements
Sensors Bryson Cook James Wyler Hao Phan 1. Outline Optical Encoders: Theory and applications –Types of encoders –Fundamental Components –Quadrature –Errors.
Fluid Mechanics Fluid Statics. Pressure field Pressure is a scalar field: p = p(x; y; z; t) The value of p varies in space, but p is not associated with.
Today’s class By the end of this class, you’re expected to learn
Pressure Sensors.
Pressure Measurement Muhajir Ab. Rahim
SENSORS AND TRANSDUCERS
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 14.1 Inductance and Magnetic Fields  Introduction  Electromagnetism  Reluctance.
Measuring Pressure. Atmospheric Pressure Recall: Caused by the weight of the air molecules above us. Typically kPa or Pa Measured using.
Lecture on Measurement of Non-Electrical Quantities
PRESSURE MEASUREMENT Low pr ( Below 1 mm of Hg)- manometer and low pr gauges Medium and low ( between 1mm of Hg 1000 atm)- Bourdon gauge and Diaphragm.
Sensors Chris Davidson Ari Kapusta Optical Encoders and Linear Variable Differential Transformers.
Principles of Physics Electromagnetic Induction. Changing magnetic fields can create a voltage (and thus cause current to flow) in a conductor A wire.
Unit 27 Transformers. Objectives –After completing this chapter, the student should be able to: Describe how a transformer operates. Explain how transformers.
Instructor: Lichuan Gui
CHAPTER 5: PRESSURE 5.1 Pressure and Its Units
1 Motion Sensors Displacement, velocity and acceleration.
Muhajir Ab. Rahim School of Mechatronic Engineering, KUKUM
EKT 451/4 SEM 2 Chapter 6 SENSOR & TRANSDUCER SHAIFUL NIZAM MOHYAR
Linear variable differential transducer (LVDT). The linear variable differential transducer (LVDT) is a type of electrical transformer used for measuring.
Measurement of Pressure Manometry
Introduction to Fluid Mechanics Engineering 1h Prof Bill Easson.
Atmospheres and Conversions: 1.00 atm = x 10 5 Pa = kPa = 760. Torr = 14.7 psi To convert pressure: 1.Turn what you have to atm 2.Multiply.
9AEI It is defined as the change of position of a body with respect to a reference It may be Linear motion Rotational motion Displacement.
Gauge pressure Most pressure gauges compare to Atmospheric (i.e. this room is at 0 Gauge) Absolute p is 1 atm more P = P gauge + 1 atm 1 atm = x.
Pressure measurements related to the fluid systems are the topic of this chapter. Absolute pressure refers to the absolute value of the force per unit.
Displacement and Motion Measurement
Hydrostatic Pressure Contents: How to calculate Whiteboards.
22.3 Inductance pp Mr. Richter. Agenda  Warm Up  Notes:  Mutual Inductance  Transformers.
Pressure measurement Prof.R.G.Telrandhe. Need of pressure measurement? Pressure? Differential quantity Different pressures and relationship between them.
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
Load Transformers These are electromagnetic devices which can ‘step up’ or ‘step down’ ac voltages. A 240 volt supply can be converted to (for example)
Lecture 4. Pressure. 4.1 Pressure and it units Pressure = “the normal (perpendicular) force per unit area” Pressure at the bottom of the static (nonmoving)
©1997 by M. Kostic Ch.9: Pressure & Velocity Measurements Pressure Concept:Pressure Concept: …it is an inward-normal force per unit (contact) area [N/m.
Capacitive transducers(cont’d):- The capacitance of this unit is proportional to the amount of area on the fixed plate that is convered, that is, "'shaded"
Transformers. November 30, 1876, the date of receipt of the patent Yablochkov Pavel Nikolayevich, is considered the date of birth of the first transformer.
Pressure Measurements
MEASUREMENT OF PRESSURE.. Shantilal shah engineering college. NAME:SARIYA ARTI ENROLL.NO: SUB:FLUID MECHANICS. BRANCH :CIVIL. SEM: 3 rd.
Displacement, Location or Position Sensor Muhajir Ab. Rahim School of Mechatronic Engineering, KUKUM.
1 Eeng 224 Chapter 13 Transformer Applications Huseyin Bilgekul Eeng224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern Mediterranean.
1 Transducers EKT 451 CHAPTER 6. 2 Definition of a Transducers   Transducer is any device that converts energy in one form to energy in another.  
TRANSDUCERS.
Pressure Measurement PI – I URVISH URVISH PI-I.
PRESSURE MEASUREMENT PART - I Er. FARUK BIN POYEN Dept. of AEIE, UIT, BU, BURDWAN, WB, INDIA
TRANSDUCERS PRESENTATION BY: ELECTRICAL ENGINEERING DEPARTMENT.
Electric Pressure Transducer
Pressure Measurements
Pressure Pressure is defined as the force exerted by a fluid per unit area. Units in SI are Pa=N/m2. The pressure unit Pascal is too small for pressure.
TRANSDUCERS PRESENTATION BY: Dr.Mohammed Abdulrazzaq
14.1 Introduction Earlier we noted that capacitors store energy by producing an electric field within a piece of dielectric material Inductors also store.
Measurement of Pressure , Velocity, Acceleration Mass and Weight
SVMIT ELECTRICAL Prepared By : - Rohan Kapadia (016)
Gases.
There are three parts of a transformer
Measurement of Pressure
Transformer -Types & Applications
I. Physical Properties (p )
Displacement, velocity and acceleration
What is a transformer? iron core secondary coil primary coil
Transformers A transformer changes the high voltage from the main power lines to the 120 volts your appliances use.
Group members K17CE10 K17CE49 K17CE12. Introduction Classification of pressure Pressure measurement instruments Mechanical gauges.
Measurement of Non-Electrical Quantities: Measurement of Pressure
LVDT You’re expected to learn
LVDT The LVDT's primary winding, P, is energized by a constant amplitude AC source. The magnetic flux thus developed is coupled by the core to the adjacent.
Pressure measurements
Unit-1 Transformer.
Presentation transcript:

Pressure measurements

INTRODUCTION Absolute pressure = Pgage + Patm. Atmospheric pressure = 100 KP a =14.7 Psi =1 0.2 m H 2 o =760 mm H g =760 torr.

Fig. 5.1 Relation between gauge, absolute, and atmospheric pressure

U-TUBE MANOMETER Fig.5.2. U-tube manometer

The difference between the unknown pressure and the atmospheric pressure is determined as a function of the differential height. Pa- P atm = ρgh Where Pa is the absolute measured pressure, P atm is the atmospheric pressure, ρ is the fluid density

BAROMETER As shown in Fig. 5.3, The well is exposed to atmosphere pressure. The height h is a measure of the atmospheric pressure. =10 5 P a

Fig Barometer

Fig Bourdon tube pressure gauge

ELECTRICAL PRESSURE TRANSDUCERS Pressure transducers are devices that convert pressure into an electrical signal. One of its type is "Displacement-type pressure gauge transducer", shown in Fig. 5.5.

Fig.5.5. Displacement pressure gauge transducer

One end of the bourdon tube is fixed. The other end is free to displace. The core of the LVDT is fixed to the free end of the bourdon tube. As pressure is applied to the bourdon tube, the core of the LVDT is pulled through the coil, and an output voltage proportional to the applied pressure is produced, Fig5.6.

Fig.5.6 LVDT output voltage versus its core displacement

5.5.1 Linear Variable Differential Transformer, LVDT Fig.5.7 schematic representation of the LVDT

LVDT consists of one primary coil and two secondary coils within which is placed an iron core. The primary coil is energizes by mean of an alternating current. An induced voltage is produced in the secondary coils by electromagnetic effect. The presence of the iron core enhances this effect. The secondary coils are connected in series opposition, so that when the core is centralized in the coils the produced voltage are equal and opposite. Subsequently the output voltage is zero. When the iron core is displaced from its central or null position, an imbalance in mutual inductance between the primary and secondary coils occurs, and an output voltage is developed proportional to the core displacement.