Selling Addressable Systems

Slides:



Advertisements
Similar presentations
EST3 Life Safety Platform
Advertisements

PRODUCT PRESENTATION QUANTUM2. EVOLIS QUANTUM, MODULAR SYSTEM FOR CENTRALIZED CARD PRODUCTION.
INTRUSION ALARM TECHNOLOGY
Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
ID to 8 Loop Intelligent Fire Alarm Panel
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Selling Addressable Systems: MS-9050UD
Remote Monitoring and Management Solutions ®
Medical Gas Alarm Panels
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Product Presentation. 2 Quantum2 - Product positioning  An innovative, unique and powerful solution.  The most modular printing and encoding system.
SafeLINC™ Fire Panel Internet Interface
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Precept Conventional Control Panels
Advantys® STB High Density Discrete I/O Modules. AGP - English 2 Advantys® STB Advantys STB delivers customer value in distributed I/O Smart Built-in.
ONYX Product Overview.
Chapter 14: Inspection and Maintenance
INTRUSION ALARM TECHNOLOGY
Addressable Fire Alarms
Chapter 13: Sharing Printers on Windows Server 2008 R2 Networks BAI617.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
Fire Detection Presentation
Networking & Integration
NOTIFIER® ONYX® Series Overview
Invision TAC™ Integrated Telephone Entry and Access Control System Product Introduction June 2010.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
ACCESS CONTROL ExpansE - Distributed Access Control.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Intelligent Control Panel SLC
Home Guard Security System. Introduction & Basic Ideas Home Guard Security System.
&. © 2013 Sensor Switch Combining Time-Based, Sensor- Based, Daylight-Based, & Manual Control, nLight provides an elegant solution for any control requirements.
NFS System Components & Installation.
2 December, 2015 New Conventional Fire Control Panel.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
1 THE COMPUTER. 2 Input Processing Output Storage 4 basic functions.
FIREPOWER BY SABURKE. Distributed Power Modules Model 5495Model Amps9 Amps.
New product introduction:
Selling Addressable Systems: MS-9600LS MS-9600LS Sales Presentation Product Overview MS-9600LS  Ideal for medium to large facilities  Two SLC Circuits.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Avaya 9130 and 9135 Online UPS 1000 to 6000 VA. Avaya Applications Advanced power protection for: u S8700/S8500/S8300/S8100 Media Servers u Unified Communications.
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC PUBLIC CO900H L06 - Developing Safety Applications Using the Guardmaster®
C1300 advanced circular chart recorder
High Security and Access Systems
Programmable Logic Controllers (PLCs) An Overview.

Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
FAST. FORWARD. TOGETHER! A Firelite Fire Alarm Panel by Honeywell
Presentation transcript:

Selling Addressable Systems MS-9050UD

Product Overview MS-9050UD Ideal for small to medium facilities Perfect for replacing conventional systems A single PC board, includes all electronics, 3 amp power supply, Built-in digital communicator Optional Internet Communicator (IPDACT) Converts DACT-UD signals to Ethernet Planned for January 2007 release (Pending UL)

Product Overview MS-9050UD Continued Easy to Install, Program and Use Meets many application requirements Features new larger enclosure with electronics on easy-to-remove chassis.

Product Overview Look and feel of larger FireLite addressable panels Menus and selections follow standard FireLite panels and reduce training required. Support for 50 addressable devices of any type on one signaling line circuit.

Product Overview MS-9050UD Continued Standard features: User-friendly LCD Display, 2 NAC circuits with built-in synchronization for System Sensor, Wheelock, and Gentex 3 Form-C relays standard Trouble (non-programmable) Alarm and Supervisory are programmable for other functions 3-amp power supply

Product Overview Programming Options From the front panel keyboard or PS-2 Keyboard A standard PC keyboard can be plugged into the board's PS-2 connector to facilitate keystrokes. From any computer serving as a programming terminal Requires Windows®-98 or greater, a modem and Fire-Lite's PK-CD Upload/Download software kit (available Q4, 2006) Information that can be retrieved includes: The History file Walk test data Current status and system voltages

Options ANN-80 Remote Annunciator Liquid Crystal Display 80-Character Display (4 lines 20 characters each) Provides complete event description Maximum of 8 per system, 6,000 feet max between each Permits remote displays at convenient building locations Switches for the remote execution of Acknowledge, Alarm Silence, Reset and Drill functions Permits system control from remote location Access controlled by key switch Prohibits unauthorized operation

Options ANN-I/O Lamp Driver module for interfacing with custom graphic annunciator displays Permits first responders/fire fighters to quickly locate devices in alarm EIA-485 6000 ft ANN-I/O Graphic Annunciator

Options Ann-S/PG Printer Gateway Allows serial or parallel printer to be placed anywhere on ANN-Bus 6,000 feet max from panel Permits remote printer at convenient building locations Supports new UL listed PRN-6F printer or any low-cost serial or parallel printer EIA-485 6000 ft

Options ANN-LED LED Annunciator module TR-CE Trim Ring Can be mounted in special dress panel DP-5150LED for applications where LED’s are required. TR-CE Trim Ring Continuous Metal trim ring dresses panel for flush mount up to hinge of panel door.

Options 4XTMF Transmitter Module Reverse Polarity Alarm and Trouble transmitter Permits connection to municipal central stations

Selling Strategies Target Markets (Who will Buy this System?) Smaller facilities including: - Apartment Complexes - Banks - Cinemas - Child Care and Elementary Schools - Department Stores - Food Stores - Places of Worship - Restaurants - Strip Malls - Small Retail Outlet Stores

Mid-Rise building targets Selling Strategies Mid-Rise building targets Buildings less than 75 feet in height: Dormitories Small Motels Small Hotels Extended Stay Facilities

Vertical Market targets Selling Strategies Vertical Market targets Commercial buildings including: Light Manufacturing Stand Alone Warehouse Telecommunication Systems Smaller Corporate Headquarters Healthcare including: Smaller Hospitals and Clinics Nursing Homes Retirement or Assisted Living Facilities

Selling Strategies Typical Customer Profiles (Who do I talk to?) Security or Facility Manager in a Small to Mid-Sized Business or Public Facility: Example: A building such as a small or elementary school or day care facility or place of worship. Building Owner or Contractor: Examples: A standalone department store or municipal building

Selling Strategies Qualifying Questions (Determine customer need and overcome objections.) How dispersed are the devices from the panel? The MS-9050UD's SLC loop can be up to 10,000 feet long. What type of building is it? (Motel, Assisted living, Department Store) A single MS-9050UD can support up to 50 devices of any type, detectors or modules. Built-in software logic zones can be programmed to meet any critical need.

Selling Strategies Are you constrained by budget limitation? For smaller applications, the MS-9050UD is a compact, cost effective Fire Alarm Built-in Control Panel/Communicator that provides large system technology and quality at a reasonable price.

Selling Strategies Selling Points Designed for small sized installations User-friendly interface for easier programming and maintenance Compliance - UL 864 (Fire), NFPA-72 and ULC Supports a wide range of addressable sensors: Photo, Ion, Beam, Heat detectors, Duct Detectors and all the SLC devices supported by FireLite’s larger products

Selling Strategies Selling Points (Continued) Supports a variety of notification devices such as: Horns and Strobes (including SpectrAlert Advance Selectable Output Series of strobes, horns/strobes and speaker/strobes) Integrates or retrofits existing conventional devices Drop in upgrade for MS-9200 Uses existing wire Uses existing intelligent devices

Features and Benefits FEATURE BENEFIT One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6, or 7. The MS-9050UD's 1-loop system supports 50 devices of any type. Standard 80-character LCD backlit display, (4 lines x 20 characters). Easy to Use and very intuitive. Allows programming without any additional hardware required. Four (4) Notification Appliance Circuits (NACs) rated at 2.5 amps with Synchronization for System Sensor, Wheelock, and Gentex devices. Built-in synchronization allows conforming to present day code requirements without need for additional hardware or labor.

Features and Benefits FEATURE BENEFIT Fully programmable from local keypad, local PS-2 keyboard or PC via PK-CD Windows® utility. The MS-9050UD is easy to configure and is 100% programmable either locally or remotely. Auto-programming The MS-9050UD has the capability to identify devices by detector or module type to establish fire protection across the entire facility within minutes.

Features and Benefits FEATURE BENEFIT Programmable Sounder/Relay Base Provides added functionality by selectively isolating notification local alarms without having to evacuate the entire building. Permits verification of actual alarm, therefore offering cost savings in equipment, labor and time. Remote Programming and Monitoring Permits upload/download of system programming information as well as verification of system parameters, including detector sensitivity without having to leave your office.

Key Applications Department Store Example

Additional Benefits Why sell Addressable over Conventional? Lower Wiring Costs Shortened Installation Schedule Greater Device Supervision Superior Troubleshooting Rapid and direct identification of the fire threat Simplified fire design and layout

Conventional Fire Panel Lower wiring costs Conventional VS Addressable Conventional Fire Panel MS-9050UD

Shortened installation schedule Less cabling Less conduit Less hardware Greater flexibility via software Elevator recall HVAC shutdown Access control override

Greater device supervision Device presence Is it there or not? Device condition Functional or not Clean vs Dirty Alarm Trouble Type of Device Smoke detector, pull station, etc.

Superior troubleshooting Detailed trouble messages Pinpointed device location Individual walk testing Maintenance warnings Alert Urgent Failed Automatic Test

Rapid and direct identification of fire threat Advanced notice of pending condition (pre-signal) Detailed alarm messages Specific threat location with label

Single SLC Simplifies System Design HVAC Elevator Control

Compatible Intelligent Detectors AD355 Adapt Multicriteria Smoke Detector SD355 Photoelectric Smoke Detector SD355T Photoelectric w/Thermal CP355 Ionization Smoke Detector H355 Fixed Thermal Detector H355R Fixed Thermal w/Rate-of-Rise Separate B350LP base (with each head) D350P Photoelectric Smoke Duct Detector D350RP Photoelectric Smoke Duct Detector with Auxiliary Relay SD355 CP355 H355 D350PL

Intelligent Detectors AD355 Adapt™ Multicriteria Detector Automatically adjusts sensitivity levels without the need for operator intervention or programming. Sensitivity increases with heat. Combination photo and thermal technology. Alarm verification The intelligent fire sensor that never stops learning.

Intelligent Detectors Rotary switches for setting address 00-99 Easy to set in field with screwdriver No programming tools required Easy to identify address

Addressable Input Modules MMF-300 Monitor Module For monitoring a circuit of normally-open contact conventional alarm initiating devices MMF-302 Monitor Module For monitoring 2-Wire Smoke Detectors (requires filtered resettable 24 volts) Can be used to retrofit conventional systems to Addressable without costly detector replacement MDF-300 Dual Monitor Module For monitoring normally-open contact alarm initiating devices. NFPA Style B only Assumes two sequential addresses on the SLC Provides convenience for monitoring two doors or HVAC fans/dampers and other normally open contacts.

Addressable Input Modules MMF-300-10 Ten Class B Initiating Device Circuits MMF-302-6 Six Class B or Three Class A Initiating Device Circuit Module for Monitoring UL Listed two-wire smoke detectors (requires filtered resettable 24 volts) Both modules provide high density packages for monitoring multiple devices in a small space Mounts in BB-2F or BB-6F backboxes

Addressable Input Modules The BB-2F will hold 2 cards (as shown). The BB-6F w/CHS-6 will hold up to 6 cards

Addressable Input Modules MMF-301 Mini-Monitor Module For monitoring a single conventional, contact-type device in the same mounting box NFPA Style B only No polling LED

Addressable Input Modules BG-12LX Addressable Pull Station Key Resettable Prevents unauthorized reset Dual Action Prevents accidental activation Polling LED viewable through front handle Reassures owner system is active

Addressable Output Modules CMF-300 NAC Control Module NFPA Style Y (Class B)/Style Z (Class A) 24 VDC power must be supplied 3-amp maximum load capability Permits system software control of distributed NAC power supplies Programmable for the following: Auto-Silence (timed sounder cutoff) Silence Inhibit Silenceable vs. Non-Silenceable Enable/Disable

Addressable Output Modules CRF-300 Relay Control Module Two Form-C Relays that work in unison. Use for elevator recall, damper control, door holding, auxiliary control functions, etc. No tabs to break Easy to install Address can be set by simply removing front dress cover

Addressable Output Modules CMF-300-6 Six Class B or Three Class A Notification Appliance Circuits High Density package for multiple NAC control circuits CRF-300-6 Six Form-C Contacts Provides high density package for multiple relay control functions Mounts 2 in BB-2F or 6 in BB-6F backboxes

MS-9050UD Summary Ease of installation and programming Faster setup reduces number of man hours required per system Individual point reporting through communicator provides accurate location to first responders Two synchronized NACs for System Sensor, Wheelock, and Gentex devices Allows connection to different devices on separate circuits for easier and less-costly retrofit

MS-9050UD Summary Three Form-C relays standard Trouble (non-programmable) Alarm and Supervisory are programmable for other functions Programmable from internal keypad, a PS2 keyboard or a personal computer

MS-9050UD Summary Provides advanced maintenance and troubleshooting Auto Detector testing (no special tools or tester required) Drift Compensation Maintains alarm window as detector becomes dirty Maintenance Alert Alerts when detectors need to be cleaned Auto device type validation Immediately identifies what is connected to the panel for faster setup

Thank You