Multi Phase Meter Arvand Azin Aryan
Agenda What is multiphase meter Operating principle Multiphase advantages Fluid operation range What companies using multiphase? Operation example Accessories List Application data sheet Third generation Arvand Azin Aryan
What is Multiphase meter? The Multiphase meter Technology is the combination of the robust concept of Venturi and well known and unique measurement of Multi-Energy Gamma Ray to replace conventional well testing Arvand Azin Aryan
Measures fraction and velocity of oil fraction and velocity of water fraction and velocity of gas Outputs Oil rate Water rate Gas rate Arvand Azin Aryan
Multiphase meter - Topside Arvand Azin Aryan
Multiphase meter - Topside Arvand Azin Aryan
Gamma-rays detector Ba133 source Venturi Flow ΔPΔP Venturi Total mass flow rate (Bernoulli) Source and detector 3 phases fractions (nuclear attenuatio) PVT model Convert from line to standard conditions Output -> Oil, Gas, Water flowrates at standard conditions Arvand Azin Aryan
Q total mass = q total vol. * mixture = v * A * Mass Flow rate = (Volumetric Flow rate) (Mixture Density) = (Mixture Velocity ) (Venturi Throat Area) (Mixture) Density Arvand Azin Aryan
Principle of calculation Arvand Azin Aryan
Venturi & Delta P Source & Detector Single- phase rates Multiphase* Technology – Calculations overview Arvand Azin Aryan
Technology Overview and advantages No phase separation, No moving parts No tuning factor, No flow calibration WLR is not phase distribution dependent Different sizes: 29, 52, 65, 88 (150 – 150,000 bpd) No Sensor in direct contact with the fluid Actual measurement at production conditions Low Differential Pressure Design No stabilization required Compact Solution Arvand Azin Aryan Sep. 2015
Features and Benefits Operation efficiency and safety Compact, lightweight & small footprint Limited pressure test lines Simple equipment mobilization Reduced crew Short operation duration, saving rig time and reducing flaring fast rig-up and rig down clean-up optimization no stabilization time required On line, continuous production monitoring No moving part (low failure probability) Data quality & Metrological performance Improved accuracy vs. conventional testing High repeatability Independent of flow regimes Exceptional dynamic response Flow rate measurements during all clean- up Early water detection Not affected by slugs, foam and emulsion Unique hardware for heavy oil, black oil, volatile oil, gas condensate, wet gas and dry gas well testing Reduce the Operation cost Arvand Azin Aryan
Fluid Range Operated up to now Arvand Azin Aryan line conditions
Arvand Azin Aryan
Multiphase Connecting points from production line to test line Inlet Manifolds of Wells Arvand Azin Aryan
Deference in GVF and WLR H18H8+H18 Arvand Azin Aryan
H18 H18+H8 Arvand Azin Aryan
Well head parameters during the test Arvand Azin Aryan
Deference in flow rates H18 H8+H18 Arvand Azin Aryan
Results We can subtract H8 oil Q= =181.9 STB/d, gas Q= =21.51 MScf/d, water Q= = STB/d. BSW=590.86/( )=78% Arvand Azin Aryan
Ratios Arvand Azin Aryan
Well production Operating point Arvand Azin Aryan
Multiphase meter Bypass manifold Chock manifold ESD panel Gas manifold Lab cabin SSV Data header Pipes and elbows Accessories List
Arvand Azin Aryan Application data sheet
Arvand Azin Aryan Third generation
Arvand Azin Aryan
Address: Unit No. 11, No.17, Behruz St., Madar Sq., Mirdamad Ave., Tehran, Iran Tel: Fax: Website: