Fundamentals of Electric Circuits Chapter 19 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Slides:



Advertisements
Similar presentations
Feedback of Amplifier Circuits I
Advertisements

The University of Tennessee Electrical and Computer Engineering
TWO-PORT NETWORKS In many situations one is not interested in the internal organization of a network. A description relating input and output variables.
Circuits II EE221 Unit 8 Instructor: Kevin D. Donohue 2 Port Networks –Impedance/Admittance, Transmission, and Hybird Parameters.
دو قطبي ها-1 مدار 2 پائيز 86 دكتر توحيدخواه.
Two-port networks Review of one ports Various two-port descriptions
CHAPTER 6 TWO PORT NETWORKS.
Lecture 6. Chapter 3 Microwave Network Analysis 3.1 Impedance and Equivalent Voltages and Currents 3.2 Impedance and Admittance Matrices 3.3 The Scattering.
Chapter 2 Waveguide Components & Applications
Chapter 2 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fundamentals of Electric Circuits Chapter 10 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
EE2003 Circuit Theory Chapter 2 Basic Laws
Network Theorems SUPERPOSITION THEOREM THÉVENIN’S THEOREM
ELCT564 Spring /2/20151ELCT564 Chapter 4: Microwave Network Analysis.
EKT 441 MICROWAVE COMMUNICATIONS
Chapter 3 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
4 Series Circuits Chapter Topics Covered in Chapter 4
Chapter 4 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fundamentals of Electric Circuits Chapter 11
Fundamentals of Electric Circuits Chapter 9
Chapter 18 Two-port Networks.
EMLAB 1 Chapter 5. Additional analysis techniques.
ECE 352 Electronics II Winter 2003 Ch. 8 Feedback 1 Feedback *What is feedback?Taking a portion of the signal arriving at the load and feeding it back.
ENE 490 Applied Communication Systems Lecture 3 Stub matching, single- and two-port networks DATE: 27/11/06.
Applied Circuit Analysis Chapter 4 - Series Circuits Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fundamentals of Electric Circuits Chapter 9 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Block A Unit 3 outline One port network Two port network
Fundamentals of Electric Circuits Chapter 19
ECE 352 Electronics II Winter 2003 Ch. 8 Feedback 1 *Feedback circuit does not load down the basic amplifier A, i.e. doesn’t change its characteristics.
Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display. 1 Chapter 5 Handy Circuit Analysis Techniques.
Chapter 13 Magnetically Coupled Circuits
Fundamentals of Electric Circuits Chapter 16 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fundamentals of Electric Circuits Chapter 9
TWO PORT NETWORKS.
Fundamentals of Electric Circuits Chapter 13 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fundamentals of Electric Circuits Chapter 5 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Unit 8 Phasors.
Fundamentals of Electric Circuits Chapter 10 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Circuit Theory Chapter 2 Basic Laws
TWO-PORT NETWORKS.
Lecture - 10 Two port circuits
Fundamentals of Electric Circuits Chapter 4
Two-Port Networks Chapter 19.
Applied Circuit Analysis Chapter 12 Phasors and Impedance Copyright © 2013 The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Fundamentals of Electric Circuits Chapter 1 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
EKT 441 MICROWAVE COMMUNICATIONS CHAPTER 3: MICROWAVE NETWORK ANALYSIS (PART 1)
EMLAB Two-port networks. EMLAB 2 In cases of very complex circuits, observe the terminal voltage and current variations, from which simple equivalent.
1 Fundamentals of Electric Circuits Chapter 2 Basic Laws Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Small Signal – Low Frequency Transistor amplifier Circuits UNIT-IV.
1 TWO PORT NETWORKS CHAPTER 6. 2 OBJECTIVES To understand about two – port networks and its functions. To understand the different between z- parameter,
Lec 1. Two-Port Circuit Mr.Mohamed Elshaikh. What today?? ● Introduction ● The concept of two-port circuit ● The terminal equations ● Two-port parameters.
ELEC 401 MICROWAVE ELECTRONICS Microwave Networks - Parameters
Two-Port Networks-1 D.C. Kulshreshtha मंगलवार, 23 जनवरी 2018
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits Chapter 2
ELECTRIC CIRCUITS EIGHTH EDITION
ELECTRIC CIRCUITS EIGHTH EDITION
Two-Port Network Parameters
EKT 356 MICROWAVE COMMUNICATIONS
Alexander-Sadiku Fundamentals of Electric Circuits
CHAPTER 1 TWO PORT CIRCUITS
Two-port networks Adam Wąż
Fundamentals of Electric Circuits Chapter 16
Two-Port Networks Equivalent Circuits
NETWORK FILTERS AND TRANSMISSION LINE.
Fundamentals of Electric Circuits Chapter 2
Fundamentals of Electric Circuits Chapter 5
SABIKA FATIMA EEE NETWORK THEORY B.TECH II YR I SEM
CHAPTER 59 TRANSISTOR EQUIVALENT CIRCUITS AND MODELS
Presentation transcript:

Fundamentals of Electric Circuits Chapter 19 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Overview The concept of a two-port network. The relationship between input and output current and voltages. Combinations of networks in series, parallel, and cascaded. 2

Figure 19.1

Two Port Network A two port network is an electrical network with two separate ports for input and output. The two port network has terminal pairs acting as access points. This means that the current entering one terminal of a pair leaves the other terminal in the pair. Three terminal devices, such as transistors can be configured as two port devices. 4

Parameters To characterize a two-port network requires that we relate the terminal quantities V 1, V 2, I 1, and I 2. Out of these only two are independent. The terms that relate to these voltages and currents are called parameters. Impedance and admittance parameters are commonly used in the synthesis of filters. They are also important in the design and analysis of impedance-matching networks and power distribution networks. 5

Impedance Parameters A two-port network may be either voltage driven or current driven The terminal voltages can be related to the terminal currents as: 6

Impedance Network II The values of the parameters can be evaluated by setting the input or output port open circuits (i.e. set the current to zero). These are referred to asthe open-circuit impedance parameters. 7

Open Circuit Parameters These parameters are as follows: z 11 Open circuit input impedance z 12 Open circuit transfer impedance from port 1 to port 2 z 21 Open circuit transfer impedance from port 2 to port 1 z 22 Open circuit output impedance When z 11 =z 22, the network is said to be symmetrical. 8

z Parameters When the network is linear and has no dependent sources, the transfer impedances are equal (z 12 =z 21 ), the network is said to be reciprocal. This means that if the input and output are switched, the transfer impedances remain the same. Any two-port network that is composed entirely of resistors, capacitors, and inductors must be reciprocal. 9

Figure 19.4

z Parameters II It should be noted that an ideal transformer has no z parameters. The equivalent circuit for two port networks is shown below: 11

Example 12

Example 13

Example 14

Admittance Parameters If impedance parameters do not always exist, then an alternative is needed for these cases. This need can be met by expressing the terminal currents in terms of terminal currents: The y terms are known as admittance parameters. 15

y Parameters. The y parameters can be determined by short circuiting either the input or output ports (thus setting their voltages to zero). Because of this, the y parameters are also called the short circuit admittance parameters. 16

Figure 19.12

Short Circuit Parameters These parameters are as follows: y 11 Short circuit input admittance y 12 Short circuit transfer admittance from port 1 to port 2 y 21 Short circuit transfer admittance from port 2 to port 1 y 22 Short circuit output admittance The impedance and admittance parameters are collectively called the immitance parameters. 18

Equivalent Circuit For a network that is linear and has no dependent sources, the transfer admittances are equal. A reciprocal network (y 12 =y 21 ) can be modeled with a  -equivalent circuit. Otherwise the more general equivalent network (right) is used. 19

Example 20

Example 21

Example 22

Hybrid Parameters Sometimes the z and y parameters do not always exist. There is thus a need for developing another set of parameters. If we make V1 and I2 the dependent variables: 23

Hybrid Parameters II The h terms are known as the hybrid parameters, or simply h-parameters. The name comes from the fact that they are a hybrid combination of ratios. These parameters tend to be much easier to measure than the z or y parameters. They are particularly useful for characterizing transistors. Transformers too can be characterized by the h parameters. 24

Values The values of the parameters are: The parameters h 11, h 12, h 21, and h 22 represent an impedance, a voltage gain, a current gain, and an admittance respectively. 25

h Parameters The h-parameters correspond to: h 11 Short circuit input impedance h 12 Open circuit reverse voltage gain h 21 Short circuit forward current gain h 22 Open circuit output admittance In a reciprocal network, h 12 =-h 21. The equivalent network is shown below: 26

Example 27

Example 28

g Parameters A set of related parameters are the g parameters. They are also known as the inverse hybrid parameters. They are used to describe the terminal currents and voltages as: 29

g Parameters II The values of the g parameters are determined as: The equivalent model is shown below: 30

g Parameters The g parameters correspond to: g 11 Open circuit input admittance g 12 Short circuit reverse current gain g 21 Open circuit forward voltage gain g 22 Short circuit output impedance 31

Transmission Parameters Since any combination of two variables may be used as the independent variables, there are many possible sets of parameters that may exist. Another set relates the variables at the input and output 32

Example 33

Example 34

Transmission Parameters II Note that in computing the transmission parameters, I 2 has a minus sign because it is considered to be leaving the network. This is done by convention; when cascading networks it is logical to consider I 2 as coming out. The transmission parameters are: 35

Transmission Parameters III The transmission parameters correspond to: A: Open circuit voltage ratio B: Negative short circuit transfer impedance C: Open circuit transfer admittance D: Negative short circuit current ratio A and D are dimensionless while B is in ohms and C is in siemens. These are also known as the ABCD parameters. 36

Example 37

Example 38

Inverse Transmission Parameters We can also derive parameters based on the relationship of the input to the output variables. These inverse transmission parameters are: 39

t Parameters The inverse transmission parameters, also called t parameters, correspond to: a: Open circuit voltage gain b: Negative short circuit transfer impedance c: Open circuit transfer admittance d: Negative short circuit current gain a and d are dimensionless while b is in ohms and c is in siemens. 40

Table 19.01

Interconnections of Networks Often it is worthwhile to break up a complex network into smaller parts. The sub-network may be modeled as interconnected two port networks. From this perspective, two port networks can be seen as building blocks for constructing a more complex network. These connections may be in series, parallel, or cascaded. 42

Series Connection Consider the series connected network shown here. They are considered to be in series because their input currents are the same and their voltages add. The z parameter for the whole network is: 43

Parallel Connection Two port networks are in parallel when their port voltages are equal and the port currents of the larger network are the sums of the individual port currents. Consider the network shown. Here, the y parameters of the entire network are: 44

Cascaded Connection A cascaded series of networks at first glance appears to be a series connected system. But note, that here, the output of one network is directly sent into the input of another network. Consider the cascaded network below: 45

Cascaded Networks Understanding the output of a cascaded system requires considering the flow of a signal through the system. A signal enters the first two port network and is changed by the transmission characteristics. This altered signal then enters the next two- port network and is again altered by its transmission properties. Thus the overall transmission is: 46