Physics Activities at CAPP, Korea Yannis Semertzidis CAPP/IBS at KAIST

Slides:



Advertisements
Similar presentations
Center for Axion and Precision Physics Strong CP-problem Axion dark-matter experiment; solar axions Proton Electric Dipole Moment experiment Muon g-2 experiment,
Advertisements

U.S. Department of Energy Brookhaven Science Associates BNL’s Role in High Energy Physics Thomas B.W. Kirk Associate Director for High Energy and Nuclear.
AN ANOMALOUS CURVATURE EXPERIMENT Carol Y. Scarlett Brookhaven National Laboratory Apr. 27 th, 2006.
Another Route to CP Violation Beyond the SM – Particle Dipole Moments Dave Wark Imperial/RAL WIN05 Delphi June 10, 2005.
Philip Harris University of Sussex (for the EDM Collaboration) The Neutron EDM Experiments at the ILL.
B. Lee Roberts, PANIC05, Santa Fe, 27 October, p. 1/35 Muon (g-2) Status and Plans for the Future B. Lee Roberts Department of Physics Boston University.
B. Lee Roberts, HIFW04, Isola d’Elba, 6 June p. 1/39 Future Muon Dipole Moment Measurements at a high intensity muon source B. Lee Roberts Department.
PEDM Review 12/7/091 Beam Position Monitors William Morse.
Are we ready yet? Where we are. What’s missing. Opportunities for new colleagues/collaborators How long will it take? 29 April 2015 BLV2015 meeting UMASS,
Axion dark matter search:
Development of Superconducting Magnets for Particle Accelerators and Detectors in High Energy Physics Takakazu Shintomi and Akira Yamamoto On behalf of.
Electric Dipole Moment Goals and “New Physics” William J. Marciano 12/7/09 d p with e-cm sensitivity! Why is it important?
17 March 2005Edda Gschwendtner1 MICE Cooling Channel: Can we predict cooling to ? Edda Gschwendtner Challenge Systematics Cooling Channel Beam Line.
Superconducting Magnet Division Ramesh Gupta High Field Magnet R&D with YBCO July 26, 2011Slide No. 1 EUCARD2 VIDEO CONFERENCE.
1 A Joint Proposal for US-Japan Cooperation Program Proposal to JSPS US-Japan collaboration fund R&D of superconducting magnet technology for high intensity.
 A GEANT4-based simulation was performed of the production target, solenoid, selection channel, and spectrometer.  The acceptance was found to be 8.3x10.
Conveneers: M. Grassi (INFN, Pisa), K. Ishida (RIKEN), Y. Semertzidis (BNL) Summary of WG4, Part Two. Yannis Semertzidis, BNL 1 August, 2004 Most muon.
Flavor Beyond Standard Model G.G. Devidze High Energy Physics Institute of Tbilisi State University 1.Introduction 2.Flavor beyond the standard model 3.Heavy.
1 Status of EMMA Shinji Machida CCLRC/RAL/ASTeC 23 April, ffag/machida_ ppt & pdf.
Vistas in Axion Physics April 2012 ADMX Cavities at higher and lower frequencies C. Hagmann, J. Hoskins, I. Stern, A.A. Chisholm, P. Sikivie, N.S. Sullivan,
Mitglied der Helmholtz-Gemeinschaft July 2015 | Hans Ströher (Forschungszentrum Jülich) EPS Conference on High Energy Physics, July 2015, Vienna.
Energy calibration at LHC J. Wenninger. Motivation In general there is not much interest for accurate knowledge of the momentum in hadron machines. 
How do we test that we are ready? Several simulation packages can do impressive spin/beam dynamics tracking We need to set benchmarking goals to control.
+ - Status of the proton EDM experiment at BNL Yannis K. Semertzidis Brookhaven National Laboratory Motivation Neutron EDM experiments Status of Storage.
+ - Concluding remarks on the R&D for a Magic Proton Ring for e  cm. Yannis K. Semertzidis, BNL The bottom line Funding request Possible action.
G-2 accelerator and cryo needs Mary Convery Muon Campus Review 1/23/13.
CP-Violation and Baryon Asymmetry in Universe Electric Dipole Moments of Fundamental Particles Yannis K. Semertzidis Brookhaven National Lab Colloquium.
CERN Report (II) Rolf-Dieter Heuer ECFA Meeting Frascati 1 July
Cavities and Magnets Working Group Darin Kinion (LLNL) 4/26/2012.
B Grants-in-aid KIBAN-B (FY2014~) Magnetic Dipole Moment g-2 Electric Dipole Moment EDM Utilize high intensity.
Harold G. Kirk Brookhaven National Laboratory High-Field Solenoids for a MC Final Cooling System AAC 2012 Austin, Texas June 11-15, 2012.
+ - The proton EDM experiment in a purely Electric field storage ring Yannis K. Semertzidis, BNL Motivation of “Magic” pEDM with Sensitivity: e.
G-2, EDM, COMET muon particle physics programmes at J-PARC Mu_01 Satoshi MIHARA IPNS, KEK FKPPL-FJPPL workshop, Yonesei Univ.
Muon Collider R&D Plans & New Initiative 1.Introduction 2.Muon Collider Schematic 3.Conceptual Breakthrough 4.Ongoing R&D 5.Muon Collider Task Force 6.Muon.
Status and Highlights of the Applied Superconductivity Center ASC established itself as a fully functioning center within the MagLab Raised $9M.
Electric dipole moments (EDM) experiments Making progress in
Douglas Bryman University of British Columbia APS May 3, 2011.
Electric dipole moment searches E.A. Hinds Birmingham 11 th July 2011 Centre for Cold Matter Imperial College London.
Results and perspectives of the solar axion search with the CAST experiment Esther Ferrer Ribas IRFU/CEA-Saclay For the CAST Collaboration Rencontres de.
 A model of beam line built with G4Beamline (scripting tool for GEANT4)  Simulated performance downstream of the AC Dipole for core of beam using  x.
John Womersley 1/13 Fermilab’s Future John Womersley Fermilab May 2004.
M. Garcia-Sciveres July 2002 ATLAS A Proton Collider Detector M. Garcia-Sciveres Lawrence Berkeley National Laboratory.
+ - EDM-review meeting BNL, 7 & 8 December 2009
1) Status of the Muon g-2 Experiment 2) EDM Searches in Storage Rings Yannis K. Semertzidis Brookhaven National Lab Muon g-2 Collaboration and EDM Collaboration.
Steering Group Meeting 10:30 – 12:30 am CDT Monday, July 23, 2007 Y2K.
A possible way to measure the deuteron EDM at COSY (A precursor to the dedicated EDM ring at IKP FZJ) W.Morse (BNL), N.Nikolaev (IKP FZJ & Landau Inst)
Yannis K. Semertzidis Brookhaven National Laboratory HEP Seminar SLAC, 27 April 2004 Muon g-2: Powerful Probe of Physics Beyond the SM. Present Status.
Derek F. Jackson Kimball. Collaboration Dmitry Budker, Arne Wickenbrock, John Blanchard, Samer Afach, Nathan Leefer, Lykourgas Bougas, Dionysis Antypas.
Marc Vanderhaeghen 1 Introduction LEPP16 Marc Vanderhaeghen LEPP16 Workshop Kupferberg, Mainz, April 4-7, 2016 New Vistas in Low-Energy Precision Physics.
The experiment and prospects Ready to write a CDR for e-cm DOE visit to finalize the development plan Opportunities for CERN 13 February 2015 FCC.
Electric Dipole Moment of the Deuteron Experiment: EDM Violates T-Symmetry: Connected to CP-Violation and the Matter-Antimatter Asymmetry of the Universe.
1 Muon g-2 Experiment at BNL Presented by Masahiko Iwasaki (Tokyo Institute of Technology) Akira Yamamoto (KEK) for E821 g-2 Collaboration: Boston, BNL,
EuCARD-2 is co-funded by the partners and the European Commission under Capacities 7th Framework Programme, Grant Agreement Highlights and roadmap.
Ultra-Cold Neutron Group in Kellogg Lab - Neutron Electric Dipole Moment (EDM) Experiment - Search for new CP violation - Neutron Decay - Precision measurements.
Yannis K. Semertzidis Brookhaven National Laboratory New opportunities at CERN CERN, 12 May 2009 Storage Ring EDM Experiments The storage ring method can.
Status of Polarimeters and Polarized Targets: what are the plans for development of polarized targets to meet the needs of the Day 1 and future experimental.
– + + – Search for the μEDM using a compact storage ring A. Adelmann 1, K. Kirch 1, C.J.G. Onderwater 2, T. Schietinger 1, A. Streun 1 1 Paul Scherrer.
ICNPF 2013, Crete, Aug. 28 – Sept. 5, 2013 JEDI - The Jülich Electric Dipole Moment Investigations in Storage Rings | H. Ströher.
Neutron and electron electric dipole moments
PBC EDM subgroup Yannis Semertzidis, CAPP/IBS and KAIST
Electric Dipole Moments: Searches at Storage Rings
Storage ring EDM experiments Yannis Semertzidis, CAPP/IBS and KAIST
Multiple-Cavity Detector for Axion Search
Electric Dipole Moments: Searches at Storage Rings
Renzo F. Parodi INFN-Genova
Strong Coupling of a Spin Ensemble to a Superconducting Resonator
I Alexander Nass for the JEDI collaboration
Search for Electric Dipole Moments: The JEDI-Project at Jülich
electric dipole moments (EDM)
Qingjin XU Institute of High Energy Physics (IHEP),
Presentation transcript:

Physics Activities at CAPP, Korea Yannis Semertzidis CAPP/IBS at KAIST 4 July 2014 PATRAS WORKSHOP, CERN Physics Activities at CAPP, Korea Yannis Semertzidis CAPP/IBS at KAIST Strong CP-Problem Axion dark matter search: State of the art axion dark matter experiment in Korea Collaborate with ADMX, CAST… Proton Electric Dipole Moment Experiment Storage ring proton EDM Muon g-2, mu2e, etc.

Axion dark matter hunters at KAIST CAPP axion-dark matter group, 2014 (Five additional scientists are either already in CAPP or have signed up.) http://capp.ibs.re.kr/html/capp_en/

Center for Axion and Precision Physics Research: CAPP/IBS at KAIST, Korea Four groups 15 research fellows, ~20 graduate students 10 junior/senior staff members, Visitors Engineers, Technicians Promised: New IBS building at KAIST

Axion dark matter: Imprint on the vacuum since the Big-Bang! Animation by Kristian Themann

Axion dark matter is partially converted to a very weak flickering Electric (E) field in the presence of a strong magnetic field (B). Animation by Kristian Themann

P. Sikivie’s method: Axions convert into microwave photons in the presence of a DC magnetic field (Primakov effect) a X Detector

Effect of cavity quality factor J. H., J.E. Kim, S. Nam, YkS hep-ph: 1403.1576

The conversion power on resonance The axion to photon conversion power is very small, a great challenge to experimentalists.

What’s there to improve? B2, Q, Ampl. noise/physical temperature, V. Magnetic field B: Develop 25T, 10 cm inner bore, 50cm long magnet. 35T, 5cm inner bore, 50 cm long magnet based on high Tc.

(CAPP) Axion dark matter plan, 1 We have started an R&D program with BNL for new magnets: goal 25T, 10cm diameter; then 35T, 5cm diameter. Currently all axion experiments are using <10T. Based on high Tc cables (including SUNAM, a Korean cable company). ~5 year program.

Magnet Development plan Already signed an agreement for a prototype magnet development between CAPP/IBS and BNL. Duration 1 year. Goal: Determine the cable for the final design. Spring 2014

What’s there to improve? B2, Q, Noise temperature/physical temperature, V. Copper cavity Q: ~105, axion Qa: ~3x106 Goal: Q: ~107, potential gain factor: 30. V: Torroid cavities; several cavities simultaneously (first ADMX attempt in the 90’s)

Axion dark matter plan, 2 We have started an R&D program to achieve large Q in the presence of large B-fields. Presently: Q~105 copper cavities. Aiming for ~107.

Improving the quality factor Q Superconducting vertical walls (ADMX). Parallel magnetic field Br < 100Gauss. Top and bottom walls perp. to magnetic field. R&D at KAIST to bypass the problem. Do we need top/bottom cavity walls? Open cavity with high-Q dielectric. R&D at KAIST. Toroidal cavity (no end walls!); work at KAIST.

Proposal of Cryogenic STM Research Group (Jhinhwan Lee/KAIST and CAPP) Enhancement of the High Tc Superconductors by Novel Vortex Engineering Our Idea: Each Ion Implantation Site Designed to Hold Multiple Vortices for High Field Applications 이 동영상에서는 각각의 에너지에서 왼쪽에 전자 파동의 공간적인 분포를, 오른쪽에는 이를 FT하여 밴드 구조 정보로 보여드리고 있습니다. Special Anodized Alumina Masks are to be used for Ion Implantation Lorentz Microscopy Visualization of Distributed Vortices on BSCCO

Axion dark matter plan, 3 We have started a development program with KRISS to provide us with (near) quantum noise limited SQUID amplifiers in the 1-10 GHz range. Evaluate method for higher frequency. 5 year program. Physical temperature: aiming for 30mK (Q.L.: 50mK at 1GHz).

Outsourcing: SQUID amplifiers from KRISS

Electric field simulation of a TM010 mode in a toroidal cavity Axion dark matter plan, 4 Large volume for low frequencies (e.g., Tokamaks). Critical issue is temperature. Very expensive. Opportunity for large collaborations. Electric field simulation of a TM010 mode in a toroidal cavity

Advantages of a toroidal cavity: Large volume gain >10x, great B2V. B-field tangential to cavity walls, i.e., cavity walls can be super-conducting. Quality factor gain >10x Low frequencies accessible, noise temp. possible but an engineering challenge Opportunities to discover axion dark matter at below 10% dark matter level.

Storage Ring Proton EDM: study of CP-violation beyond the Standard Model

Measuring an EDM of Neutral Particles H = -(d E+ μ B) ● I/I d E B µ mI = 1/2 ω2 ω1 mI = -1/2 d = 10-25 e cm E = 100 kV/cm w = 10-4 rad/s 

Proton storage ring EDM experiment is combination of beam + a trap

Yannis Semertzidis, CAPP/IBS, KAIST Stored beam: The radial E-field force is balanced by the centrifugal force. E Yannis Semertzidis, CAPP/IBS, KAIST Yannis Semertzidis, BNL 23

What’s the breakthrough? Statistics: 1011 polarized protons per cycle in a well behaved beam! Method: applying g-2 techniques. Maximize EDM sensitivity, minimize systematic errors. First stage goal: 10-29ecm, >3 orders of magnitude improvement over present nEDM. Probing Baryogenesis.

A Storage Ring Proton EDM experiment An experiment to measure proton EDM to 10-29ecm, revolution in statistics: 1011 pol. Protons per cycle. Most sensitive, flavor-conserving CP-violation probe Complementary to LHC; probes New Physics ~102-103 TeV Based on the “muon g-2” experience using the magic momentum technique with electric fields R&D issues resolved: 1) Polarimeter stat. & syst., 2) Spin Coherence Time understanding, 3) Electric field strength & fringe-field effects. On going R&D: SQUID-based beam position monitors (CAPP/IBS, KAIST, KRISS/Korea, Garching/Germany)

The Proton EDM experiment status Support for the proton EDM: CAPP/IBS, KAIST in Korea, R&D support for SQUID-based BPMs, Prototype polarimeter, Spin Coherence Time (SCT) simulations. COSY/Germany, studies with stored, polarized beams. DOE-HE requested a white paper to establish the proton EDM experiment plan, after the P5 endorsement in 2014. Large ring radius is favored: Low E-field strength, Long SCT, 1nT B-field tolerance in ring. Use of existing ring preferred.

Future, state of the art IBS building at KAIST: scheduled for ~2018 A bird’s eye view for the IBS building in KAIST campus. The four connected buildings may enclose up to 10 IBS centers. The red polygon shows a suggested area for IBS physics building which may change shape and size in the future.

Temporary CAPP experimental area. Target ~2015

Cryo Development plan

Axion exp. development plan 2014 2015 2016 2017 2018 Magnet Prototype, testing of cable characteristics. 25T, 10cm inner bore design 25T, 10cm inner bore construction Magnet delivery; design of 35T Lab space Temporary building. Design of new build. Constr. Of new building Delivery of new building Axion dark matter Proc. Equipment Study res. geom. Testing high Q dielectric; Development of high Q resonators Production of high-Q resonators Electronics, amplifiers Establ. Collabor. w/ KRISS Design for 1-10GHz Obtain JPAs, test. Develop higher freq. ampl. Ampl. deliveries from KRISS Axion cavity Exp. Design of exp., procure a low field magnet Experimental setup. First test run. Swap magnets

Visitors Send us an email when you want to visit Write down what you want to work on Develop your ideas Come and do your experiment (you as PI) (Leading to eventual publishable results) Incentives for teaching Nuclear/Particle Physics/Cosmology at KAIST (need at least six months warning to setup course).

Summary Axion dark matter experiments are closing in. CAPP can have a significant role in probing the axion mass range 1-100 μeV. Proton EDM: Probe EW-Baryogenesis, high-mass scale New Physics up to ~103 TeV. Two of the most important physics questions today: 1) What is the Dark Matter? 2) Probe the matter-antimatter asymmetry (Baryogenesis) and Physics Beyond the Standard Model.

IBS-MultiDark Joined Focus Program Daejeon, South Korea, October 10-21, 2014 http://www.multidark.es/

Extra slides

ADMX goals and CAPP plan Current plan, low T B-field High-Q B-field

Statistics limited Sensitivity to Rule on Several New Models Baryogenises Electroweak GUT SUSY Gray: Neutron Red: Electron If found it could explain Baryogenesis (p, d, n (or 3He)) n current e current n target p, d target e target Upgrade? Statistics limited Electron EDM New Physics reach: 1-3 TeV, Gabrielse et al., 2013 Much higher physics reach than LHC; complementary e-cm J.M.Pendlebury and E.A. Hinds, NIMA 440 (2000) 471

CAPP-Physics Establish Experimental Particle Physics group. Physics involvement driven by the interest of CAPP individual scientists. Involved in important physics questions: Strong CP problem Cosmic Frontier (Dark Matter axions) Particle Physics (most sensitive proton EDM experiment, flavor conserving CP-violation) Muon g-2; muon to electron conversion (flavor physics)

CAPP Physics plan Setup lab for axion dark-matter search at KAIST based on High Field magnets: 25T, 35T,… R&D towards utilizing high-Q super-conducting cavities with large volumes, high magnetic fields Coordinate with ADMX to avoid duplication. Aim to start taking data within 5-6 years. Play a leadership role in the Storage Ring Proton EDM experiment at Fermilab and significant roles in the muon g-2/EDM experiments, …

New record field, 16 T, for solenoid wound with YBCO High Field Superconductor High Temperature Superconductor at 4 K (not 77 K) Previous record: 10 T YBCO tape: 0.1 mm x 4-12 mm OHEP SBIR with Particle Beam Lasers, BNL as subcontractor (2 Phase IIs, 1 Phase I) – YBCO vendor: SuperPower Full program: 3 nested coils, can test full set to ~ 40 T I = 285 A id = 25 mm, od 91 mm 700 m tape Did not quench R&D program at BNL, from P. Wanderer

SQUID amplifiers