Chem. 133 – 4/1 Lecture. Announcements I Lab –Returning Term Project Proposals (I expect to be getting boxes of supplies ready) –Returning Set 2 Period.

Slides:



Advertisements
Similar presentations
Atomic Absorption Spectroscopy (AAS)I
Advertisements

The Wave Nature of Light
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Chem. 133 – 4/13 Lecture. Announcements I Exam 2 Results: Ave = 55% (10% below last year’s) Lab: Should finish Set 2 Period 4 lab today Thursday is make-up.
Wavelength Selection Devices
Chem. 133 – 3/19 Lecture. Announcements I Lab –Term Project Proposal due today –Lab Report Set 1 Period 2 due today –Next Lab Report due 4/7 Following.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Chem. 133 – 4/7 Lecture. Announcements I Lab –Should be starting Set 2 Period 1 –Set 2 Period 2 Lab Reports due Today Pass Out TH Cheng Award Letters.
Molecular Fluorescence Spectroscopy
1 Molecular Luminescence Spectroscopy Lecture 31.
427 PHC. Introduction  Spectrometric methods are a large group of analytical methods that are based on atomic and molecular spectroscopy.  Spectroscopy.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Chem. 133 – 5/7 Lecture. Announcements I Exam 3 on Tuesday (will give summary of material to know later) Format will be similar to other exams I will.
Chem. 133 – 3/17 Lecture. Announcements Pass back HW + Quiz Lab –Term Project Proposal due Thursday –Next Lab Report also due Thursday Today’s Lecture.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Atomic Absorption Spectroscopy (AAS)
Absorption and emission processes
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
Fourier Transform IR Spectroscopy Saptarshi Basu.
Lecture 3 INFRARED SPECTROMETRY
Atomic Absorption Terry A. Ring Chemical Engineering University of Utah.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Chem. 133 – 3/12 Lecture. Announcements I HW 2.1 problem due today Quiz 3 also today Lab – Term Project Proposal due next Thursday Sign Up (see details.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
Chapter 10 Atomic Emission Spectrometry
 How does the wavelength of a light beam and the size of a slit it is going through control the amount of diffraction? DO WORK STOP.
Introduction to Spectrochemical Methods
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
Optical Characterization methods Rayleigh scattering Raman scattering transmission photoluminescence excitation photons At a glance  Transmission: “untouched”
10/11/ ENGINEERING RESEARCH CENTER FOR S TRUCTURED O RGANIC P ARTICULATE S YSTEMS RUTGERS UNIVERSITY PURDUE UNIVERSITY NEW JERSEY INSTITUTE OF TECHNOLOGY.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Chem. 31 – 4/1 Lecture.
Simple Double Beam Spectrometer
 a mathematical procedure developed by a French mathematician by the name of Fourier  converts complex waveforms into a combination of sine waves, which.
Chem. 31 – 3/30 Lecture. Announcements I Additional Problem due Wed (along with quiz) No Lab Tomorrow (Campus closed for Cesar Chavez holliday) Exam 2.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Spectrophotometry.
Introduction to Spectrochemical Methods
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Atomic-absorption spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
Spectroscopic Analysis Part 3 – Spectroscopy Experiments Chulalongkorn University, Bangkok, Thailand January 2012 Dr Ron Beckett Water Studies Centre School.
1.1 What’s electromagnetic radiation
Chapter 10 Atomic Emission Spectrometry
Chem. 133 – 2/11 Lecture. Announcements Lab today –Will cover 4 (of 8) set 2 labs (remainder covered on Tuesday) –Period 1 will extend one day Website/Homework.
Fourier Transform IR Spectroscopy. Absorption peaks in an infrared absorption spectrum arise from molecular vibrations Absorbed energy causes molecular.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
Chem. 133 – 4/12 Lecture. Announcements I Strike – No Strike now planned Exam 2: – Average was 77 (range 61 to 93) Last HW Set (Set 3 – see handout) Lab.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Chem. 133 – 3/29 Lecture. Announcements I Grading – Set 2 lab reports (return?) – Term project proposals (still working on) – UV-Visible seemed to work.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Chem. 133 – 3/16 Lecture.
Chem. 133 – 4/6 Lecture.
Chem. 133 – 4/4 Lecture.
Flame Emission Spectrometry
Chem. 133 – 3/14 Lecture.
Chem. 133 – 3/30 Lecture.
Optical Characterization Techniques
Chem. 133 – 4/20 Lecture.
Chem. 31 – 10/25 Lecture.
Really Basic Optics Instrument Sample Sample Prep Instrument Out put
Practical Absorbance and Fluorescence Spectroscopy
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Chem. 133 – 4/1 Lecture

Announcements I Lab –Returning Term Project Proposals (I expect to be getting boxes of supplies ready) –Returning Set 2 Period 1 Lab Reports (for those where all partners turned in reports – not GC-MS or HPLC) –Better than electronics lab reports but still some need for improvements: give unknown # in report (I don’t know it) give information on how you performed optimization remember to account for dilutions/other sample processing read instructions for additional questions –Next Lab Report due 4/7

Announcements II Today –Homework due and Quiz Exam 2: Next Thursday Today’s Lecture –Chapter 18: Spectrometer Instrumentation – Wavelength Discrimination Monochromators/Polychromators (finished last time?? – if so skip to slide 7) Other methods of wavelength discrimination –Chapter 20: Atomic Spectroscopy Overview (including other methods of elemental analysis) Theory

Spectrometers Some Questions II 1.If white light enters the monochromator to the right, which wavelength is longer wavelength? 2.List two parameters that will affect the resolution. Can any of these be easily changed? 3.A band pass filter is often placed between the grating and the focusing optics. What is the purpose of this filter? 4.If a grating is used with 320 lines/mm and the output angle for 380 nm is 45 º and the focal length is 40 cm for 1 st order light, what exit slit width is needed to be able to obtain a resolution of 200? 1 2 exit slit

Spectrometers – Wavelength Discrimination C.Polychromators 1.In place of exit slit, an array of detectors exists 2.This allows simultaneous recording of absorption over wavelength range 3.No rotation of grating is needed 4.Resolution (mainly) determined by width of detector element  y = k  light 1 2 sample Detector array top view Detector element yy

Spectrometers – Wavelength Discrimination C.2-D Polychromators 1.Light can be dispersed in two dimensions by placing a prism in front of the grating (dispersion in and out of the screen) to go along with the grating’s dispersion (in y-axis) 2.See Color Plate 25 in Harris 3.Requires 2-D detector array 4.Usually uses high order grating dispersion (e.g. n = 11, 12, 13, 14) with different orders separated by prism 1 2 prism 2-D detector array prism dispersion grating dispersion (y-axis) emission light source Detector elements

Spectrometers – Wavelength Discrimination D.Other Methods 1.Energy-dispersive detectors (X-ray and  -ray analysis) – wavelength discrimination is part of detection system 2.Fourier-transform Instruments -Will cover for IR and NMR -“White” light passed through sample -Variance in response with time or with distance is recorded and then transformed to conventional spectrum

Wavelength Discrimination Fourier Transform Instruments FTIR Instruments –Uses Michelson interferometer (see Figure) –Light goes to beam splitter (partially reflecting/partially transmitting –Part of beam goes to fixed mirror and is reflected. Part of this beam then goes through the sample to the detector –Another part of the original beam goes through the beam splitter to a moving mirror and is reflected with part of this going on to the sample and detector light Beam splitter Fixed mirror Mirror on drive sample detector

Wavelength Discrimination Fourier Transform Instruments FTIR Instruments (continued) –If beams from the two paths combine “ in phase ” (both wave maxima) constructive interference occurs and greater light intensity reaches sample/detector –If beams are not “ in phase ”, less light reaches detector –Distance between beam splitter and mirror affects whether light is in phase –Since “ white ” light is used (actually broad band IR), at different distances, different wavelengths will be in phase intensity Mirror position (or time if mirror moves) 1 2

Wavelength Discrimination Fourier Transform Instruments Performance: –Δṽ is inversely related to distance traveled by mirror (  ) (not explained clearly in text) –This means better resolution (larger ṽ/Δṽ) when  is larger –Spectral range depends on sampled data speed (assuming fast detector) –High resolution over a long wavenumber range will take more time small displacement → poor resolution

Wavelength Discrimination Fourier Transform Instruments Advantages of FT Instruments –Faster than scanning –Greater light throughput –Higher wavenumber accuracy (IR), so can repeat “ scans ” and average signals Disadvantages of FT Instruments –Practical limitations in aligning mirrors –This is more problematic at smaller wavelengths (or larger wavenumbers) where misalignment is a greater % of value extra distance

Light Detectors Detectors covered in electronics section –UV/Vis/NearIR: Photocell, photomultiplier tube, photodiode, photoconductivity cell, and solid state array detectors (charged coupled device or CCD) –IR: temperature measurement (e.g. thermopile), and solid state –NMR: antenna

Light Detectors Detectors for high energy (X-ray,  -ray light) (both gas cells and solid state available) –Due to high energy, a single photon can easily produce a big signal –Two types: gas cells (e.g. Geiger Counter) and solid state sensors (e.g. Si(Li) detectors) –In both cases, detectors can be set up where cascade of electrons is produced from a single photon –The number of ions produced from photons can be dependent upon the photon energy time current high E photon low E photon energy counts/s solid state detector I These detectors are said to be energy dispersive (no monochromator needed)

Atomic Spectroscopy Overview Main Purpose –Determine elemental composition (or concentration of specific elements) Main Performance Concerns –Sensitivity –Multi-element vs. single element –Speed –Interferences (for different matrices) –Precision –Required sample preparation

Atomic Spectroscopy Overview Instrument Types –Analysis for liquid samples (main focus of text + lecture discussion) –Systems for solid samples Modified instruments for liquids –2 examples in book: graphite furnace with solid sample placed in tube (see p. 485) and laser ablation (see p. 495) –laser ablation allows microanalysis X-ray Fluorescence Spectroscopy and X-ray Emission Detection attachments coupled to electron microscopy –Both based on spectral (or energy-dispersive) analysis of emitted X-rays to determine elements present

Atomic Spectroscopy Overview Instrument Types – Systems for Solids – cont. –XRF – cont. –Emitted X-rays have wavelengths dependent upon element (but generally not element’s charge or surroundings) –Accurate quantification is more difficult due to limited penetration of sample by X-rays or electrons and by attenuation of emitted X-rays due to absorption (matrix effects) Instrument Types – For Analysis of Liquids –Atomization Systems: to convert elements to gaseous atoms or ions (MS detection) Flame Electrothermal (Graphite Furnace) Inductively Coupled Plasma (ICP)

Atomic Spectroscopy Overview Instrument Types – For Analysis of Liquids –Atom Detection: to detect atoms (or ions in MS) Atomic Absorption Spectroscopy (with flame or electrothermal) Atomic Emission Spectroscopy (with flame or ICP) Mass Spectrometry (with ICP)

Atomic Spectroscopy Theory Spectroscopy is performed on atoms in gas phase Transitions are very simple (well defined energy states with no vibration/rotation /solvent interactions) Allowed transitions depend on selection rules (not covered here) E Na(g) o (3s) 4s 4p 5s 5p absorption

Atomic Spectroscopy Theory Consequence of well defined energy levels: –very narrow absorption peaks –few interferences from other atoms –very good sensitivity (all absorption occurs at narrow range) –but can not use standard monochromator where  (from monochromator) >>  due to extreme deviations to Beer ’ s law –requires greater wavelength discrimination for absorption measurements A Spectrum from high resolutions spectrometer (not typical for AA) atomic transition molecular transition very narrow natural peak width (  ~ nm) broader width

Atomic Spectroscopy Theory For emission measurements, a key is to populate higher energy levels In most cases, this occurs through the thermal methods also responsible for atomization Fraction of excited energy levels populated is given by Boltzmann Distribution More emission at higher temperatures and for longer wavelengths (smaller  E) Na(g) o (3s) 4p E N = number atoms in ground (0) and excited (*) states g = degeneracy (# equivalent states) = 3 in above example k = Boltzmann constant

Atomic Spectroscopy Theory Example problem: Calcium absorbs light at 422 nm. Calculate the ratio of Ca atoms in the excited state to the ground state at 3200 K (temperature in N 2 O fueled flame). g*/g 0 = 3 (3 5p orbitals to 1 4s orbital).