© ABB - 1 - 2015-06-09 ABB ODINsingle Commercial and technical presentation.

Slides:



Advertisements
Similar presentations
SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead.
Advertisements


BGAN M2M SERVICE + HUGHES 9502 BGAN TERMINAL First BGAN Terminal for Fixed Site Deployment Eric Talman – Technical Manager Whenever Communications, LLC.
PYRO-X De-Ice control devices Technical presentation 2013.
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
© ABB ABB DELTAsingle Commercial and technical presentation.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
© ABB ABB Electricity Meters - intro Per Fridh.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Rail Switch RS2-4R  Fast Ethernet Switch For easy installation of medium to large sized networks For installation of high availability networks using.
Common Equipment 2 : DC power Supply Common Equipment 2 : DC power Supply ---MODEL LPS-305 Motech.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
1 © Red Lion Controls Inc. Introducing the RAM 9000.
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
PPS 3.3 C Portable Power Source Page 1 January 2011.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
Page 1 March 2007 CheckSource 2.3 Portable Power Phantom Load.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
> Micropack System Concept January – Slide 2 Building blocks – Single position power core >Stand alone unit AC Input, L, N, PE, 1,5mm 2 DC Output,
COMPARISON OF VARIOUS TYPES TypeFunctions CMC Sp Pulse + time + velocity PVD100 Hydromate CMC3 Pulse + time + velocity + discharge.
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
Hardware Training Product: ITMS2.
1 SPECIFICATION Power : DC 24V ± 5% Input Signal : RS – 485 SERIAL Display: 4 DIGIT LED (H:10.16mm) Address Selection : POWER TO INPUT Isolation: POWER.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
Digital Message Announcer DMA-1. Solid State Digital Audio Player Applications: security warning messages security warning messages voice alarms voice.
Wiring standards Single phase, 2-wire 120V or 220V Single phase, 3-wire 220V between phases ; 110V between phase-neutral.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
1000 Series Ultra-Portable Multi Function Calibrator Portability, without compromise.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
RXM*LB Product presentation
1 Comparison of 100-B and 100-D Contactors B Contactors.
Tod Mackay Channel Sales - RSC Battery Storage Options Tesla Powerwall Single-Phase – SolarEdge StorEdge Three-Phase – Fronius Symo Hybrid SMA Sunny.
INSTApower Compact Power Supplies. INSTA POWER INSTA POWER – Primary switch-mode power supplies The trend in the range of power supplies goes more and.
ABB i-bus® KNX Fan Coil Actuator FCA/S
Fan Coil Actuator FCA/S 1.x.x.2
Industrial 1-Port Ultra PoE Splitter
VARLOGIC NRC12 Varmetric Controller
RXG Product Presentation
Sensor presentation.
ENERGY METERS DME SERIES
ECE 445 Smart Window Responding System
System Network Structure
New EM210_AV.
ABB i-bus® KNX Valve Drive Actuator VAA/A
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
HD SIGNAL CONDITIONER SERIES
ABB Stotz-Kontakt GmbH ZS/S 1.1 Meter Interface Module
IDM-3 3-PHASE AMMETER.
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Universal Interface, 12-fold, FM US/U 12.2
Universal Dim Actuator UD/S
HD SIGNAL CONDITIONER SERIES
Energy Meters ME.
Detailed information FOR INTERNAL USE ONLY! CUBE20.
Presentation transcript:

© ABB ABB ODINsingle Commercial and technical presentation

© ABB Presentation Content ABB’s DIN rail meters offering Overview - product functions Product range Product features / technical data Typical applications

© ABB ABB DIN Rail Meters ABB Single phase metersThree phase meters  65 A direct metering  80 A direct metering  65 A direct metering or Transformer connected (5/5 – 900/5 A/A)  80 A direct metering or Transformer connected (1 – 9 999) ODINsingleDELTAsingleODINDELTAplus

© ABB Overview – Product functions

© ABB Product range - ODINsingle Only two types! OD 1065 Basic version OD 1365 Pulse output Reset function

© ABB ODINsingle - Product overview Neutral (+/- screw) Current input (+/- screw) LCD – 6 digits possible to read in darkness. Current out (+/- screw) Pulse output (OD1365 only) “Reset” button (OD1365 only) LED For verification IR interface on the left side of the meter

© ABB Product features Direct metering up 65A IEC and MID approval IEC , IEC EN , -3 Approved for revenue metering 6 digits backlit LCD display DIN rail mounting Size, only 2 modules wide Load indicator on display Resettable (OD1365 only) Communication alternatives LCD display Pulse output (OD1365 only) IR interface for serial communication Only two models for easy logistics OD1065 without pulse output OD1365 with pulse output, resettable

© ABB Technical data Voltage1 x 230 V Accuracy class B (+/-1 %) Max current65A Starting current<20mA Frequency50/60Hz Temp. range operation-25 to +55ºC Pulse output100 imp/kWh (5-40V DC) LED output1000 imp/kWh Max terminal area16 mm 2 Power consumption <1.0 VA IEC approvedIEC , MID approvedEN , -3

© ABB Typical applications for ODINsingle Apartments (smaller flats and student apt.) Shopping malls Exhibition halls Marinas & Camping sites

© ABB Apartments

© ABB Student flats

© ABB Shopping malls

© ABB Exhibition halls

© ABB Marinas

© ABB Camping sites

© ABB