October 2005 Geant4 Medical North America J. Perl 1 Geant4 Medical Application Activity in North America Joseph Perl, SLAC.

Slides:



Advertisements
Similar presentations
The GATE-LAB system Sorina Camarasu-Pop, Pierre Gueth, Tristan Glatard, Rafael Silva, David Sarrut VIP Workshop December 2012.
Advertisements

GEANT4 Simulations of TIGRESS
Seeram Chapter 13: Single Slice Spiral - Helical CT
Research Protocol ACRIN 6678 Learning About PET/CT Scans: Can PET/CT scans provide helpful information for the treatment of non-small cell lung cancer?
6 March 2006 G4NAMU Meeting J. Perl 1 SLAC - Redwood Room 6 March Geant4 North American Medical Users Organization.
Building clinical Monte Carlo code from Geant4, PENELOPE or EGSnrc Joao Seco 1, Christina Jarlskog 1, Hongyu Jiang 2 and Harald Paganetti 1 1 Francis H.
Jul Recent Resources for G4NAMU J. Perl Recent Resources for G4NAMU This talk provides pointers to some recent resources of interest to G4NAMU members.
Summary of Medical Physics Parallel Sessions and Discussions Joseph Perl Stanford Linear Accelerator Center Geant4 Workshop Hebden Bridge, UK 19 September.
Jul Geant4 North American Medical Users Organization J. Perl Geant4 North American Medical Users Organization - G4NAMU Bring this community together.
Bruce Faddegon, UCSF Inder Daftari, UCSF Joseph Perl, SLAC
Kirov A S, MSKCC Overview of Geant4 Use and Issues in Imaging: Emission Tomography (PET and SPECT) Assen S. Kirov Department of Medical Physics Memorial.
Emily Poon Frank Verhaegen March 6, 2006
SLAC Geant4 Tutorial 2009 J. Perl
Geant4 in Brachytherapy
(Geant4) Monte Carlo benchmarking
6 March 2006 G4NAMU Organizational Issues J. Perl 1 SLAC - Redwood Room 6 March Geant4 North American Medical.
G4NAMU GEANT4 North America Medical Users Organization (G4NAMU) GEANT4 in external beam therapy Harald Paganetti.
Jul Geant4 North American Medical Users Organization J. Perl Geant4 North American Medical Users Organization - G4NAMU Bring this community together.
6 March 2006 G4NAMU Geant4 Developments J. Perl 1 SLAC - Redwood Room 6 March Geant4 North American Medical.
Dr. Paul Gueye Hampton University G4NAMU - SLAC Overview Of Geant4 Medical Activities At Hampton UniversityJefferson Lab Hampton University - Hampton,
PHYSICS IN NUCLEAR MEDICINE: QUANTITAITVE SPECT AND CLINICAL APPLICATIONS Kathy Willowson Department of Nuclear Medicine, Royal North Shore Hospital University.
24 July 2005 G4NAMU AAPM 2005 J. Perl 1 G4NAMU at AAPM Seattle 2005 Joseph Perl, SLAC.
1 M.G. Pia et al. The application of GEANT4 simulation code for brachytherapy treatment Maria Grazia Pia INFN Genova, Italy and CERN/IT
The brachytherapy advanced example Susanna Guatelli (CERN/INFN)
Budker Inst. of Physics IHEP Protvino MEPHI Moscow Pittsburg University.
American Association of Physicists in Medicine (AAPM) Task Group on Monte Carlo Validation Sets: Geant4 Related Findings Ioannis Sechopoulos, Ph.D. Assistant.
Laser Accelerated Proton Beams for Radiation Therapy C-M Ma, T Tajima, B Shahine, JS Li, MC Lee, T Guerrero and AL Boyer Dept. of Radiation Oncology Stanford.
Derek Liu E. Poon, M. Bazalova, B. Reniers, M. Evans
Annual SERC Research Review - Student Presentation, October 5-6, Extending Model Based System Engineering to Utilize 3D Virtual Environments Peter.
به نام خداوند بخشایندۀ بخشایشگر
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Geant4 Collaboration workshop Layered Mass Geometry Improvements for Brachytherapy Applications Shirin A. Enger, Michel D'Amours Université Laval Centre.
1 GEANT4: Applications in Medical Physics B. Caccia Department of Technology and Health Istituto Superiore di Sanità (Italian National Institute of Health)
M.G. Pia et al. Brachytherapy at IST Results from an atypical Comparison Project Stefano Agostinelli 1,2, Franca Foppiano 1, Stefania Garelli 1, Matteo.
G. Bartesaghi, 11° ICATPP, Como, 5-9 October 2009 MONTE CARLO SIMULATIONS ON NEUTRON TRANSPORT AND ABSORBED DOSE IN TISSUE-EQUIVALENT PHANTOMS EXPOSED.
Usability Issues Documentation J. Apostolakis for Geant4 16 January 2009.
Joseph Perl SLAC National Accelerator Laboratory Scientific Computing Workshop 20 June 2011 Work supported in part by the U.S. Department of Energy under.
Ian C. Smith 1 A portal-based system for quality assurance of radiotherapy treatment plans using Grid-enabled High Performance Computing clusters CR Baker.
American Nuclear Society Mathematics and Computation Division (MCD) Presentation to the ANS Board of Directors Todd S. Palmer November 18, 2009, Washington,
Ye, Sung-Joon, Ph.D. Ove, Roger, M.D., Ph.D.; Shen, Sui, Ph.D.
A General Purpose Brachytherapy Software Simulation + Analysis (isodose calculation) 2/10/2002 Geant4 Workshop CERN Susanna Guatelli Univ. and INFN Genova.
Technological Transfer from HEP to Medical Physics How precise Brachytherapy MonteCarlo simulations can be applied in Clinics Reality Problem: How to achieve.
Historical Review and Modalities in Diagnostics
Principles and Practice of Radiation Therapy
TPS & Simulations within PARTNER D. Bertrand, D. Prieels Valencia, SPAIN 19 JUNE 2009.
Improvement of the Monte Carlo Simulation Efficiency of a Proton Therapy Treatment Head Based on Proton Tracking Analysis and Geometry Simplifications.
User support and requirements capturing processes Geant4 Collaboration organization, management and communication review November 9 th, 2012 Marc Verderi.
8/Mar./041st Workshopon the Italy-Japan Collaboration on Geant4 Medical Application 1 Use-Case on treatment planning at HIMAC Koichi Murakami KEK 1 st.
N 0 primary photons generated N d primary photons detected Determination of the photon mass attenuation coefficients Check on ParentID( ) Energy value.
Comparison of MC and TP Dosimetry Simulations for Cancer Treatment Raymond Mumme May 12, 2014 Supervisor: Thiago Lima (PhD student) Head Supervisor: Dr.
P. Rodrigues, A. Trindade, L.Peralta, J. Varela GEANT4 Medical Applications at LIP GEANT4 Workshop, September – 4 October LIP – Lisbon.
Geant4 Training 2004 Short Course Katsuya Amako (KEK) Gabriele Cosmo (CERN) Giuseppe Daquino (CERN) Susanna Guatelli (INFN Genova) Aatos Heikkinen (Helsinki.
Maria Grazia Pia, INFN Genova and CERN1 Geant4 highlights of relevance for medical physics applications Maria Grazia Pia INFN Genova and CERN.
Representing Range Compensators with Computational Geometry in TOPAS Forrest Iandola 1,2 and Joseph Perl 1 1 SLAC National Accelerator Laboratory 2 University.
Implementation of a New Monte Carlo Simulation Tool for the Development of a Proton Therapy Beam Line and Verification of the related Dose Distributions.
INFSO-RI Enabling Grids for E-sciencE Grid based telemedicine application for GATE Monte Carlo dosimetric studies using HOPE (Hospital Platform.
Flair development for the MC TPS Wioletta Kozłowska CERN / Medical University of Vienna.
Dae-Hyun Kim Dept. of Biomedical Engineering The Catholic University of Korea Department of Biomedical Engineering Research Institute.
Presentation of Master of medical and imagery physics Rajaa Cherkaoui El Moursli, Mohammed V – Agdal University, Rabat, Morocco Hassan II Academy of Sciences.
GATE application example using SuperComputer 국립암센터 박 세 준 연구원.
MCS overview in radiation therapy
Geant4 low energy validation Jean-Francois Carrier, Louis Archambault, Rene Roy and Luc Beaulieu Service de radio-oncologie, Hotel-Dieu de Quebec, Quebec,
Computed Tomography Basics
Quantitative Nuclear Medicine Imaging
Very High Energy Electron for Radiotherapy Studies
A Brachytherapy Treatment Planning Software Based on Monte Carlo Simulations and Artificial Neural Network Algorithm Amir Moghadam.
Monte Carlo Simulation
Basic principles Geometry and historical development
Geant4 at IST Applications in Brachytherapy
P. Rodrigues, A. Trindade, L.Peralta, J. Varela
Presentation transcript:

October 2005 Geant4 Medical North America J. Perl 1 Geant4 Medical Application Activity in North America Joseph Perl, SLAC

October 2005 Geant4 Medical North America J. Perl 2 What is G4NAMU? G4NAMU – the Geant4 North America Medical Users Organization Launched in May of 2005 to provide a meeting place for the rapidly growing Geant4 medical user community of North America. The purpose of G4NAMU is to bring this community together to share issues and advice, to develop regional collaboration and to communicate as a group to the Geant4 developers.

October 2005 Geant4 Medical North America J. Perl 3 Who is G4NAMU? G4NAMU's current membership includes 52 members from 27 institutions throughout Canada and the United States. Current subscribers to the mailing list (page 1 of 3): SLAC: Joseph Perl, Makoto Asai SLAC: Joseph Perl, Makoto Asai Harvard & Mass General: Harald Paganetti, Xing-Qi Lu, Roelf L. Slopsema Harvard & Mass General: Harald Paganetti, Xing-Qi Lu, Roelf L. Slopsema UCSF: Bruce Faddegon, Inder Daftari UCSF: Bruce Faddegon, Inder Daftari ULaval: Jean-François Carrier, Luc Beaulieu, Louis Archambault, Vincent Hubert Tremblay ULaval: Jean-François Carrier, Luc Beaulieu, Louis Archambault, Vincent Hubert Tremblay CHUQ: Luc Gingras CHUQ: Luc Gingras UPenn: Steven Avery, Dickson Goulart, Jim McDonough UPenn: Steven Avery, Dickson Goulart, Jim McDonough Stanford: Todd Pawlicki, Gary Luxton, Lei Xing Stanford: Todd Pawlicki, Gary Luxton, Lei Xing Louisiana State University: Blair Smith Louisiana State University: Blair Smith Fox Chase: Charlie Ma, Jiajin Fan, Jinsheng Li Fox Chase: Charlie Ma, Jiajin Fan, Jinsheng Li (continued on next slide…) (continued on next slide…)

October 2005 Geant4 Medical North America J. Perl 4 Who is G4NAMU? (continued) Current subscribers to the mailing list (continued): McGill: Emily Poon, Frank Verhaegen, Jan Seuntjens McGill: Emily Poon, Frank Verhaegen, Jan Seuntjens Triumf: Peter Gumplinger, Frederick Jones Triumf: Peter Gumplinger, Frederick Jones Memorial Sloan-Kettering: C. Ross Schmidtlein, Assen Kirov, Sadek Nehmeh, Christopher Danford Memorial Sloan-Kettering: C. Ross Schmidtlein, Assen Kirov, Sadek Nehmeh, Christopher Danford Johns Hopkins: Jingyan Xu Johns Hopkins: Jingyan Xu University of Arkansas: Hongyu Jiang University of Arkansas: Hongyu Jiang Jefferson Lab: Paul Gueye, Stan Majewski, Mark Smith, David Hamlette, Michael Epps, Marion MacCormic Jefferson Lab: Paul Gueye, Stan Majewski, Mark Smith, David Hamlette, Michael Epps, Marion MacCormic Advanced Laser Light Source: Jean-Claude Kieffer, Jean-Philippe Moreau Advanced Laser Light Source: Jean-Claude Kieffer, Jean-Philippe Moreau University of Wisconsin – Madison: Hazim A Jaradat University of Wisconsin – Madison: Hazim A Jaradat INRS: Francois Vidal, Sylvain Fourmaux, Ludovic Lecherbourg, Rémy Toth INRS: Francois Vidal, Sylvain Fourmaux, Ludovic Lecherbourg, Rémy Toth Université de Sherbrooke: Daniel Houde Université de Sherbrooke: Daniel Houde (continued on next slide…) (continued on next slide…)

October 2005 Geant4 Medical North America J. Perl 5 Who is G4NAMU? (continued) Current subscribers to the mailing list (continued): University of Alberta: Robert Fedosejev, Craig Unick University of Alberta: Robert Fedosejev, Craig Unick Walter Reed Army Medical Center: Dan Fry Walter Reed Army Medical Center: Dan Fry Texas A&M: Yong Chen Texas A&M: Yong Chen University of Washington: Ruth Schmitz University of Washington: Ruth Schmitz Hopital Maisonneuve-Rosemont: Brigitte Reniers Hopital Maisonneuve-Rosemont: Brigitte Reniers University of Minnesota: Lihong Qin University of Minnesota: Lihong Qin Xoft Inc.: Steve Axelrod Xoft Inc.: Steve Axelrod

October Geant4 Medical North America J. Perl G4NAMU within the World Geant4 Collaboration Of course all Geant4 users are part of a world wide community. Of course all Geant4 users are part of a world wide community. Medical Applications forum and other user forums are available for discussion and exchange, as well as other Geant4 workshops and meetings. Medical Applications forum and other user forums are available for discussion and exchange, as well as other Geant4 workshops and meetings. But regional efforts also have a role. But regional efforts also have a role. In Europe, some efforts are being organized through Maria Grazia Pia of INFN, and through others In Europe, some efforts are being organized through Maria Grazia Pia of INFN, and through others In Japan, some efforts are being organized through Takashi Sasaki of KEK (including carbon beams, parallel computing) In Japan, some efforts are being organized through Takashi Sasaki of KEK (including carbon beams, parallel computing) In North America, there has been no similar effort at regional organization In North America, there has been no similar effort at regional organization

October Geant4 Medical North America J. Perl G4NAMU as Regional Voice G4NAMU can serve as voice of the North American Geant4 Medical User community G4NAMU can serve as voice of the North American Geant4 Medical User community Organize regional workshops or tutorials Organize regional workshops or tutorials Foster nearby collaborations Foster nearby collaborations Speak with a collective voice to regional funding agencies Speak with a collective voice to regional funding agencies Meet regional certification needs Meet regional certification needs At its meeting last month in San Diego, the American Nuclear Society (ANS) recognized the formation of a Computational Medical Physics Working Group (CMPWG). CMPWG will be hosted by three divisions of ANS - Mathematics and Computations (M&C), Biology and Medicine (BMD), Radiation Protection and Shielding (RPSD). At its meeting last month in San Diego, the American Nuclear Society (ANS) recognized the formation of a Computational Medical Physics Working Group (CMPWG). CMPWG will be hosted by three divisions of ANS - Mathematics and Computations (M&C), Biology and Medicine (BMD), Radiation Protection and Shielding (RPSD). CMPWG may become involved in benchmarking codes for Medical Physics applications. CMPWG may become involved in benchmarking codes for Medical Physics applications.

October Geant4 Medical North America J. Perl How Should G4NAMU Work? We've agreed to use a mailing list. We've agreed to use a mailing list. The list is lightly moderated just to maintain focus and prevent spam. The list is lightly moderated just to maintain focus and prevent spam. To join the list, send mail to To join the list, send mail to We will have periodic meetings and will try, as we have today, to take advantage of existing meetings. We will have periodic meetings and will try, as we have today, to take advantage of existing meetings. We can go beyond this: We can go beyond this: Provide workshops or tutorials Provide workshops or tutorials Develop additional Geant4 examples Develop additional Geant4 examples Certify certain parts of the code for use in our communities Certify certain parts of the code for use in our communities Collect requirements for Geant4 developers Collect requirements for Geant4 developers

October Geant4 Medical North America J. Perl Where Does SLAC Fit into G4NAMU Three of us are from the SLAC Geant4 group (Asai, Wright, Perl) Three of us are from the SLAC Geant4 group (Asai, Wright, Perl) Largest center of Geant4 development outside of CERN Largest center of Geant4 development outside of CERN Expertise in essentially all areas of Geant4 Expertise in essentially all areas of Geant4 Three seats on the Geant4 technical steering board Three seats on the Geant4 technical steering board Our laboratory and university strongly support our involvement with the medical physics community Our laboratory and university strongly support our involvement with the medical physics community From SLAC, we’ve set up the mailing list, and we’ve started an initial G4NAMU web site: From SLAC, we’ve set up the mailing list, and we’ve started an initial G4NAMU web site: Extremely boring page at present. Content welcome! Extremely boring page at present. Content welcome! I would be happy to serve as maintainer of a formal G4NAMU requirements list that would give input to the Geant4 developers I would be happy to serve as maintainer of a formal G4NAMU requirements list that would give input to the Geant4 developers While the SLAC group are happy to contribute in this way, we understand that we are just one member of this new community. G4NAMU must be a consensus organization that evolves as needed by its members. While the SLAC group are happy to contribute in this way, we understand that we are just one member of this new community. G4NAMU must be a consensus organization that evolves as needed by its members.

October Geant4 Medical North America J. Perl Some Next Steps Improve communication between Geant4 developers and the medical physics community. Improve communication between Geant4 developers and the medical physics community. Collect requirements for Geant4 developers. Collect requirements for Geant4 developers. Validation: Validation: Clarify what studies have been done, what results have been found, what studies still need to be done. Clarify what studies have been done, what results have been found, what studies still need to be done. Perform additional beam tests as needed. Perform additional beam tests as needed. Compare cross sections used by Geant4 with those used by other MC codes in Medicine. Compare cross sections used by Geant4 with those used by other MC codes in Medicine. Calculation speed: Calculation speed: Understand issues. Understand issues. Suggest and validate variance reduction methods. Suggest and validate variance reduction methods. Create additional medical examples. Create additional medical examples. Continue discussion on the mailing list. Invite additional colleagues to the list. Continue discussion on the mailing list. Invite additional colleagues to the list. Maintain Relationships with Relevant North American Professional Organizations: Maintain Relationships with Relevant North American Professional Organizations: ANS Computational Medical Physics Working Group (CMPWG). They have asked Harald Paganetti to represent Geant4. ANS Computational Medical Physics Working Group (CMPWG). They have asked Harald Paganetti to represent Geant4. AAPM Task Group No. 105: "Guidance report on clinical implementation of the Monte Carlo method in external beam radiation therapy treatment planning.” AAPM Task Group No. 105: "Guidance report on clinical implementation of the Monte Carlo method in external beam radiation therapy treatment planning.” Work on ways to improve funding for Geant4 medical work in North America. Work on ways to improve funding for Geant4 medical work in North America.

October Geant4 Medical North America J. Perl Some Next Steps Develop the G4NAMU web site: Develop the G4NAMU web site: Should answer question: Why would I use Geant4 for medical physics? Should answer question: Why would I use Geant4 for medical physics? Clarify which physics lists are recommended for which medical problems. Clarify which physics lists are recommended for which medical problems. Provide a medical physicist's overview of each Geant4 release's release notes. I.e., what should a medical physicist know about this new release. Provide a medical physicist's overview of each Geant4 release's release notes. I.e., what should a medical physicist know about this new release. Collect references to papers. Collect references to papers. For those papers that are publicly available, include actual copies of the papers. For those papers that are publicly available, include actual copies of the papers. For those papers that are restricted by subscriber permissions, include abstract and then link to actual publication (which not all viewers will be able to actually read). For those papers that are restricted by subscriber permissions, include abstract and then link to actual publication (which not all viewers will be able to actually read). Show Geant4 results in three sections: Show Geant4 results in three sections: 1. Where is Geant4 known to give good results? Link to appropriate publications. 2. Where is Geant4 known to give poor results? Link to appropriate publications. Include discussion known problems and of what is planned to improve these issues. 3. Where are Geant4 results unknown? I.e., what additional tests do we know we need to perform? Show member names by work area. Show member names by work area. Hold tutorials aimed at medical users. Hold tutorials aimed at medical users. SLAC, early March 2006, details to be announced SLAC, early March 2006, details to be announced Jefferson Lab, later in 2006, details to be announced Jefferson Lab, later in 2006, details to be announced Smaller tutorials annually as part of AAPM annual meeting Smaller tutorials annually as part of AAPM annual meeting

October Geant4 Medical North America J. Perl G4NAMU G4NAMU in External Beam Therapy (Ad-Hoc Working Group Coordinator: Harald Paganetti)

October Geant4 Medical North America J. Perl G4NAMU Beamline design and quality assurance

October Geant4 Medical North America J. Perl G4NAMU Magnetic fields

October Geant4 Medical North America J. Perl G4NAMU Absolute dosimetry Volume for absolute dosimetry

October Geant4 Medical North America J. Perl G4NAMU Patient dose calculation FOCUS Monte Carlo

October Geant4 Medical North America J. Perl G4NAMU Time dependent simulations Solid lines:Patient in inhale Dashed lines:Considering the entire breathing phase

October Geant4 Medical North America J. Perl G4NAMU Radiation Protection

October Geant4 Medical North America J. Perl G4NAMU Radiation Risk © X. George Xu, RPI

October Geant4 Medical North America J. Perl G4NAMU Detector Simulation

October 2005 Geant4 Medical North America J. Perl 21 G4NAMU in Brachytherapy (Ad Hoc Working Group Coordinator: Paul Gueye)

October Geant4 Medical North America J. Perl Modeling of encapsulated 192 Ir source (Courtesy of McGill University) 3.5 mm 5 mm 1.1 mm 2 m 0.6 mm MicroSelectron Classic HDR source (part no )

October Geant4 Medical North America J. Perl Radial dose and anisotropy functions of encapsulated source (Courtesy of McGill University) Radial dose function GEANT4: ~0.4% higher than Williamson and Li (Med. Phys. 22, , 1995) Anisotropy function GEANT4: ±1% agreement with Williamson and Li

October Geant4 Medical North America J. Perl Isodose distributions (Courtesy of McGill University) Presence of lead shielding reduces the dose distribution in a lucite phantom by up to 20%, and it is confirmed by ion chamber measurements.

October Geant4 Medical North America J. Perl Octree geometry compression – DICOM images Indexing of the density distributions using a density gradient threshold: Indexing of the density distributions using a density gradient threshold: High resolution kept only in heterogeneous area High resolution kept only in heterogeneous area Can easily reduce the number of voxels by 75% Can easily reduce the number of voxels by 75% Does not affect dose distribution Does not affect dose distribution Objectives: Reduce the number of voxels Keep the critical information Voxel-based geometry V. Hubert-Tremblay, MSc project

October Geant4 Medical North America J. Perl Octree geometry compression – DICOM images Examples: CT phantom + thorax patient Voxel number v/s DGT

October Geant4 Medical North America J. Perl LDR 125 I source, Amersham 6711 Validation of the model: radial dose fonction Prostate brachytherapy - LDR J.-F. Carrier, Ph.D. project

October Geant4 Medical North America J. Perl This interseed attenuation is not considered in TG43 (clinical) dose calculations MC simulations on clinical treatment plans 1) Interseed attenuation 1.7% Prostate brachytherapy - LDR 3.3% RED PLAN  77 seeds  0.6 mCi activity  1.7% of the D90 value is lost due to interseed attenuation BLUE PLAN  137 seeds  0.3 mCi activity  3.3% of the D90 value is lost due to interseed attenuation

October Geant4 Medical North America J. Perl 2) Medium composition: CT-based MC Prostate brachytherapy - LDR CT image G4 geometry G4 DICOM reader[1] Organ contours Seed positions [1] D90: 5-7% differences between water MC and CT-based MC MC simulations on clinical treatment plans

October Geant4 Medical North America J. Perl Hampton University (Collaboration: NIST, EVMS) Scintillating Fiber based Beta Detector → Absolute calibration of sources Lawrence Tynes, Ph.D.: Detector Nnenna Onumah, Ph.D.: Geant4 z y 1 z 32

October Geant4 Medical North America J. Perl Hampton University (Collaboration: Proxima Therapeutics, dePaul) Active Mammosite → Absolute real-time position measurement (within ±1 mm) → Absolute real-time dose measurement → Modelization of the dose distribution using CT scan data & 4D phantom Jacquelyn Winston, M.Sc.: Detector Rachel Black, Ph.D. : Detector, Geant4 & VTK

October Geant4 Medical North America J. Perl Hampton University (Collaboration: Jefferson Lab, EVMS, ODU) Monoenergetic Brachytherapy Sources → Energy dependence of irradiated breast cancer cells Ariano Munden, M.Sc. Dipole Breast cancer cells Collimator and Sr-90 source

October Geant4 Medical North America J. Perl ALLS Facility Ultrafast Laser & Biomedical Research Advanced Laser Light Source Varennes, Canada Varennes, Canada Dynamics of biological processes Dynamics of biological processes 10 Hz, 300 mJ, 25 fs 100 Hz, 100 mJ, 25 fs

October Geant4 Medical North America J. Perl G4NAMU in Imaging (Ad-Hoc Working Group Coordinator: Assen S. Kirov)

October Geant4 Medical North America J. Perl Membership in the OpenGATE collaboration ( ) Whose goal is - the creation of an elaborate and flexible Monte Carlo program that allows realistic simulation of the physical processes, detector geometry and all factors affecting emission tomography applications - realistic modeling of patient and small animal anatomy - based on GEANT4

October Geant4 Medical North America J. Perl User Layer … /gate/block/daughters/name crystal /gate/block/daughters/insert box /gate/crystal/placement/setTranslation mm /gate/crystal/geometry/setXLength 30.0 mm /gate/crystal/geometry/setYLength 4.4 mm /gate/crystal/geometry/setZLength 4.75 mm /gate/crystal/setMaterial BGO … -Verbosity and visualization -Geometry -Digitizer -Physics -Sources -Outputs -Experiment

October Geant4 Medical North America J. Perl GATE time and movements Needed for: - Patient and organ motion - Scanner rotation - Activity distribution changes GEANT4 limitations: - geometry: static during simulation - no source movements Solutions in GATE: - Geometry updated between simulation time steps - The source is confined to a smaller volume moving inside a larger emission volume Santin et al, 2003 Strul et al, 2003 Jan et al, PMB 49 (2004) 4543

October Geant4 Medical North America J. Perl GATE digitization - Resolution blurring, spatial blurring, crosstalk - Parallelizable and non-parallelizable dead times - Coincidence processing - Post simulation processing of output files stored before digitization

October Geant4 Medical North America J. Perl GATE validation PETat least 5 patient and microPET scanners PETat least 5 patient and microPET scanners energy spectra, sensitivity, resolution, scatter faction, count rates, image quality, contrast recovery energy spectra, sensitivity, resolution, scatter faction, count rates, image quality, contrast recovery SPECT at least 5 systems SPECT at least 5 systems energy spectra, sensitivity, resolution,… energy spectra, sensitivity, resolution,… Prototypeat least 4 systems Prototypeat least 4 systems energy spectra, sensitivity, resolution… More than 15 references in Jan et al, PMB 49 (2004) 4543 and at

October Geant4 Medical North America J. Perl GE Advance/ DLS PET scanner