COMPENSATION By: Ronald Mathieu. Compensation Why do we need compensation? –1) Because of long emission spectrum of dyes like FITC and PE.

Slides:



Advertisements
Similar presentations
Working with Profiles in IX1D v 3 – A Tutorial © 2006 Interpex Limited All rights reserved Version 1.0.
Advertisements

Introduction to Flow Cytometry
Building a Panel Select markers Select conjugates Method to build panel performance criteria.
BD FACSDiVa 4.1 An introduction.
Introduction to Operation of the XL-30 Scanning Electron Microscope Tutorial # 1 Overview of XL-30 Microscope Control Program.
FACSCalibur Training A Look Inside the Box
1 2 3 * Flow = cells in motion * Cyto = cell * Metry = measure * Measuring properties of cells while in a fluid stream * Flow Sorting * Sorting (separating)
What is Flow Cytometry? Flow Cytometry uic Introduction to Flow Cytometry IGC Workshop Multicolor Flow Cytometry IGC – April 28, 2010 Adapted from Holden.
AUTOFLUORESCENCE By: Ronald Mathieu. Autofluorescence Cells contain molecules, which become fluorescent when excited by UV/Visual radiation of suitable.
Quality Control in Immunophenotyping Dr. N. Varma Prof. & Head – Hematology Post Graduate Institute of Medical Education & Research (PGIMER), Chandigarh.
Workshop 15 Hybrid meshing of a simple HVAC assembly
Welcome IQAC at DHVI CD4 Immunophenotyping for HIV Monitoring Flow Cytometry.
Using FlowJo to calculate compensation Emory Vaccine Center FCC / Suzanne Mertens /
Advancements in FACS analyzers optical design leads to greater functionality and a smaller footprint. INTRODUCTION In the past decade, instrumentation.
Page 1 © J.Paul Robinson, Purdue University BMS 602 LECTURE 9.PPT BMS LECTURE 10x Flow Cytometry: Theory Bindley Bioscience Center Purdue.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Introducing a new instrument to the Cancer Center Flow Cytometry Core Facility: The LSR II by Becton Dickinson.
FLOW CYTOMETRY Dr. MOHAMMED H SAIEMA LDAHR KAAU FACULTY OF APPLIED MEDICAL SCIENCES MEDICAL TECHNOLOGY DEPT. 2 ND YEAR MT INSTROMINTATION EXT
Compensation The process of correcting for flourescence crosstalk
Flow Cytometry. Allows For Detection Of Surface Markers Of Cells Allows For Detection Of Intracellular Factors Allows Detection Of Secreted Factors By.
Introduction to the Principles of Flow Cytometry
Workshop Tutorial Polish Cytometry Society 1998 Analysis of flow cytometric data - data collection, principles of gating and histogram analysis This presentation.
FACSCalibur Training General Information The FACSCalibur is a useful analysis tool. The instrument has 2 lasers- 488 (primary) and 633 (secondary) that.
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
These particles have something in common
Introduction to Flow Cytometry
PPT 206 Instrumentation, Measurement and Control SEM 2 (2012/2013) Dr. Hayder Kh. Q. Ali 1.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
Making your own stereo slide show in PowerPoint Making your own stereo slide show in PowerPoint.
Scanning and Image Processing -by Steve Clough. GSI Lumonics cDNA microarrays use two dyes with well separated emission spectra such as Cy3 and Cy5 to.
Cell viability studies Sepideh Khoshnevis. The Goal To distinguish live cells from dead and apoptotic cells in order to calculate the the percentage of.
Color Correct and Remove Keystoning A minimalist approach to photographing your art By Paul Marley.
CAD3D Project. SketchUp - Project Create a new SketchUp project called InitialsXX where the XX are your first and last initial. Use the Rectangle tool.
Flow Cytometry at Boston University Medical Campus Introduction to some methods that we offer Yan Deng (X4-5225), Gerald Denis (X4-1371),
Basic Principles in Flow Cytometry
 Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid.
Calibration & Measurements. Calibrating the System Before we can make any measurements we need to calibrate our imaging system to create real world numbers.
PowerPoint Basics Tutorial 3: Graphics In this tutorial we’ll be looking at graphics, and the various types of illustrations that can be included in a.
Basic Principles, Instrumentation, and Practices
Exp. 18: Spectrophotometric Analysis: Concentration of a Solution Using Beer’s Law White light violet (400nm) – red (800nm) “visible spectrum” sample (light.
PowerPoint Basics Tutorial 3: Graphics In this tutorial we’ll be looking at graphics, and the various types of illustrations that can be included in a.
FLOW CYTOMETRY  Definition: Measuring properties of cell as they flow in a fluid suspension across an illuminated light path.
Laser Flow Cytometry Forward Scatter indicates size Forward Scatter.
Design Studies 20 ‘Show Off’ Project How to make a computer monitor In Google Sketchup By: Liam Jack.
Flow Cytometry Basic Training. What Is Flow Cytometry? Flow ~ cells in motion Cyto ~ cell Metry ~ measure Measuring properties of cells while in a fluid.
Flow Cytometry Becton Dickinson Asia Limited Company.
Making Billboards By Deborah Nelson Duke University, Under the direction of Professor Susan Rodger, July 14, 2008.
Flow Cytometry. Applications FRET- protein interaction Membrane protein expression Intracellular protein expression Cell viability Ca 2+
F LUORESCENCE – A CTIVATED C ELL S ORTING Ana Luisa Caetano Unidade de Citometria de Fluxo Instituto de Medicina Molecular.
How to Make a FACS Diva Template
Absorption Spectrum for Plant Pigments
Cytometry tutorial: The impact of adjusting PMT voltages on spillover and compensation Thomas Myles Ashhurst1,2,3, Adrian Lloyd Smith3,4 1Viral Immunopathology.
FACSCalibur Training General Information
Flow Cytometry Halima Moncrieffe, University College London, UK IL-17
Flowcytometry.
FLOWCYTOMETRY.
Tutorial for using Case It for qPCR analyses
COMPENSATION + FITC - PE - + PE - FITC - FITC detector FITC PE
ImageStream Operator Training A Revolution in Cell Analysis.
Optical measurement.
Volume 99, Issue 8, Pages (October 2010)
Label-Retaining Cells (Presumptive Stem Cells) of Mice Vibrissae Do Not Express Gap Junction Protein Connexin 43  Maja Matic, Marcia Simon  Journal of.
The Art of Flow Cytometry
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Supplemental Digital Content 3 – Figure 2
Anaesthesia with propofol decreases FMLP-induced neutrophil respiratory burst but not phagocytosis compared with isoflurane  J. Heine, K. Jaeger, A. Osthaus,
Epidermal Stem Cells do not Communicate Through Gap Junctions
S.varasteh 10/11/2012.
Flow Cell Injector Tip Fluorescence signals Focused laser beam Sheath
Presentation transcript:

COMPENSATION By: Ronald Mathieu

Compensation Why do we need compensation? –1) Because of long emission spectrum of dyes like FITC and PE.

Compensation –2) Because of the use of bandpass and dichroic filters in the instrument in order to separate fluorescence emission from the excitation light source.

Compensation THE END RESULT IS SPECTRUM OVERLAP WHERE FITC BLEEDS INTO THE PE CHANNEL AND PE BLEEDS BACK INTO FITC. %FITC into PE %PE into FITC

Compensation To correct for spectrum overlap during multicolor flow experiments color compensation must be performed. The goal of color compensation is to correctly quantify each dye with which a particular cell is labeled. This is done by subtracting a portion of one detector's signal from another, leaving only the desired signal.

Compensation This example will show you how to compensate a FITC and PE experiment using a Facscalibur Open the Detectors/Amps and threshold windows by selecting them from the Cytometer drop down menu.

Compensation Loading your negative control Put the machine on run mode and put your negative control on the SIP While the negative control is running under setup mode press acquire and make the following changes Select a location to save your file Select a name for your file

Compensation Make sure the population of interest is clear visible by making adjustment to the FSC/ SSC. Adjust the forward and side scatter by sliding the bar to bring the population of interest toward the center of the plot Population of interest debris

Compensation Separates your population from debris by using the threshold menu Adjust the threshold value by sliding the bar on the threshold window enough to remove most of the debris but not all of them. It is a good idea to have some debris on scale to make sure you are not thresholding out your population. Lots of debris Very little debris

Compensation Select your population of interest by creating a gate around that population draw a gate, which will allow you to remove unwanted debris and aggregates, around the population of interest by selecting a circle or a polygon from the tool template and applies it to all subsequent plot. REGION R1

Compensation Adjusts the voltage on the FITC and PE channel to put the cells in the center of the first log. Adjust the FL1 and FL2 voltage by sliding the bar up or down to bring the population in the middle of the first log. PE only positive PE + FITC positive FITC only positive NEGATIVE

Compensation You are now done with the negative control and ready to move on to the first single stain control Open the compensation window by selecting it from the Cytometer drop down menu. This bar allows you to remove spill over of PE into FITC This bar allows you to remove spill over of FITC into PE

Compensation Compensating the FITC Tube Still under the setup Mode, load the Single FITC control in the machine then press acquire. Your sample will look like the data on the left. Adjust the slide on the FL2- %FL1 to remove the % of FITC spill over in the PE channel. Try not to over compensate, pay attention to the mean of the negative and the FITC positive, they should be about the same. uncompensated compensated We went from 0.0% to 26.0% Y mean = 65 Y mean = 5 Y mean = 6 PE only positive PE + FITC positive FITC only positive NEGATIVE

Compensation You are now done with the FITC tube and ready to compensate your PE control Still under the setup Mode, load the PE single control in the machine then press acquire. Your sample will look like the data on the left. Adjust the slide on the FL1- %FL2 to remove the % of PE spill over in the FITC channel. Try not to over compensate, pay attention to the mean of the negative and the PE positive, they should be about the same. uncompensated compensated We went from 0.0% to 0.6% X mean = 9 X mean = 5 X mean = 6 PE only positive PE + FITC positive FITC only positive NEGATIVE

Compensation THE FITC AND PE COMPENSATION IS DONE. YOU ARE NOW READY TO RECORD DATA AND SAVE YOUR INSTRUMENT SETTING. TO SAVE YOUR INSTRUMENT SETTING: GO TO CYTOMETER MENU THEN SELECT INSTRUMENT SETTING. LOCATE YOUR DIRECTORY AND PRESS SAVE THEN PRESS DONE.